• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] EVALUATION OF OPTICAL RESPONSE RESULTING FROM THE INTERACTION BETWEEN GENTAMICIN AND SPHERICAL GOLD NANOPARTICLES GOLD NANORODS AIMING ANALYTICAL APPLICATION / [pt] AVALIAÇÃO DA RESPOSTA ÓPTICA DECORRENTE DA INTERAÇÃO ENTRE GENTAMICINA E NANOPARTÍCULAS DE OURO ESFÉRICAS E EM FORMA DE BASTÃO VISANDO APLICAÇÃO ANALÍTICA

JAROL RAMON MIRANDA ANDRADES 12 April 2017 (has links)
[pt] A gentamicina é um antibiótico aminoglicosídio (AMG) amplamente utilizado na medicina humana e veterinária por exibir um amplo espectro de ação no tratamento de infecções causadas por bactérias gram-positivas e gram-negativas. No entanto, sua prescrição deve ser criteriosa devido aos possíveis efeitos colaterais como ototoxidade e nefrotoxidade. Os métodos espectroanalíticos usados na determinação de gentamicina quase sempre requerem a modificação da molécula com agentes de derivatização química já que os AMG não possuem grupos cromóforos relevantes. Esse tipo de procedimento é trabalhoso e na maioria dos casos implica em resultados com a exatidão questionável em função de dificuldades relacionadas, por exemplo, na reprodução do rendimento das reações de derivatização. Na presente dissertação, a influência da gentamicina (na forma de sulfato) no efeito da ressonância plasmônica nas superfícies das nanopartículas de ouro (AuNPs) foi estudada e utilizada para o desenvolvimento de métodos analíticos para a determinação desse AMG. Nanopartículas de ouro esféricas (AuNPs-E), tanto em meio aquoso quanto em meio organizado por surfactantes, e nanopartículas de ouro na forma de bastão (AuNPs-B), em meio aquoso contendo resíduo do surfactante catiônico usado na sua síntese, foram estudados como sondas analíticas para a gentamicina. As AuNPs-E foram sintetizadas em condições próximas às descritas por Turkevich, enquanto as AuNPs-B foram obtidas na presença do surfactante catiônico CTAB, como indicado pelo procedimento de Nikoobakht e El-Sayed. Um estudo criterioso de ajuste de condições para a estabilidade da sonda e reprodutibilidade da resposta óptica da sonda na presença de gentamicina foi realizado. Dentre os fatores estudados incluem-se o valor do pH da sonda de trabalho, o tempo de 7 estabilização, o tipo e a concentração de surfactante. As condições finais para a determinação de gentamicina usando AuNPs-E foram: concentração de nanopartículas nas dispersões de trabalho de 4,1 × 10 elevado a -10 mol L elevado a -1, pH 3,7 (pH original da dispersão AuNPs-E), concentração do surfactante Tween-20 de 1,0 × 10 elevado a -8 mol L elevado a -1. Para a sonda de AuNPs-B, as condições escolhidas foram: concentração de nanopartículas nas dispersões de trabalho de 3,8 × 10 elevado a -10 mol L elevado a -1, pH 5,2 (pH original da dispersão AuNPs-B). Os sinais produzidos por essas sondas foram estáveis por pelo menos 2 h. As curvas analíticas foram construídas a partir do monitoramento da luz transmitida através da dispersão aquosa em 526 nm (decréscimo da banda de ressonância transversal) ou 681 nm (incremento de banda decorrente da aglomeração das AuNPs) para AuNPs-E, e em 662 nm (decréscimo da banda de ressonância longitunidal) no caso das AuNPs-B. Para ambas as sondas, independentemente do comprimento de onda monitorado, a faixa linear da resposta analítica cobriu duas ordens de magnitude de concentração (entre 10 elevado a -9 à 10 elevado a -7 mol L elevado a -1). Os limites de detecção para a gentamicina foram de 1,7 × 10 elevado a -9 mol L elevado a -1 no método baseado no uso da sonda de AuNPs-E e de 5,3 × 10 elevado a -9 mol L elevado a -1 para o método em que se utilizou a sonda de AuNPs-B. Os métodos foram aplicados para análise de duas formulações (soluções injetáveis) de sulfato de gentamicina disponíveis no mercado para o tratamento de gado leiteiro. Os métodos mostraram-se seletivos em relação aos excipientes presentes nas soluções injetáveis (considerando as quantidades relativas destes nas formulações) e os