Back to search

West Virginia University

Accuracy of implants placed using stackable static surgical guides for full-arch implant-supported fixed dental prostheses: A retrospective study.

Abstract

dc:description.abstract

Abstract Accuracy of implants placed using stackable static surgical guides for full-arch implant-supported fixed dental prostheses: A retrospective study. Thomas Palmer Stanley, D.D.S., M.S. Aim: The primary objective is to investigate the accuracy of implants placed with stackable static surgical guides of Synergy Guided Workflow® (Absolute Dental Services, Inc., Durham, NC, USA) for the purpose of full-arch rehabilitation with implant-supported screw-retained fixed dental prostheses. The secondary objectives are to evaluate the implant and prosthesis survival rates, and prosthetic maintenance needs. Methods: This retrospective study enrolled patients who underwent Synergy Guided Workflow® for 1 or more arches from January 2020 – March 2025. Post-operative CBCTs were be uploaded to coDiagnostiX® (Dental Wings Inc., Montreal, Canada) Treatment Evaluation module and superimposed with the pre-operative CBCT containing the surgical and prosthetic plan. The planned dental implant was superimposed to the final position using tangential, cross-sectional, and axial views. Global angular deviation, 3D offset (base), and 3D offset (tip) was collected for each implant. Results: 24 were identified utilizing Synergy Guided Workflow® stackable static surgical guides. 11 patients (17 arches with 73 implants) met the inclusion criteria for the study. The mean total angular global deviation was 4.23±2.80°, 3D offset at the base 1.40±0.86 mm and 3D offset at the tip was 1.60±0.89 mm. Intraclass correlation coefficient (ICC) of 0.49, 0.52, and 0.49 was calculated for comparison between individual surgical guides in global deviation, 3D offset (base) and (tip), respectively, indicating moderate reliability. Conclusion: Stackable static surgical guides streamline restorative procedures and have similar accuracy of static guides in total global angular deviation, 3D offset at the base and tip as static guides. Accepted standard 2 mm safety margin should still be considered when using the Synergy Guided Workflow® stackable static surgical guides.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis (Campus Access)
Discipline thesis:degree_discipline
Restorative Dentistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stanley, Thomas Palmer
Contributors dc:contributor
  • Arif Salman Abdul Shakore
  • Shelby Alexander
  • Bryan Weaver

Subjects

dc:subject × 7

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Stanley, Thomas Palmer. Accuracy of implants placed using stackable static surgical guides for full-arch implant-supported fixed dental prostheses: A retrospective study.. Thesis (Campus Access) thesis, https://doi.org/10.33915/etd.12794