Back to search

West Virginia University

Accuracy, Prosthetic Outcomes, and Patient-related Outcomes with Immediate Loading of 4-Guided Implants Supporting an Unsplinted Maxillary Implant-Retained Overdenture

Abstract

dc:description.abstract

Aim: Assess the accuracy of implant placement using a mucosa-supported surgical guide relative to the planned implant position and examine patient-related outcomes associated with immediately-loaded Mx IOD using a single-attachment abutment system. The secondary aim of the study is to examine the prosthetic complications associated with this treatment. Materials and methods: Fifteen individuals with edentulous maxillae were included. Each participant received 4 Straumann BLX implants through a stereolithic mucosa-supported surgical guide distributed in the Mx arch to maximize AP spread. Implant lengths ranged from 10 to 14 mm. A post-op CBCT was taken after the surgery to compare the accuracy of the implant placement with the planned position using the Treatment Evaluation Module in CoDiagnostix. Primary outcome variables were 3D offset at apex and platform along with global angular deviation and patient-related outcomes. Results: Fifteen participants had 60 implants placed. Fifty-nine of those implants were suitable for assessment. The mean global deviation of the implants was 3.28±1.929º, the 3D offset of the implants was 0.86±0.484 mm at the platform and 1.036±0.59 mm at the apex. Statistically significant higher 3D offset was observed for the implant platform and apex between posterior and anterior implants at 0.762 vs. 0.984 and 0.862 vs. 1.203 mm respectively. Conclusion: The accuracy of mucosa-supported surgical guides for Mx IODs is within the acceptable range of error when compared to planned position. Posterior implants show greater deviation than anterior implants. Patient-related outcomes improve immediately after the prosthesis is loaded and continue to improve over the follow-up period.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis (Campus Access)
Discipline thesis:degree_discipline
Restorative Dentistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chertok, Nathaniel
Contributors dc:contributor
  • Matthew Harper
  • Gian-Pietro Schincaglia
  • Arif Salman Abdul Shakore
  • Fotinos Panagakos

Subjects

dc:subject × 8

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Chertok, Nathaniel. Accuracy, Prosthetic Outcomes, and Patient-related Outcomes with Immediate Loading of 4-Guided Implants Supporting an Unsplinted Maxillary Implant-Retained Overdenture. Thesis (Campus Access) thesis, https://doi.org/10.33915/etd.11319