• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 8
  • 8
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Novel semiconductor based broadly tunable light sources

Fedorova, Ksenia Alexandrovna January 2011 (has links)
The development of compact and low-cost coherent sources in visible and infrared wavelength range can provide indispensible tools for a variety of scientific, technological and industrial applications. Great progress over the last years in material science, crystal growth and semiconductor material processing in combination with recent advances in some of the more traditional technologies, in particular nonlinear frequency conversion and parametric sources, have led to the realisation of a new generation of laser sources. Furthermore, the advent of a new generation of quasi-phase-matched, waveguided and semiconductor nonlinear materials together with novel semiconductor lasers have led to the development of new frequency conversion and parametric sources with previously unattainable performance capabilities. The research described in this thesis relates to the development and characterisation of novel semiconductor based laser sources tunable in the broad spectral ranges which are unattainable for conventional lasers due to a lack of suitable laser gain materials. In the first part of the thesis the subject matter is concerned with the direct emission from laser devices. In particular, a broadly tunable InGaAs/InP strained multi-quantum well external cavity diode laser, operating in the spectral range of 1494 nm – 1667 nm with a maximum CW output power in excess of 81 mW and side-mode suppression ratio higher than 50 dB is demonstrated. This represents the highest output power and side-mode suppression ratio ever to be generated in this spectral region. A record broadly tunable high-power external cavity InAs/GaAs quantum-dot diode laser with a tuning range of 202 nm (1122 nm - 1324 nm), a maximum output power of 480 mW and a side-mode suppression ratio greater than 45 dB, is also demonstrated. This represents a promising achievement for the development of a high-power fast swept tunable laser and compact nonlinear frequency generation schemes for the green-yellow-orange-red spectral range. The second part of the thesis relates to induced nonlinear processes, focusing on frequency doubling and optical parametric oscillation. In particular, an all-room-temperature CW second harmonic generation at 612.9 nm and 591.5 nm in periodically poled potassium titanyl phosphate waveguides pumped by a broadly-tunable quantum-dot external cavity diode laser with a conversion efficiency of 10.5% and 7.9%, respectively, is demonstrated. For the first time, a green-to-red tunable laser source with tunability of over 60 nm (567.7 nm – 629.1 nm) based on frequency doubling in a single periodically poled potassium titanyl phosphate waveguide pumped by a single broadly-tunable quantum dot laser is demonstrated. These results are an important step towards a compact tunable coherent visible light source, operating at room temperature. The possibility of nonlinear frequency conversion in orientation-patterned GaAs waveguides is also investigated. The technology of low-loss periodically poled GaAs waveguided crystals is developed and such crystals are fabricated. Second harmonic generation at 1621 nm in low-loss periodically poled GaAs waveguide is demonstrated. An optical parametric oscillator system used as the pump source for GaAs devices and based on the periodically poled 5 mol% MgO-doped Congruent Lithium Niobate crystal, generating light in the wavelength range between 1430 nm and 4157 nm, is presented. The obtained results show a great promise for realisation of efficient quasi-phase-matched optical parametric oscillator devices based on orientation-patterned GaAs waveguides, which enables the extending generated wavelength up to 16 µm.
2

