• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Chirurgie des troubles de la statique pelvienne et des hernies avec interposition de prothèses de renfort. / Surgery of pelvic disorders and hernias with interposition of reinforcement prostheses.

Nohuz, Erdogan 16 September 2013 (has links)
Introduction : L’allongement de l’espérance de vie, qui a pour corollaire le vieillissement de la population, laisse présager d’un recours croissant au renfort prothétique en chirurgie des troubles de la statique pelvienne et pariétale. Actuellement, en uro-gynécologie, l’utilisation des prothèses de synthèse est communément admise pour l’abord abdominal (cœlioscopique ou laparotomique) alors même que la voie vaginale est sujette à d’innombrables controverses. La rétraction prothétique représente un réel problème iatrogène, source de douleurs, d’érosion et de récidive, quelle que soit la voie d’abord utilisée. Il s’agit d’une complication sérieuse et, à l’heure actuelle, la moins documentée. L’étiopathogénie de cette rétraction reposerait sur les phénomènes adhérentiels de l’hôte, en réponse au matériau implanté (« contraction passive »). Objectifs : - Rechercher une solution à la rétraction prothétique. Le postulat de départ de cette thèse pose le fait que l’adjonction d’un gel ou d’un film d’acide hyaluronique, connus pour leur efficacité dans la diminution des adhérences post-opératoires, préviendrait la rétraction d’un implant en polypropylène chez la rate.- Établir un état des lieux, au lendemain des recommandations alarmistes américaines, mais plus nuancées et rassurantes de la part de nos sociétés savantes et experts européens vis-à-vis du recours au renfort prothétique en chirurgie vaginale.Matériels et méthodes : au décours d’une revue de la littérature, un modèle expérimental a été élaboré. Soixante rates ont été randomisées en 3 groupes. Un défect herniaire standard a été induit par laparotomie médiane au niveau de la paroi abdominale antérieure puis réparé par l’utilisation d’une prothèse en polypropylène de faible grammage macroporeux seule (groupe 1), avec application d’un film (groupe 2) ou avec enduction prothétique d’un gel (groupe 3) d’acide hyaluronique. Huit semaines après la procédure, une nouvelle laparotomie a été réalisée permettant l’évaluation d’un score adhérentiel et des surfaces prothétiques. Une étude histologique microscopique de l’interface hôte-tissu a également été effectuée.Résultats : Le groupe 1 (groupe contrôle), présentait un taux de rétraction prothétique de 29%. Les groupes 2 (p=0.0238) et 3 (p=0.0072) présentaient des taux de rétraction significativement plus bas, respectivement de 19.12% (groupe film) et 17% (groupe gel). La différence entre les 3 groupes était statistiquement significative (p=0.0153). Les adhérences post-opératoires étaient significativement moins importantes dans les groupes utilisant l’acide hyaluronique. Le groupe 1 présentait significativement un score adhérentiel plus élevé (30.40) que les groupes 2 (11.67, p=0.0028) et 3 (11.19, p=0.0013). La colonisation conjonctivale était moins intense dans le groupe gel, comparativement aux groupes film et témoin (p=0.0181).Conclusion et perspectives cliniques : Notre travail expérimental a démontré que la surface prothétique était sauvegardée de façon statistiquement significative lors du recours à un gel ou un film d’acide hyaluronique La rétraction prothétique, compliquant la chirurgie avec implant synthétique en polypropylène, pourrait être prévenue par l’adjonction de ce complément. Ceci préviendrait la formation d’adhérences post-opératoires et de fibrose, propices à la contraction du tissu hôte péri-prothétique et conduisant à la rétraction du matériau de renfort. Cette donnée devrait être intégrée dans une stratégie de sauvegarde prothétique préservant la qualité ainsi que la durée de la réparation chirurgicale tout en limitant la douleur post-opératoire. / IntroductionThe prolongation of life expectancy, which has for corollary the aging of the population, leads to predict of a growing appeal to the use of prosthetic reinforcement in surgery for pelvic statics’ disorders and parietal hernias. Currently, in uro-gynecology, the use of synthetic meshes is commonly admitted for the abdominal approach (by laparoscopy or laparotomy) while the vaginal route is subject to innumerable controversies. Prosthetic retraction (shrinkage) represents a real iatrogenic problem, causing pain, erosion and recurrence, whatever the approach used. This is a serious complication and, at the moment, the least documented. The etiopathogenesis of this retraction is based on host adhesion phenomena, in response to the implanted material ("passive contraction").Objectives-To research for a solution to prosthetic retraction. The basic premise of this thesis puts the fact that the addition of a gel or a film of hyaluronic acid, known for their effectiveness in reducing post-operative adhesions, would prevent the retraction of a polypropylene implant in a rat model.-To establish an update, the day after the American alarmist recommendations, but more nuanced and reassuring on behalf of our learned societies and European experts with regard to prosthetic reinforcement ‘use in vaginal surgery.Material and methods :Following a review of the literature, an experimental model was developed. Sixty rats were randomized into 3 groups. A standard hernial defect was induced by medial laparotomy in the anterior abdominal wall and then repaired using a macroporous low weight polypropylene mesh alone (group 1), with application of a film (group 2) or coating of a gel (group 3) of hyaluronic acid. Eight weeks after the procedure, a new laparotomy was realized to evaluate an adhesion score and prosthetic surfaces. A microscopic histological study of the host-tissue interface was also performed.Results :Group 1 (control group) had a mesh retraction rate of 29%. Groups 2 (p = 0.0238) and 3 (p = 0.0072) had significantly lower retraction rates, respectively 19.12% (film group) and 17% (gel group). The difference between the 3 groups was statistically significant (p = 0.0153). Post-operative adhesions were significantly less important in groups using hyaluronic acid. Group 1 had a significantly higher adherence score (30.40) than groups 2 (11.67, p = 0.0028) and 3 (11.19, p = 0.0013). Conjunctival colonization was less intense in the gel group, compared to the control and film groups (p = 0.0181).Conclusion and clinical perspectives :Our experimental study has shown that the prosthetic surface is protected in a statistically significant way when using a gel or film of hyaluronic acid. Mesh shrinkage, complicating surgery with synthetic polypropylene implant, could be prevented by the addition of this complement. This would prevent the formation of postoperative adhesions and fibrosis, which are conducive to contraction of the periprosthetic host tissue and leading to retraction of the reinforcing material. This data should be incorporated into a prosthetic safeguard strategy that preserves the quality as well as the duration of surgical repair while limiting post-operative pain.
2

