• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 457
  • 336
  • 88
  • 64
  • 50
  • 20
  • 14
  • 13
  • 10
  • 9
  • 8
  • 5
  • 4
  • 4
  • 3
  • Tagged with
  • 1269
  • 687
  • 250
  • 162
  • 97
  • 91
  • 73
  • 72
  • 67
  • 67
  • 64
  • 63
  • 63
  • 61
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Avaliação da rugosidade superficial após o emprego de diferentes métodos de descontaminação da superfívie em discos de titânio = estudo in vitro / Evaluation of surface roughness after use different methods the decontamination on surface of titanium discs

Diefenbach, Ana Lúcia 16 August 2018 (has links)
Orientador: Márcio Zaffalon Casati / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T22:38:20Z (GMT). No. of bitstreams: 1 Diefenbach_AnaLucia_M.pdf: 6428742 bytes, checksum: 0c06242da8f41dfb2cd02646ac4e0208 (MD5) Previous issue date: 2010 / Resumo: Os procedimentos capazes de descontaminar a superfície implantar removendo o biofilme garantem o sucesso e a longevidade dos implantes. As conseqüências na rugosidade superficial gerada por esses procedimentos têm sido avaliadas, porém novas propostas para descontaminação das superfícies implantares vêm sendo utilizadas, principalmente para o tratamento da periimplantite. Assim, objetivo deste trabalho foi avaliar, in vitro, a rugosidade superficial de discos cilíndricos de titânio após uso de cureta plástica; jato de bicarbonato; esfregaço de tetraciclina e ultrassom piezoelétrico. Foram utilizados 50 discos de titânio com dimensões de 5 mm de altura por 5 mm de largura, com superfícies jateadas com óxido de alumínio. Os discos foram divididos aleatoriamente em cinco grupos experimentais. Grupo 1(n=10) controle - sem tratamento; grupo 2(n=10) - recebeu 15 movimentos de raspagem com cureta plástica; grupo 3(n=10) - aplicação de jato de bicarbonato por 30s a cinco milímetros da superfície; grupo 4(n=10) - aplicação de tetraciclina ácida 50mg/ml por esfregaço vigoroso por 30 segundos e grupo 5(n=10) - aplicação de 15 movimentos de raspagem por meio de ultrassom piezoelétrico com irrigação de solução polidora. Após o procedimento foram realizadas três leituras paralelas e três perpendiculares ao sentido da instrumentação utilizando rugosímetro, visando à obtenção dos valores de rugosidade superficial nos parâmetros de Ra e Rz. Os discos foram avaliados em Microscopia Eletrônica de Varredura,para a visualização da topografia superficial após os procedimentos. A análise estatística foi realizada utilizando o teste Kruskall-Wallis com um nível de significância de 5% para comparação dos valores de rugosidade superficial de cada grupo. A análise dos dados mostrou que o menor valor de rugosidade Ra foi obtido no grupo do ultrassom piezoelétrico (0.89±0.06 µm) em relação ao grupo controle (0.85±0.03 µm). O uso de tetraciclina ácida foi o tratamento que provocou maior rugosidade (0.99±0.09 µm) sendo estatisticamente diferente do grupo controle (p_0,05). Em relação ao parâmetro Rz, os resultados mostraram que o esfregaço de tetraciclina e a cureta plástica obtiveram os maiores valores de Rz (8.37±0.76 µm e 8.49±0.74µm; respectivamente) estatísticamente diferentes ao grupo controle (7.33±0.34 µm) com significância de 5%. Além disso, o uso do ultrassom piezoelétrico (7.85±0.69 µm), nos valores de Rz, não promoveu uma alteração significativa na superfície de forma a ser estatisticamente diferente do grupo controle. O estudo conclui que uso do ultrassom piezoelétrico não promoveu aumento significativo da rugosidade superficial dos discos de titânio nos parâmetros de Ra e Rz e que o jato de bicarbonato obteve valores estatísticamente semelhantes aos grupos 1, 2,4 e 5 nos dois parâmetros avaliados. O grupo da cureta plástica e esfregaço de tetraciclina ácida geraram valores estatísticamente superiores em relação ao controle e ultrassom piezoelétrico no parâmetro Rz. Todos os grupos apresentaram visualmente, a partir das fotos em microscopia eletrônica de varredura, alterações em sua superfície / Abstract: Procedures able to decontaminate the implant surface decreasing biofilm become essential to the success and longevity of implant therapy. The consequences of surface roughness generated by these procedures have been evaluated, but new proposals for decontaminating implant surfaces have been used mainly to treat periimplantite. Thus the objective was to evaluate, in vitro, the surface roughness of cylindrical titanium discs treated by plastic curette; bicarbonate jet; smear tetracycline or piezoelectric ultrasound. A total of 50 titanium discs with dimensions of 5 mm high and 5 mm wide, surfaces blasted with aluminum oxide were used. The discs were randomly divided into five groups: group 1 (n = 10)control - no treatment, group 2 (n = 10) received 15 scraping motions with plastic curette, group 3 (n = 10) application of bicarbonate jet for 30 seconds to five millimeters of distance from the surface and group 4 (n = 10) application of vigorous scraping with 50mg/ml tetracycline acid on the surface of the discs for 30 seconds and group 5 (n = 10) application of 15 scraping movements with teflon tip by ultrasonic piezoelectric with polisher irrigation solution. After treatment, three parallel and three perpendicular readings were taken to the direction of the instrumentation using a rugosimeter in order to obtain surface roughness parameters Ra which represents the arithmetic mean of the absolute values of all deviations from the surface in relation to the median in the area of sampling, and Rz which represents the average between the absolute height of the Five highest peaks and the absolute values of the 5 deepest valleys exist in the length of sampling. Furthermore, the discs were evaluated in scanning electron microscopy, an increase of 100X and 1000X, to visualize the surface topography after the procedures. Statistical analysis was performed using the Kruskal-Wallis test with a significance level of 5% compared to the values of surface roughness of each group. The lowest roughness Ra was obtained in the group of piezoelectric ultrasound (0.89 ± 0.06 µm) compared to control (0.85 ± 0.03 µm). The use of tetracycline acid was the treatment which increased the roughness (0.99 ± 0.09 µm) was statistically different from the control group (p _ 0.05). Regarding the parameter Rz, the results showed that the smear of tetracycline and plastic curette had the highest values of Rz (8.37±0.76 µm e 8.49±0.74µm, respectively) statistically different to control group (7.33 ± 0.34 µm) with significance 5%. Moreover, as the values of Ra, the use of piezoelectric ultrasound (7.85 ± 0.69 µm), the values of Rz, did not cause a significant change in the surface so as to be statistically different in the control group. The study concludes that use of piezoelectric ultrasound did not cause significant increase in surface roughness of titanium discs in the parameters of Ra and Rz. The bicarbonate jet obtained values statistically similar to other groups in both parameters .The group of plastic curette and smear tetracycline acid generated values statistically different from the control and ultrasound in piezoelectric parameter Rz. All groups presented visually, from the pictures on scanning electron microscopy, changes on its surface / Mestrado / Periodontia / Mestre em Clínica Odontológica
252

