Back to search

University of Minnesota

Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results

Abstract

dc:description.abstract

This prospective, multi-center clinical study was completed to evaluate the initial clinical performance of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing thread depth toward the apex. A total of 32 implants were placed in 31 patients. Exclusion criteria included uncontrolled metabolic diseases, uncontrolled periodontal disease, history of head & neck radiation, and current use of bisphosphonates. Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and mean ISQ value of 68.6 compared to delayed implant mean torque value of 39.4 Ncm and a mean ISQ value of 68.6. Neither of these differences in measures were statistically significant. Overall, one implant failed during the early healing phase resulting in an early implant survival rate of 96.9% (31/32 implants). Within the limitations of the study, including a relatively small sample size, only reporting early surgical and healing phases, and lack of control, the T3 Pro implant system by ZimVie demonstrated favorable early clinical results and promising surgical performance.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cory, Maxwell

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Cory, Maxwell. (2026). Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282277.

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation