Spelling suggestions: "subject:"[een] CEMENT"" "subject:"[enn] CEMENT""
1321 |
Análise da influência de um reforço de solo-cimento compactado na extremidade superior de estacas escavadas, sob carregamentos horizontaisFioratti, Netúlio Alarcón [UNESP] 28 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:21Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-08-28Bitstream added on 2014-06-13T19:53:00Z : No. of bitstreams: 1
fioratti_na_me_ilha.pdf: 4780447 bytes, checksum: 4d7a8999b3e1a6db619819e0e04948e9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nesta pesquisa foi executado um reforço (cilíndrico com 1 m de diâmetro e 1 m de profundidade) de solo-cimento (cujo solo foi corrigido granulometricamente com resíduo de concreto triturado) compactado ao redor do fuste de estacas de concreto escavadas com trado mecânico (com 32 cm de diâmetro e profundidade de 8,71 m) em solo arenoso do Campo Experimental da UNESP em Ilha Solteira-SP com o intuito de avaliar sua contribuição para neutralização das cargas horizontais. A mistura entre solo e resíduo na proporção de 1:1 em massa, estabilizada com 8% de cimento (em massa seca de mistura) foi testada e mostrou-se bastante adequada para a utilização neste propósito, pois, para ser estabilizada com cimento, a mistura necessitou de menor quantidade de cimento que o solo natural (2 pontos percentuais) e o solo-cimento daí resultante apresentou resistência aos 28 dias de 6,32 MPa. Após ensaio de carregamento horizontal nas estacas reforçadas e comparação com os resultados de ensaios nas mesmas estacas sem reforço obtidos de Del Pino Jr. (2003), observou-se que para uma mesma carga aplicada os deslocamentos sofreram grande redução, enquanto para atingir um mesmo deslocamento foi necessário elevado acréscimo de carga. O coeficiente de reação horizontal do solo (nh) do conjunto estaca-solo em questão teve uma elevação da ordem de 200% do valor original. Também foram calculados os esforços (cortantes e fletores) e deslocamentos ao longo do fuste das estacas, que apresentaram sensível redução, para mesma carga aplicada, após reforço. Os resultados apontam o resíduo de concreto triturado como excelente material para correção granulométrica de solos utilizados para confecção de solocimento compactado e o solo-cimento compactado como um cilindro no entorno de estacas escavadas em solo arenoso sendo um reforço bastante eficiente para absorver esforços horizontais / This research produced one improvement (cylindrical – 1 meter diameter and 1 meter deep) made of soil-cement (wich soil was granulometrically corrected with concrete ground remains) compacted around the concrete bored piles head (32 cm diameter and 8,71 meters deep) on a sandy soil from the Trial Field of UNESP, Ilha Solteira – SP, in order to measure it’s contribution to neutralize the horizontal loading. The mix between soil and remains in proportions 1:1 in mass, stabilized with 8% of cement (dry mass of mix) was tested and proved to be very adequate for the research purpose, because the mix needed less quantity of cement than natural soil (2 percentage points) to be stabilized and the soil-cement resulting presented resistance in 28 days of 6,32 MPa. After the test of horizontal loading on the reinforced piles, compared with the results of tests with the same piles without improvement obtained from Del Pino Jr (2003), it was observed that for the same applied load the displacements had a great reduction, while for reaching the same displacement need high load increasing. The coefficient of the soil’s horizontal reaction (nh) from the set pile-soil concerned has it’s value increased to 200% from the original value. Also were measured the efforts and displacements along the stem piles, that had significant reduction after improvement. Results indicate ground concrete remains as an excellent material for granulometric correction of soil for confection of compacted soil-cement and the compacted soil-cement as a cylinder around the excavated piles head on sandy soil proved to be very efficient to absorb horizontal efforts
