• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 6
  • 6
  • 6
  • 5
  • 3
  • 3
  • Tagged with
  • 60
  • 60
  • 28
  • 25
  • 23
  • 22
  • 21
  • 13
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desempenho de gotejadores com uso de efluente de esgoto doméstico tratado /

Pletsch, Talita Aparecida, 1984- January 2008 (has links)
Orientador: Raimundo Leite Cruz / Banca: Antonio Evaldo Klar / Banca: Tarlei Arriel Botrel / Resumo: O uso de águas residuárias de esgoto doméstico tratado permite uma otimização dos recursos hídricos disponíveis, melhorando assim a sua oferta. O uso para fins agrícolas a cada dia se mostra uma possibilidade vantajosa de reúso, pois aceita o uso de águas com qualidade inferior ao exigido pelo abastecimento urbano e necessita de grandes quantidades. Segundo Almeida et al.(2006), a uniformidade possui maior importância quando o sistema de irrigação é utilizado para fazer a fertirrigação, pois, para o bom desempenho, é necessário o conhecimento das características hidráulicas do emissor e uniformidade de aplicação de água do sistema de irrigação utilizado. Diante desta realidade de reúso de efluentes para irrigação por gotejamento, o presente trabalho teve como objetivo determinar a vazão dos gotejadores, a curva relação vazão-pressão, a sua equação característica, o coeficiente de variação de vazão (CVQ), e também avaliar a uniformidade de aplicação de água, calculando os seguintes coeficientes: coeficiente de uniformidade de distribuição (CUD), o coeficiente de uniformidade de Christiansen (CUC) e o coeficiente de uniformidade estatístico (CUE), do tubo gotejador da marca Netafim, modelo Tiran 17, utilizado para a irrigação com água residuária de esgoto doméstico tratado.O experimento foi realizado em uma bancada de ensaios no Laboratório de Irrigação da UNESP-FCA, Campus de Botucatu-SP. Foi utilizado um segmento do tubo gotejador contendo 25 emissores, onde se mediu a vazão com as seguintes pressões: 40, 50, 80, 100, 120, 150, 200, 250, 300 kPa, com quatro repetições para cada gotejador. Após os ensaios, o tubo gotejador foi submetido a 1000 horas de trabalho com água residuária de esgoto doméstico tratado. Foram realizados os mesmos ensaios iniciais após 500 horas e 1000 horas de trabalho com água tratada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of wastewater of treated household drain allows an optimization of available hydro resources, increasing the offer of a scarce product. The use in agriculture becomes, each day, more advantageous for its reuse due to its acceptance of water with a lower quality in view of the water demanded by the urban supply and the demanding of a great quantity. According to Almeida et al.(2006), the uniformity is more important when the system of irrigation is used to make the fertirrigation. For a good performance it's important to know the hydraulic characteristics of the emitter and uniformity of water application of the irrigation system. In order of the reuse of effluents for drip irrigation, this paper aims to determine the flow of drippers, the curve relation flow-pressure, its equation, the flow coefficient of variation (CVQ) as well as to evaluate the uniformity of water application by calculating the follow coefficients: distribution uniformity coefficient (CUD), Christiansen uniformity coefficient (CUC) and the statistical uniformity coefficient (CUE) of the drip pipeof the Netafim brand, model Tiran 17, used for irrigation with wastewater of treated household drain. The experiment was accomplished in a test bank in the Irrigation Laboratory of UNESP-FCA, Campus of Botucatu in São Paulo state. It was used 25 drippers where the flow was measured with increasing pressures of 40, 50, 80, 100, 120, 150, 200, 250, 300 kPa, with four repetitions for each dripper. After the tests the drip pipe was submitted to 1000 hours of work with wastewater of treated household drain. The same tests were carried out after 500 hours and 1000 hours of working but with treated water. The results of the new pipe after the 500 working hours with treated household effluents for CVQ, were classified as good, according to the ABNT (1987) chart. The CUD, CUC and CUE not only before but also... (Complete abstract click electronic access below) / Mestre
52

Estudo da eficiência da desinfecção solar de águas residuárias domésticas em reatores de diferentes colorações /

Queluz, João Gabriel Thomaz, 1985- January 2013 (has links)
Orientador: Rodrigo Máximo Sánchez Román / Banca: Raimundo Leite Cruz / Banca: Marcos Vinicius Folegatti / Resumo: A utilização de água residuária doméstica (ARD) na agricultura irrigada exige medidas de desinfecção para garantir padrões de qualidade e proteger a saúde humana dos patógenos presentes. Raios UV são eficientes para esta finalidade e há diversos relatos de sistemas de desinfecção solar (SODIS - solar disinfection), tanto para a desinfecção de água para consumo humano quanto para a desinfecção de ARD. Não há estudos sobre a eficiência da desinfecção de ARDs utilizando-se diferentes revestimentos nos reatores solares de concreto. O objetivo do presente trabalho foi avaliar a eficiência da desinfecção solar de ARD para reúso na agricultura em reatores solares com diferentes colorações: preta, branca e concreto. A ARD, após passar pelo tanque séptico, era conduzida aos reatores, formando lâminas de água residuária com 10 cm de profundidade, que ficavam expostas à radiação solar durante três dias consecutivos. A eficiência da desinfecção foi avaliada pela concentração de coliformes fecais (CF), demanda química de oxigênio (DQO), temperatura do efluente, radiação global, radiação UV, pH e sólidos suspensos totais (SST). Os dados foram analisados utilizando-se análise de regressão propondo-se um modelo matemático que representa a inativação de patógenos. O efluente do tanque séptico utilizado na desinfecção solar apresentou em média os seguintes padrões de qualidade: 1,29 x 106 NMP 100mL-1 (Número mais provável a cada 100ml), 654,96 mgDQO L-1, 180,33 mgSST L-1 e 6,17 de pH. Durante o processo constataram-se melhorias nos padrões DQO e SST nos reatores. / Abstract: The use of domestic wastewater (DWW) in irrigated agriculture requires disinfection measures to protect human health from pathogens. UV rays are effective for this purpose and there are many reports of solar disinfection (SODIS) systems, for both disinfection of drinking water and disinfection of DWW. The literature does not present any studies on the disinfection efficiency of DWW using different colors in concrete solar reactors. The aim of this study was to evaluate the efficiency of DWW solar disinfection for agriculture reuse in solar reactors with different colors: black, white and concrete. DWW, after passing through the septic tank was conducted to the reactors until the water depth reach 10 cm that was exposed to sunlight for three consecutive days. The disinfection efficiency was evaluated by the concentration of fecal coliforms (FC), chemical oxygen demand (COD), effluent temperature, global radiation, UV radiation, pH and total suspended solids (TSS). The data were analyzed using regression analysis and a mathematical model that represents the inactivation of pathogens was proposed. The effluent from the septic tank used for solar disinfection had the following mean quality standards: 1.29 x 106 MPN 100mL-1 654.96 mgCOD L-1, 180.33 mgSST L-1 and pH 6.17. During the process it was noticed improvement in COD as well as TSS concentration in the reactors. Furthermore, the results show that the effluent in different reactors had distinct temperatures: the highest rates were observed in the black reactor ... / Mestre
53

