Return to search

Avaliação do uso do plasma rico em plaquetas no reparo da rotura do manguito rotador / Evaluation of platelet-rich plasma use in the repair of rotator cuff tear

O plasma rico em plaquetas (PRP) tem sido utilizado na ortopedia como método para melhorar a cicatrização tecidual. Existem poucos estudos com alto nível de evidência sobre o seu efeito no reparo do manguito rotador e os resultados são conflitantes, não havendo consenso sobre sua eficácia. O objetivo primário deste estudo foi avaliar o efeito do uso do PRP em pacientes submetidos ao reparo do manguito rotador por via artroscópica através da escala da University of California at Los Angeles (UCLA). A avaliação clínica através da escala de Constant-Murley, de dor através da escala visual analógica (EVA), a presença de rerroturas na análise da ressonância magnética (RM) e a ocorrência de complicações foram considerados desfechos secundários. Estudo prospectivo, randomizado, duplo-cego. Dois grupos com 27 pacientes (Grupo PRP e Grupo Controle) foram submetidos ao reparo artroscópico em fileira simples de âncoras, sendo que, no Grupo PRP, foi aplicado o concentrado de plaquetas ao final do procedimento. O PRP foi obtido por aférese, aplicado na consistência líquida, com adição de trombina autóloga. Foram incluídas apenas roturas de espessura completa do supraespinal com retração inferior a 30 mm. Os procedimentos foram realizados pelo mesmo cirurgião, entre setembro de 2008 e abril de 2012. Os desfechos foram avaliados através das escalas da UCLA, de Constant-Murley, EVA e pela RM, pré-operatoriamente e aos 3, 6 e 12 meses. A EVA foi aplicada adicionalmente no primeiro e sétimo dia. O nível de significância empregado foi de 5%. Os pacientes apresentaram melhora clínica significativa com o procedimento nos dois grupos (p < 0,001). Evoluíram de 13,63 ± 3,639 para 30,04 ± 4,528 no Grupo Controle e de 13,93 ± 4,649 para 32,30 ± 3,506 no Grupo PRP aos 12 meses (p = 0,046) de acordo com a escala da UCLA, com um poder de 84% e tamanho do efeito de 0,56. De acordo com a escala de Constant-Murley, os pacientes evoluíram de 47,37 ± 11,088 para 76,89 ± 13,198 no Grupo Controle e de 46,96 ± 11,937 para 83,26 ± 11,141 no Grupo PRP aos 12 meses (p=0,061). A avaliação aos 3 e 6 meses não demonstrou diferença significativa. A avaliação pela EVA não demonstrou diferença estatística em nenhum dos tempos de seguimento, evoluindo de 7,00 ± 1,939 no Grupo Controle e de 6,67 ± 1,617 no Grupo PRP no pré-operatório para 1,70 ± 2,127 e 1,04 ± 1,808, respectivamente, aos 12 meses (p = 0,220). Na análise pela RM, o Grupo Controle apresentou uma rerrotura completa e quatro parciais, enquanto o Grupo PRP apresentou duas rerroturas parciais (p = 0,42). Ocorreu um caso de rigidez articular em cada grupo (p = 1). O PRP obtido por aférese, aplicado na consistência líquida e com adição de trombina propiciou melhores resultados pela escala da UCLA aos 12 meses de pós-operatório / Platelet-rich plasma (PRP) has been used in orthopedics as a method to enhance tissue healing. There are few studies with a high level of evidence about its effect on rotator cuff repair, and the results are conflicting, with no consensus about its effectiveness. Clinical assessment as measured by the UCLA (University of California at Los Angeles) shoulder rating scale was established as the primary outcome. The secondary outcomes included clinical assessment on the Constant-Murley scale, pain as measured by a visual analog scale (VAS), the retear rate assessed by magnetic resonance imaging (MRI) and the complication rate. A prospective, randomized, doubleblind trial was conducted. Two groups of 27 patients (PRP Group and Control Group) were subjected to arthroscopic single-row repair. Liquid PRP prepared by apheresis was applied to the PRP Group at the end of the surgical procedure, with autologous thrombin. Complete supraspinatus tears with retraction less than 30 mm were included. The procedures were performed by the same surgeon between September 2008 and April 2012. Outcomes were assessed using UCLA and Constant-Murley scales, VAS and magnetic resonance imaging preoperatively and at 3, 6 and 12 months. The VAS was also applied on days one and seven. The significance level was 5%. The two groups of patients exhibited significant clinical improvement (p < 0.001). The score on the UCLA scale increased from 13.63 ± 3.639 to 30.04 ± 4.528 and from 13.93 ± 4.649 to 32.30 ± 3.506 in the Control and PRP groups, respectively, between the preoperative assessment and after 12 months (p=0.046), with a 84% power and a 0.56 effect size. The score on Constant-Murley scale increased from 47.37 ± 11.088 to 76.89 ± 13.198 in the Control Group and from 46.96 ± 11.937 to 83.26 ± 11.141 in the PRP Group (p = 0.061). Assessment at 3 and 6 months did not identify significant differences. The VAS did not statistically differ at any investigated timepoint and varied from 7.00 ± 1.939 and 6.67 ± 1.617 before surgery to 1.70 ± 2.127 and 1.04 ± 1.808 at the 12-month assessment in the Control and PRP groups, respectively (p = 0.220). The Control Group exhibited one case of complete and four of partial retears, and the Group PRP exhibited two cases of partial retears (p = 0.42). PRP prepared by apheresis, applied in the liquid state with thrombin, promoted better results on the UCLA scale 12 months after surgery

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-27022014-122547
Date16 January 2014
CreatorsEduardo Angeli Malavolta
ContributorsArnaldo Amado Ferreira Neto, Benno Ejnisman, Alberto Naoki Miyazaki
PublisherUniversidade de São Paulo, Ortopedia e Traumatologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0139 seconds