Return to search

Validação clínica dos diagnósticos de enfermagem mobilidade física prejudicada, integridade tissular prejudicada e integridade da pele em pacientes submetidos a cateterismo cardíaco

Introdução: Mobilidade Física Prejudicada é um diagnóstico de enfermagem (DE) prioritário para pacientes submetidos a cateterismo cardíaco. No entanto, para os diagnósticos Integridade Tissular Prejudicada e Integridade da Pele Prejudicada, freqüentemente estabelecidos neste cenário, ainda não há um consenso sobre o mais adequado. Estudos de validação de diagnósticos para pacientes submetidos a procedimentos como cateterismo cardíaco diagnóstico ou terapêutico, permanecem inexplorados. Objetivos: Validar clinicamente as características definidoras dos DE Mobilidade Física Prejudicada, Integridade Tissular Prejudicada e Integridade da Pele Prejudicada em pacientes submetidos a cateterismo cardíaco; e validar seis características adicionais aos diagnósticos em estudo. Métodos: Estudo transversal conduzido em Laboratório de Hemodinâmica no interior do Rio Grande do Sul no período de novembro de 2009 a novembro de 2010. Para a validação clínica (modelo proposto por Fehring) utilizou-se um instrumento com as características definidoras dos diagnósticos em estudo, aplicado por duas enfermeiras peritas. Incluíramse pacientes ≥ 18 anos, ambos os sexos, que realizaram cateterismo cardíaco diagnóstico ou terapêutico eletivo, procedimento por via femoral. Foram consideradas características definidoras validadas aquelas com R> 0,50 (taxa de fidedignidade). O teste Kappa também foi utilizado para avaliar a concordância entre as peritas. Os DE em estudo são baseados na Taxonomia da NANDA-I. Resultados: Incluíram-se 250 pacientes, com idade média 63±12 anos. Foram validadas como características definidoras para Mobilidade Física Prejudicada (1º DE): Amplitude limitada de movimento (R=1), Capacidade limitada para desempenhar as habilidades motoras grossas (R=1) e Dificuldade para virar-se (R=0,80); (2º DE) Integridade Tissular Prejudicada foi Tecido lesado (R=1) e (3º DE) Integridade da Pele Prejudicada foram Invasão de estruturas do corpo (R=1) e Rompimento da superfície da pele (R=1). As demais características dos três diagnósticos foram consideradas não representativas para o cenário em que se desenvolveu o estudo. Foram incluídas características definidoras adicionais para o 1º DE: Desconforto, para o 2º DE: Dor aguda, Hematoma, Sangramento, Rubor e Calor. Pelo Teste Kappa todas foram consideradas com concordância excelente. Conclusão: Para pacientes submetidos a cateterismo cardíaco diagnóstico ou terapêutico eletivo validou-se três características para o 1º DE; uma para o 2º DE e duas para o 3º DE. Pelo teste Kappa seis características adicionadas aos diagnósticos em estudo, obtiveram concordância excelente entre as peritas. / Introduction: Impaired Physical Mobility is a prior nursing diagnosis (ND) in patients who underwent Cardiac Catheterization. However, for ND Impaired Tissue Integrity and Impaired Skin Integrity, which are frequently established in this scenario, an adequate consensus lacks. Studies for diagnoses validation in patients who underwent proceedings such as diagnostic or therapeutic cardiac catheterization remains unexplored. Objectives: To clinically validate the defining characteristics of the following nursing diagnosis: Impaired Physical Mobility, Impaired Tissue Integrity, and Impaired Skin Integrity in patients who underwent Diagnostic or Therapeutic Cardiac Catheterization; to clinically validate the six additional characteristics in the diagnoses under study. Methods: Cross-sectional study carried out in a Hemodynamics Laboratory in the countryside of Rio Grande do Sul, Brazil, from November 2009 to November 2010. For clinical validation (Fehring Model) an instrument was used with the defining characteristics of the diagnoses being studied. The instrument was applied by two expert nurses. The patients had ≥ 18 years old, of both sexes, who underwent elective Diagnostic or Therapeutic CARDIAC Catheterization via femoral vein. Validated defining characteristics were considered when presenting R > 0.50 (reliability index). The Kappa test was also used to validate the