Influencia da radiação nas propriedades de compositos odontologicos / Influence of radiation on properties of composite restorative resin

Viero, Flavio Luiz 25 July 2006 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T22:46:39Z (GMT). No. of bitstreams: 1 Viero_FlavioLuiz_D.pdf: 553886 bytes, checksum: 6455fb7d1e46ecd9328257967d685d33 (MD5) Previous issue date: 2006 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes doses de radiação X produzida a partir do Cobalto -60, em dois tipos de materiais odontológicos: o compósito Filtek TM A 110 3M, utilizado para restauração d e dentes anteriores; e o compósito condensável SureFilTM indicado para restauração cB dentes posteriores. Foram confeccionados 70 corpos de prova, dos quais 25 foram destinados ao teste de dureza Knoop e 50 ao teste de rugosidade de superfície. Depois de confeccionados, os corpos de prova foram acondicionados em caixas de acrílico e submersos em água destilada por um período de 24 horas, tendo com finalidade obter-se a estabilização química dos materiais. Após esse período, foram submetidos ao teste de Microdureza e de rugosidade de superfície. Obtidas essas medidas, os corpos de prova foram submetidos à irradiação, com as seguintes doses: 0,25Gy; 0,50Gy; 0,75Gy; 1Gy. Passadas 24 horas da irradiação, os mesmos 25 corpos de prova foram novamente submetidos ao teste de microdureza e os mesmos 50 éD teste de rugosidade. Logo após a realização do teste de rugosidade, os 50 corpos de prova foram submetidos à abrasão, sendo a seguir submersos em água destilada, permanecendo por 24 horas. Após esse período, um terceiro teste de rugosidade de superfície foi realizado nesses corpos de prova. De posse das medidas obtidas e após estas serem submetidas à análise estatística - Teste Tukey e o teste T pareado, observou-se que os tipos de compósitos irradiados apresentaram uma redução estatisticamente significante, nos valores de dureza Knoop, quando comparados ao material não irradiado; entretanto não foi observada diferença significante entre os grupos irradiados. Quando avaliada a rugosidade, observou-se que não houve diferença entre o grupo controle e o irradiado; entretanto houve diferença estatisticamente significante, dentro de cada grupo, antes e após os corpos de prova terem sido submetidos à abrasão. Conclui-se que, portanto, que a irradiação influenciou a dureza Knoop, mas não interferiu na rugosidade dos dois compósitos avaliados / Abstract: The aim of the present study was to evaluate the effects of different )f radiation doses produced by cobalt-60 teletherapy unit on two types of restorative dental materials: 3M Filtek TM A 110 used for forward teeth restorations and condensable SureFilTM used for back teeth restorations. Seventy five specimens were fabricated, 25 were submitted to Knoop hardness test and 50 to surface roughness. Next, the samples were immersed in distilled water in an acrylic support for chemical stabilization for 24 hours, and evaluated before irradiation test. Afterwards the samples were submitted to microhardness test and to surface roughness. Subsequently, samples were irradiated with single doses of 0,25Gy; O,50Gy; 0,75Gy; 1Gy. Twenty four hours after irradiation, the same samples were evaluated considering both tests - roughness and microhardness. After these procedures, the 50 samples used for the roughness surface evaluation were submitted to abrasion and stored in distilled water for 24 hours. After this period, the roughness surface were again analyzed. Data were submitted to Tukey test and to paired t-test, and it was observed that the two irradiated composites had a statistically significant reduction in Knoop hardness values when compared to non­irradiated composites adversely, no statically significant differences were found among the irradiated groups. Regarding surface roughness, no statistically significant difference was observed in the comparisons between the control group and irradiated group, however statistically significant differences were found inside each group, before and after the samples have been submitted to abrasion. It was concluded that the x-irradiation influenced the Knoop hardness, therefore it did not interfere on the surface roughness of the two restorative composite evaluated. / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
253

