Back to search

West Virginia University

Effect of Particle Concentration, Sealing Condition and Breathing Rate on Total Inward Leakage for N95 Filtering Facepiece Respirators

Abstract

dc:description.abstract

Several researchers have considered the relationship between total inward leakage (TIL) and other parameters such as sealing condition, particle concentration, type of particulate material breathing parameters, etc., however, there is dearth of information on the effects of varying particle concentration on the penetration efficiency of filtering facepiece respirators (FFRs), hence, this study aims to study the effect of varying NaCl particle concentration, sealing condition and breathing rate on the TIL as a result of the filtering efficiency of the filters. To achieve this, we followed the sampling procedure used by He et al., 2014. Four different sealing conditions (SCs) namely; fully sealed, fully opened, chin sealed, and cheek & chin sealed was used. NaCl aerosol particle was used at varying concentration levels of 100,000 (100K), 200,000 (200K) and 400,000 (400K). Also, we used mean inspiratory flow rates of 15LPM, 30LPM, 55LPM and 85LPM which we refer to as breathing rate throughout this study. Visual presentation of result was done with Python 3.8 and data analysis was carried out using R version 3.6.0 (2019-04-26). The statistical model statement follows the equation TILSC = βo + β1B + β2C + β3BC + £. where B is the breathing rate at the 4 MIF, 15, 30, 55, and 85; C is concentration and BC is the interaction between Breathing flow rate and the concentration. TILsc is the total inward leakage at the different sealing conditions The result shows that the variables have effect on the TIL for both fully opened and cheek and chin sealed condition with or without interaction between the variables at 0.05 confidence level. For fully sealed and chin sealed condition, the variables have no significant effect on the mean TIL response when interaction between variables was considered and when interaction between variables was not considered. In conclusion, there is statistically significance difference for mean TIL response with the change in sealing conditions, varying concentrations of NaCl particle and breathing rates. This study showed that in studying the effect of varying NaCl particle concentration, sealing conditions and breathing rate on the TIL, it is only under both fully opened and cheek and chin sealed conditions that the mean TIL response is significantly affected by the factors in consideration. Hence, workers should not expose their nose region at any time to prevent exposure.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Industrial and Managements Systems Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lawal, Taoreed T.
Contributors dc:contributor
  • Warren Myers
  • Micheal McCawley
  • Ziqing Zhuang

Subjects

dc:subject × 7

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lawal, Taoreed T.. Effect of Particle Concentration, Sealing Condition and Breathing Rate on Total Inward Leakage for N95 Filtering Facepiece Respirators. Thesis thesis, https://doi.org/10.33915/etd.7890