Estratégias visando o uso sustentável de água salina em um ciclo de rotação cultural feijão-de-corda/girassol / Strategies for the sustainable use of saline water in the cultivation of cowpea

Neves, Antônia Leila Rocha January 2012 (has links)
NEVES, Antônia Leila Rocha.Estratégias visando o uso sustentável de água salina em um ciclo de rotação cultural feijão-de-corda/girassol. 2012. 159 f. : Tese (doutorado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Engenharia Agrícola, Programa de Pós-Graduação em Engenharia Agrícola, Fortaleza-CE, 2015. / Submitted by demia Maia (demiamlm@gmail.com) on 2016-08-01T16:31:10Z No. of bitstreams: 1 2015_tese_alrneves.pdf: 5244793 bytes, checksum: 9b9ea12c8d4f13c6be11e4de21f8c5db (MD5) / Approved for entry into archive by demia Maia (demiamlm@gmail.com) on 2016-08-02T13:19:34Z (GMT) No. of bitstreams: 1 2015_tese_alrneves.pdf: 5244793 bytes, checksum: 9b9ea12c8d4f13c6be11e4de21f8c5db (MD5) / Made available in DSpace on 2016-08-02T13:19:34Z (GMT). No. of bitstreams: 1 2015_tese_alrneves.pdf: 5244793 bytes, checksum: 9b9ea12c8d4f13c6be11e4de21f8c5db (MD5) Previous issue date: 2012 / The world population growth and increasing demand for water to meet household consumption and other sectors of the economy, have awakened for the use of alternative sources or water of inferior quality, such as saline water and wastewater. The aim of this study was a preliminary assessment of the situation of desalination plants installed by the State Government of Ceara in the region of Pentecoste, Ceará, and then to evaluate irrigation management strategies (cyclic use of saline water, mixture of water of different salinities and use only in stages of tolerant phase of crop) and the system of crop rotation cowpea/sunflower, aiming at the sustainable use of saline water in irrigated agriculture. The experiment with the cowpea was conducted in the dry season of 2011, and followed the randomized block design, with thirteen treatments and five replications. The treatments were: T1: low salinity water (A1), throughout the cycle, T2, T3 and T4: Water with CE 2.2 (A2), 3.6 (A3) and 5.0 (A4) dS m-1, throughout the cycle, T5, T6 and T7: Water with EC of 2.2, 3.6 and 5.0 dS m-1 in the final phase of the cycle, T8, T9 and T10: Use cyclic A1 and A2, A1 and A3 and A1 and A4, starting with A1 at sowing, T11, T12 and T13: Water of EC of 2.2, 3.6 and 5.0 dS m-1 after germination until the end of cycle. To verify the residual effect of saline water applied during the experiment with the cowpea, sunflower was grown in the rainy season of 2012 in the same plots that were cultivated with cowpea, using supplementary irrigation with water of low salinity. The EC of the desalination waste in the region of Pentecoste ranged from 4.2 to 7.6 dS m-1, representing a risk for the environment, where much of the waste generated is used to feed the vast majority of population is not aware if the reject cause any harm to human health or to the environment. The results of field experiments showed that the use of saline water during the entire cycle of the cowpea up to the level of 5.0 dS m-1 and after germination until the end of the cycle inhibits leaf gas exchange, extraction of nutrients, plant growth and crop yield, while the strategies of irrigation with saline water in the final phase of the crop cycle (flowering and fruiting) and cyclically not negatively affect these variables. Further, these strategies allow a saving 34-47% water of low salinity used for irrigation. There was accumulation of salts in the soil for the cultivation of cowpea of the treatments which used water of high salinity. However, the use of strategies for managing the application of alternating high and low water salinity crop cycle and application of the salt water only in the final stage reduced the impact on soil. The irrigation water of low salinity (0.5 dS m-1) promoted excessive leaching of salts in the soil at the end of sunflower cultivation, but the amount of rainfall before seeding was not sufficient to completely eliminate the residual effect of salinity in the crop. / O crescimento da população mundial e a crescente demanda de água para atender o consumo das famílias e os demais setores da economia, têm despertado para o aproveitamento de fontes alternativas ou águas de qualidade inferior, tais como as águas salinas e residuárias. O objetivo desse trabalho foi realizar uma avaliação preliminar sobre a situação dos dessalinizadores instalados pelo Governo do Estado do Ceará na região de Pentecoste, Ceará, e, em seguida, avaliar estratégias de manejo da irrigação (uso cíclico de água salina, mistura de fontes de água de diferentes salinidades e utilização apenas nos estádios de maior tolerância da cultura) e o sistema de rotação de culturas feijão-de-corda/girassol, visando o uso sustentável de água salina na agricultura irrigada. O experimento com feijão-de-corda foi conduzido no campo na estação seca de 2011, e obedeceu ao delineamento em blocos ao acaso, com treze tratamentos e cinco repetições. Os tratamentos consistiram de: T1: Água de baixa salinidade (A1), durante todo o ciclo; T2, T3 e T4: Água com CE de 2,2 (A2), 3,6 (A3) e 5,0 (A4) dS m-1, durante todo o ciclo, T5, T6 e T7: Água com CE de 2,2, 3,6 e 5,0 dS m-1 na fase final do ciclo, T8, T9 e T10: Uso cíclico de A1 e A2; A1 e A3 e A1 e A4, iniciando com A1 no plantio; T11, T12 e T13: Água com CE de 2,2, 3,6 e 5,0 dS m-1 11 dias após o plantio até o final do ciclo, respectivamente. Para verificar o efeito residual de água salina aplicada durante o experimento com o feijão-de-corda, foi cultivado na estação chuvosa de 2012 o girassol nas mesmas parcelas que foram cultivadas com o feijão-de-corda, utilizando irrigação suplementar com água de baixa salinidade (A1). Os valores de CEa para o rejeito de dessalinização na região de Pentecoste variaram de 4,2 a 7,6 dS m-1, representando riscos para o ambiente, sendo que a maior parte do rejeito gerado é utilizada para alimentação animal e a grande maioria da população não tem conhecimento se o rejeito causa algum dano à saúde humana ou ao meio ambiente. Os resultados dos experimentos de campo demonstraram que a aplicação de água salina durante todo o ciclo do feijão-de-corda ao nível de 5,0 dS m-1 e após a 11 dias do plantio até o final do ciclo inibe as trocas gasosas foliares, a extração de nutrientes, o crescimento vegetativo e a produtividade da cultura, enquanto as estratégias de irrigação com água salina na fase final do ciclo (floração e frutificação) e de forma cíclica não afetam de forma negativa essas variáveis. Além disso, essas estratégias permitiram uma economia de 34 a 47% de água de baixa salinidade utilizada na irrigação. Ocorreu acúmulo de sais no solo durante o cultivo do feijão-de-corda nos tratamentos em que se utilizou água de elevada salinidade. No entanto, o uso de estratégias de manejo como a aplicação alternada de águas de baixa e alta salinidade ao longo do ciclo da cultura e aplicação da água salina apenas no estádio final reduziu o impacto sobre o solo. A irrigação com água do canal (A1) com CE de 0,5 dS m-1 durante o cultivo do girassol promoveu a lixiviação do excesso de sais no solo no final do cultivo, mas o total de chuvas antes do plantio não foi suficiente para eliminar completamente o efeito residual da salinidade nesta cultura.
54

