Study of Barrier Face Coverings and Respirator Exhalation Filtration Efficiency and Exhaled Air Velocity During Wear

Abstract

dc:description.abstract

This study aimed to assess the effectiveness of different types of respiratory protection, including National Institute for Occupational Safety and Health (NIOSH) Approved respirators and surgical masks in healthcare settings, as well as barrier face coverings (BFCs) used by the public as source control. The assessment was based on three components: total outward leakage (TOL), particle size distribution, and exhalation airflow velocity. To achieve this, the study utilized headform testing systems to measure TOL and airflow velocity. Specifically, a hard surface headform was used for NIOSH Approved respirators and surgical masks, while two soft surface headforms of different sizes were used for the BFCs used by the public. The findings revealed that N95 filtering facepiece respirators (N95 FFRs) were more effective in reducing outward leakage compared to surgical masks (SMs), but proper fit was crucial for both. Elastomeric half-mask respirators (EHMRs) and N95 FFRs with an exhalation valve (N95 FFRVs) were not suitable for source control in healthcare settings, especially during high flowrate activities. The effectiveness of ASTM medical masks in reducing outward leakage was comparable to surgical masks while that of ASTM Level 3 masks was compromised by poor fit. The single-layer cloth BFCs were ineffective, while the multiple-layer cloth masks equipped with HEPA or PM 2.5 filters had better performance. The size of the headform is a crucial factor that significantly impacts the TOL. On average, when BFCs are worn on a medium-sized headform, they exhibit a higher TOL compared to those worn on a large-sized headform. The study also highlighted the limitations of NIOSH approved respirators against certain particle sizes, which are more likely to spread infectious viruses via airborne transmission. Both medical and nonmedical BFCs were effective in reducing exhalation airflow velocity but had limitations in source control against certain particle sizes. The study emphasized the importance of proper fit testing, adequate training, and adherence to protocols for optimal respiratory protection. Additionally, it is imperative to practice ventilation and social distancing even though a source control measure is implemented.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Industrial and Managements Systems Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Weihua
Contributors dc:contributor
  • Warren R. Myers
  • Ashish Nimbarte
  • Jeremy Gouzd
  • Zhichao Liu
  • Kenneth J. Ryan
  • Ziqing Zhuang

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Identifier
<p><a href="https://orcid.org/0000-0002-2849-2786">https://orcid.org/0000-0002-2849-2786</a></p>
https://researchrepository.wvu.edu/etd/12108

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Yang, Weihua. Study of Barrier Face Coverings and Respirator Exhalation Filtration Efficiency and Exhaled Air Velocity During Wear. Dissertation thesis, https://doi.org/10.33915/etd.12108