91 |
Avaliação da concentração de nitrogenio e fosforo no liquido infiltrado no solo, apos aplicação de lodo liquido de esgoto domesticoNascimento, Patricia Mazzante do 11 May 2002 (has links)
Orientador : Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T10:06:11Z (GMT). No. of bitstreams: 1
Nascimento_PatriciaMazzantedo_M.pdf: 8382154 bytes, checksum: c1ba989f8a1c57443cba37e8a18de7be (MD5)
Previous issue date: 2002 / Resumo: O Iodo de esgoto é um resíduo gerado no tratamento da fase líquida dos esgotos sanitários e que precisa ser disposto de maneira adequada para não causar riscos de contaminação ao ambiente. O excesso de nutrientes como, nitrogênio e fósforo presentes no Iodo de esgoto, podem provocar o comprometimento do solo e da água subterrânea, após sua aplicação no solo. Neste estudo experimental, foram feitas aplicações de Iodo líquido digerido em reatores com 0,88 m3 de volume (1,00 m x 0,88 m2), preenchidos com solo do tipo franco-argiloso. As aplicações realizaram-se a cada 40 dias (com base na respirometria), durante um ano, totalizando 9 aplicações de Iodo ao final do período. Foram utilizadas as taxas 2,5; 5 e 7,5 t/ha a cada 40 dias (calculado na base seca), o líquido infiltrado no solo, foi coletado ao longo do perfil do solo nas profundidades: 0,25; 0,50; 0,75 m e 1,0 m (descarte de fundo). O líquido infiltrado foi avaliado quanto aos parâmetros nitrogênio (amônia, nitrito e nitrato) e fósforo total. Após o término da pesquisa, os resultados obtidos, mostraram que a taxa 2,5 t/ha aplicada a cada 40 dias, durante um ano, foi a que melhor resultado apresentou no que diz respeito a proteção das águas subterrâneas contra contaminação com nitrato e fósforo. As concentrações de nitrato no líquido coletado a 1,0 m, ficou em torno de 6,0 mg de N/L e não ultrapassou os 10 mg N/L estabelecido pela legislação, o fósforo total ficou em torno de 0,003 mg de P/L. Estas concentrações foram obtidas mesmo após intensa precipitação pluviométrica / Abstract: The sewage sludge is a residue produced from the wastewater treatment and it needs to be disposed in a correct way so that it can't cause environment contamination. The excess of nutrients as, nitrogen and phosphorus, present in sewage sludge can cause the soil and groundwater contamination after its application in soil. In this experimental study sewage sludge were made in reactor with 0,88 m3 (1,00 m x 0,88 m2) filled with soil. The sewage sludge was applied every 40 days (related to the respirometer test) , during one year, in total 9 sewage sludge application. The rates 2,5; 5,0 and 7,5 t/ha were used (calculated in dry weight) and the infiltrated liquid in soil was coleted in the 0,25 ; 0,50 ; 0,75 and 1,00 m depht. The investigated parameters in the infiltrated liquid were (ammonia, nitrite, nitrate and phosphorus ). The research shows that the 2,5 t/ha rate were the best result related to the groundwater contamination. The nitrogen (nitrate) and phosphorus forms concentration were under the limits set by the Brazilian legislation, even after intense precipitation / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
92 |
A utilização da tecnica MIMS na determinação de trialometanos em aguas de abastecimento e a influencia do ion brometo, da amonia e de algas na formação desses compostosBorges, João Tito 03 August 2018 (has links)
Orientador: Jose Roberto Guimarães / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T17:23:47Z (GMT). No. of bitstreams: 1
Borges_JoaoTito_D.pdf: 1076342 bytes, checksum: 46072743fa4cd122696aa0cfa149d6f1 (MD5)
Previous issue date: 2003 / Doutorado
|
93 |
Avaliação do consumo de água das empresas do Complexo Industrial Portuário de Suape no contexto de desenvolvimento sustentávelFrancisco da Silva, Jonas 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T18:29:30Z (GMT). No. of bitstreams: 2
arquivo351_1.pdf: 2342975 bytes, checksum: dc428c8cb3b575ad2daab984ab1239f2 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / Companhia Pernambucana de Saneamento / A água é essencial para a sobrevivência humana, além de ser parte importante para
o desenvolvimento econômico. Seu uso racional tem sido motivo de muitas
conferências mundiais, mas também locais, no enfoque do desenvolvimento
sustentável. Para entender a crise do meio ambiente e as propostas que visam
superá-la, é imprescindível situá-las no tecido das relações que envolve o Estado, a
sociedade e o indivíduo. A sociedade é composta de indivíduos, grupos e classes
sociais, geralmente com interesses distintos. Para mitigar esse antagonismo as
políticas públicas, as leis que expressam esses conflitos, bem como as instituições
precisam intervir. A política hídrica, como importante instrumento legal da
intervenção do Estado, interpõe-se diretamente nas relações de poder, na
apropriação e no uso de um recurso cada vez mais escasso, a água. Este trabalho
apresenta os resultados da avaliação do consumo de água bruta e tratada das
empresas do Complexo Industrial Portuário de Suape no contexto do
desenvolvimento sustentável, no período de 2007 a 2009. Assinala aspectos
relacionados ao crescimento populacional da circunvizinhança, provocado não
somente pela atratividade turística, mas principalmente pelo crescimento econômico
local. Fundamentado no quadro teórico, na documentação, nas entrevistas, na
coleta e análises dos dados, o estudo revela resultados importantes e sublinha
aspectos inerentes ao uso inteligente dos recursos hídricos disponíveis. Procura
mostrar o papel do Estado na condução de políticas públicas, notadamente as que
dizem respeito ao Saneamento. Discute sucintamente o histórico do Saneamento no
Brasil a partir de décadas recentes, mais precisamente 1988, com a promulgação da
Constituição Federal. Aborda questões concernentes ao novo marco regulatório do
setor com a adoção da Lei Federal nº 11.445/2007. Como resultados, o trabalho
propõe a implementação de políticas públicas para economia e reuso da água,
controle das perdas físicas e um rigoroso controle quanto à exploração de águas
subterrâneas
|
94 |
Avaliação da atividade mutagenica de extratos organicos de corpos d'agua do estado de São Paulo atraves do teste de AmesUmbuzeiro, Gisela de Aragão, 1957- 22 October 1990 (has links)
Orientador : Renato Bonatelli Jr / Tese (doutorado) - Universidade Estadualde Campinas, Instituto de Biologia / Made available in DSpace on 2018-07-13T22:55:43Z (GMT). No. of bitstreams: 1
Umbuzeiro_GiseladeAragao_D.pdf: 5667155 bytes, checksum: 6033e94636f72607f028bb8e4e392710 (MD5)
Previous issue date: 1990 / Doutorado / Genetica / Doutor em Ciências Biológicas
|
95 |
A eficiência dos instrumentos de controle da poluição, o caso do controle da poluição da água no Estado de São Paulo / The pollution control instruments efficiency, the pollution control in São Paulo EstateAstrom, Jan Ake Lennart 01 September 1995 (has links)
O controle da poluição é uma tarefa que envolve uma estrutura inter-disciplinar, abrangendo desde aspectos de ética até questões ecológicas. O papel da economia, nesta estrutura, não se restringe ao cálculo da relação benefício/custo. Sua principal função é de formuladora de modelos que permitem compreender o processo da poluição e do comportamento dos agentes poluidores frente às políticas (e instrumentos) de controle da mesma. Com o objetivo de avaliar a eficiência do programa de controle da poluição em água, adotado no Estado de São Paulo, o presente trabalho é dividido em três partes. Inicialmente são discutidas as causas da poluição e as soluções "first-best" e "second-best". Na segunda parte são discutidos os modelos de funcionamento e quantificação dos instrumentos de controle da poluição. Finalmente são apresentados a situação da poluição aquática no Estado, a estrutura institucional correlata ao seu controle e a descrição da política adotada. Também é feita uma análise comparativa dos instrumentos entre si, permitindo identificar aqueles de maior aplicabilidade e a comparação dos mesmos com a política adotada no Estado de São Paulo. / The pollution control is an inter-disciplinary matter, involving from ethical to ecological aspects. The roll of economics is not restricted to the calculation of cost/benefit ratios. Its most relevant function is to formulate models wich allows one to better understand the pollution process and the polluters behavior against pollution control policies. The aim of this study is to evaluate the water pollution control program adopted in the state of São Paulo. The work is di vided into three parts. Firstly the causes of pollution and the first and second-best solutions are discussed. Following that, pollution control's policies are discussed. Finally, policies adopted in the estate of São Paulo and the institutional organization of the State Environmental Protection Agency, are presented and discussed.