Estudo do envelhecimento de um tubo de raios X por métodos não invasivos

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:12Z (GMT). No. of bitstreams: 0 / O objetivo do presente trabalho foi a avaliação do envelhecimento de um tubo de raios X com anodo de tungstênio utilizado para aplicações de radiodiagnóstico, por meio de aplicação de cargas de acordo com distribuições de cargas de trabalho da realidade brasileira e avaliações periódicas de grandezas associadas à qualidade de radiação produzida. Para o propósito deste trabalho, um sistema clínico com retificação monofásica de onda completa foi utilizado. Para avaliação em longo prazo das características do tubo de raios X relacionadas à carga de trabalho foi necessária a medição de parâmetros que pudessem representar de forma quantitativa o envelhecimento do tubo de raios X, estando estes relacionados principalmente ao desgaste do anodo. Esta medição indireta do envelhecimento do tubo levou a escolha de quatro parâmetros, alguns deles normalmente empregados na prática de controle de qualidade de equipamentos de radiologia diagnóstica: primeira e segunda camada semi-redutora (CSR), dimensões dos pontos focais, medida não invasiva do Potencial de Pico Prático e espectrometria de raios X. Estes parâmetros foram medidos inicialmente e após cada aplicação de carga pertinente. Para garantir a confiabilidade dos resultados, condições de reprodutibilidade foram estabelecidas para cada parâmetro de avaliação. As incertezas envolvidas em todos os processos de medição foram calculadas para avaliação da real contribuição dos efeitos do envelhecimento do tubo de raios X nos parâmetros não invasivos. Dentre os parâmetros avaliados, os que mostraram maior sensibilidade aos efeitos da aplicação de carga em longo prazo foram as energias médias obtidas por meio de espectrometria de raios X e as camadas semi-redutoras. Um modelo relacionado a estes parâmetros foi aplicado e estimativas da taxa de envelhecimento do tubo de raios X para diferentes tensões de aceleração e correntes anódicas foram obtidas. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
254

Ultra-baixo coeficiente de atrito entre o par ceramico Sisub(3)Nsub(4)-Alsub(2)Osub(3) em agua

FERREIRA, VANDERLEI 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:56Z (GMT). No. of bitstreams: 1 12938.pdf: 9953963 bytes, checksum: abe25b7224002370db20a3af3b1f2044 (MD5) / Tese (Doutoramento) / IPEN/T / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
255

Efeito de diferentes desafios sobre as propriedades de superfície dos sistemas restauradores que simulam os tecidos gengivais / Effect of different challenges on the surface properties of restorative systems that simulate gingival tissues

