Back to search

West Virginia University

Central supply company noise survey.

Abstract

dc:description.abstract

Central Supply Company was interested in having a noise survey completed at two locations, a concrete batch plant and a block manufacturing plant. Noise levels were measured to evaluate the current hearing conservation program and to determine potential overexposure, compliance, and appropriateness of protection. Employee dosimetry results showed that sound levels at the concrete batch plant were not high enough to require employee enrollment in a hearing conservation program. At the block manufacturing plant, employee dosimetry results showed there was a need for a hearing conservation program, including a need for hearing protection to be worn at all times during production.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Problem/Project Report
Discipline thesis:degree_discipline
Industrial and Managements Systems Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Drelick, Janice

Subjects

dc:subject × 2

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Drelick, Janice. Central supply company noise survey.. Problem/Project Report thesis, https://doi.org/10.33915/etd.3983