Back to search

West Virginia University

Dynamic Modelling and Control of Grid-Level Energy Storage Systems

Abstract

dc:description.abstract

The focus of this work is on two energy storage technologies, namely pumped storage hydroelectricity (PHS) and secondary batteries. Under secondary battery technologies, two potential technologies for grid-scale storage, namely high-temperature sodium-sulfur (NaS) battery and vanadium redox flow battery (VRFB), are investigated. PHS is a largescale (>100 MW) technology that stores and generates energy by transporting water between two reservoirs at different elevations. The goal is to develop a detailed dynamic model of PHS and then design the controllers to follow the desired load trajectory accurately with high efficiency. The NaS battery and VRFB are advanced secondary batteries which can be charged and discharged rapidly. Since temperature excursion of high temperature NaS batteries especially under fast cycling conditions is a safety hazard and the temperature excursion can take place at some location within the cell where measurement is not feasible, the focus is on a model-based approach for transient analysis and development of novel thermal management techniques. A detailed thermo-electrochemical dynamic model of a single NaS has been developed. As a detailed cell model is computationally intractable for simulating large number of cells in the battery, various strategies such as coordinate transformation, orthogonal collocation, and model reformulation have been developed to obtain a reduced order model that solves significantly faster than the full, high-dimensional model but provides an accurate estimate of the key variables such as transient voltage/current/temperature profile in the cell. Sodium sulfur batteries need to be maintained within a temperature range of 300-4000C. Therefore, the focus was on developing thermal management strategies that can not only maintain the cell temperature near the optimum, but can effectively utilize the heat, improving the overall efficiency of the battery system. VRFBs can provide large amount of storage as the electrolytes are stored in separate tanks. However, the self-discharge reactions (due to crossover) along with the undesired side reactions and the dissolved water in the membrane, can significantly reduce the capacity. A dynamic model-based approach is developed for detection, identification, and estimation of capacity fade and SOC as a function of time. A model-based prognostic capability has been developed for estimating the remaining useful cell life.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Chemical and Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vudata, Sai Pushpitha
Contributors dc:contributor
  • Debangsu Bhattacharyya
  • Richard Turton
  • Fernando V. Lima
  • Xingbo Liu
  • Parviz Famouri
  • Nianqiang Wu

Subjects

dc:subject × 11

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Vudata, Sai Pushpitha. Dynamic Modelling and Control of Grid-Level Energy Storage Systems. Dissertation thesis, https://doi.org/10.33915/etd.8141