Erika Michele dos Santos Araujo 07 June 2018 (has links)
O uso de compósitos simulando a cor dos tecidos gengivais apresenta-se como uma opção de tratamento restaurador estético com aplicação direta, que pode aumentar a satisfação do paciente por meio de uma solução de baixo custo e pouco invasiva. Este estudo teve como fatores de variação: sistemas restauradores que reproduzem a cor dos tecidos gengivais (Amaris® gingiva (A), NTpremium® Pink (B), Beautifil® II Pink (C) e protocolo de envelhecimento [desafio erosivo (DE) e ciclagem térmica (CT)], avaliados quanto a estabilidade de cor, rugosidade superficial, perda de superfície e quantificação de biofilme. Para os 3 primeiros ensaios, os espécimes foram divididos em 6 grupos (n=10): G1 (A+CT); G2 (A+DE); G3 (B+CT); G4 (B+DE); G5 (C+CT); G6 (C+DE). A ciclagem térmica foi realizada com um total 5.000 ciclos, com banhos de 5ºC e 55ºC e o desafio erosivo consistiu da armazenagem dos espécimes em solução de ácido cítrico 0,3%, com pH 2,5 a 37°C, durante uma semana. Sessenta espécimes de 5mmX5mmX3mm foram montados, fotopolimerizados, polidos e armazenados em estufa a 37º por 24h. Todos os espécimes foram lidos antes e após os protocolos de envelhecimento, utilizando o perfilômetro óptico para avaliação da rugosidade superficial e a perda de superfície, enquanto o espectrofotômetro avaliou a estabilidade de cor dos compósitos, de acordo com os parâmetros do CIELab. Para a quantificação do biofilme foram acrescentadas duas variáveis tempo de leitura (após 3 e 24 horas) e ao protocolo de envelhecimento foi adicionado um grupo controle (sem envelhecimento). Noventa (n=5) espécimes de 4mmX1mm foram montados e padronizados como os espécimes montados para as leitura de rugosidade, perda de superfície e alteração de cor. Para a formação do biofilme foram utilizadas as cepas de Streptococcus mutans UA159, cultivadas em TSB suplementado com 0,5% de sacarose por 3 e 24 horas e mensurados através do método indireto de coloração com safranina e leitura de absorbância para a quantificação do biofilme formado. No que se refere a alteração de cor, detectou-se diferença estatisticamente significante para os fatores sistema restaurador (p=0,00) e para a interação sistema restaurador X protocolo de envelhecimento (p=0,00). A maior variação de cor foi observada no material C quando submetido ao desafio erosivo (16,75±3,25). A ANOVA não detectou diferença estatisticamente significante para nenhum dos fatores em relação a perda de superfície. Na avaliação da rugosidade, detectou-se diferença estatisticamente significante para o fator protocolo de envelhecimento (p=0,00), havendo maior rugosidade para os espécimes submetidos à ciclagem térmica. Na quantificação de biofilme, após 3 e 24 horas, ANOVA detectou diferença estatisticamente significante para o fator protocolo de envelhecimento (p=0,00) e para a interação entre o protocolo de envelhecimento e material restaurador (p=0,00 e p=0,003, respectivamente). Conclui-se que todos os sistemas restauradores apresentaram alteração de cor após os protocolos de envelhecimento testados. A CT foi o protocolo de envelhecimento que mais aumentou a rugosidade em todos os sistemas restauradores, contudo sem perda significante de superfície. A quantificação de biofilme após 3 e 24 horas foi aumentada pelos protocolos de envelhecimento. O desafio erosivo aumentou a deposição de biofilme no sistema restaurador giomer, em 3 e 24 horas. / The use of composites simulating the color of the gingival tissues presents as an option of aesthetic restorative treatment with direct application, which can increase patient satisfaction through a low-cost and non-invasive solution. This study had as factors of variation: restorative systems that reproduce the color of the gingival tissues (Amaris® gingiva (A), NTpremium® Pink (B), Beautifil® II Pink (C) and aging protocols [thermal cycling (TC) and erosive challenge (EC)], evaluated for color stability, surface roughness, surface loss and biofilm quantification. For the first 3 trials, the specimens were divided into 6 groups (n = 10): G1 (A + TC); G2 (A + EC); G3 (B + TC); G4 (B + EC); G5 (C + TC); G6 (C + EC). The thermal cycling was performed with a total of 5.000 cycles, with baths of 5 ° and 55 ° C and the erosive challenge consisted of the storage of the specimens in 0.3% citric acid solution, pH 2.5 at 37°C, for one week. Sixty specimens of 5mmX5mmX3mm were mounted, photopolymerized, polished and stored in destilled water at 37º for 24h. All the specimens were read before and after the aging protocols, using the optical profilometer to evaluate surface roughness and surface loss, while the spectrophotometer evaluated the color stability of the composites, according to CIELab parameters. Two reading time variables (after 3 and 24 hours) were added to the biofilm quantification and a control group (without aging) was added to the aging protocol. Ninety (n=5) specimens of 5mmX1mm were mounted and standardized as the specimens or the first 3 trials, roughness, surface loss and color stability. For the biofilm formation, Streptococcus mutans UA159, cultivated in TSB supplemented with 0.5% of sucrose for 3 and 24 hours and measured by the indirect method of safranin staining and absorbance reading were used. Regarding the color change, a statistically significant difference was detected for the factors restorative system (p=0.00) and for the interaction restorative system X aging protocol (p=0.00). The highest color variation was observed in material C when submitted to erosive challenge (16.75 ± 3.25). ANOVA did not detect a statistically significant difference for any factors in relation to surface loss. In the evaluation of roughness, a statistically significant difference was detected for the aging protocol factor (p=0.00), with a higher roughness for the specimens submitted to thermal cycling. In the biofilm quantification, after 3 and 24 hours, ANOVA detected a statistically significant difference for the aging protocol factor (p=0.00) and for the interaction between the two factors, aging protocols and restorative systems (p=0.00 and p=0.003, respectively). It was concluded that all restorative systems presented color changes after the aging protocols tested. CT was the aging protocol that increased the most roughness in all restorative systems, nevertheless without significant loss of surface. Biofilm deposition after 3 and 24 hours varies considerably depending on the restorative system and aging protocol. The erosive challenge increased biofilm deposition in the restorative system giomer in 3 and 24 hours.
256

Avaliação da estabilidade de cor e rugosidade superficial de resinas compostas micro-híbridas, submetidas ao processo de envelhecimento artificial acelerado, em função da fotoativação com lâmpada halógena e LED / Color stability and surface roughness of micro hybrids resins polymerized by LED or halogen light irradiation after accelerated aging.

