• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] DETERMINATION OF PLATINUM DERIVED FROM ANTI-CANCER DRUGS IN URINE SAMPLES BY ATOMIC ABSORPTION SPECTROMETRY / [pt] DETERMINAÇÃO DE PLATINA PROVENIENTE DE SUBSTÂNCIAS ANTINEOPLÁSICAS EM URINA POR GF AAS E HR-CS F AAS

ANILTON COELHO COSTA JUNIOR 11 December 2007 (has links)
[pt] Devido à sua capacidade de inibição do processo de divisão celular, complexos de platina têm sido empregados na quimioterapia do câncer desde o final da década de 60, sendo a cisplatina e a carboplatina as formas mais utilizadas. Estudos farmacocinéticos e a estimativa da quantidade de platina acumulada no organismo durante o tratamento quimioterápico ou devido à exposição ao metal têm sido alvo de grande interesse. Logo, são necessários métodos analíticos adequados para o monitoramento de platina em amostras clínicas, apropriados para essas diferentes substâncias. No presente trabalho, foram desenvolvidos procedimentos analíticos rápidos, simples e exatos para determinação direta de platina, na forma de cisplatina e carboplatina, em urina humana, utilizando a espectrometria atômica. No caso da absorção atômica em forno de grafite, o programa de temperatura, o volume de amostra e a concentração do diluente (HNO3) foram definidos por um planejamento composto central. Nas condições otimizadas, os resultados obtidos pelo procedimento proposto não apresentaram diferenças estatisticamente significativas daqueles obtidos por procedimentos comparativos independentes, na análise de amostras de urina de paciente submetido ao tratamento com cisplatina. A calibração foi realizada por adição de analito, com PtCl2. Com a adição de NaCl ao meio diluente, os efeitos multiplicativos de matriz puderam ser contornados, permitindo a calibração externa com soluções de calibração preparadas no mesmo meio que o branco, utilizando sais inorgânicos de platina. Melhor sensibilidade também foi obtida, e recuperações de 98±4% foram observadas para os vários níveis de concentração estudados, assim como coeficientes de variação de 1 a 10%, tanto para a cis como para a carboplatina. O limite de detecção (n=10, k=3) foi de 4 (mi)g L-1 de Pt na amostra original. A espectrometria de absorção atômica com fonte contínua de alta resolução na chama (HR-CS F AAS) também foi estudada. As condições da chama foram definidas por um planejamento multivariado D-optimal, tomando-se como resposta a soma dos coeficientes angulares das curvas de adição de analito em três urinas diferentes, assim como o desvio padrão relativo dessas inclinações. O limite de detecção foi de 55 Og L-1 (n=10, k=3), na amostra original, em Pt, cerca de uma ordem de grandeza melhor do que aquele obtido utilizando-se um equipamento de fonte de linhas. Calibração externa, com soluções de calibração em urina livre de Pt, utilizando sal inorgânico de platina (PtCl2), foi possível, e os resultados obtidos por HR-CS F AAS não se mostraram significativamente diferentes daqueles encontrados por procedimentos comparativos independentes. / [en] Platinum coordination compounds have been used in cancer chemotherapy since the late 1960s. Cisplatin and carboplatin are the most common platinum based drugs used in cancer treatment. Pharmacokinetics investigations, the determination of the body burden during the treatment as well as the baseline levels of platinum in humans has attracted great interest. Thus, accurate analytical methods for fast and easy platinum monitoring in clinical samples are necessary. In the present work, atomic spectrometric methods for the direct determination of platinum as cisplatin and carboplatin in human urine were investigated. In relation to Graphite Furnace Atomic Absorption Spectrometry the optimum temperature program, sample volume and diluent concentration were defined by a central composite design optimization. Analyte addition with PtCl2 was used for calibration, and no statistically significant difference was observed between the results obtained by the proposed and comparative procedures in the analysis of a set of urine samples. Multiplicative matrix effects were overcome by adding NaCl to the diluent solution. External calibration with PtCl2 in blank matched medium was then possible. The recoveries were 100±1%, and the coefficient of variation ranged from 1 to 10%. The limit of detection (LOD) was 4 ug L-1 of Pt in the original urine sample. High resolution continuous source flame atomic absorption spectrometry was also investigated. The flame conditions were optimized by a multivariate D-optimal design, taking as response the sum of the analyte addition calibration slopes and their standard deviation. The LOD was 55 Og L-1 (n=10, k=3), in the original sample. Matrix matched external calibration with PtCl2, was possible, and the results obtained by the proposed procedure were also in good agreement with those obtained by independent comparative procedures.
2