resultados analíticos indicaram recuperações percentuais de gentamicina entre 96 e 98 por cento (em relação ao valor descrito nas bulas dos medicamentos) sendo estatisticamente iguais às recuperações percentuais obtidas utilizando calorimetria com derivatização química com ninidrina, usado como método de referência. / [en] Gentamicin is an aminoglycoside (AMG) antibiotic widely used in human and veterinary medicine as they present a broad spectrum of action covering gram-positive and gram-negative bacteria. However, medical prescription of AMG must be made with care due to possible side effects such as nephrotoxicity and ototoxicity. Spectroanalytical methods used for the determination of gentamicin almost always require the modification of the analyte molecule by chemical derivatization agents since AMG does not have any relevant chromophore groups. Chemical derivatization is cumbersome and in most cases results in poor accuracy due to, for instance, difficulties to reproduce reaction yields. In the present work, the influence of gentamicin (as sulphate) on the plasmon resonance on the surface of gold nanoparticles (AuNPs) was studied and used to develop analytical methods for the determination of this AMG. Spherical gold nanoparticles (AuNPs-E), both in aqueous medium and in médium containing surfactants, as well as gold nanorods (AuNPs-B) in an aqueous medium containing residues of the cationic surfactant used in the synthesis, as analytical probes for gentamicin. The AuNPs-E were synthesized in conditions similar to those described by Turkevich while AuNPs-B were obtained in the presence of the cationic surfactant CTAB as described by El-Sayed and Nikoobakht. A careful study was carried out to establish the conditions for a stable and reproducible optical response of the analytical probe in the presence of gentamicin. Among these conditions includes the pH values of the working probe, stabilization time of the probe, the type and concentration of surfactant in 9 the system. The final conditions for the determination of gentamicin using AuNPs-E were 4.1 × 10 raised to -10 mol L raised to -1 of nanoparticle in the working dispersion, pH 3.7 (the original pH of the AuNPs-E aqueous dispersion), 1.0 × 10 raised to -8 mol L raised to -1 of the surfactant Tween-20. For the AuNPs-B probe, the chosen conditions were: 3.8 × 10 raised to -10 mol L raised to -1 of nanoparticles in the working dispersions, pH 5.2 (pH of the stock dispersion AuNPs B). The signals generated by these probes were stable for at least 2 h.The analytical curves were constructed by monitoring the light transmitted through the aqueous dispersion at 526 nm (decreasing of the transversal resonance band) or at 681 nm (increment of a band resulting from the agglomeration of AuNPs) to AuNPs-E, and 516 nm (decreasing of the transversal resonance band) or at 662 nm (decreasing of the longitunidal resonance band) in the case of AuNPs-B. For both of the probes, regardless of the monitored wavelength, the linear analytical response range covered two orders of magnitude (from 10 raised to -9 to 10 raised to -7 mol L raised to -1). The detection limits for gentamicin were 1.7 × 10 raised to -9 mol L raised to -1 in the method based on the use of AuNPs-E probe, and 5.3 × 10 raised to -9 mol L raised to -1 for the method based on the use of the AuNPs-B probe. The methods were applied for the analysis of two gentamicin sulfate based formulations (injectable solutions) commercially available for the treatment of dairy cattle. The methods were selective in relation to the excipients present in these injectable solutions (considering the relative amounts of these in the formulations) and analytical results indicated percent recoveries of gentamicin between 96 and 98 per cent (relative to the values indicated in the medicine instructions) which was statistically equal to the percent recoveries obtained using the reference colorimetric method based on the chemical derivatization using ninhydrin.
