• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigation des corrélations existant entre la perception de qualité audio et les réactions physiologiques d'un auditeur

Baudot, Matthias January 2010 (has links)
Les tests d'écoute subjectifs permettent d'évaluer la fiabilité de reproduction des systèmes de codage audio (codecs). Le projet présenté ici vise à évaluer la possibilité d'utiliser les réactions physiologiques (activité électrodermale, cardiaque, musculaire et cérébrale) à la place d'une note donnée par l'auditeur, afin de caractériser la performance d'un codec. Ceci permettrait d'avoir une méthode d'évaluation plus proche de la perception réelle de qualité audio du sujet. Des tests d'écoute mettant en oeuvre des dégradations audio bien connues en concours avec la mesure des réactions physiologiques ont été réalisés pour 4 auditeurs. L'analyse des résultats montre que certaines caractéristiques physiologiques permettent d'avoir une information fiable sur la qualité audio perçue, et ce de manière répétable pour près de 70% des signaux audio testés chez un sujet, et près de 60% des séquences audio testées chez tous les sujets. Ceci permet de postuler sur la faisabilité d'une telle méthode d'évaluation subjective des codecs audio.
2

Nouvelle modalité de contrôle en boucle fermée de l'activation musculaire et prédiction en ligne du couple musculaire sous SEF / Real-time EMG-Feedback Torque Prediction and Muscle Activation Control toward New Modality in FES

Li, Zhan 08 December 2014 (has links)
La stimulation électrique fonctionnelle (SEF) est une des techniques utilisées pour la rééducation ou la suppléance fonctionnelle de déficiences motrices. Un stimulateur génère des impulsions électriques qui induisent des contractions des muscles paralysés, au travers des unités motrices toujours intactes. Aujourd'hui, les systèmes fonctionnant en boucle ouverte sont majoritairement utilisés. Ils permettent aux chercheurs d'évaluer hors-ligne de la SEF. Cependant, leur réglage reste basé sur un cycle essai-erreur ce qui est loin de simplifier la mise en œuvre de systèmes en boucle fermée. Dans cette thèse, nous proposons une méthode de prédiction en temps-réel du couple en fonction de l'EMG conduisant à une nouvelle modalité de contrôle de l'activation musculaire sous SEF. L'EMG évoquée (eEMG) donne une image de l'effet de la SEF sur l'activité musculaire et est ainsi impliquée à la fois dans l'estimation du couple en temps réel et le contrôle. Le couple articulaire peut être estimé par l'eEMG en utilisant un filtre de Kalman et un modèle NARX - RNN. Le facteur d'oubli du filtre de Kalman doit être soigneuse-ment choisi de même que les réglages du schéma de calcul. C'est une limitation en particulier quand lorsque qu'il n'y a aucune connaissance a priori sur la force générée par le sujet sous SEF. La méthode proposée NARX-RNN n'a pas ce défaut et offre de meilleures performances que le filtre de Kalman. L'estimation du couple basée eEMG est donc utilisée hors-ligne et en-ligne en temps réel. Les performances comparées des algorithmes ont été effectues sur sujets sains et sujets blessés médullaires. Par ailleurs, le système temps-réel de contrôle de l'activation musculaire basé EMG a été développé sur la technologie sans fil Vivaltis. Enfin, afin de proposer un contrôle de plusieurs muscles, le concept de synergie a été utilisée pour estimer les activations musculaires cibles à partir d'un couple articulaire désiré. Les niveaux de synergie moyenne ont été utilisés pour valider l'extraction d'activation sur le sujet non inclus dans le calcul de la moyenne. L'erreur d'estimation est de 9.3% sur l'ensemble des sujets. Ces résultats vont dans le sens d'un contrôle d'une neuroprothèse basé synergie. En effet la combinaison des eux contributions de la thèse ouvre des perspectives nouvelles de modalité de contrôle de la SEF. / Functional electrical stimulation (FES) is one of existing rehabilitationtechniques to restore lost motor functions for motor-impaired subjects. Thestimulator generates electrical pulses to drive artificial contractions of theparalysed muscles, through activating intact motor units. Currently open-loopFES system is the most frequently used. The data acquired from the open-loop FESwould help researchers to make off-line analysis for evaluating performance ofFES systems. However, it should go through a trial and error manner, which isfar from facilitating a implementation of real-time closed-loop FES system.In this thesis, we propose and develop a method for real-time EMG-feedback torqueprediction and muscle activation control toward new modality in FES.The evoked electromyography (eEMG) which can reflect electrical muscleactivities under FES, is involved in both offline and real-time FES-inducedtorque estimation and muscle control systems. FES-induced joint torque can beestimated/predicted with eEMG by employing both Kalman filter and NonlinearAuto-Regressive with Exogenous (NARX) type recurrent neural network (RNN). Theforgetting factor of Kalman filter should be properly selected in advance andalso with proper computational settings. It is a limitation for some casesespecially when we do not have prior knowledge of new subject regarding expectedmuscle response intensity induced by FES. The proposed NARX-RNN does not sufferfrom such computational setting problems and also shows better estimation/prediction performances than that of Kalman filter.Evoked EMG based torque estimator is exploited from off-line situation toonline real-time system. Recursive Kalman filter and NARX-RNN are implementedfor real-time torque estimation/prediction with evoked EMG. The performance wasverified both in able-bodied and spinal cord injured subjects. Furthermore, real-time EMG-feedback muscle activation control in FES system is developed togetherwith wireless Vivaltis stimulator for specifying directly muscle activationinstead of conventionally specifying stimulation pattern.Toward natural multiple muscles control with multi-channel FES, muscle synergyconcept was introduced for inverse estimation of muscle activations from desiredjoint moment. The averaged synergy ratio was applied for muscle activationestimation with leave-one-out cross validation manner, which resulted in 9.3%estimation error over all the subjects. This result supports the common musclesynergy-based neuroprosthetics control concept. By combining this inverse estimation of muscle activations together with real-time EMG-feedback muscle activation control, it would open a new modality toward muscle synergy-basedmulti-muscle activation control in FES.
3

Contribution à la conception d'un électromyostimulateur intelligent / Contribution to the design of a smart electromyostimulator

Yochum, Maxime 06 May 2013 (has links)
Cette thèse a pour but de mettre au point un nouvel outil de rééducation neuromusculaire. Elle a pour fonction, l'amélioration de la qualité et de la durée des séances de renforcement musculaire et de réentraînement de la motricité de sujets atteints de déconditionnement musculaire. Un électromyostimulateur "intelligent" utilisant en même temps des techniques d'électromyostimulation (EMS) couplées aux analyses de l'électromyogramme (EMG) est développé et permet d'asservir en temps réel les paramètres de stimulation d'un muscle en fonction de son état de fatigue physiologique. Le contrôle ainsi effectué sur les paramètres de stimulation en fonction de la réponse musculaire électrique (onde M) offre la possibilité de stimuler un muscle en prenant en compte une information sur la réaction du muscle à l'électrostimulation / This project aims to develop a new tool for neuromuscular reeducation. Its function is to improve the quality and the duration of muscular strengthening training sessions and training of motor function for patients suffering from muscle deconditioning. A "smart" electromyostimulator using, at the same time, techniques of electrostimulation (EMS) and analysis of electromyography (EMG) allows the control in real time electrical stimulation parameters considering the physiological fatigue of the stimulated muscle. This control, performed on stimulation parameters depending on electrical response of muscles (M wave), allows the muscle stimulation taking into account the muscular reaction to the electrical stimulation

Page generated in 0.0513 seconds