• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 2
  • Tagged with
  • 46
  • 46
  • 41
  • 18
  • 17
  • 17
  • 15
  • 15
  • 15
  • 13
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Emprego de filtro de fibra flexível constituído de sisal e de polipropileno na clarificação de água para abastecimento / Employment of flexible fiber filter made of sisal and polypropylene in the clarification of water to supply

Alice Kimie Martins Morita 12 June 2013 (has links)
Os filtros de fibra flexível são módulos de filtração recentemente desenvolvidos cujo leito é constituído de fibras de poliamida, o que permite a obtenção de altas eficiências de remoção de sólidos associadas a altas taxas de filtração. Este estudo objetivou avaliar o desempenho deste tipo de filtro utilizando-se como meio filtrante fibras flexíveis de sisal e de polipropileno. Com isso se buscou aprofundar o entendimento da técnica de filtração em leito de fibras flexíveis, além de propor e avaliar leitos com fibras diferentes daquelas citadas na literatura (constituídas de poliamida), neste caso fibras naturais (sisal) e fibras de polipropileno. A superfície das fibras em estudo foi analisada por meio de microscopia óptica e eletrônica de varredura e através de ensaios de solubilidade em ácido clorídrico e hidróxido de sódio, com a finalidade de investigar as características superficiais dos materiais filtrantes e sua solubilidade. Foram construídos 6 filtros com diâmetro interno de 28 mm e porosidade de leito de 93%, sendo 3 constituídos de fibras de sisal com comprimentos de leito de 25,60 e 100 cm, e 3 constituídos de fibras de polipropileno, também nos comprimentos de 25,60 e 100 cm. Em um segundo momento foi avaliado o desempenho de filtros constituídos de sisal nos mesmos comprimentos citados, no entanto com porosidade de leito de 85%. Foi utilizada para alimentação dos filtros água sintética com 8,19 ± 0,85 uT e 14,47 ± 5,25 uC e foi realizada coagulação in-line por meio da adição de 22,5 mg/L de sulfato de alumínio. Foram avaliadas taxas de filtração desde 5 m/h até 80 m/h no caso dos filtros do sisal com diferentes comprimentos e porosidades, e desde 20 m/h até 80 m/h no caso dos filtros de polipropileno. O limite de turbidez estabelecido para o filtrado foi de 1 uT. Puderam operar dentro do limite de turbidez estabelecido os filtros de polipropileno de 25,60 e 100 cm com taxa de 20 m/h e de 60 e 100 cm com taxas de até 80 m/h, e o filtro de sisal de 100 cm e 85% de porosidade com taxas de 20 e 40 m/h. Os maiores volumes de filtrado foram obtidos para filtro de polipropileno de 100 cm operando com taxa de 20 m/h, no entanto estes foram associados a maior perda de carga. Por outro lado, o filtro de sisal de 100 cm produziu menor quantidade de filtrado, porém com perda de carga associada consideravelmente baixa. Os melhores índices de filtrabilidade foram obtidos para o filtro de sisal de 100 cm de comprimento e 85% de porosidade de leito, o que indica seu potencial de aplicação, especialmente em ocasiões em que a carga hidráulica disponível seja restrita e a turbidez exigida do filtrado não seja demasiadamente baixa (inferior a 0,5 uT). Sugere-se a utilização de filtros constituídos de fibras de sisal como unidades de pré-filtração ou a construção de leitos com menor porosidade e maior comprimento de leito do que os utilizados neste estudo, caso se objetive aplicação em tratamento de água para abastecimento. Este estudo mostrou que é possível utilizar fibras de sisal e de polipropileno em filtros de fibras flexível, e a escolha dos diferentes tipos de fibras, comprimentos e porosidades de leito dependeria da disponibilidade no local, da qualidade do efluente exigida e da carga hidráulica disponível. / The flexible fiber filter is a filtration module recently developed whose filter media is made of polyamide fibers, what permits to obtain high solids removal efficiency associated to high application rates. The objective of this study was to evaluate the performance of this kind of filter using as filter media flexible fibers of sisal and polypropylene. With this it was intended to deepen the understanding of the filtration technique using flexible fibers as media and to propose and evaluate filter medias made of fibers different from the ones found in the literature: natural fibers (sisal) and polypropylene fibers. The fibers in study were analysed by means of optic and scanning electronic microscopy and through solubility essays in chloridric acid and sodium hydroxide, with the intention to characterize the filtering materials and find if there are restrictions of their use. Six filters with 28 mm of intern diameter and 93% of porosity were constructed, three being made of sisal fibers with 25, 60 and 100 cm of length, and three being made of polypropylene fibers, with 25,60 and 100 cm of length, too. In a second moment three other sisal fibers were constructed and evaluated, with the same lengths studied before, but with porosity of the filter medium of 85%. The filtration system was fed with synthetic water with 8,19 ± 0,85 uT and 14,47 ± 5,25 uC, and in-line coagulation was applied by the addition of 22,5 mg/L of aluminium sulfate. In the case of the sisal filters, made of different lengths and porosities, rates from 5 m/h to 80 m/h were evaluated; in the case of polypropylene filters, rates from 20m/h and 80m/h were evaluated. It was established as the turbidity limit the value of 1 uT. The filters that worked within the established turbidity limit were the polypropylene filters of 25,60 and 100 cm for the rate of 20 m/h and of 60 and 100 cm for rates until 80m/h, and the sisal filter of 100 cm and 85% of porosity for rates of 20 and 40 m/h. The biggest filtrate volumes were obtained for polypropylene filter of 100 cm working with the rate of 20 m/h; however this one was associated to the biggest values of pressure drop. On the other hand, the filter made of sisal with 100 cm produced a smaller quantity of filtrate, but associated to a considerably low value of pressure drop. The best filterability indexes were obtained for the filter made of sisal with 100 cm of length and 85% of porosity, what indicates its application potential, mainly to situations when there is not enough hydraulic charge and when the requested turbidity of the filtrate is not too low (less than 0,5 uT). It is suggested that the filters made of sisal are used as pre-filtration units or that they are built with smaller values of porosity and/or with a longer filter length than the ones used in this study, in the case that water treatment application is aimed. This study showed that it is possible to use sisal and polypropylene fibers in flexible fiber filters, and that the choice of different types of fibers, lengths and porosities depends on de availability of materials in the local, on the required quality of the filtrate and on the available hydraulic charge.
12