Reuso de água e resíduos gerados pela lavagem de caminhões betoneiras: análise do efeito na resistência à compressão de concreto usinado / Reuse of water and waste generated by the washing of concrete mixer trucks: analysis of the effect on resistance to ready-mix concrete compression

Malaguti, Vilmar dos Santos 08 March 2016 (has links)
O objetivo deste trabalho é analisar a resistência à compressão do concreto e seus possíveis efeitos com o reuso da água e dos resíduos de lavagens dos caminhões betoneiras. A revisão bibliográfica sobre o assunto proposto foi estudado e discutido em países como Grécia, Taiwan, Alemanha, Itália, Cingapura e outros, o que serviu de apoio e reforço para este trabalho. O método para analisar a resistência à compressão foi de comparação entre uma amostra controle (traço padrão de 30 MPa) e amostras com diferentes composições. O resultado de cada amostra foi diferente em função de sua composição, no entanto, pode-se afirmar ganho econômico na ordem de 20,21 R$/m3, além da resistência à compressão ser maior que 90% da amostra controle. As análises realizadas nas amostras através de DRX, MEV e EDS comprovaram que não houve síntese de novos minerais, somente pequenas quantidades (menor do que os limites de detecção do método de DRX) de alumino-silicatos e quartzo dissolvidos que foram sintetizados em novos minerais cristalinos, que podem ser atribuídos como substancias amorfas em estado sol-gel. Com o resultado observa-se que o reuso da água de lavagem dos caminhões betoneiras não interferem na resistência à compressão de novos concretos, assim como o resíduo de lavagem que não apresentou nenhum elemento diferente do composto no cimento, também não interfere na resistência à compressão de novos concretos, desde que haja controle da água presente. / The objective of this study is to analyze the strength of concrete compression and its possible effects on water reuse and waste washes of concrete mixer trucks. The literature review on the proposed subject was studied and discussed in countries like Greece, Taiwan, Germany, Italy, Singapore and others, which served as support and reinforcement for this work. The method for analyzing the compressive strength was compared between the control sample (standard stroke 30 MPa) and samples with different compositions. The result of each sample was different depending on their composition, however, it can be stated economic gain on the order of 20,21 R$/m3, in addition to the compressive strength is greater than 90% of the control sample. The samples were analyzed by DRX, MEV and EDS showed that there was no synthesis of new mineral, only small amounts (lower than the detection limits of the DRX method) dissolved alumino-silicates and quartz which have been synthesized into new mineral crystalline, which can be assigned as amorphous substances in sol-gel state. With this result it was observed that the reuse of the concrete mixer trucks washing water does not interfere with the compressive strength of new concrete, as well as the washing residue which presented no different element of the compound in cement, does not interfere with the compressive strength new concrete, provided that control of the water present.
55

Reuso de água e resíduos gerados pela lavagem de caminhões betoneiras: análise do efeito na resistência à compressão de concreto usinado / Reuse of water and waste generated by the washing of concrete mixer trucks: analysis of the effect on resistance to ready-mix concrete compression

