Spelling suggestions: "subject:"ácido glicólico"" "subject:"acido glicólico""
1 |
PLA/PGA copolymer as a bone substitute in maxillary sinus augmentation: histological, histometric and immunohistochemistry study in rabbitsFerreira, Sabrina [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-03Bitstream added on 2015-03-03T12:06:37Z : No. of bitstreams: 1
000800427.pdf: 8452943 bytes, checksum: c40ffd64f5262a9010864dacab63d5d7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A proposta deste estudo foi avaliar a capacidade osteocondutora da forma sólida do copolímero de PLA/PGA em um modelo experimental de enxerto em seio maxilar . Vinte coelhos machos, branco, da raça Nova Zelândia, cada um pesando cerca de 3,0 kg, foram utilizados e foram divididos em dois grupos de acordo com o material de preenchimento do seio, como segue: ósseo autógeno particulado e copolímero PLA/PGA . A área aumentada diferiu entre os grupos após 3, 7 e 15 dias (p = 0,004) . No entanto, os valores tornaram-se semelhante aos 40 dias (p = 0,458). Depois de 3 e 7 dias, a porcentagem óssea foi estatisticamente significativa entre osso autógeno e PLA / PGA copolímero (P = 0,004 e P = 0,004). Após 15 e 40 dias os valores foram semelhantes nos dois períodos (P = 0,087 e P = 0,087 ). Imunohistoquímica confirma os resultados sobre os dados histomorfométricos. Em conclusão, o copolímero de PLA/PGA parece ser adequado como material reabsorvível capaz de induzir o crescimento do osso em defeitos ósseos. Esta observação sugere que o material tem propriedades osteocondutoras também apropriado para aplicação em cirurgia maxilo-facial / The proposition of this study was evaluate the osteoconductive capability of the solid form of PLA/PGA copolymer in an experimental model of maxillary sinus grafting. Twenty male white New Zealand rabbits, each weighing about 3.0kg, were used and were divided into two groups, according to the sinus filling material, as follows: autogenous bone chips and PLA/PGA copolymers. Augmented area differ between the groups after 3, 7 and 15 days (P=0.004). However, the values became similar on day 40 (P=0.458). After 3 and 7 days the percentage of bone was statistically significant between autogenous bone and PLA/PGA copolymer (P=0.004 and P=0.004). After 15 and 40 days the values were comparable in the two periods (P=0.087 and P=0.087). Immunohistochemistry confirms the results on the histomorphometric data. In conclusion, PLA/PGA copolymer seems to be suitable as resorbable material able to induce bone growth in bone defects. This observation suggests that the material have osteoconductive properties also suitable for application in maxillofacial surgery
|
2 |
PLA/PGA copolymer as a bone substitute in maxillary sinus augmentation : histological, histometric and immunohistochemistry study in rabbits /Ferreira, Sabrina. January 2014 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Wilson Roberto Poi / Banca: Ronaldo Célio Mariano / A dissertação foi escrita em inglês / Resumo: A proposta deste estudo foi avaliar a capacidade osteocondutora da forma sólida do copolímero de PLA/PGA em um modelo experimental de enxerto em seio maxilar . Vinte coelhos machos, branco, da raça Nova Zelândia, cada um pesando cerca de 3,0 kg, foram utilizados e foram divididos em dois grupos de acordo com o material de preenchimento do seio, como segue: ósseo autógeno particulado e copolímero PLA/PGA . A área aumentada diferiu entre os grupos após 3, 7 e 15 dias (p = 0,004) . No entanto, os valores tornaram-se semelhante aos 40 dias (p = 0,458). Depois de 3 e 7 dias, a porcentagem óssea foi estatisticamente significativa entre osso autógeno e PLA / PGA copolímero (P = 0,004 e P = 0,004). Após 15 e 40 dias os valores foram semelhantes nos dois períodos (P = 0,087 e P = 0,087 ). Imunohistoquímica confirma os resultados sobre os dados histomorfométricos. Em conclusão, o copolímero de PLA/PGA parece ser adequado como material reabsorvível capaz de induzir o crescimento do osso em defeitos ósseos. Esta observação sugere que o material tem propriedades osteocondutoras também apropriado para aplicação em cirurgia maxilo-facial / Abstract: The proposition of this study was evaluate the osteoconductive capability of the solid form of PLA/PGA copolymer in an experimental model of maxillary sinus grafting. Twenty male white New Zealand rabbits, each weighing about 3.0kg, were used and were divided into two groups, according to the sinus filling material, as follows: autogenous bone chips and PLA/PGA copolymers. Augmented area differ between the groups after 3, 7 and 15 days (P=0.004). However, the values became similar on day 40 (P=0.458). After 3 and 7 days the percentage of bone was statistically significant between autogenous bone and PLA/PGA copolymer (P=0.004 and P=0.004). After 15 and 40 days the values were comparable in the two periods (P=0.087 and P=0.087). Immunohistochemistry confirms the results on the histomorphometric data. In conclusion, PLA/PGA copolymer seems to be suitable as resorbable material able to induce bone growth in bone defects. This observation suggests that the material have osteoconductive properties also suitable for application in maxillofacial surgery / Mestre
