• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2128
  • 1080
  • 328
  • 180
  • 102
  • 89
  • 48
  • 42
  • 34
  • 27
  • 12
  • 11
  • 8
  • 8
  • 7
  • Tagged with
  • 5350
  • 5350
  • 1693
  • 873
  • 804
  • 636
  • 602
  • 568
  • 567
  • 543
  • 467
  • 429
  • 375
  • 366
  • 354
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Biochemical and structural characterisation of a thermophilic Aldo-Keto Reductase from Thermotoga maritima

Simon, Willies January 2009 (has links)
The Aldo-Keto Reductases (AKR) are a group of oxidoreductase enzymes structurally and mechanistically distinct from the Alcohol Dehydrogenases (ADH). The AKRs are of importance for their ability to produce industrially useful compounds including chiral secondary alcohols. The ADH family have traditionally been exploited for chiral alcohol production; the AKR family have currently been underexploited for chiral alcohol production and present the opportunity to search for novel oxidoreductases with properties and substrate specificities distinct from the ADH enzymes. The AKR studied here, from the hyperthermophilic bacteria Thermotoga maritima has been characterised with respect to its biochemical and structural properties, and its potential as a biocatalyst evaluated. This enzyme is the second example of a thermophilic AKR to have its three dimensional structure solved, the other also being from Thermot. maritima. The AKR studied exhibits high stability with respect to temperature and moderate amounts of organic solvents. A large preference for the reduction reaction compared to the oxidation reaction was found, which has previously been observed in other AKRs. The X-ray crystal structure was solved to 2.6Å resolution in the apo form. The final structure has three loop sections which were not located due to disorder within the crystal, which are expected to become ordered upon cofactor and substrate binding. A section of one of these missing loops was found to bind at the active site of the enzyme, with a glutamate occupying the site of substrate carbonyl binding. The formation of a dimer, increased helix-dipole stabilisation and long distance ion pair interactions all act to increase thermostability of the AKR with respect to its mesophilic homologues. The X-ray crystal structure of Escherichia coli bacterioferritin has also been solved to 1.9Å resolution, which was co-purified along with the recombinant AKR enzyme. This structure shows the symmetrical binding of a heme molecule on the local two-fold axis between subunits and the binding of two metal atoms to each subunit at the ferroxidase centre. These metal atoms have been identified as zinc by the anaylsis of the structure and X-ray data and confirmed by microPIXE experiments. For the first time the heme has been shown to be linked to the internal and external environments via a cluster of waters positioned above the heme molecule. This information has provided a greater insight into the function and mechanism of bacterioferritin.
432

Characterizing the spatial properties of high harmonic generation

Lloyd, David T. January 2014 (has links)
This thesis is concerned with describing a novel technique for characterizing the (spectrally resolved) spatial properties of light. The new approach, known as Scanning Interference Method for Integrated Transverse Analysis of Radiation (SCIMITAR), is a specific implementation of a variable-separation two-pinhole interferometer. Evaluation of the series of interference patterns produced by a SCIMITAR measurement allows the transverse profiles of intensity and spatial phase to be retrieved, while at the same time characterizing the spatial coherence of light. Including a diffraction grating in the simple experimental arrangement permits the spectral dependence of the aforementioned quantities to be measured. The SCIMITAR technique was demonstrated by characterizing the spatial properties of high harmonic generation (HHG). Excellent agreement with an alternate characterization technique known as SWORD was observed. The spectral dependence of the harmonic spatial properties was also investigated. Evidence suggesting absorption may play a role in shaping the harmonic intensity and spatial coherence was presented. Treating the harmonic radiation as either a fully coherent or partially coherent beam allowed the intensity width, spatial phase curvature and coherence width of the harmonic radiation source to be deduced. Measurement of the fine variation of the harmonic complex coherence factor (CCF) with pinhole separation revealed distinctive modulations. The Van Cittert-Zernike theorem was modified by including a Gerchberg-Saxton inspired improvement, allowing data missing from the SCIMITAR measurement to be inferred. The harmonic equivalent incoherent source intensity profile was found to be asymmetric with low intensity features isolated away from the optical axis. Calculations of the diffraction pattern produced by illumination of a non-redundant array of pinholes showed that the modulated harmonic properties could adversely influence lensless imaging-type experiments.
433

Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems

Solomon, Justin Bennion January 2016 (has links)
<p>X-ray computed tomography (CT) imaging constitutes one of the most widely used diagnostic tools in radiology today with nearly 85 million CT examinations performed in the U.S in 2011. CT imparts a relatively high amount of radiation dose to the patient compared to other x-ray imaging modalities and as a result of this fact, coupled with its popularity, CT is currently the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the relationship between dose and image quality. All things being held equal, reducing the dose degrades image quality and can impact the diagnostic value of the CT examination. </p><p>A recent push from the medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose reduction potential of these new technologies in an objective and rigorous manner. Establishing these dose reduction potentials requires precise and clinically relevant metrics of CT image quality, as well as practical and efficient methodologies to measure such metrics on real CT systems. The currently established methodologies for assessing CT image quality are not appropriate to assess modern CT scanners that have implemented those aforementioned dose reduction technologies.</p><p>Thus the purpose of this doctoral project was to develop, assess, and implement new phantoms, image quality metrics, analysis techniques, and modeling tools that are appropriate for image quality assessment of modern clinical CT systems. The project developed image quality assessment methods in the context of three distinct paradigms, (a) uniform phantoms, (b) textured phantoms, and (c) clinical images.</p><p>The work in this dissertation used the “task-based” definition of image quality. That is, image quality was broadly defined as the effectiveness by which an image can be used for its intended task. Under this definition, any assessment of image quality requires three components: (1) A well defined imaging task (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).</p><p>First, this task-based image quality paradigm was implemented using a novel multi-sized phantom platform (with uniform background) developed specifically to assess modern CT systems (Mercury Phantom, v3.0, Duke University). A comprehensive evaluation was performed on a state-of-the-art CT system (SOMATOM Definition Force, Siemens Healthcare) in terms of noise, resolution, and detectability as a function of patient size, dose, tube energy (i.e., kVp), automatic exposure control, and reconstruction algorithm (i.e., Filtered Back-Projection– FPB vs Advanced Modeled Iterative Reconstruction– ADMIRE). A mathematical observer model (i.e., computer detection algorithm) was implemented and used as the basis of image quality comparisons. It was found that image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose (increase in detectability index by up to 163% depending on iterative strength). The use of automatic exposure control resulted in more consistent image quality with changing phantom size.</p><p>Based on those results, the dose reduction potential of ADMIRE was further assessed specifically for the task of detecting small (<=6 mm) low-contrast (<=20 HU) lesions. A new low-contrast detectability phantom (with uniform background) was designed and fabricated using a multi-material 3D printer. The phantom was imaged at multiple dose levels and images were reconstructed with FBP and ADMIRE. Human perception experiments were performed to measure the detection accuracy from FBP and ADMIRE images. It was found that ADMIRE had equivalent performance to FBP at 56% less dose.</p><p>Using the same image data as the previous study, a number of different mathematical observer models were implemented to assess which models would result in image quality metrics that best correlated with human detection performance. The models included naïve simple metrics of image quality such as contrast-to-noise ratio (CNR) and more sophisticated observer models such as the non-prewhitening matched filter observer model family and the channelized Hotelling observer model family. It was found that non-prewhitening matched filter observers and the channelized Hotelling observers both correlated strongly with human performance. Conversely, CNR was found to not correlate strongly with human performance, especially when comparing different reconstruction algorithms.</p><p>The uniform background phantoms used in the previous studies provided a good first-order approximation of image quality. However, due to their simplicity and due to the complexity of iterative reconstruction algorithms, it is possible that such phantoms are not fully adequate to assess the clinical impact of iterative algorithms because patient images obviously do not have smooth uniform backgrounds. To test this hypothesis, two textured phantoms (classified as gross texture and fine texture) and a uniform phantom of similar size were built and imaged on a SOMATOM Flash scanner (Siemens Healthcare). Images were reconstructed using FBP and a Sinogram Affirmed Iterative Reconstruction (SAFIRE). Using an image subtraction technique, quantum noise was measured in all images of each phantom. It was found that in FBP, the noise was independent of the background (textured vs uniform). However, for SAFIRE, noise increased by up to 44% in the textured phantoms compared to the uniform phantom. As a result, the noise reduction from SAFIRE was found to be up to 66% in the uniform phantom but as low as 29% in the textured phantoms. Based on this result, it clear that further investigation was needed into to understand the impact that background texture has on image quality when iterative reconstruction algorithms are used.