|
96 |
Avaliação do desempenho do tensiômetro de bolha de ar na medida do potencial matricial da água no solo / Evaluation of the simplified direct reading "air pocket" tensiometer for matric water potencial measurementsVilla Nova, Marcos Schiavon 19 November 1991 (has links)
O tensiômetro de leitura direta (TBA) foi desenvolvido para substituir o tensiômetro convencional (TC) em medidas de potencial da água no solo. Para testar a performance do instrumento um experimento .foi conduzido em condições de laboratório. Seis vasos foram preenchidos com cerca de 15 kg de solo arenoso e seis com cerca de 13 kg solo argiloso (solo seco ao ar). No centro dos vasos foram instalados seis tensiômetros de 1eitura direta e seis tensiômetros convencionais. Os vasos com tensiômetros foram saturados, cobertos com plástico e conduzidos a drenar por vários dias, após os quais, o plástico foi retirado iniciando-se um ciclo de secagem do solo. Cada vaso foi pesado diariamente para determinar-se a umidade do solo (e). Os tensiômetros foram lidos duas vezes ao dia (às 9:00hs e 15:00hs). Em função disto foi possível estabelecer-se relações de dependência entre Ψ e e para os dois tensiômetros, para cada tipo de solo. Estudou-se também o efeito da pressão atmosférica e temperatura na resposta dada pelo TBA. Verificou-se que o TBA tem um tempo de resposta mais baixo do que o TC sendo que os resultados obtidos indicaram que o TBA pode substituir o TC sem perda de precisão. As seguintes regressões lineares entre TBA e Te foram determinadas (descritas na dissertação). / The direct reading "air pocket" tensiometer (APT) was developed to substitute the conventional tensiometer (CT) in field measurements of soil water status (matric water potential Ψm). In order to test the performance of such instrument an experiment was conducted under laboratory conditions, where 5 containers were filled with about. 22 kg of a dry sandy soil and other six with abont 13 kg of a dry clayey soil. Each container received either a CT or a APT in the center of the soil volume. The containers were then saturated, covered with plastic and left to drain the excess water for several days. Plastic covers were removed to begin a drying cycle, being each container weighted daily in order to estimate its soil water content (e). The tensiometers were read twice a day (at 9 a.m. and at 4:0 p.m.). Therefore, it was possible to establish the relationship Ψ versus e for both, the CT and the APT for each soil type. It was possible to determine the effect of both, air pressure and temperature, upon the results given by the APT. The APT had a 1ower ti me response than the CT. Therefore, the results obtained here indicate that the DRT can replace the CT without precision loss. The following linear regressions between ΨAPT and ΨCT were found (described in the dissertation).