2

[pt] ESTUDO DO COMPORTAMENTO DE NANOPARTÍCULAS DE OURO SINTETIZADAS DIRETAMENTE EM ÁGUA E NA PRESENÇA DE DIFERENTES SURFACTANTES E SUA AVALIAÇÃO QUANTITATIVA COMO SONDA ANALÍTICA PARA AMINOGLICOSÍDEOS / [en] STUDY OF THE PERFORMANCE OF GOLD NANOPARTICLES SYNTHESIZED DIRECTLY IN WATER AND IN THE PRESENCE OF DIFFERENT SURFACTANTS AND ITS QUANTITATIVE EVALUATION AS AMINOGLYCOSIDES ANALYTICAL PROBE

LARISSA INGRID MADEIRA SILVA 08 April 2021 (has links)
[pt] Nanopartículas de ouro dispersas em água (AuNPs-H) e nanopartículas de ouro na presença dos surfactantes brometo de cetiltrimetilamônio (AuNPs-CTAB) e brometo de didecildimetilamônio (AuNPs-C10DAB) foram sintetizadas e caracterizadas por diversas técnicas. As variações nos perfis espectrais no UV-Vis dessas nanopartículas foram estudadas levando-se em consideração a intensidade e o comprimento de onda máximo da banda de ressonância plasmônica de superfície localizada (LSPR); foram acompanhadas em função do tempo para nanopartículas estocadas sob refrigeração (4 graus celsius) com as mantidas na temperatura ambiente (27 graus celsius). Um comportamento anômalo (mais instável) foi observado para AuNPs-C10DAB na concentração 1,0 ×10-4 mol L-1. As suas atividades catalíticas também foram avaliadas na presença de 4-nitrofenol e verificou-se que a cinética mais efetiva foi do sistema sem surfactante. Finalmente, um estudo de interação com aminoglicosídeos (AMG) foi feito visando o uso das nanopartículas como sonda analítica. Todavia, somente AuNPs-H apresentaram resultados satisfatórios, o que indica que o surfactante impede que o AMG se aproxime da superfície das nanopartículas, visto que, em concentrações mais elevadas de CTAB ou C10DAB, não há variação significativa no sinal original da sonda quando o AMG está presente. Um método analítico foi desenvolvido baseado na interação AuNPs-H-gentamicina e AuNPs-H-neomicina a partir da otimização dos parâmetros: concentração de AuNPs-H, tampão, tempo de medição e faixa de concentração de AMG. Na condição ajustada para sondagem quantitativa, cada dispersão de trabalho foi constituída por 40 porcento v/v (1,2 × 10-9 mol L-1) de AuNPs-H 1,0 mL de tampão citrato pH 4,0 (1,0 × 10-2 mol L-1) e volume final de 5,0 mL ajustado pela adição água ultrapura, após micro-volumes apropriados de soluçãoestoque de AMG (exceto na dispersão branco) ou de amostras adicionadas. O monitoramento da variação dos perfis espectrais foi feito em 511 e em 681 nm, habilitando a construção de curvas analíticas em 681, e na razão (681/511). Para gentamicina, a faixa linear variou de 0,6 a 600 microgramas L-1 com o limite de detecção (LD) de 0,06 microgramas L-1. Para neomicina, faixa linear foi de 7,3 a 550 microgramas L-1, tendo LD de 6,2 microgramas L-1. A aplicação do método foi feita determinando-se gentamicina (fortificação) em leite integral, e neomicina em solução controle (amostra aquosa simulada), medicamento e em saliva. Para habilitar a seletividade do método foi necessária a utilização de extração em fase sólida (SPE) em cartuchos comercias empacotados com polímero de impressão molecular de AMG. Em amostras de leite (40 microlitros), após limpeza e SPE, foi possível quantificar 1,72 mais ou menos 0,03 microgramas de gentamicina, o equivale a 39,1 mais ou menos 0,2 porcento. As recuperações para neomicina em amostras de medicamento foram de aproximadamente 45 mais ou menos 3,0 porcento (após SPE), indicando interferências de outros componentes. Neomicina também foi recuperada em amostras de saliva após uso do medicamento obtendo valores próximos a 0,36 mais ou menos 0,02 microgramas. Em contraste, as recuperações em amostras simuladas