|
3 |
Avaliação da resposta tecidual a discos de ácido poli-l/d láctico: estudo experimental em ovelhasCielo, Vinícius Flores January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2
000427033-0.pdf: 1511979 bytes, checksum: 5e65b939e0aae98244311352791e72a9 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the inflammatory reaction, more specifically the foreign body reaction and behavior of bone remodeling in sheep’s tibiae and ulnae after installation of copolymer discs consisting of 95% poly-L lactic acid and 5% acid poly-D Lactic (PLDLA). It was used two adult female sheep which was fixed, by screws, for circular discs of PLDLA in each tibia and ulna of the sheep. A total of 16 discs were fixed in each animal. The sheeps were randomly divided into two groups according to the time of death after surgery: 30 and 60 days. Subsequently the samples were processed, resulting in a slide for each sample. After that the slides were investigated in optical microscope with magnification of 40 x and 100 x. In the slices of periosteal were evaluated the inflammatory infiltrate in a descriptive way in an increase of 40 X and quantitatively, by counting inflammatory cells in five random fields per sample in an optical microscope in an increase of 100 X. The inflammatory density was quantified according to the following scale: grade 0 - absence of inflammatory infiltrate, grade 1 - less than 30 cells per field, grade 2 - 30 to 100 cells per field and grade 3 - greater than 100 cells per field. In bone tissue it was analyzed two random fields per sample and if some bone resorption area appeared in the area of contact with the discs, this was described. In the end of the study, histological sections of the both groups showed tissue composed of organized fibroblasts and the inflammatory infiltrate varied from absent to mild. Talking about bone resorption, it had association with compression of the discs to the bone tissue, without evidence of bone resorption caused by the discs. At the end of the study verified biocompatibility, abscense of osteolisys at macroscopic view, disc structure undefformed and appropriated fit between titanium screw and PLDLA disc. / O objetivo desse estudo foi avaliar a reação inflamatória, mais especificamente a reação de corpo estranho, e o comportamento de remodelação óssea em tíbias e ulnas de ovelhas, após instalação de discos de um copolímero constituído de 95% de ácido Poli-L Láctico e 5% de ácido Poli-D Láctico (PLDLA). Foram utilizadas duas ovelhas fêmeas adultas em que se fixaram, através de parafusos, quatro discos circulares de PLDLA em cada tíbia e ulna das ovelhas, totalizando 16 discos em cada animal. As ovelhas foram aleatoriamente divididas em dois grupos, de acordo com o período de morte após a cirurgia: 30 e 60 dias. Posteriormente as amostras foram processadas, obtendo-se uma lâmina por amostra, que foram investigadas ao microscópio óptico com aumentos de 40x e 100x. Nas lâminas de periósteo avaliou-se o infiltrado inflamatório de forma descritiva, em um aumento de 40 X, e de forma quantitativa, pela contagem de células inflamatórias em cinco campos aleatórios por amostra no microscópio óptico, em aumento de 100 X. A densidade inflamatória foi quantificada conforme a seguinte escala: grau 0 – ausência de infiltrado inflamatório, grau 1 – menor que 15 células por campo, grau 2 – 15 a 50 células por campo e grau 3 – maior que 50 células por campo. O tecido ósseo foi analisado macroscopicamente, e havendo área de reabsorção óssea na área de contato com os discos, esta foi descrita. Observou-se ao final do estudo que as secções histológicas dos grupos 30 de 60 dias apresentavam tecido conjuntivo composto por fibroblastos maduros, organizados e o infiltrado inflamatório variava de ausente a leve. Em relação à reabsorção óssea há associação com a compressão dos discos ao tecido ósseo, não havendo indícios de reabsorção óssea causadas pelos discos. No final do estudo verifica-se biocompatibilidade, ausência de osteólise a nível macroscópico, manutenção da estrutura do disco e adequada associação entre o parafuso de titânio e disco de PLDLA.
