West Virginia University
Generation and Evaluation of Reference Samples as part of an Evacuated Canister Interlaboratory Study
Abstract
dc:description.abstractEvacuated canisters offer an opportunity to expand on the way volatile organic compounds (VOCs) are measured in indoor air quality investigations, industrial hygiene assessments, and emergency response scenarios. There is a growing need for alternative sampling methods for VOCs as traditional sorbent tube sampling methods may not adequately capture the multitude of chemicals present in mixed exposure environments due to sorbent-analyte specificity.;This study is part of a larger work designed to address this need across a suite of 17 VOCs. This study assesses generation and evaluation methods for the production of reference evacuated canister samples as part of an ASTM-style interlaboratory study. The interlaboratory study was designed to assess evacuated canister method performance for the development of a National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods protocol.;The reference canister samples were generated in two concentration ranges (part-per-million and part-per-billion) and at three nominal concentration levels within the two ranges. For the PPB range, samples were generated using either a flow-based dilution or combination pressure dilution and canister-to-canister transfer technique. For the PPM range, samples were generated by either the combination pressure dilution and canister-to-canister transfer technique, or a manifold dilution method. The reference canister samples were analyzed via gas chromatography-mass spectrometry (GC-MS). The performance of three preparation methods and three analytical methods were assessed by the NIOSH 95% confidence interval on accuracy criterion.;Results indicate that method accuracy is concentration dependent with respect to certain combinations of analytical method, preparation technique, and analyte. Some sample preparation techniques were found to be better for certain groups of compounds and at certain concentration ranges. All 17 VOCs passed the NIOSH accuracy criterion for the PPM range when prepared using the pressure dilution technique and analyzed via a 1 cc loop injection into a GC-MS. For the PPB range of concentration levels, 15 VOCs passed the NIOSH accuracy criterion when prepared by the pressure dilution method and analyzed via a 250 cc, cryogenically concentrated injection into a GC-MS.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Industrial and Managements Systems Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Burns, Dru
- Contributors dc:contributor
-
- Steven E Guffey
- Xinjian He
- Ryan F LeBouf
Identifiers
dc:identifier.*- Identifier
- https://researchrepository.wvu.edu/etd/5285