chegaram até 102,6 mais-menos 1,3 porcento (sem necessidade de SPE). Por fim foi feita uma avaliação comparativa de interação de AuNPs-H e nanopartículas de ouro sintetizadas com redução com citrato (AuNPs-citrato) que indicou diferença de comportamento na interação com AMG. / [en] Water-dispersed gold nanoparticles (AuNPs-H) and gold nanoparticles in the presence of surfactants cetyltrimethylammonium bromide (AuNPs-CTAB) and didecyldimethylammonium bromide (AuNPs-C10DAB) were synthesized and characterized using several techniques. The differences in the UV-Vis spectral profiles of these nanoparticles were studied monitoring the intensity and the localized surface plasmon resonance band (LSPR) maximum wavelength; these were monitored as a function of time taking into account storage conditions: under refrigeration (4 Celsius degrees) and at room-temperature (27 Celsius degrees). Anomalous (more unstable) profile was observed for AuNPs-C10DAB at 1.0 × 10-4 mol L-1. Their catalytic activities were also evaluated in the presence of 4-nitrophenol and it was shown that the most effective kinetics was observed for the system without surfactant. Finally, an interaction study with aminoglycosides (AMG) was conducted aiming the application of nanoparticles as analytical probe. Only AuNPs-H produced adequate results, indicating that the surfactant prevents interaction between AMG and the surface of the nanoparticles since at higher concentrations of CTAB or C10DAB there is no significant variation in the original probe signal in presence of AMG. An analytical method was developed based on the AuNPs-H-gentamicin and AuNPs-H-neomycin interaction taking into consideration the optimization of the parameters: AuNPs-H concentration, buffer, signal stabilization time and the AMG concentration range. In the adjusted condition for quantitative probing, each dispersion consisted of 40 percent v/v (1.2 × 10-9 mol L-1) of AuNPs-H, 1.0 mL of citrate buffer pH 4.0 (1.0 × 10-2 mol L-1) and final volume of 5.0 mL adjusted with ultrapure water addition, after appropriate micro-volumes of a stock solution of AMG (except in blank dispersion) or sample added. The spectral profiles were monitored at 511 and 681 nm, allowing theconstruction of analytical curves at 681, and at the ratio (681/511). For gentamicin, the linear range reached from 0.6 to 600 microgram L-1 with the limit of detection (LD) of 0.06 microgram L-1 . For neomycin, the linear range was 7.3 to 550 microgram L-1, with LD of 6.2 microgram L-1. The application of the method was made by determining gentamicin(fortification) in whole milk, and neomycin in control solution (simulated aqueous sample), pharmaceutical samples and saliva. In order to enable selectivity of the method it was necessary to use solid phase extraction (SPE) using a commercial SPE cartridge packed with an AMG molecular imprinted polymer. In milk samples (40 microlitre), after clean up and SPE, it was possible to quantify 1,72 plus-minus 0,03 microgram gentamicin, which is equivalent to 39,1 plus-minus 0,2 percent). Recoveries for neomycin in drug samples were approximately 45 plus-minus 3.0 percent (after SPE), indicating interferences of other components. Neomycin was also recovered in saliva samples after drug use obtaining values close to 0.36 plus-minus 0.02 microgram. In contrast, the recoveries in simulated samples reached up to 102.6 plus-minus 1.3 percent (no need for SPE). Finally, a comparative evaluation of the interaction of AuNPs-H and gold nanoparticles synthesized with reduction with citrate (AuNPs-citrato) was performed, indicating differences in terms of the interaction with AMG.