agreement between the observers. DE in the study is based on the NANDA-I Taxonomy. Results: For this study, 250 patients were included, mean age 63±12 years-old. As valid defining characteristics were R ≥ 0.80 for Impaired Physical Mobility (1st ND): limited range of motion (R=1), limited ability to perform gross motor skills (R=1), difficulty turning (R=0,80); Impaired Tissue Integrity (2nd ND) was Injured Tissue (R=1); and Impaired Skin Integrity (3rd ND) were Invasion of Body Structures (R=1) and Disruption of the Skin Surface (R=1). Other characteristics of these three diagnoses were considered not representative for the scenario where this study was applied. Defining characteristics were included in the 1st ND (discomfort) and in the 2nd ND (Acute Pain, Bruising, Bleeding, Redness and Warmth). According to Kappa Test, six characteristics of them were considered with excellent agreement. Conclusion: For patients who underwent elective Diagnostic or Therapeutic Cardiac Catheterization, three were validated in the 1st ND; one in the 2nd ND; and three in the 3rd ND. According to Kappa Test, six additional characteristics obtained excellent agreement between the expert nurses. / Introducción: La Movilidad Física Perjudicada es un Diagnóstico de Enfermería (DE) prioritario para pacientes sometidos a cateterismo cardíaco. Sin embargo, para los diagnósticos de Integridad Tisular Perjudicada e Integridad de la Piel Perjudicada aun no existe un consenso que apunte al más adecuado. Estudios de validación de diagnósticos para pacientes sometidos a procedimientos como cateterismo cardíaco diagnóstico o terapéutico aun son poco explorados. Objetivo: Validar clínicamente las características que definen los diagnósticos de enfermería: Movilidad Física Perjudicada, Integridad Tisular Perjudicada e Integridad de Piel Perjudicada en pacientes sometidos a cateterismo cardíaco y validar seis características adicionales a los diagnósticos en estudio. Métodos: Estudio transversal realizado en laboratorio de Hemodinamia en el interior de Rio Grande do Sul en el período de noviembre de 2009 a noviembre de 2010. Para la validación clínica (modelo propuesto por Fehring) se utilizó un instrumento con las características que definen los diagnósticos en estudio, siendo aplicado por dos enfermeras perito. Se incluyeron pacientes mayores de 18 años, de ambos sexos que realizaron cateterismo cardíaco diagnóstico o terapéutico (procedimiento por vía femoral). Fueron consideradas características definidoras validadas aquellas con R>0.50 (valor fidedigno). Fue utilizado el test Kappa para evaluar la concordancia entre los peritos. DE en el estudio se basa en la Taxonomía NANDA-I. Resultados: se incluyeron 250 pacientes, media de edad de 63±12 años. Fueron validadas como características definidoras aquellas con R≥0.80 para Movilidad Física Perjudicada (1ºDE): amplitud limitada de movimiento (R=1), capacidad limitada para desempeñar habilidades motoras complejas (R=1) y dificultad para darse vuelta (R=0.8); Integridad Tisular Perjudicada (2ºDE): tejido lesionado (R=1); Integridad de la Piel Perjudicada (3ºDE): invasión de estructuras del cuerpo (R=1), rotura de la superficie de la piel (R=1). Las demás características de los tres diagnósticos fueron consideradas como no representativas para el escenario donde se desarrolló el estudio. Fueron incluidas características definidoras adicionales para el 1ºDE: incomodidad; para el 2ºDE: dolor agudo, hematomas, sangrado, rubor y calor. Todas ellas mostraron una concordancia excelente al utilizar el test Kappa. Conclusión: Para pacientes sometidos a cateterismo cardíaco diagnóstico o terapéutico, han sido validadas 3 características de 1ºDE, una de 2ºDE, y dos de 3ºDE. Con el test Kappa, seis características adicionales obtuvieron concordancia entre las enfermeras perito.

Identiferoai:union.ndltd.org:IBICT/oai:lume.ufrgs.br:10183/28970
Date January 2011
CreatorsCostanzi, Angelita Paganin
ContributorsSilva, Eneida Rejane Rabelo da
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageSpanish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFRGS, instname:Universidade Federal do Rio Grande do Sul, instacron:UFRGS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds