Return to search

Teste graduado da caminhada (Shuttle Walk Test) na avaliação funcional de pacientes com insuficiência cardíaca crônica / Incremental shuttle walk test in the assessment of functional capacity in chronic heart failure

Made available in DSpace on 2015-07-22T20:50:51Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-01-01 / Objetivos: Avaliar a segurança, reprodutibilidade, a acurácia em estimar o consumo de oxigênio pico e o valor prognóstico do teste graduado da caminhada (“shuttle walk test”), em comparação com o teste da caminhada de seis minutos em pacientes com insuficiência cardíaca crônica sintomática. Métodos: Avaliamos prospectivamente 63 pacientes com insuficiência cardíaca. Todos os pacientes realizaram um teste cardiopulmonar, dois testes graduados da caminhada, dois testes da caminhada de seis minutos e foram acompanhados por um período médio de 14,01 ± 7,8 meses. Resultados: A idade média dos pacientes foi 51,28 ± 10,26 anos, a fração de ejeção 24,05 ± 5,69% e o consumo de oxigênio pico 16,79 ± 5,76ml/kg/min. As distâncias percorridas, no 1º e no 2º teste graduado da caminhada foram 414,44 ± 122,87 e 422,85 ± 119,18m, respectivamente, atestando sua ótima reprodutibilidade (ρ&#61472; = 0,979). O teste mostrou-se seguro. A distância percorrida no teste graduado da caminhada foi menor em relação ao teste da caminhada de seis minutos (p < 0,001) e o índice de percepção do esforço foi maior (p = ,029). Houve forte correlação entre as distâncias percorridas em ambos os testes (r = 0,88) e entre o teste graduado da caminhada e o consumo de oxigênio pico (r = 0,79). A acurácia em estimar um consumo de oxigênio pico menor ou igual a 14ml/kg/min foi semelhante nos dois testes. As distâncias percorridas em ambos os testes não foram preditoras de eventos e somente o consumo de oxigênio pico foi preditor de sobrevida livre de eventos. Conclusões: O teste graduado da caminhada é reprodutível, seguro e apresenta boa correlação com o teste da caminhada de seis minutos e com o consumo de oxigênio pico; mostrou-se sensível e específico em estimar um consumo de oxigênio pico inferior a 14ml/kg/min. Entretanto não foi capaz de fornecer informações sobre o prognóstico dos pacientes desta amostra. / Objectives: To access the safety, reproducibility, and accuracy at estimating peak oxygen consumption and prognostic value in shuttle walk test compared to six-minute walk test in patients with symptomatic chronic heart failure. Methods: Sixty-three patients with heart failure were prospectively assessed. All patients underwent cardiopulmonary exercise test, two shuttle walk tests, and two six-minute walk tests. Patients were followed-up for a mean period of 14.01 ± 7.8 months. Results: Mean age of patients was 51.28 ± 10.26 years old, ejection fraction was 24.05 ± 5.69%, and peak oxygen consumption was 16.79 ± 5.76ml/kg/min. Distances walked in the first and second shuttle tests were 414.44 ± 122.87 and 422.85 ± 119.18m, respectively, which proved their great reproducibility (ρ&#61472; = 0.979). The test was also safe. Distance walked in the shuttle walk test was shorter compared to that walked in six-minute walk test (p < 0.001), the perception of effort rate was greater (p = 0.029). There was a strong correlation between the distances walked in both tests (r = 0.88), and between shuttle walk test distance and peak oxygen consumption (r = 0.79). Accuracy to estimate peak oxygen consumption smaller or equal to 14ml/kg/min was similar in both tests. Distances walked in both tests were not predictors of events and peak oxygen consumption was the only predictor of event free survival. Conclusions: Shuttle walk test is reproducible, safe, presenting a satisfactory correlation with six-minute walk test, and with peak oxygen consumption; it has been proved sensitive and specific in estimating peak oxygen consumption lower than 14ml/kg/min. However, it could not provide information on the prognosis of the patients from this sample. / TEDE / BV UNIFESP: Teses e dissertações

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unifesp.br:11600/10113
Date01 January 2006
CreatorsPulz, Cristiane [UNIFESP]
ContributorsUniversidade Federal de São Paulo (UNIFESP), Almeida, Dirceu Rodrigues de [UNIFESP]
PublisherUniversidade Federal de São Paulo (UNIFESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format76 p.
Sourcereponame:Repositório Institucional da UNIFESP, instname:Universidade Federal de São Paulo, instacron:UNIFESP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0164 seconds