• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • Tagged with
  • 643
  • 643
  • 342
  • 221
  • 167
  • 144
  • 127
  • 107
  • 92
  • 84
  • 80
  • 77
  • 76
  • 67
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo integrado para transporte, tratamento, valorização e destino final das lamas produzidas na ETAR de Sobreiras, na ETAR do Feixo

Carvalho, Ana Carolina Pinto Teixeira January 2010 (has links)
Estágio realizado na empresa Águas do Porto EM e orientado pelo Prof. Doutor Joaquim Manuel Veloso Poças / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2010
52

Diagnóstico e optimização do tratamento de águas residuais em leitos de macrófitas

Oliveira, João Miguel da Silva Campos January 2007 (has links)
Tese de mestrado. Engenharia do Ambiente. 2007. Faculdade de Engenharia. Universidade do Porto
53

Contribuições para um uso mais eficiente da água no ciclo urbano : poupança de água e reutilização de águas cinzentas

Rossa, Sara Rita Louro Guerreiro Serrasqueiro January 2006 (has links)
Tese de mestrado. Engenharia do Ambiente. 2006. Faculdade de Engenharia. Universidade do Porto
54

Avaliação da ecotoxicidade de águas superficiais : aplicação à bacia hidrográfica do Rio Leça

Gomes, Ana Isabel de Emílio January 2007 (has links)
Tese de Mestrado. Mestrado em Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2007
55

Descarga de águas residuais não domésticas em sistemas de drenagem urbanos : avaliação do impacto nas redes e nos meios hídricos receptores

Moura, Elisabete Maria de Jesus January 2009 (has links)
Tese de mestrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2009
56

Avaliação do potencial para reutilização dos efluentes tratados nas ETAR do Concelho de Valongo

Pinto, João Filipe Machado January 2009 (has links)
Estágio realizado nas Águas de Valongo, S.A. e orientado pelo Doutora Paula Moreira Figueiredo / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2009
57

Synthesis, spectroscopy and characterization of titanium dioxide based photocatalysts for the degradative oxidation of organic pollutants

Silva, Cláudia Sofia Castro Gomes da January 2008 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 208
58

Catalytic ozonation of effluents from the textile industry

Faria, Patrícia Celeste Curval January 2008 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 2008
59

Desenvolvimento de um sistema de filtragem para tratamento de água cinza visando o seu reúso / Development of a filtration system for treatment of greywater aimed its reuse

Santana, Eduardo de Aragão 22 July 2013 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-30T17:36:09Z No. of bitstreams: 1 texto completo.pdf: 1782067 bytes, checksum: 0c58b1b62d626d174870c6effe1ca3c6 (MD5) / Made available in DSpace on 2017-05-30T17:36:09Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1782067 bytes, checksum: 0c58b1b62d626d174870c6effe1ca3c6 (MD5) Previous issue date: 2013-07-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A escassez hídrica é um problema considerado mundial, tanto no aspecto quantitativo como no qualitativo. Sendo assim, o reúso da água cinza pode ser uma alternativa importante no combate à citada escassez de água. Tal estratégia pode ser considerada interessante, pois, muitas vezes, as pessoas usam a água potável para fins que não necessitam de tal qualidade, como é o caso da irrigação de jardins, lavagem de carros e descarga de vasos sanitários. Assim, objetivou-se, com essa pesquisa, desenvolver um sistema modular de filtros de baixo custo, eficiente e de fácil operação, que proporcionasse o tratamento e o possível reaproveitamento da água cinza em ambientes domésticos. A água cinza de uma residência rural foi tratada por um sistema de filtração sequencial formada por dois filtros, um com serragem de madeira (FSM) e o outro com carvão ativado (FCA). Espessuras de camada de 40, 60 e 80 cm foram testadas para os FSM, e de 10, 20 e 30 cm para FCA, bem como a combinação dos FSM com os FCA. Parâmetros físicos, químicos e microbiológicos foram analisados para quantificar o desempenho dos filtros. Os FSM apresentaram bom desempenho na remoção de sólidos e turbidez, sendo o FSM 80 o mais eficiente. Os FCA foram essenciais na remoção dos compostos pouco removidos pelos FSM, como foi o caso da DQO, DBO, surfactantes e E. coli. No geral, o conjunto de melhor desempenho na remoção de poluentes foi o FSM 80 com FCA 30. Apesar dos bons valores de eficiência obtidos pelos filtros, a qualidade final da água cinza tratada não atendeu a todos os critérios de reúso exigidos por alguns órgãos regulamentadores. Porém, seria possível reutilizá-la para irrigação irrestrita, segundo a OMS. Por outro lado, etapas adicionais de tratamento devem ser implementadas, a fim de obter-se água cinza de melhor qualidade para outros usos. / Water scarcity is considered a global problem, as the quantitative as the qualitative aspect. Therefore, the reuse of gray water can be an important alternative to combat shortages of water. This strategy can be considered interesting because often people use drinking water for purposes that do not require such high quality, as is the case for watering gardens, washing cars and toilet flushing. Thus, the objective of this research was to develop a modular filters with: low cost, efficient and easy operation, which would provide treatment and reuse of gray water for domestic use. The gray water from a rural residence was treated by a filtration system consisting of two filters sequentially, one with sawdust (FSM) and another with activated carbon material (FCA). Thickness layer of 40, 60 and 80 cm were tested for FSM, and 10, 20 and 30 cm, for activated carbon, as well as the combination of the FSM and the FCA. Physical, chemical and microbiological parameters were analyzed to quantify the performance of the filters. The FSM had good performance in the removal of solids and turbidity, and the FSM 80 was the most efficient. The FCA were essential in the removal of compounds that had lower removal efficiency by FSM, as it was the case for COD, BOD, surfactant and E. coli. In general, the range of best performance in removing pollutants was FSM 80 with FCA 30. Despite the good performance figures obtained by the filters, the final quality of treated gray water did not meet all the criteria required for reuse by some regulatory organizations. However, it would be possible to reuse it for unrestricted irrigation, according to WHO. On the other hand, additional processing steps must be implemented in order to obtain better quality gray water for other uses. / Não foi encontrado o cfp do autor, não tinha ficha de publicação, somente email autorizando a publicar.
60