|
4 |
Avaliação da interface osso/implante após o uso do copolímero de PLA/PGA associado a osso autógeno em coelhos: estudo biomecânico e imunohistoquímicoZanetti, Liliane Scheidegger da Silva [UNESP] 19 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-08-19Bitstream added on 2014-06-13T21:02:12Z : No. of bitstreams: 1
zanetti_lss_dr_araca.pdf: 1415676 bytes, checksum: 6158721af6f6a1ee60c101f886650479 (MD5) / Este estudo avaliou o uso do c opolímero de ácido poliláctico e poliglicólico (PLA/PGA) associado ao osso autógeno raspado, no reparo ósseo ocorrido ao redor de implantes inseridos em leitos sobrefresados, em tíbias de coelhos. (2) Material e métodos: Foram incluídos no estudo 20 coelhos e inseridos 40 implantes, divididos em dois grupos: Controle (C) e PLA/PGA adicionado a osso autógeno (G). Após fresagem controlada para simular a perda da estabilidade primária, cada implante foi inserido no leito preparado, tendo sido adicionado a sua superfície o copolímero PLA/PGA associado a osso autógeno raspado obtido manualmente. O grupo controle consistiu do implante com o espaço do leito preenchido por coágulo sangüíneo. Os animais foram sacrificados nos períodos de 15, 40 e 60 dias pós-operatórios, e foram realizadas as análises biomecânica e Imunoistoquímica. As tíbias onde estavam inseridos os implantes foram removidas, desc alcificadas, crioprotegidas e obtidos cortes que foram submetidos à reação imunoistoquímica mediante a utilização de anticorpos primários para RANKL, OPG e OC. No período de 60 dias pós-operatórios a analise biomecânica de torque-reverso foi realizada antes da descalcificação. (3) Resultados: Os resultados obtidos demonstraram que o copolímero PLA/PGA misturado ao osso autógeno apresentou-se biocompatível, bioabsorvivel e permitiu a neoformação óssea em contato com o implante, revelada pela análise da expressão das proteínas que regulam o ganho e a perda de massa óssea. E, houve predominância significante de deposição óssea e estabilidade revelada pela análise de torque-reverso (a= 0,05). (4) Conclusões: O copolímero de PLA/PGA pode ser utilizado no preenchimento de defeitos sobrefresados ao redor... / This study evaluated the polylactic and polyglycolic acid copolymer (PLA/PGA) with sc raped bone harvest in the bone repair occurrence of implants placed in large stream beds, in rabbit tibia. (2) Materials and Methods: Twenty rabbits had been enclosed in the study and 40 implants, in two groups: Control (C), PLA/PGA with the autologous bone scraped (G). After controlled drilled to simulate the loss of the primary stability, each implant was placed in the prepared stream bed, having been added to its surface the PLA/PGA copolymer with autologous bone scraped manually (G). The control group consisted of the implant placed in the space filled by blood. The animals had been sacrificed in the periods 15, 40 and 60 postoperative days, where the analyses had been carried through biomechanics and imunohistochemistry. The tibias where the implants were inserted had been removed, decalcified, frozen and getting cuts that had been submitted the imunoistochemistry reaction by means of the use of primary antibodies for RANK L, OPG and OC. In the 60 days period postoperative the against-torque biomechanics was carried through before the decalcified. (3) Results: The gotten results had disclosed that the copolymer PLA/PGA with bone graft showed biocompatibility, bioabsorption and allowed bone growing in contact with the implant, disclosed by expression of the proteins that regulate the profit and mass bone loss. And, had significant predominance of bone deposition and stability disclosed by against-torque ( = 0,05). (4) Conclusions: The PLA/PGA copolymer can be used filling defects drilled around implants in tibia of rabbits, when added bone harvest sc raped, therefore it presents characteristic s like biocompatibility and biodegradation, being totally resorpted and substituted by bone, allowing the bone formation with quality in the interface bone/implant.
|
Page generated in 0.0387 seconds