|
97 |
Efeito de parâmetros operacionais e uso de catalisador na redução eletrolítica de nitrato em célula de dois compartimentos com eletrodo de cobreBeltrame, Thiago Favarini January 2018 (has links)
A contaminação de águas por nitrato tornou-se um problema mundial devido aos seus altos teores em águas superficiais e subterrâneas, sendo a contaminação proveniente, principalmente, do uso de fertilizantes. Diversos são os meios de tratamento da água contaminada com nitrato, como por exemplo, a eletrodiálise e a osmose reversa. Esses dois tipos de tratamento geram soluções concentradas do íon em questão, que necessita de pós tratamento. Logo, este estudo objetiva o tratamento de água contaminada com alta concentração de nitrato por meio dos processos de eletrorredução e eletrocatálise em célula de dois compartimentos separados por uma membrana catiônica. Metodologicamente fez-se os experimentos em dois tipos de células, denominadas A e B. Em um primeiro momento foram realizados testes em uma célula de eletrorredução, somente com eletrodo de cobre no compartimento catódico, célula A, com circulação de solução provida por bombas centrífugas. Após, passou-se a utilizar catalisador juntamente com eletrodo plano de cobre, bem como eletrodos na forma de esponjas, em uma célula de menor volume (célula B), com agitação magnética. Foram testados diferentes parâmetros operacionais nestas células: concentração inicial de nitrato, densidade de corrente, variação de vazão e pH, uso de diferentes potenciais da célula, uso de catalisador paládio e modo de operação potenciostático. Na célula A, os melhores resultados em modo galvanostático, com eficiente redução do íon nitrato e reprodutibilidade dos experimentos, foi obtido quando utilizado a concentração inicial de nitrato de 600 mg L-1 e densidade de corrente de 1,1 mA cm-2, sendo percebido que, com o aumento da densidade de corrente, tem-se um pequeno aumento na redução do íon nitrato na solução. Nesta configuração de célula, nos diferentes parâmetros operacionais, o produto formado foi predominantemente o íon nitrito, principalmente quando mantido o potencial da célula constante. Visando aumentar a formação de compostos gasosos e diminuir a formação de nitrito, fez-se experimentos em uma célula B, em que se usou catalisadores com paládio. Nesta configuração de célula foi utilizado catalisador suportado em pó/alumina, pellets/alumina e fibras de carbono ativado. O uso do catalisador na forma de pó aumentou a formação dos compostos gasosos, porém o catalisador apresentava dificuldades no seu manuseio, então foram sintetizados catalisadores na forma de pellets. Quando utilizado os pellets, os melhores resultados para a formação de compostos gasosos foram alcançados quando aplicada uma densidade de corrente de 1,5 mA cm-2, com ajuste de pH em 6,0 - 6,5 e com teor de paládio de 2,5%. O uso de fibras de carbono ativado com 3% de paládio, aplicando uma densidade de corrente de 2,0 mA cm-2 e com ajuste de pH entre 6,0 - 6,5, apresentou uma seletividade de 95% para compostos gasosos. Nesta configuração de célula, ainda, fez-se testes em modo potenciostático, em que o potencial do eletrodo de cobre (placa) foi mantido em -0,9 VAg/AgCl, sendo formado, principalmente, o íon nitrito e apresentando uma menor redução de nitrato se comparado com o modo galvanostático. Por fim, foram testados eletrodos na forma de esponjas, na célula B, em que utilizando um eletrodo de níquel há um aumento na seletividade para compostos gasosos, enquanto que o uso de cobre priorizou a formação de nitrito, o paládio favoreceu a formação do íon amônio e compostos gasosos. Pode-se concluir que o uso de eletrorredução e eletrocatálise com eletrodo de cobre em célula de dois compartimentos mostrou-se eficiente para a redução de nitrato em altas concentrações. Parâmetros operacionais como pH, concentração de nitrato, densidade de corrente e estrutura do catalisador demonstraram-se essenciais na redução do íon nitrato e formação dos produtos provenientes desta redução. / Nitrate contamination of water has become a problem worldwide, with high nitrate levels detected in surface water and groundwater, which results mainly from the use of fertilizers. Different methods are available to treat nitrate-contaminated water, such as electrodialysis and reverse osmosis. These treatments generate concentrated solutions of a given ion, which require further treatment. Thus, this study aims to treat contaminated water with high nitrate concentrations employing electroreduction and electrocatalysis processes in a cell with two compartments separated by a cation exchange membrane. Experiments were carried out in two types of cells, denominated A and B. First, tests were performed in an electrolytic cell, with only a copper electrode in the cathode compartment (cell A) and solution circulation generated by centrifugal pumps. Next, a catalyzer was used with a plain copper electrode, along with sponge electrodes, in a cell with smaller volume (cell