Photonics and optoelectronics using 1D and 2D materials

Yang, Zongyin January 2019 (has links)
No description available.
3

Versatile Chromium-Doped Zinc Selenide Infrared Laser Sources

Berry, Patrick A. 05 May 2010 (has links)
No description available.
4

Development and application of tunable VUV laser sources

Nortje, Anton Christiaan 03 1900 (has links)
Thesis (MSc)--Stellenbosch University, 2013. / ENGLISH ABSTRACT: A tunable narrow-bandwidth vacuum ultra violet laser source was developed and characterised. Two-photon resonant four-wave sum-frequency mixing of two pulsed dye laser beams in magnesium vapour was used to generate the VUV laser light. A heat pipe oven with a concentric design was incorporated to provide a magnesium vapour column of around 30 cm in length with a sufficiently stable temperature and appropriate vapour pressure for efficient VUV production. This is a longer nonlinear medium length than previously produced in our laboratory using a crossed heat pipe oven. The longer medium facilitated the production of VUV laser light of higher intensity than was previously obtainable. High resolution laser induced fluorescence spectra of carbon monoxide in a supersonic gas jet was recorded using the tunable VUV laser light produced in the crossed heat pipe oven. Experimental parameters were optimised and adjusted for the selective detection of the forbidden singlet-triplet transitions which typically have longer lifetimes than singlet-singlet transitions. Transitions from the X¹Σ⁺(v = 0) ground state to the e³Σ⁻( v = 5) triplet state were recorded, and accurate wavelength for the spectral lines were determined. Laboratory wavelengths for these lines have not been measured previously. Accurate wavelength for the weak forbidden spectral lines of CO are important in astrophysical applications, for example determining column densities of interstellar gas clouds. / AFRIKAANSE OPSOMMING: 'n Afstembare smal bandwydte vakuum ultraviolet laser bron is ontwikkel en gekarakteriseer. Twee-foton resonante vier-golf som-frekwensie vermenging van twee gepulseerde kleurstoflaserbundels in 'n magnesium damp is gebruik om die VUV laser lig te produseer. 'n Hittepyp oond met 'n konsentriese ontwerp is in gebruik geneem om a magnesium damp kollom van ongeveer 30 cm in lengte te voorsien waarvan die temperatuur voldoende stabiel is en die dampdruk toepaslik is vir effektiewe VUV produksie. Dit is 'n langer nie-liniêre medium as wat in die verlede deur 'n kruis-hittepyp oond voorsien is. Die langer medium het dit moontlik gemaak om VUV laser lig van hoër intensiteit te produseer as wat tot dusver bereikbaar was. Hoë resolusie laser geinduseerde fluoresensie spektra van koolstof monoksied in a supersoniese gasstraal is opgeneem met die hulp van die afstembare VUV laser lig geproduseer in die kruis-hittepyp oond. Eksperimentele parameters is geoptimeer en verstel vir die selektiewe waarneming van die verbode singlet-triplet oorgange wat tipies langer leeftye besit in vergelyking met singlet-singlet oorgange. Oorgange vanaf die X¹Σ⁺(v = 0) grond toestand na die e³Σ⁻( v = 5) triplet toestand is opgeneem en akkurate golflengtes vir die spektrale lyne is bepaal. Laboratorium golflengtes het tot dusver nie bestaan vir hierdie lyne nie. Akkurate golflengtes vir die swak verbode spektrale lyne van CO het belangrike toepassings in astrofisika soos die bepaling van die kollom digtheid van interstellêre gas wolke.
5

Construção de um laser de centro de cor para aplicações em espectroscopia. / Development of a color center laser for spectroscopy application.

Woehl Junior, Germano 23 June 1986 (has links)
O objetivo deste trabalho é o desenvolvimento de um laser de centro de cor para aplicações em espectroscopia. O laser opera em regime CW e a cavidade óptica utilizada é do tipo X, com dois espelhos esféricos intracavidade astigmáticamente compensados. O meio ativo utilizado foi um cristal de KCl:Li+ com centros FA (II), e como fonte de bombeamento foi empregado um laser de Ar+ em 514nm. O limiar de potência de bombeamento foi de 120 mW, a eficiência energética foi de 2,8% e o intervalo de sintonia obtido vai de 2,56 a 2,82 &#956m numa potência de bombeamento de 700mW. O laser opera também com a cavidade na configuração anel. Para testar o LCC foram feitas aplicações empregando a técnica de espectroscopia intercavidade em cristais de KCl: Li+: NO-2: NO-3 e KBr:OH-. / The present work shows the development of a color Center laser for spectroscopy application. It is a CW laser which uses an X-type cavity with two astigmatically compensated intracavity spherical mirrors. The laser can be converted to a ring laser. The used active medium was a KCl:Li+ single crystal with a FA (II) centers and the pumping source was an Ar+ laser (&#955= 514nm, 700mW). Pump power at threshold was measured to be 120mW. The tuning range was 2.56&#60 &#955 &#60 2.82 &#956m and the slope efficiency was 2,8%. To test the color center laser we measured intracavity spectra of KCl: Li+: NO-2: NO-3 and KBr:OH- single crystals.
6

Construção de um laser de centro de cor para aplicações em espectroscopia. / Development of a color center laser for spectroscopy application.