|
1322 |
Microdureza de cimentos de ionômeros de vidro indicados para a técnica do ART, variando-se a proteção superficial e o tempo de armazenamentoShintome, Luciana Keiko [UNESP] 25 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-06-25Bitstream added on 2014-06-13T19:41:13Z : No. of bitstreams: 1
shintome_lk_dr_sjc.pdf: 280293 bytes, checksum: 55405500ef310209c685206fa028963c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a microdureza de cimentos de ionômero de vidro (CIV): Vidrion R (V) .- SS White; Fuji IX (F) . GC Corp; Magic Glass ART (MG) - Vigodent; Maxxion R (MR) - FGM e ChemFlex (CF) - Dentsply, na presença ou ausência de proteção superficial, em diferentes períodos de armazenamento. Para cada CIV foram confeccionados 36 corpos-de-prova (3 mm altura X 3 mm diâmetro), divididos em 3 grupos em função da proteção superficial (sem proteção, verniz do Fuji IX ou esmalte para unha). Os espécimes foram armazenados em água destilada por 24 h, 7 e 30 dias e os testes de microdureza foram realizados nestes tempos. Os dados obtidos foram submetidos ao teste de ANOVA para medidas repetidas e teste de Tukey ('alfa'=5%), e revelaram que os valores médios de microdureza, no geral, em ordem decrescente dos CIV foram: F > CF = MR > MG > V; que a proteção superficial foi significante para o MR em 24 h sem proteção (64,2'mais ou menos'3,6a), proteção com verniz (59,6'mais ou menos'3,4b) e com esmalte (62,7'mais ou menos'2,8ab); para o F, em 7 dias, sem proteção (97,8'mais ou menos'3,7ab), proteção com verniz (95,9'mais ou menos'3,2b) e com esmalte (100,8'mais ou menos'3,4a) e em 30 dias para o F sem proteção (98,8'mais ou menos'2,6b), proteção com verniz (103,3'mais ou menos'4,4a) e com esmalte (101'mais ou menos'4,1ab) e V sem proteção (46'mais ou menos'1,3b), proteção com verniz (49,6'mais ou menos'1,7ab) com esmalte (51,1'mais ou menos'2,6a) e o aumento do tempo de armazenamento proporcionou um aumento da microdureza. Concluiu-se que os diferentes CIV, tipo de proteção e tempo de armazenamento, podem alterar os valores de microdureza... / The aim of this study was to evaluate the microhardness of glass ionomer cement (GIC): Vidrion R (V) - SS White; Fuji IX (F) - GC Corp.; Magic Glass ART (MG) - Vigodent; Maxxion R (MR) - FGM and ChemFlex (CF) - Dentsply, with or without surface protection in different storage time. Thirty six specimens for each GIC (3 mm diameter X 3 mm height) were made and these specimens were divided into three groups, according to the surface protection (without protection, varnish protection of the Fuji IX or protection with nail varnish). The samples were stored in distilled water for 24 h, 7 and 30 days and the microhardness test was carried out using a microhardner in those times. The data were submitted to repeated measures analysis of variance test and Tukey test ('alfa' =0.05) and showed that mean microhardness values, in general, of the GIC followed the decrescent order: F > CF = MR > MG > V; the surface protection was significant for MR in 24 h without protection (64.2'mais ou menos'3.6a), protection with varnish (59.6'mais ou menos'3.4b) and nail varnish (62.7'mais ou menos'2.8ab); for F in 7 days without protection (97.8'mais ou menos'3.7ab), protection with varnish (95.9'mais ou menos'3.2b) and nail varnish (100.8'mais ou menos'3.4a); for F in 30 days without protection (98.8'mais ou menos'2.6b), protection with varnish (103.3'mais ou menos'4.4a) and nail varnish (101'mais ou menos'4.1ab) and for V in 30 days without protection (46'mais ou menos'1.3b), protection with varnish (49.6'mais ou menos'1.7ab) and nail varnish (51.1'mais ou menos'2.6a) and surface microhardness generally increased with time. It was concluded that different trade mark, surface protection and storage times can influence microhardness of GIC.
|
1323 |
Influência da smear layer e sua espessura na adesão e citotoxicidade de um cimento de ionômero de vidro modificado por resinaMendonça, Adriano Augusto Melo de [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-03-23Bitstream added on 2014-06-13T19:20:24Z : No. of bitstreams: 1
mendonca_aam_dr_arafo.pdf: 4133222 bytes, checksum: f9bc8aa3130de1ab931f42b45220c045 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi avaliar a citotoxicidade do cimento de ionômero de vidro modificado por resina (CIVMR) sobre células odontoblastóides MDPC- 23 cultivadas sob discos de dentina com ou sem smear layer de diferentes espessuras. Além disto, o estudo também investigou se a permanência ou a remoção da smear layer poderia interferir na resistência de união do material com o substrato dentinário. Para isto, 40 discos de dentina com espessura de 0,4mm foram obtidos de terceiros molares humanos hígidos. Após limpeza das superfícies dos discos com ácido etilenodiamino tetra-acético (EDTA, pH 7.2), medidas de condutância hidráulica foram realizadas como forma de padronização da permeabilidade entre os discos. Lixas d’água de granulação 180 e 600 foram utilizadas para a formação da smear layer espessa e delgada, respectivamente. Desta forma, a distribuição dos discos de dentina resultou nos seguintes grupos controle e experimentais: G1M - grupo controle; G2M – Smear layer Espessa + CIVMR; G3M – Smear layer Delgada + CIVMR; G4M – Smear layer Espessa Removida + CIV; G5M – Smear layer Delgada Removida + CIVMR. Após divisão e posicionamento dos discos em câmaras pulpares artificiais, 50.000 células odontoblástóides MDPC-23 foram cultivadas sobre sua superfície pulpar. Decorridos 48 horas do cultivo, o CIVMR VitrebondTM foi aplicado sobre a superfície oclusal dos mesmos discos de dentina com ou sem smear layer. Após 24 horas, o metabolismo das células foi determinado através da avaliação da atividade da desidrogenase succínica (MTT assay). A morfologia celular foi analisada em microscopia eletrônica de varredura (MEV). Para avaliação da resistência adesiva, outros 40 terceiros molares com dentina oclusal exposta tiveram o VitrebondTM aplicado dentro das mesmas condições já descritas (com ou sem smear layer). Os grupos experimentais... / The objective of present study was to evaluate the cytotoxicity of a resin-modified glass-ionomer cement (RMGIC) on odontoblast-like cells MDPC-23 plated under dentin discs when smear layer with different thickness was removed or not. In addition, it was also investigated whether presence or not of the smear layer could change in the bond strength of material on dentin substrate. Forty dentin discs with 0.4 mm thickness were obtained from caries and restoration free human third molars. The hydraulic conductance of all dentin discs was evaluated. One hundred eighty and 600-grit silicon carbide paper were employed to created thick and thin smear layer, respectively. Thereby, the distribution of dentin disc revealed the following experimental e control groups: G1M – control group; G2M – thick smear layer + RMGIC; G3M – thin smear layer + RMGIC; G4M – Thick smear layer Removed + RMGIC; G5M – Thin smear layer Removed + RMGIC. After adapting the dentin discs in artificial pulp chambers, the odontoblast like cells MDPC-23 (50.000 cells) were plated on the pulpal surface of these discs and incubated for 48 hours. Then the RMGIC VitrebondTM was applied on the oclusal surface of the dentin discs with or without smear layer. After 24h incubation, the cell metabolism was determined through evaluation of succínic desidrogenase enzime (MTT assay). The cell morphology was investigated by scanning electronic microscopy (SEM). To evaluate bond strength, VitrebondTM was applied on the oclusal dentin surface of 40 human third sound molars treated as previously reported (with or not smear layer of different thickness). The experimental and control groups were determined: G1R – Thick smear layer + EDTA + RMGIC; G2R - Thin smear layer + EDTA + RMGIC; G3R - Thick smear layer + RMGIC; G4R - Thin smear layer + RMGIC. Each specimen characterized by the VitrebondTM applied on the exposed and treated... (Complete abstract click electronic access below)
|
1324 |
Avaliação da resistência de união à dentina de restaurações estéticas indiretas: efeito da contaminação e limpeza dentináriaFreitas, Cláudia Regina Buainain de [UNESP] 27 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-03-27Bitstream added on 2014-06-13T19:20:26Z : No. of bitstreams: 1
freitas_crb_dr_arafo.pdf: 227207 bytes, checksum: 5b30a90b1e585db9913701192fdf3161 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de cimentos provisórios e de métodos de limpeza dentinária na resistência de união de restaurações indiretas em resina à dentina. Foram selecionados 21 terceiros molares recém extraídos e isentos de cárie. A parte da coroa dental correspondente ao esmalte foi removida expondo-se toda superfície dentinária. Os dentes foram divididos aleatoriamente em sete grupos experimentais de acordo com o cimento provisório e o método de limpeza dentinária utilizado: (G1-controle) não recebeu restauração provisória nem limpeza dentinária; (G2) cimentação provisória com Life e limpeza com pasta de pedra-pomes; (G3) cimentação provisória com Life (Kerr) e limpeza com jato abrasivo; (G4) nenhum procedimento de limpeza foi executado após cimentação com Life; (G5) cimentação provisória com Temp Bond e limpeza com pasta de pedra-pomes; (G6) cimentação provisória com Temp Bond (Kerr) e limpeza com jato abrasivo e (G7) nenhum procedimento de limpeza foi executado após cimentação com Temp Bond. Após uma semana de armazenamento em água, restaurações de Solidex (Shofu) foram cimentadas com adesivo Single Bond (3M ESPE) e cimento Rely X ARC (3M ESPE). Todos os produtos foram manipulados de acordo com as instruções do fabricante. Os dentes foram seccionados obtendo-se espécimes de 1,0 mm2 para realização de teste de microtração. Os valores obtidos foram submetidos à análise de variância e teste de Tukey. Os resultados indicaram que o grupo contaminado com hidróxido de cálcio sem realização da limpeza dentinária apresentou os menores valores de resistência e foi estatisticamente diferente do grupo onde não houve contaminação. Qualquer dos cimentos e métodos de limpeza utilizados obteve as maiores médias de resistência, porém sem diferenças significativas entre elas. / The purpose of this study was to evaluate the effect of provisional cements and dentin cleaning methods on the adhesion of resin bonded indirect restorations. Flat dentin surfaces were produced cutting extracted human molars. The teeth were divided randomly in seven experimental groups according with the provisional cement and the used dentin cleaning method: (G1- control) no provisional restoration and no dentin cleaning; (G2) pumice-water slurry cleaning after cementation with Life (Kerr); (G3) aluminum oxide sandblasting after cementation with Life; (G4) no cleaning procedure after Life cementation; (G5) pumice-water slurry cleaning after cementation with Temp Bond (Kerr); (G6) aluminum oxide sandblasting after cementation with Temp Bond and (G7) no cleaning procedure after Temp Bond cementation. After one week of storing in water, Solidex indirect restorations (Shofu) were cemented with Single Bond adhesive system (3M ESPE) and Rely X ARC cement (3M ESPE). All products were handled according with manufacturer’s instructions. The teeth were sectioned resulting in adhesion area of 1,0 mm2 specimens for microtencile tests. The resulted values were submitted to variance analysis and Tukey’s test. These values indicated the group which was contaminated with calcium hydroxide cement and had no dentin cleaning presented the lowest bond strength and was statistically different from the group with no contamination. Any of the used cements and cleaning methods got the highest means of bond strength, but with no relevant differences among them. With these results can be concluded that, after the treatment with provisional cements, the absence of dentin cleaning implies in lower bond strength values.
|
1325 |
Efeito da espessura oclusal do cimento e da sua união à cerâmica na resistência à fratura de coroas CAD/CAM: método de elementos finitos e testes monotônicosMay, Liliana Gressler [UNESP] 04 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-10-04Bitstream added on 2014-06-13T19:24:16Z : No. of bitstreams: 1
may_lg_dr_sjc.pdf: 946538 bytes, checksum: 6dc08819ff6da0a49abe52da44ee3e73 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste estudo avaliou-se a influência da espessura oclusal do cimento e de sua união à cerâmica na resistência à fratura de coroas CAD/CAM. O software COMSOL Multiphysics® foi utilizado para análise de elementos finitos (AEF) em modelos axi-simétricos bidimensionais de coroas de cerâmica vítrea estilizadas, com espessura oclusal de 1,5 mm, cimentadas à troqueis de material análogo à dentina quanto ao módulo elástico e potencial de união à resina composta (NEMA G-10 International Paper, USA). Variou-se as espessuras oclusais de cimento resinoso de 50 a 500 μm. Uma carga de 500 N foi aplicada com um pistão de extremidade circular plana (2 mm de diâmetro) sobre as coroas. A contração de polimerização do cimento foi simulada através de contração térmica. O contato entre cimento e cerâmica foi configurado para “união” e “ausência de união”. O contato cimento-troquel foi sempre do tipo “união”. As tensões dadas pela AEF foram utilizadas para o cálculo de cargas para fratura, levando-se em conta os efeitos deletérios da usinagem e do condicionamento ácido relatados na literatura. As coroas (Mark II, Vita Zhanfabrik, Germany) foram usinadas (CEREC InLab, Sirona, Germany), condicionadas e cimentadas (Multilink Automix, Ivoclar, Lietchstein) à troqueis de NEMA G-10 (n=6). Para a produção de corpos-de-prova na condição “ausência de união”, aplicou-se uma fina película de poli(dimetilsiloxano) 30,000 cSt na superfície interna das coroas. As coroas foram submetidas à carregamento de 5N/s, com pistão de NEMA G-10, de extremidade plana e 2 mm de diâmetro. As fraturas radiais foram detectadas por sensor acústico. A magnitude das tensões resultantes da contração de polimerização dependeram da condição de união à cerâmica e da espessura oclusal de cimento. As cargas médias para fratura (N) de coroas com “união” ao cimento foram... / In this study the influence of the occlusal cement thickness and its bonding to ceramic on the stresses and failure-loads of CAD/CAM crowns were evaluated. The software used for finite element analysis (FEA) was COMSOL Multiphysics®. Bi-dimensional axially symmetric models simulated stylized feldspathic crowns (1.5 mm occlusal thickness) with resin cement layers of 50 μm, 100 μm, 300 μm and 500 μm on dentin analog (NEMA G-10, International Paper, USA) under 500 N loading (2 mm diameter piston). Polymerization shrinkage of the cement layer was simulated as thermal contraction. Ceramic-cement interface was either bonded or not; cement-dentin was always bonded. Stress data were used for load-to-fracture predictions, using literature strengths accounting for milling and acid etching. Mark II® (Vita Zahnfabrik) crowns were milled (Cerec InLab®, Sirona), etched and cemented (Multilink Automix®, Ivoclar) to dentin analogs (NEMA G-10) (n=6). Non-bonding was achieved by applying a thin layer of 30,000 cSt poly(dimethylsiloxane) on the internal surface of the crowns. Crowns were loaded (5N/s) beneath a 2mm flat G-10 piston and radial cracks were detected acoustically. Stress magnitude resulting after cement shrinkage and loading depended on the bonding condition and on the cement thickness. Average failure loads (N) of bonded crowns were: 673.5 N for 50μm-cement thickness and 300.6 N for 500 μm. For non-bonded crowns, failure loads were 308,3 N, for 50 μm cement thickness and 233,3 N, for 500 μm. Bonded crowns presented failure loads at least two times higher than non-bonded, for 50 μm cement thickness, both experimentally and by FEA-based predictions. The benefit of bonding was lost when the cement was thicker than 500 μm. The resistance to fracture decreased with the cement thickness. Calculated loads based on FEA stresses and experimental data were comparable for the evaluate... (Complete abstract click electronic access below)
|
1326 |
Avaliação de cloretos pelo método de aspersão de solução de nitrato de prataClério Bezerra de França 13 June 2011 (has links)
A corrosão por cloretos é considerada por muitos pesquisadores a mais severa das manifestações patológicas que atacam as armaduras. O objetivo principal deste trabalho é avaliar a presença de cloretos livres em concreto de
cimento Portland pelo método de aspersão de solução de nitrato de prata. A verificação de ataque por cloreto na estrutura é normalmente feita através de exames laboratoriais, demorados em que apresentam um custo muito alto. Pesquisando a aplicabilidade do método de aspersão de nitrato de prata in loco, em materiais à base de cimento Portland como indicador com capacidade de informar a
presença ou não de contaminação por cloretos, evitando assim de imediato o teste laboratorial. Para que os resultados destes ensaios tivessem credibilidade quanto à presença de cloretos livres nas amostras, foi realizado, paralelamente à aspersão de nitrato de prata, um acompanhamento das amostras através de ensaios eletroquímicos. Observou-se com os resultados experimentais da pesquisa que a
aplicabilidade do método de aspersão de solução de nitrato de prata vem a ser de grande relevância para o meio técnico, por ser um método qualitativo, de fácil aplicação, barato e provendo informações rápidas para que os profissionais da área
de engenharia possam diagnosticar com segurança as estruturas com corrosão contaminadas por cloreto / The corrosion by chlorides is considered by a number of researchers the most dangerous pathological manifestation attacking concrete reinforcements. The assessment of the attacks to the structure by sodium chloride is usually done in the laboratory, takes too long and costs too much. The.main reason for this work is to assess the presence of free chlorides in Portland cement concrete and mortar
through the silver nitrate aspersion method, which is justified by the fact that Our objective is to evaluate the applicability of the silver nitrate aspersion method in loco, in Portland-cement-based materials as indicators capable of showing the presence or not of contamination by chlorides, avoiding the immediate need for lab tests. So as to give credibility to the test for presence of free chlorides in the samples, these were checked by means of electrochemical tests in parallel with the silver nitrate
aspersion. The experimental results of these tests showed that the applicability of the silver nitrate aspersion method seems to be of great relevance in the technical
environment, as it is a qualitative method, easily applicable, inexpensive and capable of providing quick information so that professionals can safely diagnose the levels of chloride corrosion in the structures
|
1327 |
Avaliacao clinica e histologica da resposta periodontal a procedimentos restauradores no caoGomes, Sabrina Carvalho January 1999 (has links)