Malaguti, Vilmar dos Santos 08 March 2016 (has links)
O objetivo deste trabalho é analisar a resistência à compressão do concreto e seus possíveis efeitos com o reuso da água e dos resíduos de lavagens dos caminhões betoneiras. A revisão bibliográfica sobre o assunto proposto foi estudado e discutido em países como Grécia, Taiwan, Alemanha, Itália, Cingapura e outros, o que serviu de apoio e reforço para este trabalho. O método para analisar a resistência à compressão foi de comparação entre uma amostra controle (traço padrão de 30 MPa) e amostras com diferentes composições. O resultado de cada amostra foi diferente em função de sua composição, no entanto, pode-se afirmar ganho econômico na ordem de 20,21 R$/m3, além da resistência à compressão ser maior que 90% da amostra controle. As análises realizadas nas amostras através de DRX, MEV e EDS comprovaram que não houve síntese de novos minerais, somente pequenas quantidades (menor do que os limites de detecção do método de DRX) de alumino-silicatos e quartzo dissolvidos que foram sintetizados em novos minerais cristalinos, que podem ser atribuídos como substancias amorfas em estado sol-gel. Com o resultado observa-se que o reuso da água de lavagem dos caminhões betoneiras não interferem na resistência à compressão de novos concretos, assim como o resíduo de lavagem que não apresentou nenhum elemento diferente do composto no cimento, também não interfere na resistência à compressão de novos concretos, desde que haja controle da água presente. / The objective of this study is to analyze the strength of concrete compression and its possible effects on water reuse and waste washes of concrete mixer trucks. The literature review on the proposed subject was studied and discussed in countries like Greece, Taiwan, Germany, Italy, Singapore and others, which served as support and reinforcement for this work. The method for analyzing the compressive strength was compared between the control sample (standard stroke 30 MPa) and samples with different compositions. The result of each sample was different depending on their composition, however, it can be stated economic gain on the order of 20,21 R$/m3, in addition to the compressive strength is greater than 90% of the control sample. The samples were analyzed by DRX, MEV and EDS showed that there was no synthesis of new mineral, only small amounts (lower than the detection limits of the DRX method) dissolved alumino-silicates and quartz which have been synthesized into new mineral crystalline, which can be assigned as amorphous substances in sol-gel state. With this result it was observed that the reuse of the concrete mixer trucks washing water does not interfere with the compressive strength of new concrete, as well as the washing residue which presented no different element of the compound in cement, does not interfere with the compressive strength new concrete, provided that control of the water present.
56

Mecanismos para promoção do reúso de água nas indústrias das bacias do Alto Iguaçu e afluentes do Alto Ribeira (PR) / Mechanisms to promote water reuse in the industries of the Alto Iguaçu e Afluentes do Alto Ribeira Basins (Pr)

Ratier, Cristiane 31 March 2017 (has links)
CAPES / A água é essencial para a vida no planeta e é necessária para diversas atividades humanas. Fatores como o crescimento demográfico, a expansão industrial e a progressiva urbanização, causaram o pronunciado aumento da demanda global de água, em concorrência com a redução da disponibilidade deste recurso natural. Assim, mesmo que haja volume de precipitações significativo, há risco de escassez hídrica. Desta equação resulta a necessidade premente de incentivar ações voltadas à economia e ao uso racional dos recursos hídricos. Como uma das práticas da gestão dos recursos hídricos, a adoção do reúso de água na indústria pode contribuir para a economia do insumo e a redução da poluição. O estudo parte da premissa de que a bonificação estabelecida pelo Comitê do Alto Iguaçu e Afluentes do Alto Ribeira (COALIAR), na Resolução nº 05/2013, não tem efetividade para incentivar o reúso de água. O COALIAR abrange parte da Região Metropolitana de Curitiba e municípios contíguos, no estado do Paraná. O objetivo da pesquisa é estudar os mecanismos de incentivo ao reúso de água vigentes na região do COALIAR. Como metodologia, foi utilizada a revisão bibliográfica, a pesquisa documental e a pesquisa de campo, por meio de entrevistas. Foram feitas entrevistas com atores envolvidos com recursos hídricos na região do COALIAR. A pesquisa classifica-se como descritiva e exploratória e para o tratamento dos dados foi adotada a abordagem qualitativa. Como conclusão, inferiu-se que para fomentar a prática de reúso de água são recomendáveis as normas premiais, em detrimento das normas punitivas. Os incentivos ao reúso de água podem ser estabelecidos por meio de descontos significativos, incidentes sobre valores cobrados pelo uso dos recursos hídricos, bem como por descontos e isenções fiscais. Considera-se, também, que o Poder Público deve divulgar amplamente os dados sobre os riscos de escassez hídrica e sobre os comportamentos que podem contribuir para a preservação da água. / Water is essential for life on the planet and it is necessary for various human activities. Factors such as population growth, industrial expansion and progressive urbanization have led to a pronounced increase in global water demand, in competition with reduced availability of this natural resource. Thus, even if there is significant precipitation volume, the risk of water scarcity is not excluded. From this equation results the urgent need to encourage actions aimed at the economy and the rational use of water resources. As one of the practices of water resources management, the adoption of water reuse in industry can contribute to the economy of the input and the reduction of pollution. The study starts from the premise that the subsidy established by the Comitê do Alto Iguaçu e Afluentes do Alto Ribeira (COALIAR), in Resolution number 05/2013, has no effect to encourage the reuse of water. The COALIAR covers part of the Metropolitan Region of Curitiba and contiguous counties contíguos, in the state of ParanaThe objective of the research is to study the water reuse incentive mechanisms in the region of the COALIAR. As a methodology, bibliographic review, documentary research and field research were used through interviews. Interviews were conducted with actors involved with water resources in the region of the COALIAR. The research is classified as descriptive and exploratory and for the treatment of the data, the qualitative approach was adopted. As a conclusion, it was inferred that to promote the practice of water reuse, it is recommended that the norms be awarded, to the detriment of punitive norms. Incentives for water reuse can be established through significant discounts, levied on amounts charged for the use of water resources, as well as discounts and tax exemptions. It is also considered that the Public Authorities should widely disseminate data on the risks of water scarcity and on the behaviors that may contribute to the preservation of water.
57

Eficácia do tratamento biológico em gotejadores operando com água residuária doméstica tratada / Effectiveness of biological treatment in drippers operating with domestic wastewater treated