B) and magnetic stirring. Different operational parameters were tested in these cells: initial nitrate concentration, current density, flow and pH variation, use of different cell potentials, use of palladium catalyst, and potentiostatic operation mode. In cell A, the best results in the galvanostatic mode, with efficient reduction of nitrate ion and experimental reproducibility, were obtained with an initial nitrate concentration of 600 mg L-1 and a current density of 1.1 mA cm-2; with the increase in current density there was a slight increase in nitrate reduction in the solution. In this cell configuration, for the different operational parameters, the product formed was predominantly nitrite ion, especially when cell potential was kept constant. In order to improve the gaseous compounds production, decreasing the nitrite formation, experiments in cell B with palladium catalysts were carried out. In this cell configuration, catalyst supports with powder/alumina, pellets/alumina and activated carbon fibers were employed. The powder catalyst increased the formation of gaseous products; however, it was difficult to handle it, and thus pellet catalysts were synthesized. When pellets were used, the best results for the formation of gaseous products were obtained when a current density of 1.5 mA cm-2 was applied, with pH between 6.0 – 6.5 and palladium content of 2.5%. The use of activated carbon fibers with 3% palladium, applying a current density of 2.0 mA cm-2 and pH 6.0 – 6.5, presented a 95% selectivity for gaseous compounds. Furthermore, with this cell configuration, tests were carried out in the potentiostatic mode, with the potential of the copper electrode (plate) maintained at -0.9 VAg/AgCl. Nitrite ion was the main product, with decreased nitrate reduction in comparison with the galvanostatic mode. Finally, sponge electrodes were tested in cell B, in which the use of a nickel electrode resulted in increased selectivity for gaseous compounds, while the use of copper prioritized nitrite formation, and palladium favored the formation of ammonium ion and gaseous compounds. In conclusion, the use of electroreduction and electrocatalysis with a copper electrode in a two-compartment cell was efficient to reduce nitrate in high concentrations. Operational parameters such as pH, nitrate concentration, current density and catalyst structure were determinant for nitrate ion reduction and formation of its products.
|
98 |
Caracterização química das sementes de Moringa oleifera e sua utilização na potabilização da águaBelo, Lúcio, 1988-, Simionatto, Edésio Luiz, 1962-, Rau, Martinho, 1983-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Química. January 2017 (has links) (PDF)
Orientador: Edésio Luiz Simionatto. / Coorientador: Martinho Rau. / Dissertação (Mestrado em Química) - Programa de Pós-Graduação em Química, Centro de Ciências Exatas e Naturais, Universidade Regional de Blumenau, Blumenau.
|
99 |
Desenvolvimento de equipamento de monitoramento contínuo da floculaçãoAtila Brizola Ribas 06 December 2013 (has links)
O tratamento de água consiste em um sistema composto de diferentes etapas, dentre as quais a importância da floculação deve ser destacada, uma vez que as etapas seguintes à floculação em uma Estação de Tratamento de Água (ETA) são extremamente dependentes das características dos flocos formados. Desta maneira, o presente trabalho tem por objetivo precípuo desenvolver um equipamento para monitoramento contínuo da floculação, a partir da aquisição de peças no mercado interno, escolha do software de interação, montagem e teste do protótipo e elaboração do manual de montagem. Foram realizados testes de validação do equipamento por meio de ensaios em Jar Test, dentre os quais: a) variações na turbidez da água de estudo (5 a 1000 NTU), b) variação da intensidade de luminosidade, c) robustez do software utilizado para aquisição de dados bem como do microcontrolador. A vazão de estudo foi de 20 mL.min-1 e o coagulante utilizado foi o sulfato de alumínio com teor de Al2O3 de 8,35%. O equipamento forneceu um indicador muito sensível à formação de agregados a partir de informações valiosas dos estágios de formação dos flocos desde seu início, tornando-se opção muito eficaz para monitoramento contínuo (on-line) o qual é ideal para acompanhamento da operação da floculação em ETAs. Observou-se que o equipamento também não sofreu interferência de fouling - fenômeno causado pela incrustação -, para as condições de estudo. O equipamento desenvolvido apresentou resultados que condizem com àqueles já apresentados na literatura, seja para crescimento, quebra e recrescimento de flocos, o que demonstra sua aplicabilidade. Finalmente, foram elaborados manuais de montagem e operação do equipamento.
|
100 |
Contribuição a determinação da vazão sólida de arrastes em leitos arenosos, utilizando técnicas radioisotópicas / Not available.Sanchez, Wladimyr 05 March 1974 (has links)
Não disponível. / Not available.
|
Page generated in 0.0192 seconds