Odirlei Arruda Malaspina 14 September 2009 (has links)
O estudo avaliou, in vitro, as variáveis relacionadas à alteração de cor e à rugosidade superficial das resinas compostas micro-híbridas: Charisma (Heraeus-Kulzer), Filtek Z-250 (3M - Espe), Herculite XRV (Kerr), Opallis (FGM), TPH Spectrum (Dentsply) e W3D (Wilcos), antes e após o envelhecimento artificial acelerado, tendo como fatores de variação duas fontes de luz, lâmpada halógena e LED, com densidades de potência de 300 mW/cm2 ou 600 mW/cm2. Foram confeccionados 240 corpos-de-prova distribuídos em grupos de 10 unidades para cada condição de estudo totalizando 24 grupos constituídos por 4 protocolos de fotoativação para cada marca de resina composta. Estes corpos-de-prova foram armazenados em água deionizada, ao abrigo de luz e a temperatura de 37oC por 1 semana quando então receberam polimento superficial com discos Diamondpro (FGM). Sequencialmente, os mesmos foram submetidos às análises iniciais de rugosidade superficial (rugosímetro Hommle Tester T1000 basic) e de cor (Espectrofotômetro EasyShade). Decorridas 24 horas, os espécimes foram submetidos ao Sistema de Envelhecimento Acelerado para materiais não metálicos C-UV por 384 horas quando então foram novamente realizadas as leituras de rugosidade e cor. Os valores de rugosidade superficial e alteração de cor das resinas compostas, após o processo de envelhecimento acelerado, demonstraram alterações significativas, sendo os valores de E muito superiores ao considerado clinicamente aceitável (E3,3). De forma geral, o efeito exercido pelos protocolos de fotoativação não permitiu distinguir a influência direta das irradiâncias das fontes de luz no comportamento das diferentes resinas compostas, observando-se uma correlação positiva média entre rugosidade superficial e a alteração de cor. / This study aimed to evaluate changes in color and surface roughness, before and after artificial accelerated aging of six micro hybrids composites resins (comparable to Vita shade A2) cured by quartz tungsten halogen (H) or a light emitting diode (L) polymerization unit with 300 mW/cm2 or 600 mW/cm2. Forty disc specimens (7 x 2 mm) were prepared for each composite (Charisma®, Filtek Z-250®, Herculite XRV®, Opallis®, TPH Spectrum®, W3D®), being 10 specimens for each condition (Q 300/600 mW/cm2 or L 300/600 mW/cm2). After cured, each specimen was evaluated by color (Easy Shade® spectrophotometer) according to CIE L*a*b* color scale and by surface roughness (Hommelwerke GmbH ) Ra values before and after submitting to artificial accelerated aging (4 h UV-B/4 h condensing vapor) for 384 hours total. The surface roughness and color change values of composite resins, after the process of accelerated aging, showed significant changes. Also, the values of E after accelerated aging were much higher than the values considered clinically acceptable (E 3.3). In general, the protocols curing effects showed varied influence over different composite resins and a positive correlation between average change in surface roughness and color change after accelerated aging process.
257

Influência da rugosidade e energia livre de superfície de materiais para próteses removíveis a base de polimetilmetacrilato nas propriedades do biofilme de Candida albicans / Influence of the roughness and free energy surfasse of the materials for removable prosthesis the base of polymethymethacrylate in the properties of biofilm of Candida albicans

