Previous issue date: 2018-06-11 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conversores chaveados são sistemas amplamente utilizadas em aplicações industriais. Tais sistemas operam via controle em malha fechada e, dessa forma, os aspectos de estabilidade e desempenho em malha fechada devem ser assegurados pelo projetista. Recentemente, o emprego de sistemas com múltiplos conversores vem se tornando comum em uma ampla gama de aplicações. A interação entre os sistemas de controle os múltiplos conversores pode levar o sistema a operar com reduzidas margens de estabilidade ou com um baixo desempenho dinâmico. Portanto, a estabilidade de um sistema com conversores operando em cascata é uma grande preocupação para aplicações reais. A instabilidade em sistemas em cascata pode ocorrer devido à carga de potência constante (CPL), que é um comportamento dos conversores quando se encontram regulados. As CPLs exibem comportamento de resistência negativa incremental, causando um alto risco de instabilidade em conversores interligados. Dessa forma, a mitigação desse problema é uma questão importante no projeto da fonte de alimentação comutada de múltiplos estágios, de modo a garantir a estabilidade de todo o sistema. No entanto, algumas dificuldades estão presentes além da CPL, por exemplo, não linearidades fortes, devido à presença do elemento indutivo, além das incertezas em relação aos valores nominais dos componentes discretos que compõem o sistema. Neste trabalho é realizado um estudo experimental do desempenho das metodologias de controle robusto paramétrico aplicadas ao problema de mitigar o efeito adverso de cargas do tipo CPL, em um sistema com dois conversores buck operando em cascata (sistema buck-buck). Vários testes foram desenvolvidos utilizando tanto uma planta experimental quanto via simulação computacional em Matlab/ Simulink, quando o sistema multiconversor buck-buck é submetido a uma variação de potência. Os resultados mostram o melhor desempenho das metodologias propostas. / Multi-converter electronic systems are becoming widely used in many industrial applications; therefore, the stability of the cascaded system is a big concern to real-world power supplies applications. Instability in cascaded systems may occur due to the constant power load (CPL), which is a behavior of the tightly regulated converters. CPLs exhibit incremental negative resistance behavior causing a high risk of instability in interconnected converters; therefore, the mitigation of this problem is an important issue in the multiple-stage switched mode power supply design. Thus, it is important to guarantee stability of the whole system. However, some difficulties remains besides the CPL, e.g., non-linearities due to the inductive element and uncertainties due to imprecision of mathematical models and/or variation of nominal values of the discrete elements that compose the DC/DC buck converter. Aiming to evaluate the performance of the proposed robust methodologies in this work to mitigate the instability problem caused by a CPL, several tests were developed by using an experimental plant and Matlab/Simulink, when the multi-converter buck-buck system is subjected a variation of power reference. The results show the improved performance of the proposed methodologies.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10257 |
Date | 11 June 2018 |
Creators | MARCILLO, Kevin Eduardo Lucas |
Contributors | BARRA JÚNIOR, Walter |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | 1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |