No Brasil os vírus Zika e Chikungunya vem causando enormes epidemias com grande morbidade e significante mortalidade, tornou-se importante desenvolver métodos diagnósticos eficazes para discrimar suas infecções. No presente trabalho, desenvolvemos ensaios imunoenzimáticos utilizando células de cultura, aedes albopictus pseudo C6/36, infectadas e utilizadas como antígeno viral (EIA-ICC), para diagnósticos de infecções provocadas pelos vírus Zika (ZIKV) e Chikungunya (CHIKV). As placas contendo células infectadas tiveram suas antigenicidades verificadas nos ensaios utilizando anticorpos policlonais oriundo de camundongos hiperimunizados com ZIKV, CHIKV e outros flavivirus e alphavirus. O EIAICC ZIKV detectou anticorpos murinos de forma homotípica, porém reações cruzadas foram encontradas com Dengue 1 (DENV 1), Saint Louis Vírus (SLEV), Rocio Vírus (ROCV) e West Nilo Vírus (WNV). O EIA-ICC CHIKV também detectou anticorpos murinos de forma homotípica e reações cruzadas foram observadas com os Mayaro Vírus (MAYV) e Mucambo Vírus (MUCV). Resultados comparativos de 39 amostras foram realizados no EIA-ICC ZIKV, que demonstrou sensibilidade de 87,5% (IgM) e 100% (IgG) e especificidade de 95,65% (IgM) e 83,33% (IgG). O EIA-ICC CHIKV, teste comparativos entre 59 amostras, demostrou sensibilidade de 64,7% (IgM) e 92,3% (IgG) e especificidade de 40% (IgM) e 96,96% (IgG). Os EIA-ICCs também foram usados para diagnósticos das arboviroses ZIKV e CHIKV em 174 soros de pacientes com doença febril aguda, no EIA-ICC ZIKV foi encontrado 8,13% de IgM, 20,34% IgG e 6,97% de IgG e IgM na mesmo soro, no EIA-ICC CHIKV encontramos IgG em 8,13% dos soros e IgG em 16,86%, soros com anticorpos IgG e IgM nos mesmos foram vistos em 1,74%. Também encontramos em 11 soros anticorpos tanto para ZIKV quanto para CHIKV. Portanto o EIA-ICC ZIKV mostrou para detecção de IgM e IgG, adequadamente sensível e específico para ser validado em estudos com maiores números de amostras e ser aplicados no diagnóstico. O EIA-ICC CHIKV mostrou para detecção de IgG, adequadamente sensível e específico para ser validado em estudos com maiores números de amostras e ser aplicados no diagnóstico. Porém não é indicado para a detecção de IgM / In Brazil, Zika and Chikungunya viruses have been causing huge epidemics with great morbidity and significant mortality. It\'s important to develop effective diagnostic methods to discriminate against their infections. In the present study, we developed immunoenzymatic assays using cultured cells from aedes albopictus C6 / 36 infected and used as viral antigen (EIA-ICC), for diagnosis of infections caused by the Zika (ZIKV) and Chikungunya (CHIKV) viruses. Plates containing infected cells had their antigenicities verified in the assays using polyclonal antibodies from mice hyperimmunized with ZIKV, CHIKV and other flaviviruses and alphaviruses. The EIA-ICC ZIKV detected murine antibodies in a homotypic manner, but cross-reactions were found with Dengue 1 virus (DENV 1), Saint Louis virus (SLEV), Rocio virus (ROCV) and West Nile virus (WNV). The EIA-ICC CHIKV also detected murine antibodies in a homotypic manner and cross-reactions were observed with the Mayaro virus (MAYV) and Mucambo virus (MUCV). Comparative results of 39 samples were performed in the EIA-ICC ZIKV, which showed sensitivity of 87.5% (IgM) and 100% (IgG) and specificity of 95.65% (IgM) and 83.33% (IgG). The EIA-ICC CHIKV, a comparative test among 59 samples, showed a sensitivity of 64.7% (IgM) and 92.3% (IgG) and a specificity of 40% (IgM) and 96.96% (IgG). The EIA-ICCs were also used for diagnosis of ZIKV and CHIKV arboviruses in 174 sera from patients with acute febrile illness. In the EIA-ICC, ZIKV found 8.13% IgM, 20.34% IgG and 6.97% IgG and IgM in the same serum, in the EIA-ICC CHIKV we found IgG in 8.13% of the sera and IgG in 16.86%, sera with IgG and IgM antibodies in them were seen in 1.74%. We also found 11 samples positive for both ZIKV and CHIKV. Therefore, the EIA-ICC ZIKV showed for detection of IgM and IgG, adequately sensitive and specific to be validated in studies with larger numbers of samples and to be applied in the diagnosis. The EIA-ICC CHIKV showed for IgG detection, adequately sensitive and specific to be validated in studies with larger numbers of samples and to be applied in the diagnosis. However, it is not indicated for the detection of IgM
Identifer | oai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-30052019-153433 |
Date | 04 December 2018 |
Creators | Silva, Angélica |
Contributors | Figueiredo, Luiz Tadeu Moraes |
Publisher | Biblioteca Digitais de Teses e Dissertações da USP |
Source Sets | Universidade de São Paulo |
Language | Portuguese |
Detected Language | English |
Type | Dissertação de Mestrado |
Format | application/pdf |
Rights | Liberar o conteúdo para acesso público. |
Page generated in 0.002 seconds