Leal, Cristiane Maria Brasil, 1965- 18 August 2018 (has links)
Orientador: Célia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:42:48Z (GMT). No. of bitstreams: 1 Leal_CristianeMariaBrasil_D.pdf: 1004692 bytes, checksum: 29697b5c7bdbece2ba32ca361de7e805 (MD5) Previous issue date: 2011 / Resumo: As propriedades de superfície de resinas e reembasadores a base de polimetilmetacrilato utilizados em próteses dentais removíveis podem interferir na adesão, colonização e formação do biofilme de Candida spp., microrganismo associado à estomatite protética. O objetivo desta pesquisa foi avaliar a influência da rugosidade e da energia livre de superfície de uma resina a base de polimetilmetacrilato e um reembasador rígido na adesão e estrutura de biofilmes de Candida albicans. Discos de resina acrílica termopolimerizável e de reembasador rígido à base de polimetilmetacrilato foram confeccionados nas dimensões de 10 x 2 mm. As diferentes rugosidades de superfície dos espécimes foram obtidas por meio de diferentes acabamento/polimento. A energia livre de superfície variou pela formação de películas de saliva ou plasma ou a combinação de ambos sobre os espécimes. Após a mensuração da rugosidade e da energia livre de superfície, os espécimes foram divididos aleatoriamente de acordo com os grupos experimentais. Biofilmes de Candida albicans ATCC 90028 foram formados sobre as superfícies e avaliados quanto à contagem celular, bioatividade e arquitetura (bio-volume, espessura média e rugosidade média) nas fases de adesão e após 48 horas. Os dados foram analisados utilizando-se a análise de variância a dois critérios seguido do teste de Tukey. O nível de significância foi de p=0,05. Os resultados revelaram que mesmo havendo diferenças significantes (p<0,001) entre os valores da rugosidade, isto não se refletiu nos parâmetros avaliados do biofilme de C. albicans no período de 48 horas. Não houve diferença significativa nos valores da energia livre de superfície, no entanto, a diferença das películas provocou alterações significativas do biofilme de C. albicans na fase de adesão e 48 horas (p>0,05). Pode-se concluir que a alteração da rugosidade de superfície não afeta a estrutura do biofilme de C. albicans de 48 horas, no entanto, a alteração da energia livre de superfície por meio da deposição de proteínas salivares e/ou plasmáticas altera a estrutura do biofilme nas fases de adesão e 48 horas / Abstract: The properties of surface of the resins and reliners base of polymethymethacrylate used in removable dental prosthesis can interfere in the adhesion, colonization and formation of biofilm of Candida spp., microorganism associated to the prosthetic stomatitis. The objective of this research was to evaluate the influence of the roughness and the free energy of surface of the resin the base of polymethymethacrylate and a rigid reliner in the adhesion and structure of biofilms of C. albicans. Discs of the termopolymerized acrylic resin and rigid reliner to the base of polymethymethacrylate had been confectioned in the dimensions 10 x 2 mm. The differents roughness of surface of the specimens were obtained by means of different finishing/polishing. The free energy of surface varied for the formation of pellicle of saliva or serum or the combination of both on the specimens. After the measurement the roughness and the free energy of surface, the specimens were divided randomly in accordance to the experimental groups. Biofilms of Candida albicans ATCC 90028 were formed on the surfaces and evaluated for cell count, bioactivity and architecture (bio-volume, average thickness and average roughness) in the adhesion phases and after 48 hours. The data were analyzed using analysis of variance with two criteria followed by the Tukey test. The significance level was p=0,05. The results showed that even with significant differences (p<0.001) between the values of roughness, it did not reflect in the parameters evaluated of biofilm of C. albicans in 48 hours. There was no significant difference in the values of the free energy of surface; however, the difference of the pellicles caused significant alterations of biofilm of C. albicans in the adhesion phase and 48 hours (p>0,05). It can be concluded that the alteration of the roughness of surface don't affect the structure of biofilm of C. albicans of 48 hours, however, the alteration of the free energy of surface by deposition of salivary and/or serum proteins modifies the structure of biofilm in the adhesion phases and 48 hours / Doutorado / Protese Dental / Doutor em Clínica Odontológica
258

Degradação de materiais restauradores estéticos em um modelo de ciclagem de ph e abrasão por escovação / Degradation of esthetic restorative materials in a pH cycling model and toothbrush abrasion