Avaliação de desreguladores endócrinos e do micropoluente colesterol em estações de tratamento de esgoto sanitário / Endocrine disruptors. Effluent treatment station. Gas chromatography. Ecotoxicity. Emerging micropollutants

Pessoa, Germana de Paiva 23 November 2012 (has links)
PESSOA, G. P. Avaliação de desreguladores endócrinos e do micropoluente colesterol em estações de tratamento de esgoto sanitário. 2012. 213 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2013-06-24T14:16:57Z No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-06-28T17:31:36Z (GMT) No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) / Made available in DSpace on 2013-06-28T17:31:36Z (GMT). No. of bitstreams: 1 2012_tese_gppessoa.pdf: 5376587 bytes, checksum: edc9dcc0e4fb6b981d7d2ec0061fa5df (MD5) Previous issue date: 2012-11-23 / Endocrine disruptors chemicals (EDCs), whose presence in sewage is mainly attributed to the natural hormones 17 -estradiol (E2) and estrone (E1) and to the synthetic one 17-ethinylestradiol (EE2), the main active ingredient of oral contraceptives, can cause a series of disturbances in the reproductive organs of humans and animals, since such compounds are not readily removed by biological processes of conventional treatment, being improperly released into water bodies. However, the above mentioned compounds are found at low concentrations (ng L -1/μg L -1) in aqueous environmental matrices, which make their detection and quantification an analytical challenge. Thus, an analytical methodology using gas chromatography coupled to mass spectrometry (GC/MS) was developed and optimized in order to evaluate the removal efficiency of EDs and the micropollutant cholesterol (CHOL) in wastewater treatment plants (WWTPs) from the Metropolitan Area of Fortaleza, as well as to detect them in surface waters. Acute and chronic ecotoxicity tests with effluents and EDs using the microcrustacean Daphnia magna as bioindicator. Five WWTPs were evaluated, which were divided in four types of technologies, namely: two WWTPs with facultative pond followed by maturation pond (FP+MP1 and FP+MP2), facultative pond (FP), activated sludge followed by chlorination step (AS+Cl) and upflow anaerobic sludge blanket reactor followed by chlorination step (UASB+Cl). The mean concentrations for micropollutants in effluents were: 557.4 ng.L-1 (E1), 144.4 ng.L-1 (E2), 266.4 ng.L-1 (E2-17A), 421.4 ng.L-1 (EE2) and 4691.9 ng.L-1 (CHOL). The maximum values obtained in surface water were: 212.75 ng.L-1 (E1), 256.25 ng.L-1 (E2) and 1175 ng.L-1 (CHOL). The estrogens E2-17A and EE2 were not detected. Regarding the EDs removal, the lowest removal efficiencies were found for low-rate systems (stabilization ponds) with 68.1% (FP+MP1), 79.9% (FP+MP2) and 54.0% (FP). The high-rate systems obtained satisfactory removal efficiency: 93.4% (LA+Cl), 95.4% (UASB+Cl). For CHOL, the best removal was obtained by the WWTP FP+MP2 with 94%, followed by the WWTPs AS+Cl (88%) and UASB+Cl (82%). No toxicity was detected in the effluent from the WWTP FP+MP2, however, in the effluents from FP+MP1 and FP, maximum EC50-48h was 61% and 57%, respectively. The toxicity level in the effluents from WWTPs UASB and AS was higher than that obtained in the influents. Probably, the toxicity increase was due to the presence of residual chlorine in the effluent since it was collected after the chlorination step. Concerning the chronic toxicity, significant effect in terms of reproduction (p <0.05) was detected only in the effluent from the WWTP FP+MP2 with NOEC (no observed effect concentration) of 20% and OEC (observed effect concentration) of 30%. In the effluents from the WWTPs AS+Cl and UASB+Cl, the OEC value for survival evaluation was 5%, evidencing the high toxicity. In the assay with a multielement estrogens solution, the survival chronic effect was not observed. However, there was a chronic effect in terms of sex change, showing values of NOEC and OEC