[pt] HIDROTRATAMENTO DE ÓLEO DE COCO COM CATALISADORES DE NI E PT SUPORTADOS EM SILICA-ALUMINA E SBA-15 PARA A OBTENÇÃO DE ÓLEO DIESEL / [en] HYDROTREATMENT OF COCONUT OIL USING NI AND PT CATALYSTS SUPPORTED ON SILICA-ALUMINA AND SBA-15 TO OBTAIN DIESEL OIL

NUBIA MARIA MORA ALVAREZ 30 April 2020 (has links)
[pt] Os catalisadores de platina, níquel e platina suportados em sílica-alumina e sílica mesoporosa (SBA-15) foram investigados para o hidrotratamento do óleo de coco para produção de bio-óleo. Os suportes foram carregados com 1 por cento de Pt e 5 por cento de Ni e os catalisadores resultantes foram caracterizados para determinar suas propriedades estruturais e de textura. Os catalisadores foram reduzidos e testados em um reator semi-descontínuo a 360 C sob 10 MPa de hidrogênio durante 4 horas. Foram obtidos 30-40 por cento de remoção de oxigênio. As curvas de destilação dos produtos e seu ponto de inflamação e gravidade específica (a 20 C) foram determinados pelos métodos oficiais ASTM e ABNT/NBR a serem comparados com o diesel derivado do petróleo. As curvas de destilação e as propriedades físico-químicas foram muito próximas das especificações estabelecidas pela legislação brasileira para o diesel comercial. Destilou-se 90 por cento do volume de cada produto na faixa de temperatura de 180-370 C, o ponto de inflamação ficou entre 76-81 e o número do índice de cetano foi calculado como 47-48, de acordo com as especificações do diesel comercial. Os produtos obtidos com os catalisadores Pt/SiO2Al2O3 e PtNi/SBA-15 também apresentaram gravidade específica dentro da faixa de especificação (865 e 860,0 kg/m3, respectivamente). Os catalisadores utilizados mostraram sua potencial aplicação para a produção de biocombustíveis na faixa de diesel de petróleo pelo processo de hidrotratamento de óleo de coco. / [en] Platinum, platinum nickel and nickel catalysts supported on silicaalumina and mesoporous silica (SBA-15) were investigated for hydrotreating of coconut oil to produce bio oil. The supports were loaded with 1 percent Pt and 5 percent Ni content and the resulted catalysts were caracterized to determine their strutural and textural properties. The catalysts were reduced and tested in a semi-batch reactor at 360 C under 10 MPa of hydrogen during 4 hours. It was obtainned 30-40 percent of oxygen removal. The distillation curves of products and their flash point and specific gravity (at 20 C) were determined by oficials ASTM, and ABNT/NBR methods to be compared with the petroleum-derived diesel. The distillation curves and physicochemical properties were very close to specifications stabilished by Brazilian legislation for comercial diesel. 90 percent of the volume of each product was distilled in the temperature range of 180-370 C, the flash point was between 76-81 and the cetane index number was calculated as 47-48 in agreement with the specifications for comercial diesel. The products obtainned using the Pt/SiO2Al2O3 and PtNi/SBA-15 catalysts also presented specific gravity within the specification range (865 e 860.0 kg/m3 respectively). The catalysts used showed their potential application for the production of biofuels in the petroleum diesel range by coconut oil hydrotreatment process.

Page generated in 0.0347 seconds