Os objetivos do presente estudo foram avaliar a resposta periodontal, clínica e histologicamente, à presença de preparos cavitários restaurados com Cimento de Ionômero de Vidro (CIV) e Amálgama (AM) ou não restaurados (SR), em um período de 124 dias. Janelas cirúrgicas, 2x5mm, na tábua óssea vestibular de pré-molares em 3 cães Beagle, permitindo o preparo de cavidades supragengivais com extensão subgengival (Tipo I) ou subgengivais (Tipo II). Estas foram restauradas com CIV e AM' ou mantidas sem restauração (SR). Nos primeiros 15 dias pós-operatório, os cães receberam escovação diária com gel de clorexidina 2%. Com a suspensão do controle químico, iniciou-se o controle mecânico realizado, diariamente, nos quadrantes 2 e 3, por 109 dias. Placa visível (IPV), profundidade de sondagem (PS), sangramento à sondagem (SS) e distância da margem gengival à marca referência (DMM) foram registrados no início e final do período experimental. Após, análise microscópica foi realizada por examinadora, cega quanto à origem dos tratamentos e previamente calibrada, onde avaliou-se infiltrado inflamatório, condição e posição do epitélio adjacente à área tratada e a distância entre a borda apical do preparo cavi o e ligamameennttoo periodontal funcional (DPL). Através da avaliação clínica observou-se medianas de 66% e 100% para o IPV nos sítios sem controle de placa (S/CT). Para o SS, este foi observado em 8 dos 16 sítios S/CT e 1 em 18 dos sítios onde o controle de placa foi realizado (C/CT). As médias da PS variaram de 0.35 a 1.25, estando as maiores associadas a sítios S/CT. As médias da DMM variaram de -0.2mm (AM, Tipo I, C/CT), indicando edema, a 1,5mm (SR, Tipo II, S/CT), valor relacionado a retração. Sítios AM S/CT apresentaram-se com infiltrado inflamatório severo. Os sítios CIV e SR estiveram associados a escores Leve e Ausente na presença de controle de placa e à resposta Moderada nos sítios S/CT. Para a condição epitelial, observou-se total alteração deste nos sítios restaurados com AM. Na avaliação dos sítios C/CT e S/CT, para CIV e SR, um maior percentual de epitélio íntegro esteve associado aos sítios Tipo I (50%). Nos sítios Tipo II, o controle de placa foi diferencial apenas para os sítios SR. A posição apical deste epitélio foi mais comum para o AM. As maiores DPL estavam associadas ao AM (0.5 a 1 mm), seguidas pelo CIV (0.2 a 0.5 mm) e sítios SR (0.5 a —0.5mm). Pode-se concluir que o controle de placa é decisivo para a reação inflamatória do periodonto a procedimentos restauradores e que o AM, entre os materiais restauradores, foi aquele associado à maior resposta inflamatória.
|
1328 |
Reação álcali-agregado : avaliação do comportamento de agregados do sul do Brasil quando se altera o cimento utilizado / Alkali-aggregate reaction: evaluation on the behavior of the aggregates from southern region of Brazil when different types of Portland cements are appliedBonsembiante, Francieli Tiecher January 2006 (has links)
A reação química que ocorre entre os hidróxidos alcalinos presentes nos poros do concreto e alguns minerais constituintes dos agregados tem causado sérios danos às estruturas. Até o presente momento a prevenção é a melhor forma de evitar que a reação se desencadeie, uma vez que as soluções remediativas ainda necessitam de estudos mais aprofundados para serem implementadas. Neste sentido, a utilização de adições pozolânicas no concreto tem se mostrado uma alternativa eficaz, sendo que a forma mais fácil de empregá-las é através do uso de cimentos compostos com adições. Porém, são poucos os estudos encontrados avaliando a capacidade desses cimentos na prevenção da reação. No Brasil, além dessa lacuna de conhecimento, faltam informações sobre a reatividade dos agregados utilizados no concreto. Então, o presente estudo avaliou a reatividade dos agregados mais utilizados para confecção de concreto nos estados do Paraná, Santa Catarina e Rio Grande do Sul frente à utilização de quatro tipos de cimento: CP V-ARI, CP V-ARI RS, CP IV e CP II-Z. Os métodos utilizados para essa avaliação foram a análise petrográfica, o ensaio acelerado das barras de argamassa, a microscopia eletrônica de varredura e a espectometria por dispersão de energia. Os resultados da análise petrográfica mostraram que todos os 40 agregados coletados possuem minerais reativos. As expansões medidas no ensaio acelerado acabaram por confirmar a potencialidade reativa desses minerais, pois todas as amostras moldadas com o CP V-ARI, o CP V-ARI RS e o CP II-Z foram classificadas como reativas ou potencialmente reativas, isto é, somente o CP IV foi eficaz para inibir as expansões deletérias. Por outro lado, as análises microscópicas mostraram que mesmo nos prismas menos expansivos houve a formação do gel sílico-alcalino, porém este ficou incluso nos poros da argamassa. Outra conclusão percebida foi a de que as maiores expansões ocorreram com os agregados de origem ígnea vulcânica, principalmente com os basaltos, que além de serem constituídos por minerais muito finos, apresentam em sua matriz mesóstases silicosas amorfas, também conhecidas como vidro vulcânico. / The chemical reaction that occurs between alkali hydroxides contained in concrete pores and some minerals contained in aggregates has been causing