3

[en] DEVELOPMENT OF ELECTRO-ANALYTICAL METHODS USING ELECTROCHEMICAL CARBON-BASED SENSORS FOR DETERMINATION OF TRIFLOXYSTROBIN, GENTAMICIN AND LAPACHOL / [pt] DESENVOLVIMENTO DE MÉTODOS ELETROANALÍTICOS UTILIZANDO SENSORES ELETROQUÍMICOS BASEADOS NO CARBONO PARA DETERMINAÇÃO DE TRIFLOXISTROBINA, GENTAMICINA E LAPACHOL

JOSEANY DE MORAES SANTOS ALMEIDA 20 December 2018 (has links)
[pt] O presente trabalho teve como objetivo o desenvolvimento de métodos eletroanalíticos empregando elétrodos de grafite-epóxi e diamante dopado com boro para a determinação do antibiótico sulfato de gentamicina, substâncias de interesse biológico (naftoquinonas) e do pesticida trifloxistrobina. O diamante dopado com boro (DDB) apresenta características atraentes de detecção eletroquímica que são úteis em aplicações analíticas baseadas em voltametria e amperometria. Possui uma ampla janela de potencial em soluções aquosas que permitiu a quantificação do fungicida trifloxistrobina (em +1744 mV versus Ag/AgCl(KClsat)) por voltametria de onda quadrada (SWV), em um tampão Britton-Robinson (0,04 mol L-1, pH 4,00 )/acetonitrila 70/30 por cento v/v. A curva de adição de analito foi obtida usando amplitude de pulso 40 mV, freqüência de 30 Hz, passo de potencial de 20 mV. O limite instrumental de detecção foi de 1,4 × 10-7 mol L-1 e a faixa linear dinâmica abrangeram três ordens de grandeza (10-7 a 10-5 mol L-1). As amostras foram analisadas com recuperações de cerca de 80 por cento em amostras de suco de laranja e de 92,4 a 104,0 por cento em amostras de água. Um estudo para avaliar potenciais interferentes foi realizado na presença de outros fungicidas. Estudos diagnósticos indicaram que a oxidação da trifloxistrobina em meio aquoso na superfície do DDB é irreversível, envolvendo duas etapas, cada um com dois elétrons. A degradação UV da trifloxistrobina foi avaliada utilizando o método eletroquímico proposto e a cinética de degradação estabelecida com meia-vida de 1.07 min. A amperometria por injeção em batelada (BIA do inglês batch-injection analysis) com o DDB (operando a +2000 mV) foi utilizada para desenvolver um método para a determinação de sulfato de gentamicina. A extração em fase sólida (SPE do inglês solid-phase extraction), utilizando um cartucho empacotado com um polímero impresso molecularmente, tendo a canamicina como molécula molde, foi utilizada para melhorar a seletividade. O tampão acetato (0,01 mol L-1; pH 4,4) foi utilizado como eletrólito suporte. A oxidação do sulfato de gentamicina ocorreu logo após a injeção do analito (60 microlitros) que entra em contato com a superfície do eletrodo. O cartucho de SPE foi muito eficiente na retenção do analito quando comparado com o polímero não-impresso correspondente (NIP). A curva analítica apresentou resposta linear, a precisão instrumental foi inferior a 3 por cento e o limite de quantificação foi de 2,7 × 10-6 mol L-1. A frequência analítica foi de 90 medições h-1 e nenhum efeito de memória foram observados entre as medidas sequênciais. O desempenho do método proposto foi comparado com o obtido por HPLC-UV e com espectrofotometria de absorção molecular (ambos após derivação química do analito com o-ftalaldeído ou com ninhidrina). O método desenvolvido neste trabalho foi aplicado em formulações farmacêuticas injetáveis e em amostras simuladas, com recuperações próximas de 100 por cento. Para a determinação do lapachol foi utilizada a SWV usando um eletrodo de grafite-epoxi feito no laboratório. O meio eletrolítico utilizado foi uma solução aquosa contendo o surfactante catiônico CTAB (1,2 × 10-4 mol L-1), tampão fosfato (4,0 × 10-2 mol L-1, pH 6,0) e KNO3 (1,0 mol L-1). O surfactante catiônico melhorou a difusão e a interação do analito com o eletrodo, produzindo um processo reversível que melhorou a corrente total medida pelo sistema. O sinal do lapachol foi medido a -470 mV, após pré-concentração a 400 mV durante 140 s, usando frequência de 30 Hz, amplitude de pulso de 40 mV com passo de potencial de 20 mV. O limite instrumental de detecção foi de 0,029 mg L-1 e a faixa linear dinâmica abrangeu duas ordens de grandeza. Na presença de beta-lapachona (isômero estrutural), a seletividade foi obtida pela derivada de primeira ordem