Back to search

University of Guelph

The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model

Abstract

dc:description.abstract

Locking compression plates (LCP) have gained increasing popularity in veterinary and human medicine for their versatility, combining the functions of both locking and conventional plating systems. LCP are frequently used in minimally invasive plate osteosynthesis (MIPO). MIPO aims to preserve fracture biology and is the standard-of-care for fractures in which rigid anatomic reconstruction is not possible. MIPO increases the biomechanical demands on implants through reduced load-sharing between implant and bone. Empty screw holes act as a stress riser and can predispose LCP to premature failure. Locking head inserts (LHI) have been designed to fill empty screw holes in an attempt to improve plate longevity. The present study examined the effect of LHI in an open fracture gap model. LHI were applied to a 3.5 mm broad LCP in three different configurations, (1) no LHI, (2) three central LHI over the fracture gap, and (3) complete filling of empty holes with LHI. LHI were applied with 4 Nm of torque. LCP were attached to synthetic bone models and cyclically loaded with three-degrees of freedom. Surface strain was collected during testing using uniaxial strain gauges. Construct stiffness was calculated from load and deformation data collected by the biomechanical testing apparatus. No significant difference in implant peak-to-peak strain, or construct stiffness and peak-to-peak deformation were detected with the addition of LHI. Results from this study indicate that the addition of LHI did not significantly impact the biomechanical properties of a 3.5 mm broad LCP. In clinical high-load fracture fixation scenarios, alternative methods of reducing implant fatigue should be considered.

Degree

thesis:*
Name thesis:degree_name
Doctor of Veterinary Science
Department thesis:degree_department
Department of Clinical Studies
Grantor dc:publisher
University of Guelph

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hawker, William
Advisor dc:contributor.advisor
  • Moens, Noel

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Attribution-ShareAlike 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10214/28352

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hawker, William. The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model. University of Guelph, https://hdl.handle.net/10214/28352