Davidoff, Denise Cesar de Oliveira, 1962- 18 August 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T23:48:30Z (GMT). No. of bitstreams: 1 Davidoff_DeniseCesardeOliveira_D.pdf: 3958488 bytes, checksum: 9a1e41592f3bdc48fc01bc4174934e72 (MD5) Previous issue date: 2011 / Resumo: Os objetivos nesta tese, composta por 2 capítulos foram: (1) avaliar a influencia da proteção de superfície na dureza, rugosidade e morfologia de um cimento de ionômero de vidro submetidos a degradação química e mecânica; (2) avaliar os efeitos do desafio químico (ciclagem de pH) e mecânico (abrasão por escovação) na dureza e rugosidade de diferentes materiais restauradores. No capitulo 1, trinta e seis espécimes obtidos do CIV foram distribuídos em 4 grupos (n=8) de acordo com a proteção de superfície (com ou sem proteção de vaselina) e meio de armazenagem (ciclagem de pH e água deionizada). Todos os espécimes foram submetidos a mensuração de microdureza e rugosidade de superfície (Ra) em três momentos inicial, apos armazenagem por 15 dias e apos abrasão por escovação mecânica. Os dados foram submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey-Kramer (p<0,05). Os resultados de ciclagem de pH evidenciaram que houve diminuição dos valores de dureza independente do fator proteção. A ciclagem de pH não promoveu alteração nos valores de rugosidade para o grupo sem proteção. O cimento de ionômero de vidro de alta viscosidade apresentou diminuição na dureza apos abrasão e ciclagem de pH independente da proteção de superfície com vaselina. No capitulo 2, foram confeccionados dezesseis espécimes de cada material (Ketac Molar Easy Mix, Vitremer, Ketac N100 e Filtek Z350) divididos em 8 grupos (n=8) de acordo com o material e o meio de armazenagem: ciclagem de pH e água deionizada. Foram mensuradas a microdureza e rugosidade de superfície de todos os materiais estudados em três momentos: inicial, apos armazenagem por 15 dias e apos abrasão por escovação mecânica. Os dados foram submetidos a ANOVA 3 fatores para medidas repetidas e teste de Tukey-Kramer (p<0,05). Os resultados mostraram que todos os materiais avaliados apresentaram diminuição dos valores de dureza apos ciclagem de pH. O Filtek Z350 apos abrasão apresentou os maiores valores de dureza, e os demais materiais valores equivalentes. O Ketac N100 não apresentou alteração na dureza quando submetido a abrasão e ciclagem de pH. O Ketac Molar Easy Mix não apresentou alteração nos valores de rugosidade apos degradação química e mecânica, enquanto os Ketac N100, Filtek Z350 e Vitremer apresentaram aumento de rugosidade. Com base nos resultados pode-se concluir que a influencia da abrasão por escovação mecânica e da ciclagem de pH na degradação de superfície dos materiais restauradores estéticos esta relacionada ao tipo de material: o compósito Filtek Z350 foi o material que exibiu a maior resistência a degradação química e mecânica em relação a rugosidade e dureza, apresentando menores índices de rugosidade. O Ketac N100 apresentou valores equivalentes de dureza e rugosidade ao Vitremer apos abrasão e ciclagem de pH. O Ketac Molar Easy Mix apresentou diminuição na dureza apos abrasão e ciclagem de pH, independente da proteção superficial com vaselina. O Ketac Molar Easy Mix sem proteção superficial com vaselina não apresentou diminuição de rugosidade apos abrasão associada a ciclagem de pH / Abstract: The objectives of this Thesis, consisting of two chapters, were: (1) to evaluate the effect of petroleum jelly used as a surface protection on hardness and surface roughness of Ketac Molar Easy Mix (KM), submitted to chemical and mechanical degradation; (2) to evaluate the effect of chemical challenges (pH-cycling) and mechanical degradation (toothbrush abrasion) in hardness and roughness surface of different restorative materials. In chapter one, thirty-two specimens obtained from KM were divided into four groups according to their surface protection (with or without protection) and chemical degradation (pH cycling or water). All specimens were subjected to measurement of microhardness and surface roughness at baseline, after storage and after abrasion. Data were submitted to a three-way ANOVA for repeated measures and Tukey-Kramer's tests (p<0.05). After pH cycling, there was a decrease in hardness regardless the surface protection. The pH cycling did not promote changes in surface roughness for the group without protection. KM showed a decrease in hardness and abrasion after pH cycling, independently of surface protection. pH-cycling provided the lowest microhardness regardless surface protection or abrasion. The highest microhardness point was obtained when KM was protected and submitted to water storage and abrasion. The highest roughness point was obtained when unprotected KM was submitted to water immersion and/or abrasion compared with KM and submitted to pH cycling. Conclusion: Microhardness and surface roughness were influenced by surface protection and chemical degradation. There was an increase in surface roughness when KM was unprotected. In chapter 2, sixteen specimens were obtained from each material (Ketac Molar Easy Mix, Vitremer, Ketac N100 and Filtek Z350) and were divided into 8 groups according to the material and the storage. All specimens were submitted to the measurement of hardness and roughness in three different treatments: initial, after storage and after abrasion. The data were submitted to repeated measures three-way ANOVA and Tukey's tests (p<0.05). Results showed that all materials presented a decrease in hardness after pH cycling. The Filtek Z350 after abrasion presented the highest surface hardness and the others did not present statistically significant difference. The Ketac N100 was the only material that showed no change in hardness when submitted to pH cycling and abrasion, while the others, KM, Vitremer and Filtek Z350, showed a decrease in hardness. The KM did not change the roughness after chemical and mechanical degradation, while Ketac N100, Filtek Z350 and Vitremer increased surface roughness. Filtek Z350 was the material that showed the best resistance to chemical and mechanical degradation. Based on the results it can be concluded that the influence of abrasion and pH cycling on surface degradation of aesthetic restorative materials is related to the type of material: Filtek Z350 exhibited the highest resistance to chemical and mechanical degradation concerning roughness and hardness. Ketac N100 and Vitremer showed similar values of hardness and roughness after abrasion and pH cycling. KM had a decrease in hardness and abrasion after pH cycling, independently of surface protection. KM with no surface protection did not show a decrease of roughness after abrasion associated with pH cycling / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
259