Costa, Danniely de Oliveira 28 August 2014 (has links)
Made available in DSpace on 2016-08-16T13:31:37Z (GMT). No. of bitstreams: 1 DannielyOC_DISSERT.pdf: 2303659 bytes, checksum: 0a8a4e23e67c6b7ec7713ce05f41d2e4 (MD5) Previous issue date: 2014-08-28 / Water scarcity and environmental degradation in semiarid region are factors that increase the use of treated domestic wastewater aiming its agricultural use. The drip irrigation becomes more sustainable method for this purpose, due to high application efficiency and low risk of contamination of agricultural produce and operators in the field. However, they have a high susceptibility of obstruction the emitters, particularly when operating with wastewaters, because of the biofouling's formation. In this context, the present study seeked to employ biological treatment aimed at the drippers' unblocking that operate with treated domestic wastewater. For that, we assembled an experimental bench in the Experimental Unit for Water Reuse (EUWR), which has a total area of 793.13 m2, installed on the Zoo and Botanical Park located at the Universidade Federal Rural do Semi-Árido (UFERSA), Mossoró campus. To assessment of hydraulic performance and clogging of three types of drippers applying wastewater treated for 400 h, was mounted an experiment with four irrigation units, equipped with three types of emitters (G1, G2 and G3), with three replicates (three lateral lines by type of dripper). Every 80 h of operation evaluated the CUC, CUD, Us, CVQ, RQR and Q. After the operation time of 400 h, was held the second experiment, characterized by the use of biological treatment that consisted of catalyst enzymatic brand Byosol Swift, line FA (Aseptic Fosse) and powder concentrate of bacteria MaxBio brand, used together . The experiment was mounted with three factors, being the first factor the three types of emitters, the second factor the three treatments T1 (without application of the product), T2 (first application of the product) and T3 (second application of the product) and the third factor the dosages DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) and DOS4 (320 mg L-1) the product MaxBio in three replicates (three lateral lines by type of dripper in each irrigation unit). The data were submitted to analysis of simple and multiple regression, mean test and parametric Pearson correlations test. The results indicated that the formation of biofouling resulting from the interaction between the physical, chemical and biological agents led to partial and total clogging of emitters and hence reduction in the hydraulic performance of irrigation units which operate with domestic wastewater treated. The dripper G1 was more susceptible to clogging than the drippers G2 and G3. In dripper G1, the dosage of 80 mg L-1 MaxBio showed more positive results, as the recovery of hydraulic performance, this being more expressive effect with the completion of the second application of the product. A dosage of 80 mg L-1 MaxBio also showed the best results in clearing the dripper G3, the first application of the product is required, only / A escassez hídrica e a degradação ambiental no semiárido são fatores que potencializam a utilização de águas residuárias domésticas tratadas visando seu aproveitamento agrícola. A irrigação localizada torna-se o método mais sustentável para este fim, devido à elevada eficiência de aplicação e do baixo risco de contaminação do produto agrícola e de operadores no campo. No entanto, apresentam alta susceptibilidade ao entupimento de emissores, particularmente quando operam com águas residuárias, em função da formação de bioincrustação. Neste contexto, o presente trabalho teve por objetivo empregar o tratamento biológico visando à desobstrução de gotejadores que operam com água residuária doméstica tratada. Para isso, foi montada uma bancada experimental na Unidade Experimental de Reuso de Água (UERA), a qual apresenta uma área total de 793,13 m2, instalada no Parque Zoobotânico da Universidade Federal Rural do Semi-Árido (UFERSA), campus Mossoró. Para avaliação do desempenho hidráulico e do entupimento dos três tipos de gotejadores aplicando água residuária tratada, durante 400 h, montou-se um experimento com quatro unidades de irrigação, dotadas de três tipos de gotejadores (G1, G2 e G3), em três repetições (três linhas laterais por tipo de gotejador). A cada 80 h de funcionamento avaliou-se o CUC, CUD, Us, CVQ, RQR e Q. Decorrido o tempo de operação de 400 h, realizou-se o segundo experimento, caracterizado pelo emprego do tratamento biológico que constou de catalisador enzimático da marca Byosol Swift, linha FA (Fossa Asséptica) e de pó concentrado de bactérias da marca MaxBio, utilizados conjuntamente. O experimento foi montado com três fatores, sendo o primeiro fator os três tipos de gotejadores, o segundo fator os três tratamentos T1 (sem aplicação do produto), T2 (1ª aplicação do produto) e T3 (2ª aplicação do produto) e o terceiro fator as dosagens DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) e DOS4 (320 mg L-1) do produto MaxBio, em três repetições (três linhas laterais por tipo de gotejador em cada unidade de irrigação). Os níveis de desobstrução dos gotejadores pelos produtos biológicos foram avaliados. Os dados foram submetidos às análises de regressão simples e múltipla, teste de média e teste de correlações paramétricas de Pearson. Os resultados indicaram que a formação de bioincrustação resultante da interação entre os agentes físico-químicos e biológicos propiciou o entupimento parcial e total dos gotejadores e, consequentemente, redução no desempenho hidráulico das unidades de irrigação que operaram com água residuária doméstica tratada. O gotejador G1 foi mais suscetível ao entupimento do que os gotejadores G2 e G3. No gotejador G1, a dosagem de 80 mg L-1 de MaxBio apresentou resultados mais positivos, quanto à recuperação do desempenho hidráulico, sendo este efeito mais expressivo com a realização da segunda aplicação do produto. A dosagem de 80 mg L-1 de MaxBio, também, apresentou os melhores resultados na desobstrução do gotejador G3, sendo necessária, apenas, a primeira aplicação do produto
58

Impactos socioambientais e desempenho da fossa verde no Assentamento 25 de Maio, Madalena (Ceará) / Environmental impacts and performance of the green sewage modules technology in "25 de Maio" land reform Settlement, Madalena (Ceará)

