Abstract

dc:description.abstract

An active research topic is the detection of various oscillations that may lead to instability and potential disruption in the operation of a power network. Forced Oscillations (FOs) play a unique role in power system stability among various oscillations. They are perturbances that change the system’s state and are caused for many reasons, including but not limited to persistent load changes and oscillatory load or generation, fault, triplane, and other mechanical anomalies. These factors can hugely affect the power grid by either increasing or decreasing the amplitude, causing corrupt modes leading to blackouts, affecting the equipment involved, delivering poor power quality, generator tripping, and impeded efforts to monitor modal oscillations. If detected early, FOs can be isolated and mitigated; however, their detection must happen within the first several seconds of the origin of the oscillations. Thus, the development of fast and effective detection algorithms is a key to preventing a power outage. The state of the modern power grid is monitored using a network of Phasor Measurement Units (PMUs). EachPMUkeeps track of complex-valued voltage, current, and frequency as time progresses. These time-series measurements are sensitive enough to detect and localize the cause of oscillations in a power network. In this Project Report, we implement an asymptotic generalized likelihood ratio test statistic (GLRT) to detect FOs in a power network and use an autoregressive process to model the power spectral densities of both the ambient noise and FOs. The estimated power spectral densities, using the magnitude of both current and voltage for a subset of 12 PMU sensors in the network, are substituted in the GLRT statistic to analyze if the known FO is detected. We also focus on the effects of AR model order selection on detection performance. In previous research performed by Pierre, it was hypothesized that the maximum of the detection statistic provided accurate localization of a FO present in the system. Our results demonstrate that the AR model-based GLRT statistic shows excellent reliability in detecting FOs; however, the maximum of the detection statistic is not always observed in the data of the PMU sensor closest to the origin of the FO. Thus, the statement that the location of a FO can be identified based on the location of the maximum of the detection statistic must be investigated further, leaving us with a bulk of future work.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Problem/Project Report
Discipline thesis:degree_discipline
Lane Department of Computer Science and Electrical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suarez, Maria Waleska
Contributors dc:contributor
  • Natalia Schmid
  • Muhammad Choudhry
  • Sarika Khushalani-Solanki

Subjects

dc:subject × 7

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Suarez, Maria Waleska. An Efficient AR Model-Based Method for the Detection of Forced Oscillations in Power Networks: Implementation and Analysis. Problem/Project Report thesis, https://doi.org/10.33915/etd.11214