Low coherence interferometry and optical coherence tomography in paper measurements

Alarousu, E. (Erkki) 14 November 2006 (has links)
Abstract This thesis describes the application of Low Coherence Interferometry (LCI) and Optical Coherence Tomography (OCT) in paper measurements. The developed measurement system is a combination of a profilometer and a tomographic imaging device, which makes the construction versatile and applicable in several paper measurement applications. The developed system was first used to measure the surface structure of paper. Different grades of paper were selected to provide maximum variation in surface structure. The results show that the developed system is capable of measuring grades of paper from rough base paper to highly coated photo printing paper. To evaluate the developed system in surface characterization, the roughness parameters of five laboratory-made paper samples measured with the developed system and with a commercial optical profilometer were compared. A linear correlation was found with roughness parameters Ra and Rq. Next, the surface quality of paper was evaluated using LCI, a Diffractive Optical Element Based Glossmeter (DOG), and a commercial glossmeter. The results show linear correlation between Ra and gloss measured with the commercial glossmeter. The roughness Ra and averaged gloss measured with the DOG didn't give such a correlation, but a combination of these techniques provided local properties of gloss and surface structure, which can be used to evaluate the local surface properties of paper. In the next study, determination of the filler content of paper using OCT is discussed. The measurement results show clear correspondence of the slope of the averaged logarithmic fringe signal envelope and the filler content. The last studies focus on 2D and 3D imaging of paper using OCT and begin with imaging of a self-made wood fiber network. The visibility of the fibers was clear. Next, several refractive index matcing agents are studied by means of light transmittance and OCT measurements to find the best possible agent for enhancing the imaging depth of OCT in paper. Benzyl alcohol was found to have the best possible combination of optical, evaporation, and sorption characteristics, and it is applied in 2D and 3D visualizations of copy paper.
260

Contact unilatéral de surfaces périodiquement rugueuses : modélisation et simulation / Unilateral contact of periodically rough surfaces : modelling and simulation

Houanoh, Karim 30 January 2017 (has links)
Le contact unilatéral entre deux surfaces est un phénomène omniprésent en physique, en mécanique et en génie civil. Une surface nominalement lisse à l’échelle macroscopique est en réalité rugueuse à l’échelle microscopique. La présence de rugosités modifie considérablement la distribution des contraintes et le champ des déformations au voisinage des surfaces en contact. La prise en compte de rugosités surfaciques à l’échelle microscopique constitue souvent une clé pour appréhender et modéliser un grand nombre de phénomènes d’interface/surface observés à l’échelle macroscopique, tels que le frottement, l’adhésion, l’usure et la conductivité thermique ou électrique. Ce travail de thèse porte sur le contact unilatéral de deux demi-espaces dont les surfaces sont périodiquement rugueuses. Dans la première partie du travail où les deux demi-espaces sont constitués de deux matériaux linéairement élastiques, une approche numérique simple et efficace est proposée et élaborée en se basant sur la méthode des éléments de frontière et la méthode d’inversion matricielle et en exploitant la périodicité du problème en question. Cette approche numérique est d’abord comparée avec et validée par des résultats analytiques et ensuite appliquée à plusieurs cas d’intérêt pratique. Dans les deuxième et troisième parties du travail, l’approche numérique proposée dans le cas élastique est étendue aux cas où les demi-espaces sont formés de matériaux d’abord linéairement thermoélastiques et ensuite linéairement viscoélastiques. Des résultats analytiques existants dans ces deux cas sont utilisés comme benchmarks pour tester la précision et l’efficacité des approches résultantes. Des exemples numériques sont donnés pour mettre en évidence des phénomènes physiques / Unilateral contact between two surfaces is a phenomenon often present in physics, mechanics and civil engineering. A nominally smooth surface on a macroscopic scale is actually rough on the microscopic scale. The presence of surficial roughness considerably modifies the stress distribution and the strain field in the vicinity of the surfaces in contact. Consideration of surficial roughness at the microscopic scale is often a key to understanding and modeling a large number of macroscopic interface/surface phenomena such as friction, adhesion, wear and thermal or electrical conduction. This work focuses on the unilateral contact of two half-spaces whose surfaces are periodically rough. In the first part of the work where the two half-spaces consist of two linearly elastic materials, a simple and efficient numerical approach is proposed and elaborated on the basis of the boundary element method and the matrix inversion method and by exploiting the periodicity of the problem in question. This numerical approach is first compared with and validated by available analytical results and then applied to several cases of practical interest. In the second and third parts of the work, the numerical approach proposed in the elastic case is extended to cases where the half-spaces are formed of materials that are first linearly thermoelastic and then linearly viscoelastic. Some existing analytical results in these two cases are used as benchmarks to test the accuracy and efficiency of the resulting approaches. Numerical examples are given to bring out some physical phenomena

Page generated in 0.0577 seconds