serious hazards to concrete structures. So far, prevention is the best way to avoid the occurrence of this reaction, once the solutions to repair the damage still need deeper researches to be implemented. Therefore, the use of Portland cements containing pozzolanic admixtures to produce has been an effective alternative. But there are few researches on the capability of those prevent reaction to occur. In Brazil, besides the lack of knowledge, there is little information about the reactivity of the aggregates applied in concrete production. So this research aimed to evaluate the reactivity of the most used aggregate to produce concrete in the states of Parana, Santa Catarina, and Rio Grande do Sul by testing four different types of cements as described: CP V-ARI, CP V-ARI RS, CP IV and CP II-Z. The methods applied to carry out this evaluation were the petrography analysis, the accelerated mortar bar test, scanning electron microscopy, and the dispersive energy spectrometry. The results obtained showed that all the forty aggregate samples collected have reactive minerals in their composition. The measured expansions during the accelerated test confirmed the reactive potentiality of these minerals, because all samples obtained from the CP V-ARI, CP V-ARI RS, and CP IV were classified as being reactive or potentially reactive, which means that CP IV was the only one capable of inhibit the hazardous expansion. On the other hand, the microscopic analyses showed, even in the less expansive prisms, that the formation of silica-alkaline gel has occurred, but this gel has remained in the pores of the mortar. Another conclusion of this research was that larger expansions occurred with the aggregates from volcanic igneous origin, especially basalts that, besides contained very fine minerals, presented in its matrix amorphous silica, also known as volcanic glass.
|
1329 |
[en] CRACKING MECHANISMS AND AUTOGENOUS HEALING CAPABILITY OF CEMENTITIOUS COMPOSITES REINFORCED WITH CURAUA FABRIC / [pt] MECANISMOS DE FISSURAÇÃO E AUTOCICATRIZAÇÃO DE COMPÓSITOS CIMENTÍCIOS REFORÇADOS COM TECIDO DE CURAUÁLETICIA OLIVEIRA DE SOUZA 27 March 2018 (has links)
[pt] O presente trabalho tem como objetivo o estudo do comportamento mecânico, os mecanismos de fissuração e a autocicatrização de compósitos cimentícios reforçados com fibras de curauá. Desenvolveram-se três tipos de compósitos distintos, cada um reforçado com uma, três ou cinco camadas de tecido unidirecional de curauá. O comportamento mecânico foi avaliado por meio de ensaios de tração direta e flexão a quatro pontos. Estudaram-se os mecanismos de fissuração por meio de fotografias obtidas ao longo dos ensaios, além de análises por correlação digital de imagens (Digital Image Correlation - DIC). Estágios de carregamento foram identificados e associados com o espaçamento entre as fissuras formadas. Os corpos de prova de flexão foram instrumentados com strain gauges nas faces inferior e superior, a fim de medir as deformações de tração e compressão. Dessa forma, foi possível realizar um estudo sobre o desenvolvimento da linha neutra e correlacionar as deformações com espaçamento entre fissuras. A capacidade de autocicatrização dos compósitos foi avaliada por meio de ensaios mecânicos cíclicos e de carregamento contínuo, e também por acompanhamento da evolução das fissuras. Estas foram monitoradas com o auxílio de microscópio estereoscópico. As amostras foram expostas a diferentes ambientes (seco, ciclos de água borrifada, imersão em água) e a influência deles foi avaliada. Todos os compósitos apresentaram strain/deflection hardening com formação de múltiplas microfissuras. Fissuras na presença de água apresentaram cicatrização total e parcial, demostrando que o material desenvolvido é promissor para a ocorrência de autocicatrização. / [en] The present work aims to study the mechanical behavior, cracking mechanisms and the autogenous healing capability of cementitious composites reinforced with curauá fabric. Composites with one, three and five fabric layers were produced. Their mechanical behavior was evaluated through direct tensile and four point bending tests. The cracking mechanisms were studied using image analysis of both photographs took during the tests and Digital Image Correlation (DIC). Various stages of loading were identified and associate with the crack formation. The effect of flexural cracking on the composite neutral axis position was analyzed using strain-gages and correlated with the crack spacing. The autogenous healing capability of the three layered composite system was analyzed by means of the mechanical behavior, in cyclic bending and constant load tests. The crack evolution was follow with microscope stereoscope. The samples were subject to several conditions (RH of 55 percent, cycles of spayed water, water immersion) and their influence was evaluated. All the composites presented strain/deflection hardening behavior with multiple microcrack formation. Cracks exposed to water were partially or totally healed, demonstrating that three layered composite is a promising material for autogenous healing.