Coelho, Christine Farias January 2013 (has links)
COELHO, Christine Farias. Impactos socioambientais e desempenho da fossa verde no Assentamento 25 de Maio, Madalena (Ceará). 2013. 112 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Pró-Reitoria de Pesquisa e Pós-Graduação, Programa Regional de Pós-Graduação em Desenvolvimento e Meio Ambiente, Fortaleza-CE, 2013. / Submitted by demia Maia (demiamlm@gmail.com) on 2016-04-27T13:04:29Z No. of bitstreams: 1 2013_dis_cfcoelho.pdf: 14910381 bytes, checksum: 9f97b15b1fcca455957c0a1ca782ed3a (MD5) / Approved for entry into archive by demia Maia (demiamlm@gmail.com) on 2016-04-27T13:05:56Z (GMT) No. of bitstreams: 1 2013_dis_cfcoelho.pdf: 14910381 bytes, checksum: 9f97b15b1fcca455957c0a1ca782ed3a (MD5) / Made available in DSpace on 2016-04-27T13:05:56Z (GMT). No. of bitstreams: 1 2013_dis_cfcoelho.pdf: 14910381 bytes, checksum: 9f97b15b1fcca455957c0a1ca782ed3a (MD5) Previous issue date: 2013 / The contamination of aquatic ecosystems through discharge of waste is one of the environmental impacts more often observed in the Brazilian Northeast semiarid environment, resulting in losses of the multiple uses of water and of collective health. The planned water reuse assumes a fundamental role in the sustainable management of water resources. This study aims to evaluate the performance and environmental impacts of the green sewage modules technology (GSM) implanted in "25 de Maio" land reform Settlement, (Madalena, Ceará). This social technology corresponds to an alternative model of treatment of household wastewater that considers water reuse in productive backyards, protection of natural resources and contributes to rural sanitation. The research adopted the case study of 58 GSM that were constructed using a participative approach. The level of satisfaction and ownership of technology was achieved through the combined technique of participant observation and interviews conducted from September 2011 to September 2012. The GSM were monitored at the same time the interviews were carried out and the following assessment criteria: degree of use, cultivation and plant diversity, placement of seedlings, seedling size and quantity, occurrence of overflow, reflux, obstruction, odour and conducting maintenance. Regarding the level of satisfaction, it is noted that contentment with GSM is most visible where the banana trees produce fruits and at situations of satisfactory performance of the system. Water scarcity affected the performance of some GSM due to the lower contribution of effluent coming from domestic water consumption. Overall the use of productive backyards associated with ecological sanitation strengthens family farms and appreciates the local culture also promotes environmental health. The assessment quality of GSM substrate was based on microbiological (SMB-C, SBR and qCO2) and chemical (pH, P, OM, EC) parameters analyzed in samples from five beds chosen under different managements systems. The results showed that systems with higher metabolic activity are those where we observe the best scenarios for crops development. The satisfactory development of crops, including production of fruits (papaya, banana, peppers and tomatoes) may be associated with the cultivation of multiple species on beds, suggesting an array of crops that best fits the levels phosphorus,nitrogen, and especially content salinity, found in substrates collected. Representative samples of tomato (Solanum esculentum), pepper (Capsicum chinense), banana (Musa sp.) and malvarisco leaves (Plectranthus amboinicus L.) were subjected to analysis of sanitary quality, and the results indicated that they are fully able to consumption. The GSM design parameters were calculated using the mass balance of water that include estimate of per capita consumption of water, sewage contribution and coefficient of return (r) in two different situations: household with piped water and house devoid of piped water. In order to estimate the consumptive use of GSM, it was used a control bed cultivated with banana (Musa spp.), in which the rate of crop evapotranspiration (Etc), verified by the methods Class A pan and Penman-Monteith, showed a water consumption 5,1 mm.day-1. The satisfactory design of GSM for the use most efficient of water effluent from domestic sewage is 30 m² for households with piped water and 2 m² for households devoid of piped water. It emphasizes the perspective of public policy formulation sanitation for rural land reform projects with a view to healthy housing and the promotion of health. / A contaminação dos ecossistemas aquáticos através do lançamento de resíduos sólidos e líquidos constitui um dos impactos ambientais mais observados no semiárido nordestino, implicando em prejuízos aos usos múltiplos da água e na saúde coletiva. Portanto, o reuso planejado de água assume papel fundamental na gestão sustentável dos recursos hídricos. O presente trabalho tem por objetivo avaliar o desempenho e as repercussões socioambientais do Módulo Fossa Verde (MFV, ou canteiro biosséptico) implantado no Assentamento 25 de Maio (A25M, Madalena, Ceará). Essa tecnologia social corresponde a um modelo alternativo de tratamento de efluente domiciliar que considera o reuso da água em quintais produtivos, a proteção dos recursos naturais e contribui para o saneamento rural. A pesquisa adota como estudo de caso 58 fossas verdes construídas de modo participativo em residências e equipamentos sociais no A25M. O nível de satisfação e apropriação da tecnologia foi obtido por meio da técnica combinada de entrevista e observação participante realizadas no período de Set./2011 a Set./2012. Os canteiros foram monitorados na mesma ocasião das entrevistas e foram considerados os seguintes critérios avaliativos: grau de utilização, cultivo e diversidade de planta, posicionamento das mudas, porte e quantidade das mudas, ocorrência de extravasamento, refluxo, entupimento, odor e realização da manutenção. Em relação ao nível de satisfação, percebe-se que o contentamento dos beneficiários com o MFV é mais visível nos casos em que as bananeiras frutificaram e nas situações de desempenho satisfatório do sistema. A escassez hídrica interferiu no desempenho de alguns canteiros em decorrência do menor aporte de efluente provindo do consumo de água doméstico. E de modo geral, a utilização dos quintais produtivos associados ao saneamento ecológico fortalece a agricultura familiar e valoriza a cultura local, além disso, promove a saúde ambiental. A avaliação da qualidade do substrato foi baseada em parâmetros microbiológicos (C-BMS, RBS e qCO2) e químicos (pH, P, MO, CE) analisados em amostras de canteiros biossépticos sob diferenciados sistemas gerenciamentos. Os resultados apontaram que os sistemas com maiores índices de atividade metabólica são aqueles onde se observam os melhores cenários de desenvolvimento vegetal. O desenvolvimento satisfatório das culturas, inclusive com fornecimento de frutos (mamão, banana, pimentão, tomate) pode estar associado ao cultivo múltiplo de espécies no canteiro, sugerindo um arranjo de culturas que melhor se adeque aos níveis fósforo, nitrogênio e, sobretudo, teor de salinidade, encontrados nos substratos coletados. Amostras representativas de tomate (Solanum esculentum), pimenta (Capsicum chinense), banana (Musa sp.) e folha de malvarisco (Plectranthus amboinicus L.) foram submetidas à análise de qualidade sanitária e os resultados indicaram que os mesmos são plenamente aptos para o consumo. Os parâmetros de dimensionamento do sistema foram calculados através do balanço de massa hídrica e incluem a estimativa do consumo per capita de água, contribuição de esgoto e coeficiente de retorno (r) em duas situações distintas: casa interligada à rede de abastecimento de água e casa desprovida de água encanada. Para estimativa do uso consuntivo do MFV foi utilizado um canteiro controle com cultivo de banana (Musa spp.), em que a taxa de evapotranspiração da cultura (Etc), verificada pelos métodos Tanque Classe A e Penman-Monteith, apresentou 5,1mm.dia-1 para o consumo hídrico. O dimensionamento satisfatório para o aproveitamento mais eficiente da água provinda do esgoto doméstico é de 30 m² para casas com água canalizada e de 2m² para casas desprovidas de abastecimento de água em rede. Enfatiza-se a perspectiva de formulação de políticas públicas de saneamento rural para projetos de reforma agrária com vistas à habitação saudável e à promoção da saúde coletiva.
59

