Back to search

West Virginia University

Analysis of shotshell breech face impressions using a computer-based algorithm

Abstract

dc:description.abstract

Forensic firearm analysis involves the comparison of test fires from a suspect firearm to an unknown sample, typically collected from a crime scene. Test fires and the unknown sample are examined for agreement in class characteristics and sufficient agreement in individual characteristics using a comparison microscope. The forensic analysis of firearms has been challenged both in court and by governmental organizations for its subjective nature and the inability to accurately report error rates. To combat these challenges, the National Institute of Standards and Technology (NIST) has proposed using computer-based algorithms, such as Congruent Matching Cells (CMC). These CMC algorithm calculates the degree of similarity between samples using topography measurements. Instead of using the Association of Firearm and Tool Mark (AFTE) Theory of Identification, the number of congruent matching cells determines if the unknown sample and test fires were discharged by the same firearm. Two shotguns, a Mossberg® 500® and a Remington® 870TM each discharged 405 shotshells with varying pellet weight, pellet size, and charge weight. Shotshells were then scanned with a confocal microscope prior to being imported into the CMC algorithm for cropping and comparisons. Comparisons were only performed within the same firearm and were analyzed to determine applicability of the CMC algorithm in regard to shotshell comparisons as well as to determine if there was any influence by pellet weight, pellet size, and charge weight on the breech face impressions. The results of this study demonstrated that the CMC algorithm can be applied to shotshell comparisons. In order to improve the utility of the algorithm the congruency thresholds need to be optimized for such firearms. The area of the firing pin impressions on shotshells are very large in comparison to area of the primer surface. This resulted in high false negative rates for both firearms (FNR Mossberg®500® = 48.4% and FNR Remington®870TM = 38.9%) when using the CMC threshold of six (the threshold determined for pistols). The results show that charge weight, pellet size, and pellet weight all affect the CMC count and CMCpercentages due to the variation in breech face impressions as a result of their role in the cycle of fire.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Forensic and Investigative Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Carly Renee
Contributors dc:contributor
  • Keith Morris
  • Tatiana Trejos
  • Eric Law

Subjects

dc:subject × 6

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Smith, Carly Renee. Analysis of shotshell breech face impressions using a computer-based algorithm. Thesis thesis, https://doi.org/10.33915/etd.13019