Germano Woehl Junior 23 June 1986 (has links)
O objetivo deste trabalho é o desenvolvimento de um laser de centro de cor para aplicações em espectroscopia. O laser opera em regime CW e a cavidade óptica utilizada é do tipo X, com dois espelhos esféricos intracavidade astigmáticamente compensados. O meio ativo utilizado foi um cristal de KCl:Li+ com centros FA (II), e como fonte de bombeamento foi empregado um laser de Ar+ em 514nm. O limiar de potência de bombeamento foi de 120 mW, a eficiência energética foi de 2,8% e o intervalo de sintonia obtido vai de 2,56 a 2,82 &#956m numa potência de bombeamento de 700mW. O laser opera também com a cavidade na configuração anel. Para testar o LCC foram feitas aplicações empregando a técnica de espectroscopia intercavidade em cristais de KCl: Li+: NO-2: NO-3 e KBr:OH-. / The present work shows the development of a color Center laser for spectroscopy application. It is a CW laser which uses an X-type cavity with two astigmatically compensated intracavity spherical mirrors. The laser can be converted to a ring laser. The used active medium was a KCl:Li+ single crystal with a FA (II) centers and the pumping source was an Ar+ laser (&#955= 514nm, 700mW). Pump power at threshold was measured to be 120mW. The tuning range was 2.56&#60 &#955 &#60 2.82 &#956m and the slope efficiency was 2,8%. To test the color center laser we measured intracavity spectra of KCl: Li+: NO-2: NO-3 and KBr:OH- single crystals.
7

Fiber Bragg Grating Interrogation Systems

Yamdagni, Sumeet 01 1900 (has links)
This thesis work deals with the development of three different categories of interrogation techniques for Fiber Bragg Grating based sensor networks. Such networks are used for structural health monitoring and other applications. A bulk grating based interrogation system is described first, which includes an optical source, switch, circulator, embedded controller, and software. The center wavelength determination technique employed is detailed and is shown to be highly accurate from test data. The comparison with resistance strain gauges is presented which shows that the system developed provides an accurate strain reconstruction. The system is also compared with a commercial optical spectrum analyzer and is found to exhibit good accuracy and fidelity. The system has been field tested on an aircraft structure with 14 sensors spread over 4 channels. Strain data reconstruction from these tests is shown to accurately reproduce the loading conditions. A second system developed is based on the matched filter technique using a mechanical fiber stretcher; the details of this system are presented with a mathematical treatment of the technique. The design of the fiber stretcher is also described. This design is regarded to be novel since it tries to provide large interrogation bandwidths using a parallel topology. The results of tests have shown good resolution and comparative tests with resistance strain gauges have shown accurate reproduction of strain. Finally, an interrogation system based on a wavelength tunable source is presented. This system is a precursor to a time division multiplexed interrogation system, which has also been described. Three laser configurations have been set up and characterized. The laser sweep tests have been performed on two configurations and a sensor grating reconstruction test has also been carried out.
8

[pt] FONTES ÓPTICAS PARA TOMOGRAFIA DE COERÊNCIA ÓPTICA DE ALTA RESOLUÇÃO / [en] OPTICAL SOURCES FOR HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHY

ANDREW HENRY CORDES 10 November 2021 (has links)
[pt] Foram desenvolvidas fontes ópticas para obtenção de imagens por tomografia de coerência óptica com alta resolução. Dois tipos de abordagens foram realizados, uma com um laser contínuo sintonizável, que neste trabalho foi instrumentado com marcadores de frequência óptica, outra com uma fonte óptica pulsada de banda larga. Mediante um processo de calibricação desenvolvido neste trabalho, a fonte contínua forneceu resoluções de 8 μm e alcances até 0,5 mm, enquanto que a fonte pulsada forneceu resoluções de 3 μm e alcances de 300 μm. A fonte pulsada permitiu ainda a obtenção de imagens em tempo real com capacidade de captura de movimento do objeto. / [en] Optical sources to obtain images through high resolution optical coherence tomography were developed. Two approaches were taken, one with a continuously tunable external cavity laser which, in this work, was modified to produce optical frequency markers, the other with an ultra-wideband pulsed source. Using a calibration process we developed in this work the continuously tunable source continued to achieve resolutions 8 μm and ranges of 0.5 mm, while the pulsed source achieved resolutions of 3.3 μm and ranges of 300 μm. The pulsed source has the capacity to capture real time images.

Page generated in 0.0391 seconds