</p><p>To further investigate this phenomenon with more realistic textures, two anthropomorphic textured phantoms were designed to mimic lung vasculature and fatty soft tissue texture. The phantoms (along with a corresponding uniform phantom) were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Scans were repeated a total of 50 times in order to get ensemble statistics of the noise. A novel method of estimating the noise power spectrum (NPS) from irregularly shaped ROIs was developed. It was found that SAFIRE images had highly locally non-stationary noise patterns with pixels near edges having higher noise than pixels in more uniform regions. Compared to FBP, SAFIRE images had 60% less noise on average in uniform regions for edge pixels, noise was between 20% higher and 40% lower. The noise texture (i.e., NPS) was also highly dependent on the background texture for SAFIRE. Therefore, it was concluded that quantum noise properties in the uniform phantoms are not representative of those in patients for iterative reconstruction algorithms and texture should be considered when assessing image quality of iterative algorithms.</p><p>The move beyond just assessing noise properties in textured phantoms towards assessing detectability, a series of new phantoms were designed specifically to measure low-contrast detectability in the presence of background texture. The textures used were optimized to match the texture in the liver regions actual patient CT images using a genetic algorithm. The so called “Clustured Lumpy Background” texture synthesis framework was used to generate the modeled texture. Three textured phantoms and a corresponding uniform phantom were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Images were reconstructed with FBP and SAFIRE and analyzed using a multi-slice channelized Hotelling observer to measure detectability and the dose reduction potential of SAFIRE based on the uniform and textured phantoms. It was found that at the same dose, the improvement in detectability from SAFIRE (compared to FBP) was higher when measured in a uniform phantom compared to textured phantoms.</p><p>The final trajectory of this project aimed at developing methods to mathematically model lesions, as a means to help assess image quality directly from patient images. The mathematical modeling framework is first presented. The models describe a lesion’s morphology in terms of size, shape, contrast, and edge profile as an analytical equation. The models can be voxelized and inserted into patient images to create so-called “hybrid” images. These hybrid images can then be used to assess detectability or estimability with the advantage that the ground truth of the lesion morphology and location is known exactly. Based on this framework, a series of liver lesions, lung nodules, and kidney stones were modeled based on images of real lesions. The lesion models were virtually inserted into patient images to create a database of hybrid images to go along with the original database of real lesion images. ROI images from each database were assessed by radiologists in a blinded fashion to determine the realism of the hybrid images. It was found that the radiologists could not readily distinguish between real and virtual lesion images (area under the ROC curve was 0.55). This study provided evidence that the proposed mathematical lesion modeling framework could produce reasonably realistic lesion images.</p><p>Based on that result, two studies were conducted which demonstrated the utility of the lesion models. The first study used the modeling framework as a measurement tool to determine how dose and reconstruction algorithm affected the quantitative analysis of liver lesions, lung nodules, and renal stones in terms of their size, shape, attenuation, edge profile, and texture features. The same database of real lesion images used in the previous study was used for this study. That database contained images of the same patient at 2 dose levels (50% and 100%) along with 3 reconstruction algorithms from a GE 750HD CT system (GE Healthcare). The algorithms in question were FBP, Adaptive Statistical Iterative Reconstruction (ASiR), and Model-Based Iterative Reconstruction (MBIR). A total of 23 quantitative features were extracted from the lesions under each condition. It was found that both dose and reconstruction algorithm had a statistically significant effect on the feature measurements. In particular, radiation dose affected five, three, and four of the 23 features (related to lesion size, conspicuity, and pixel-value distribution) for liver lesions, lung nodules, and renal stones, respectively. MBIR significantly affected 9, 11, and 15 of the 23 features (including size, attenuation, and texture features) for liver lesions, lung nodules, and renal stones, respectively. Lesion texture was not significantly affected by radiation dose.</p><p>The second study demonstrating the utility of the lesion modeling framework focused on assessing detectability of very low-contrast liver lesions in abdominal imaging. Specifically, detectability was assessed as a function of dose and reconstruction algorithm. As part of a parallel clinical trial, images from 21 patients were collected at 6 dose levels per patient on a SOMATOM Flash scanner. Subtle liver lesion models (contrast = -15 HU) were inserted into the raw projection data from the patient scans. The projections were then reconstructed with FBP and SAFIRE (strength 5). Also, lesion-less images were reconstructed. Noise, contrast, CNR, and detectability index of an observer model (non-prewhitening matched filter) were assessed. It was found that SAFIRE reduced noise by 52%, reduced contrast by 12%, increased CNR by 87%. and increased detectability index by 65% compared to FBP. Further, a 2AFC human perception experiment was performed to assess the dose reduction potential of SAFIRE, which was found to be 22% compared to the standard of care dose. </p><p>In conclusion, this dissertation provides to the scientific community a series of new methodologies, phantoms, analysis techniques, and modeling tools that can be used to rigorously assess image quality from modern CT systems. Specifically, methods to properly evaluate iterative reconstruction have been developed and are expected to aid in the safe clinical implementation of dose reduction technologies.</p> / Dissertation
434