Estudo comparativo da qualidade da água de chuva coletada em cobertura convencional e em telhado verde

Budel, Marcel Aramis 31 March 2014 (has links)
CAPES / O estudo consiste em uma comparação da qualidade da água da chuva coletada em duas formas distintas de captação: um sistema composto por um telhado inclinado com telhas de concreto, nomeada (casa 1) e o outro composto por uma cobertura plana com telhado verde, ou seja, vegetado, nomeada (casa 2). Tem por objetivo caracterizar os sistemas utilizados nas duas formas de cobertura, analisar a qualidade da água da chuva captada nos dois sistemas e fazer o acompanhamento da qualidade da água armazenada para posterior uso ao longo do estudo com o intuito de verificar a eficiência e comportamento dos sistemas de captação. Objetiva ainda encontrar relações nas variáveis envolvidas e apresentar os resultados de forma a estabelecer uma comparação qualitativa no desempenho das duas coberturas. O estudo foi realizado em duas casas localizadas na região noroeste da cidade de Curitiba, capital do Paraná. Na casa 1, com telhas de concreto, a água da chuva que escoa pelo telhado é primeiramente coletada por uma calha, seguindo por um duto vertical até o nível do solo, no qual se encontra um filtro simples, então a água é encaminhada para uma cisterna, onde é armazenada, para posterior uso na torneira externa para onde a água é bombeada. Já na casa 2, com cobertura plana vegetada, a água da chuva após passar pelo telhado verde é conduzida por dutos verticais até a cisterna de concreto no nível do solo, então uma eletrobomba recalca a água até um reservatório localizado na cobertura, acima do nível do telhado verde, para armazenamento e posterior uso na torneira externa. As amostras coletadas em nove eventos (17/05/2013 a 03/12/2013) foram analisadas quanto à: pH, turbidez, oxigênio dissolvido e temperatura, que foram medidos no próprio local. Demanda química de oxigênio (DQO), amônia, nitrito, nitrato e fosfato foram amostrados e analisados no laboratório de Saneamento da UTFPR, Campus Ecoville. Ainda quanto à presença de coliformes totais e termotolerantes (E. Coli), foram realizados em um laboratório terceirizado. Observou-se que o telhado convencional da casa 1 apresentou maior qualidade no parâmetro turbidez e demanda química de oxigênio (DQO), já o telhado verde diminuiu a acidez natural da água da chuva. As duas coberturas se mostraram eficientes pela concentração de amônia e nitrato, contudo indicaram concentrações elevadas de fosfato. Nos parâmetros microbiológicos os dois telhados não obtiveram qualidade suficiente para atender a NBR 15.527/2007. Desta forma, tomadas as devidas precauções, se recomenda o uso da água proveniente dos telhados, vegetados e convencional, para descargas de bacias sanitárias, irrigação de gramados e plantas ornamentais, lavagem de veículos, limpeza de calçadas e ruas, limpeza de pátios, espelhos d'água e usos industriais, conforme estabelecido na norma. / The study consists of a comparison of the quality of rainwater collected in two distinct ways of catchments: a system composed of a pitched roof with concrete tiles and another consisted of a vegetated flat coverage, as known as green roof. It aims to characterize the systems used in both forms of coverage, to analyze the quality of rainwater captured in the two systems and to monitor the quality of water stored for later use throughout the study in order to verify the efficiency and performance of catchment systems. It also aims to find relations in the involved variables and to present the results in order to establish a qualitative comparison in the performance of two coverages. The study was conducted in two houses located in the northwest region of the city of Curitiba, capital of Paraná. The appointee, house 1, has a pitched roof with concrete tiles, the rainwater that seeps through the roof is first collected by a trough, followed by a vertical duct to the ground level, with a simple filter, then the water is sent into a tank where it is stored for later use in the external faucet where the water is pumped. However, at house 2, with vegetated flat roof, after passing through the green roof the rainwater is driven by vertical ducts to the concrete tank at ground level, then an electric pump represses the water to a reservoir located on the roof, above the green roof ́s level for storage and later use on the external tap. Samples collected in nine events (17/05/2013 to 03/12/2013) were analyzed for pH, turbidity, dissolved oxygen and temperature, they were measured in situ. Chemical oxygen demand (COD), ammonia, nitrite, nitrate and phosphate were sampled and analyzed in the laboratory of Sanitation UTFPR Campus Ecoville. Nevertheless, for the presence of total and fecal coliforms (E. coli), tests were performed on an outsourced laboratory. As for the results obtained, the conventional roof house 1 rainwater had higher quality in turbidity and chemical oxygen demand (COD) parameter, whereas in house 2 the green roof reduced the natural acidity of rainwater. The two covers were effective in the concentration of ammonia and nitrate, though indicated high concentrations of phosphate. Microbiological parameters in neither roofs met the NBR 15.527/2007 quality. Thus, taken due precautions, it is recommend the use of water from roofs, vegetated and conventional, to flush toilets, to irrigate lawns and ornamental plants, to wash vehicles, to clean sidewalks and streets, to clean patios, water mirrors and to industrial uses, as defined in the standards.
60

