Back to search

West Virginia University

Mode I fracture and durability of the CFRP -concrete interface bond

Abstract

dc:description.abstract

The continual degradation of civil infrastructures worldwide has prompted the need for effective solutions, posing major challenges to those involved with reinforced concrete structures. Externally bonded fiber reinforced polymer (FRP) composites have proven to be an efficient means of rehabilitation and enhancement to both existing and new structures alike. An important issue regarding this technology that needs further exploration, however, is the strength and integrity of the interface bond---the inadequacy of which can result in premature failure of the reinforced member.;Until now, there were no available methods to rigorously evaluate the interface bond strength and integrity for concrete structures externally reinforced with FRP materials. Existing large-scale tests of structural components used for stiffness and strength evaluations, on the one hand, are ill suited for detecting delamination effects. On the other, small-scale tests only provide average interface strength properties that neither describe failure mechanisms nor provide fracture toughness data.;In an effort to resolve this dilemma, a new test methodology, referred to as the Single Contoured-Cantilever Beam (SCCB) specimen, conceived and fashioned after the established double cantilever beam (DCB), is implemented. Using this newly developed experimental fracture approach, insights have been gained into the elusive fracture toughness of the CFRP-concrete interface. This methodology is then extended to evaluate the fracture toughness of the same interface as subjected to one of three commonly encountered field exposure-conditions: (1) wet-dry cycling under sodium-sulfate (Na2SO4), (2) wet-dry cycling under sodium-hydroxide (NaOH), and (3) freeze-thaw cycling under calcium chloride (CaCl2) attack. Considerable degradation of the interface bond integrity is found to have resulted in each case, when compared with companion specimens of the same age. This new test method can therefore serve both to qualify existing products as well as in developing new formulations of adhesives and FRP systems.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Civil and Environmental Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Boyajian, David Moses

Subjects

dc:subject × 2

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Boyajian, David Moses. Mode I fracture and durability of the CFRP -concrete interface bond. Dissertation thesis, https://doi.org/10.33915/etd.2459