The cell surface organisation of the Notch-1 receptor

Weisshuhn, Philip Christian January 2014 (has links)
The Notch receptor family plays a key role in development and disease. In cancer, Notch can act either as an oncogene or as a tumour suppressor, and possibly as a cancer stem-cell factor. Whereas most research has focused on downstream signalling events, little is known about the cell surface organisation of Notch and its ligands. The extracellular part of Notch consists mainly of 36 epidermal growth factor-like domains (EGF-domains), many of which bind calcium. Studies have shown that tandem repeats of calcium-binding EGF domains form a rigid linear arrangement; however, the lack of calcium binding in EGF6, EGF10 and EGF22 led to the hypothesis that these might be sites of flexibility. This thesis addresses the effect of these domains on the organisation of the extracellular region of Notch and provides further insight into the calcium-binding properties of Notch. NMR residual dipolar coupling (RDC) measurements of these regions are presented, together with the X-ray crystallographic data obtained in collaboration. The crystal structure of the human Notch-1 construct EGF4-7 shows a tilt angle of 90° at the EGF5-6 interface which is much larger than the tilt angles of 10-20° observed for the EGF11-13 crystal structure. RDC measurements demonstrated an angle of ~70° in solution. The crystal structures of EGF21-23 and EGF20-23 showed a rod-shaped interface for the EGF21-22 domain, in which a cis-proline forms the packing interaction to a tyrosine at the β-turn in the major β-sheet of EGF22. These two interfaces are novel and demonstrate the possibility of interface formation without Ca<sup>2+</sup>. Crystallisation was unsuccessful for the EGF8-11 construct. However, RDC measurements indicate interdomain motion between EGF9 and EGF10 demonstrating a flexible interface. These data establish new information on the structural organisation and calcium-binding properties of the extracellular region of Notch and identify flexible and rigid interfaces within multiple tandem repeats of EGF domains. This information will be invaluable in constructing models of Notch-ligand complexes for testing in future functional experiments.
435

L- and M-Shell X-Ray Production Cross Sections of Neodymium Gadolinium, Holmium, Ytterbium, Gold and Lead by 25-MeV Carbon and 32-MeV Oxygen Ions

Andrews, Mike C., 1949- 08 1900 (has links)
L- and M-shell x-ray production cross sections have been measured for thin solid targets of neodymium, gadolinium, holmium, ytterbium, gold, and lead by 25 MeV 12/6C^q+ (q=4,5,6) and by 32 MeV 16/8O^q+ (q=5,7,8). The cross sections were determined from measurements made with thin targets (< 2.5 μg/cm2). For projectiles with one or two K-shell vacancies, the target x-ray production cross sections were found to be enhanced over those for projectiles without a K-shell vacancy. The sum of direct ionization to the continuum (DI) plus electron capture (EC) to the L, M, N... shells and EC to the K-shell of the projectile have been extracted from the data. The results are compared to the predictions of first Born theories, i.e., plane wave Born approximation for DI and Oppenheimer-Brinkman-Kramers formula of Nikolaev for EC and to the ECPSSR approach that accounts for Energy loss and Coulomb deflection of the projectile as well as for Relativistic and Perturbed Stationary States of inner shell electrons.
436

Exploring the nature of crystals in cheese through X-ray diffraction

Tansman, Gil Fils 01 January 2014 (has links)
The optimization of powder x-ray diffraction (PXRD) for the study of cheese crystals was the focus of this study. A survey was conducted of various manifestations of calcium lactate crystals on the rindless surface and within mechanical openings of Cheddar cheese using PXRD. The diffraction reference card database contained a card that was entitled calcium lactate pentahydrate and corresponded to some of the crystalline material found on the cheeses. Diffractions patterns generated from other samples of crystalline material revealed the existence of an unknown crystal that resembled and behaved similarly to calcium lactate pentahydrate, but did not match the reference card. The existence of two enantiomeric variants of calcium lactate pentahydrate had been firmly established; an experiment was thus designed to determine if the unknown diffraction pattern represented one enantiomeric form, and if the ambiguously named reference card represented the other. This experiment demonstrated that the existing reference card corresponded to calcium DL-lactate pentahydrate and that the unknown diffraction pattern was generated from calcium L-lactate pentahydrate. This study resulted in the proposal of a new reference card for calcium L-lactate pentahydrate and the proposed renaming of the existing card to calcium DL-lactate pentahydrate. This discovery allows the rapid identification of both forms of calcium lactate that form in and on cheese. In order to conduct the survey and experiment that are described above, the PXRD method needed to be adjusted for use with cheese crystals. Samples of cheese crystals pose a particular challenge because they are often composed of high proportions of moisture, fat, protein, and other amorphous material; these all disrupt the efficient diffraction of crystals and thus needed to be removed or minimized. The removal of water from samples is a particular challenge because some cheese crystals contain water of hydration that may be driven off in the process, thereby destroying the crystals. A protocol for the preparation of cheese samples for PXRD was consequently developed.
437