do sinal SWV. A determinação do lapachol em extrato etanólico de Tabebuia impetiginosa foi realizada após uma s / [en] The present work aimed to develop electroanalytical methods using graphite-epoxy and boron-doped diamond electrodes for the determination of the antibiotic gentamicin sulfate, substances of biological interest (naphthoquinones) and the pesticide trifloxystrobin. Boron doped diamond (BDD) features attractive electrochemical detection characteristics that are useful in analytical applications based on voltammetry and amperometry. It has a wide potential window in aqueous solutions that allowed the quantification of the fungicide trifloxystrobin (in +1744 mV versus Ag/AgCl(KClsat)) by square-wave voltammetry (SWV) in Britton-Robinson buffer (0.04 mol L-1, pH 4.00) / acetonitrile 70/30 percent v/v electrolyte medium. The analyte addition curve was constructed using 40 mV pulse amplitude, 30 Hz frequency, 20 mV step potential. The instrumental limit of detection was 1.4 × 10-7 mol L-1 and the linear dynamic range covered three orders of magnitude (from 10-7 to 10-5 mol L-1). Recoveries of about 80 percent in orange juice samples and 92.4 to 104.0 percent in water samples. A study to evaluate potential interferences was carried out in the presence of other fungicides. Diagnostic studies indicated that the oxidation of trifloxystrobin in aqueous medium, on the surface of the BDD, is irreversible, involving two steps, each of them with two electrons. UV degradation of trifloxystrobin was studied using the proposed voltammetric method and degradation kinetics with a half-life of 1.07 min was established. Batch injection amperometry (BIA) with BDD (operating at +2000 mV) was used to develop a method for the determination of gentamicin sulfate. Solid phase extraction (SPE) using a cartridge packed with a molecular imprinting polymer made with kanamycin as the template molecule, was used to improve the selectivity. The acetate buffer (0.01 mol L-1; pH 4.40) was used as supporting electrolyte. Oxidation of gentamicin sulfate occurred right after the analyte (60 microlitres solution) comes into contact with the surface of the electrode. The SPE cartridge packed with MIP was very efficient in retaining the analyte when compared to the one packed with the corresponding non-printed polymer (NIP). The analytical curve was linear, the instrument accuracy was less than 3 percent and the limit of quantification was 2.7 × 10-6 mol L-1. The analytical frequency was 90 measurements h-1 and no memory effect was observed between sequential measurements. The performance of the proposed method was compared with that obtained by HPLC-UV and molecular absorption spectrophotometry (both after chemical derivatization of the analyte with o-phthalaldehyde or with ninhydrin). The method was applied in injectable pharmaceutical formulations and in simulated samples, with recoveries close to 100 percent. For the determination of lapachol SWV was employed using a graphite-epoxy electrode made in the laboratory. The electrolytic medium used was an aqueous solution containing the cationic surfactant CTAB (1.2 × 10-4 mol L-1), phosphate buffer (4.0 × 10 -2 mol L-1, pH 6.00) and KNO3 (1.0 mol L-1). The cationic surfactant improved the diffusion and interaction of the analyte with the electrode, producing a reversible process that improved the total current measured by the system. The lapachol signal was measured at -470 mV after preconcentration at 400 mV for 140 s, using a 30 Hz frequency, 40 mV pulse amplitude with a step potential of 20 mV. The instrumental limit of detection was 0.029 mg L-1 and the dynamic linear range comprised two orders of magnitude. In the presence of beta-lapachone (structural isomer), the selectivity was obtained by the first-order derivative of the SWV signal. The determination of lapachol in ethanolic extract of Tabebuia impetiginosa was carried out after a simple separation of the analyte by thin layer chromatography. The results are statistically similar (with 95 percent confidence level) with those performed through HPLC-UV. Studies for the simultaneous determination of beta-lapachone and alpha-lapachone were also successful

Page generated in 0.0566 seconds