Comportement biomécanique de la paroi abdominale et de ses composants musculaires : du spécimen isolé au patient / Biomechanical behavior of the abdominal wall and its muscular components : from isolated specimens to patient

Tran, Doris 10 December 2013 (has links)
Dans le but d’améliorer le traitement des éventrations, cette thèse porte sur la biomécanique de la paroi abdominale. Plusieurs aspects de son comportement ont été étudiés: de la paroi globale aux constituants, de la paroi passive ex vivo sous chargement contrôlé à la paroi active in vivo sous chargement physiologique et enfin de la paroi saine des volontaires non-malades à la paroi lésée des patients en pré-opératoire. Un protocole a été développé pour évaluer la contribution des composants de la paroi abdominale humaine ex vivo à sa réponse mécanique globale. Les spécimens sont sollicités par pression après dissection successive des différents composants. L’analyse par stéréo-corrélation des déformations de la surface interne a montré que la gaine des rectus abdominis joue un rôle important dans la réponse de la paroi abdominale antérieure. Les examens in vivo ont permis de considérer la paroi abdominale in situ de 11 volontaires non-malades et pour la première fois de patients souffrant d’éventration (n=4) en pré-opératoire. Géométrie externe et interne, élasticité des muscles et raideurs locales ont été mesurées lors d’activités physiologiques. Les paramètres mécaniques mesurés sur les patients restent soit dans l’étendue de mesure des valeurs des volontaires non malades, soit sont plus faibles. Dans le futur, l’inclusion d’autres patients et des examens post-opératoires seront poursuivis. On disposera alors de données quantitatives de la paroi abdominale couvrant l’état sain, lésé et réparé. Des modèles numériques pourront être développés. Ils permettront d’estimer l’influence de paramètres mécaniques et géométriques sur le comportement de la paroi abdominale / This thesis focuses on the biomechanics of the abdominal wall in order to help improving the treatment of incisional hernias. Several aspects of its response werestudied: from global wall to components, from passive wall ex vivo subjected to controlled loading to active wall in vivo under physiological loading and finally from intact wall of healthy volunteers to incised wall of herniated patients before repair surgery. A protocol was developed to assess the contribution of the components of the human abdominal wall ex vivo to the global mechanical response. The specimens were loaded by air pressure after dissection of different components. The strain analysis of the internal surface by stereo-correlation highlighted the importance of the rectus abdominis sheath in the response of the anterior abdominal wall. The in vivo examinations considered the entire abdominal wall in situ of 11 healthy volunteers and for the first time herniated patients before surgery (n=4). External and internal geometry, muscle elasticity and local stiffness were measured during various physiological activities. Mechanical parameters measured on patients remain either in the range of values obtained with healthy volunteers or lower. In the future, the inclusion of other patients and post-operative examinations will be conducted. This will provide quantitative data for the healthy, incised and repaired abdominal wall and support the development of numerical models to estimate the influence of mechanical and geometrical parameters on the behavior of the abdominal wall

Page generated in 0.1061 seconds