Development of focal geometry with non-ideal samples

Prokopiou, D. M. January 2015 (has links)
A novel geometry for powder X-ray diffraction (XRD), termed ‘focal construct geometry’ (FCG) is introduced and developed with both non-ideal samples and non-ideal sample conditions. FCG utilises an annular beam that has the unique feature of ‘focusing’ scattering maxima at single loci along a primary axis, hence offering diffraction data of enhanced intensity. This main advantage of FCG can be used within fields in need of rapid material identification, such as security screening in airports. A theoretical comparison between FCG and conventional transmission mode XRD showed that even though FCG suffers from broader diffraction peaks, an alternative approach to FCG data interpretation has the potential to provide narrower scattering maxima than conventional XRD. However, in order to employ this approach, discrimination between converging and diverging FCG scattering maxima is essential. Peak broadening was investigated by altering various aspects of FCG instrumentation components by either pencil beam XRD or FCG, indicating broad diffraction peaks independent of the beam geometry employed. Development of FCG resulted in the successful analysis of non-ideal samples, such as non-crystalline liquid samples, samples exhibiting preferred orientation and samples with large grain size, demonstrating advantages over conventional XRD. Furthermore, ideal samples (in terms of crystallinity, preferred orientation and grain size) were analysed by FCG under non-ideal conditions. This involved randomly orientating a single planar sample with respect to the primary axis, contrary to previous research that present FCG with a single planar sample normal to the primary axis. Sample rotation resulted in FCG scattering maxima with different xyz coordinates depending on the degree, axis and direction of rotation. Moreover, FCG analysis of multiple samples (normal to the primary axis) showed that as with all XRD arrangements, a priori knowledge of the samples’ position along the primary axis is required for effective data analysis. Investigation into the ability of FCG’s annular beam to act as a pre-sample coded aperture demonstrated an alternative method to interpret FCG images by recovering conventional XRD data. Additionally, two novel post-sample encoders (linear wire and Archimedean spiral) were considered. This enabled spatial discrimination of unknown samples along a primary axis and material identification for conventional XRD techniques. Combination of FCG with an absorbing edge post-sample encoder indicated discrimination between converging and diverging FCG scattering maxima. This ability can enable interpretation of single FCG images, as well as depth information of unknown samples within an inspection volume (e.g. airport luggage), hence enabling material identification.
438

Reaction of aqueous ammonium sulfide on SiGe 25%

Heslop, Stacy L., Peckler, Lauren, Muscat, Anthony J. 05 1900 (has links)
SiGe 25% substrates were treated with aqueous solutions of ammonium sulfide with and without added acid to understand the adsorption of sulfur on the surface. X-ray photoelectron spectroscopy showed no sulfide layer was deposited from aqueous (NH4)(2)S alone and instead both Si and Ge oxides formed during immersion in the sulfur solution. The addition of hydrofluoric and hydrochloric acids dropped the pH from 10 to 8 and deposited sulfides, yet increased the oxide coverage on the surface and preferentially formed Ge oxides. The sulfur coverage grew with increasing concentrations of acid in the aqueous (NH4)(2)S. The simultaneous deposition of O and S is suspected to be the result of oxidized sulfur species in solution. Metal-insulator-semiconductor capacitor (MISCAP) devices were fabricated to test the electrical consequences of aqueous ammonium sulfide wet chemistries on SiGe. MISCAPs treated with acidic ammonium sulfide solutions contained fewer interface defects in the valence band region. The defect density (D-it) was on the order of 10(+12) cm(-2) eV(-1). The flat band voltage shift was lower after the acidic ammonium sulfide treatment, despite the presence of surface oxides. Adsorption of S and potentially O improved the stability of the surface and made it less electrically active. (C) 2017 American Vacuum Society.
439

K-shell x-ray production cross sections in carbon, oxygen, fluorine, sodium, magnesium, and aluminum by 0.5 to 8.0 mev protons, helium, and lithium ions

Yu, Yueh-Chung 08 1900 (has links)
The goal of this work reported here is to test the limits of the ECPSSR theory in the transition region of the low Z1/Z2.
440

Investigations of protein structure : lysozyme in the crystalline and solution states

Cassels, Robert January 1979 (has links)
No description available.

Page generated in 0.0615 seconds