|
1330 |
Estudo do efeito eletrostático na filtração de partículas de cimento em filtros de mangasOliveira, Flávia Matias 30 April 2015 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-09-30T17:56:23Z
No. of bitstreams: 1
DissFMO.pdf: 2016401 bytes, checksum: 6866947ec8d256db2aefd27468b572ce (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-04T17:30:18Z (GMT) No. of bitstreams: 1
DissFMO.pdf: 2016401 bytes, checksum: 6866947ec8d256db2aefd27468b572ce (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-04T17:30:30Z (GMT) No. of bitstreams: 1
DissFMO.pdf: 2016401 bytes, checksum: 6866947ec8d256db2aefd27468b572ce (MD5) / Made available in DSpace on 2016-10-04T17:30:37Z (GMT). No. of bitstreams: 1
DissFMO.pdf: 2016401 bytes, checksum: 6866947ec8d256db2aefd27468b572ce (MD5)
Previous issue date: 2015-04-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Nowadays the control of industrial pollution is essential. Through filtering, you can remove
the suspended solids in gases. It has been need for more efficient methods for gas filtration in
order to reduce waste generation and decrease energy consumption. In this study was
proposed to investigate the behavior of the particulate matter, cement and the influence of
particle size in formation of gas dust cake, with and without eletrostatic charged. The filter in
order to determine aspects were analyzed and compare their characteristics after filtration,
defining which one operationally more suitable for this process. In this investigation the study
aims optimize the filtration operation. In order to obtain a greater retention of particulates. In
this sense, fabric filter were analyzed, glass and polypropylene filter, while gas filtration.
Cement was used as particulate material with grain sizes 8, 14 and 20μm, the corona
chargering was added in the filtration of gas during the formation of dust cake. The tests were conduction in an attempt to understand this effect the electrostatic charge, improve and
increase the service life of the filter media. Was necessary to adapt it to the equipment one
system gas filtration, localized in Department of Chemical Engineering (DEQ) of Federal
University of São Carlos (UFSCar), for receive the corona charged. The experiment was
conducted from voltage of 0 to -2 kV test with a filtration rate of 10 cm/s, and the mass flow
of 9 mg/s. With the tests done, it possible show that, with the application the corona
chargering the dust cake changes. It can be that the particle size directly affects the filtration
efficiency and the load, can increase the efficiency the collect to particulate and decrease pressure drop during filtration of gases. / Atualmente o controle da poluição industrial é essencial. Através da filtração, é possível
remover os sólidos suspensos nos gases. Tem-se então a necessidade de métodos eficientes
para filtração de gases a fim de reduzir a geração de resíduos e diminuir o consumo de
energia. O presente estudo objetivou investigar o comportamento do material particulado,
cimento e a influência do seu tamanho de partícula na formação da torta de filtração de gases,
com e sem carregamento eletrostático. Foram analisados os aspectos do filtro com intuito de
determinar e comparar suas características após as filtrações, definindo qual delas será mais
adequada operacionalmente para este processo. Além destas investigações o estudo busca
otimizar a operação de filtração. Para que se possa obter uma maior retenção de particulados.
Neste sentido, foram analisados filtros de tecidos, de fibra de vidro e polipropileno, durante a
filtração de gases. Utilizou-se o cimento como material particulado, com granulometrias de 8,
14 e 20μm, o carregamento corona foi adicionado na filtração durante a formação da torta de
filtração. Os testes foram realizados na tentativa de compreender esses efeitos causados a
partir de cargas eletrostáticas, objetivando melhorar e aumentar o tempo de vida útil dos
meios filtrantes. Para isso adaptou-se um sistema de filtração de gases, existente no
Departamento de Engenharia Química (DEQ) da Universidade Federal de São Carlos
(UFSCar), para receber um carregador corona. Posteriormente determinou-se o ponto ótimo
de operação a uma vazão mássica de 9 mg/s e velocidade de filtração de 10 cm/s, variando-se
a tensão da unidade entre 0, e -2,0 kV. Através dos ensaios realizados foi possível observar
que, com a aplicação da corrente corona, ocorreu uma alteração na formação da torta de
filtração. Pode-se dizer que o tamanho da partícula afeta diretamente a eficiência da filtração e
que a carga, pode aumentar a eficiência de coleta das partículas e diminuir a perda de carga
durante a filtração de gases.
|
Page generated in 0.0503 seconds