Estudo comparativo da qualidade da água de chuva coletada em cobertura convencional e em telhado verde

Budel, Marcel Aramis 31 March 2014 (has links)
CAPES / O estudo consiste em uma comparação da qualidade da água da chuva coletada em duas formas distintas de captação: um sistema composto por um telhado inclinado com telhas de concreto, nomeada (casa 1) e o outro composto por uma cobertura plana com telhado verde, ou seja, vegetado, nomeada (casa 2). Tem por objetivo caracterizar os sistemas utilizados nas duas formas de cobertura, analisar a qualidade da água da chuva captada nos dois sistemas e fazer o acompanhamento da qualidade da água armazenada para posterior uso ao longo do estudo com o intuito de verificar a eficiência e comportamento dos sistemas de captação. Objetiva ainda encontrar relações nas variáveis envolvidas e apresentar os resultados de forma a estabelecer uma comparação qualitativa no desempenho das duas coberturas. O estudo foi realizado em duas casas localizadas na região noroeste da cidade de Curitiba, capital do Paraná. Na casa 1, com telhas de concreto, a água da chuva que escoa pelo telhado é primeiramente coletada por uma calha, seguindo por um duto vertical até o nível do solo, no qual se encontra um filtro simples, então a água é encaminhada para uma cisterna, onde é armazenada, para posterior uso na torneira externa para onde a água é bombeada. Já na casa 2, com cobertura plana vegetada, a água da chuva após passar pelo telhado verde é conduzida por dutos verticais até a cisterna de concreto no nível do solo, então uma eletrobomba recalca a água até um reservatório localizado na cobertura, acima do nível do telhado verde, para armazenamento e posterior uso na torneira externa. As amostras coletadas em nove eventos (17/05/2013 a 03/12/2013) foram analisadas quanto à: pH, turbidez, oxigênio dissolvido e temperatura, que foram medidos no próprio local. Demanda química de oxigênio (DQO), amônia, nitrito, nitrato e fosfato foram amostrados e analisados no laboratório de Saneamento da UTFPR, Campus Ecoville. Ainda quanto à presença de coliformes totais e termotolerantes (E. Coli), foram realizados em um laboratório terceirizado. Observou-se que o telhado convencional da casa 1 apresentou maior qualidade no parâmetro turbidez e demanda química de oxigênio (DQO), já o telhado verde diminuiu a acidez natural da água da chuva. As duas coberturas se mostraram eficientes pela concentração de amônia e nitrato, contudo indicaram concentrações elevadas de fosfato. Nos parâmetros microbiológicos os dois telhados não obtiveram qualidade suficiente para atender a NBR 15.527/2007. Desta forma, tomadas as devidas precauções, se recomenda o uso da água proveniente dos telhados, vegetados e convencional, para descargas de bacias sanitárias, irrigação de gramados e plantas ornamentais, lavagem de veículos, limpeza de calçadas e ruas, limpeza de pátios, espelhos d'água e usos industriais, conforme estabelecido na norma. / The study consists of a comparison of the quality of rainwater collected in two distinct ways of catchments: a system composed of a pitched roof with concrete tiles and another consisted of a vegetated flat coverage, as known as green roof. It aims to characterize the systems used in both forms of coverage, to analyze the quality of rainwater captured in the two systems and to monitor the quality of water stored for later use throughout the study in order to verify the efficiency and performance of catchment systems. It also aims to find relations in the involved variables and to present the results in order to establish a qualitative comparison in the performance of two coverages. The study was conducted in two houses located in the northwest region of the city of Curitiba, capital of Paraná. The appointee, house 1, has a pitched roof with concrete tiles, the rainwater that seeps through the roof is first collected by a trough, followed by a vertical duct to the ground level, with a simple filter, then the water is sent into a tank where it is stored for later use in the external faucet where the water is pumped. However, at house 2, with vegetated flat roof, after passing through the green roof the rainwater is driven by vertical ducts to the concrete tank at ground level, then an electric pump represses the water to a reservoir located on the roof, above the green roof ́s level for storage and later use on the external tap. Samples collected in nine events (17/05/2013 to 03/12/2013) were analyzed for pH, turbidity, dissolved oxygen and temperature, they were measured in situ. Chemical oxygen demand (COD), ammonia, nitrite, nitrate and phosphate were sampled and analyzed in the laboratory of Sanitation UTFPR Campus Ecoville. Nevertheless, for the presence of total and fecal coliforms (E. coli), tests were performed on an outsourced laboratory. As for the results obtained, the conventional roof house 1 rainwater had higher quality in turbidity and chemical oxygen demand (COD) parameter, whereas in house 2 the green roof reduced the natural acidity of rainwater. The two covers were effective in the concentration of ammonia and nitrate, though indicated high concentrations of phosphate. Microbiological parameters in neither roofs met the NBR 15.527/2007 quality. Thus, taken due precautions, it is recommend the use of water from roofs, vegetated and conventional, to flush toilets, to irrigate lawns and ornamental plants, to wash vehicles, to clean sidewalks and streets, to clean patios, water mirrors and to industrial uses, as defined in the standards.

Page generated in 0.0551 seconds