of 2 and 4 μg.L-1, respectively. In terms of reproduction, NOEC was 4 μg.L-1 and CEO of 1 μg.L-1. Based on these results, it can be concluded that there is a need for optimization of WWTPs operational parameters in order to improve micropollutants removal efficiency. / Os desreguladores endócrinos (DEs), cuja presença em esgotos sanitários deve-se principalmente aos hormônios naturais 17 β-estradiol (E2) e estrona (E1) e ao sintético 17α-etinilestradiol (EE2), principal substância ativa do contraceptivo oral, podem causar uma série de distúrbios nos órgãos reprodutores dos seres humanos e animais, haja vista que tais compostos não são prontamente removidos por processos biológicos de tratamento convencionais, sendo lançados de forma inadequada em corpos d’água. No entanto, os compostos supramencionados se encontram em baixas concentrações (ng.L-1/μg.L -1) em matrizes ambientais aquosas, tornando sua detecção e quantificação um desafio analítico. Deste modo, buscou-se desenvolver e otimizar uma metodologia analítica utilizando a técnica de cromatografia gasosa acoplada a espectrometria de massas (CG/MS) com o objetivo de avaliar a eficiência de remoção dos DEs e do micropoluente colesterol (CHOL) em Estações de Tratamento de Esgotos (ETEs) da Região Metropolitana de Fortaleza, assim como detectá-los em águas superficiais. Foram realizados ensaios de ecotoxicidade aguda e crônica com os efluentes e DEs, utilizando o microcrustáceo Daphnia magna como bioindicador. Foram avaliadas cinco ETEs, sendo quatro tipos de tecnologias, a saber: duas ETEs com lagoa facultativa seguida de lagoa de maturação (LF+LM1 e LF+LM2), lagoa facultativa (LF), lodos ativados seguido da etapa de cloração (LA+Cl) e reator de manta de lodo e fluxo ascendente seguido da etapa de cloração (UASB+Cl). As concentrações médias para os micropoluentes nos efluentes foram: 557,4 ng.L-1 (E1); 144,4 ng.L-1 (E2); 266,4 ng.L-1 (E2-17A); 421,4 ng.L-1 (EE2) e 4691,9 ng.L-1 (CHOL). Os valores máximos obtidos nas águas superficiais foram de: 212,75 ng.L-1 (E1); 256,25 ng.L-1 (E2) e 1175 ng.L-1 (CHOL). Os estrogênios E2-17A e EE2 não foram detectados. Com relação à remoção dos DEs, as menores eficiências de remoção foram encontradas para os sistemas de baixa taxa (lagoas de estabilização) com 68,1% (LF+LM1); 79,9% (LF+LM2) e 54,0% (LF). Os sistemas de alta taxa obtiveram eficiências de remoção satisfatórias: 93,4% (LA+Cl); 95,4% (UASB+Cl). Para o CHOL o melhor índice de remoção foi obtido na ETE LF+LM2 com 94%, seguida das ETEs LA+Cl (88%) e UASB+Cl (82%). Com relação à avaliação ecotoxicológica aguda, não foi detectada toxicidade no efluente proveniente da ETE LF+LM2, entretanto, nos efluentes da LF+LM1 e LF, a CE50-48h máxima foi de 61% e 57%, respectivamente. O nível de toxicidade nos efluentes das ETE LA+Cl e UASB+Cl foi maior que o obtido nos afluentes. Provavelmente, o aumento de toxicidade deve-se à presença de cloro residual no efluente, uma vez que este era coletado após a etapa de cloração. Tratando-se de toxicidade crônica, foi detectado efeito significativo em termos de reprodução (p < 0,05) apenas no efluente proveniente da ETE LF+LM2 com CENO (concentração de efeito não observado) de 20% e CEO (concentração de efeito observado) de 30%. Nos efluentes provenientes das ETE LA+Cl e UASB+Cl, o valor de CEO para a avaliação de sobrevivência foi de 5%, evidenciando a elevada toxicidade. No ensaio realizado com a solução multielementar de estrogênios, o efeito crônico de sobrevivência não foi observado, no entanto foi observado um efeito crônico em termos de mudança de sexo, apresentando valores de CENO e CEO de 2 e 4 μg.L-1, respectivamente. Em termos de reprodução, o CENO foi de 4 μg.L-1 e o CEO de 1 μg.L-1. Diante dos resultados obtidos, pode-se concluir que existe uma necessidade de otimização dos parâmetros operacionais das ETEs com o objetivo de melhorar a eficiência de remoção de micropoluentes.

Page generated in 0.2946 seconds