Influência da porosidade do leito e do diâmetro das fibras na eficiência da filtração com filtro de fibras flexíveis aplicado ao tratamento de água / Influence of the porosity and diameter of the fibers in filtration efficiency with flexible fibers filter applied to water treatment

Sá, Aline Beatriz Carvalho de 07 October 2016 (has links)
Os filtros de fibras flexíveis são unidades de filtração direta, compostos por leito de microfibras. São operados com altas taxas de filtração, garantindo alta eficiência de remoção de sólidos suspensos. Neste estudo avaliou-se a influência dos diâmetros das fibras, da porosidade do leito e da taxa de filtração na eficiência de clarificação de uma água sintética, utilizando filtro de fibras de poliamida. Foram construídos três filtros com diâmetro interno de 28mm e porosidade de 84%, cada um com leito de 100 cm de comprimento e diâmetro de fibra de 0,03, 0,11 e 0,32 mm e um filtro de mesmo diâmetro e comprimento, composto por fibras de 0,03 mm e porosidade 93%. A distribuição de água na entrada do filtro foi composta por 4 orifícios periféricos de 3,5 mm e um orifício central de 8 mm (Fundo de filtro Tipo 1 – FTipo1). Essa mesma entrada foi utilizada para a distribuição de água e ar na lavagem. Em um segundo momento, avaliou-se outra distribuição de água na entrada do filtro, com apenas quatro orifícios periféricos (Fundo de filtro Tipo 2 – FTipo2). Nessa nova configuração de filtro, foram avaliados os filtros de fibras de 0,03 mm, em duas porosidades: 84% e 93%. A água sintética possuía turbidez de 9,51 ± 0,22 uT e cor aparente de 86,4 ± 4,5 uC. A coagulação foi realizada in-line com sulfato de alumínio na dosagem de 22,5 mg.L-1. Em todos os filtros foram avaliadas três taxas de filtração: 60, 80 e 100 m h-1 e estabeleceu-se os limites de turbidez na água filtrada de 0,5 e 2,0 uT para o final da carreira de filtração. A distribuição de água na entrada do filtro mostrou-se de extrema importância para o bom funcionamento do mesmo, pois, dependendo da sua configuração, podem ocorrer emaranhamentos das fibras, comprometendo a eficiência de remoção de cor e turbidez. O filtro com fundo FTipo1 apresentou qualidade satisfatória para o filtro de fibras com diâmetro 0,11 mm, produzindo água filtrada com turbidez abaixo de 2,0 uT. O filtro de fibras de 0,03 mm de diâmetro conseguiu produzir qualidade dentro do limite estabelecido em alguns ensaios, entretanto não houve repetibilidade devido ao emaranhamento ocorrido no leito. Já o filtro de fibras de diâmetro 0,32 mm não atingiu turbidez satisfatória. Os dois filtros de fibras com fundo FTipo2 e porosidades 93% e 84%, respectivamente, conseguiram atingir os valores impostos para a turbidez da água filtrada em todas as taxas estudadas (60, 80 e 100m h-1) , com exceção do filtro de 93% de porosidade que não atingiu a turbidez mínima de 0,5 uT quando operado uma taxa de 100 m h-1. Ao final estimou-se os volumes de água filtrada produzidos no intervalo de um dia (24h) para cada filtro que atingiu os limites de turbidez pré-estabelecidos. Dentre as variações testadas em FTipo1 e FTipo2, concluiu-se que o volume diário de água produzida aumenta proporcionalmente ao aumento da taxa de filtração. Esse estudo demonstrou que o diâmetro da fibra, a porosidade e o fundo do filtro são características essenciais para o bom funcionamento do filtro, influenciando na eficiência de remoção de turbidez e cor aparente da água afluente. / The flexible fiber filters are direct filtration module, made of microfibers filter media. They are operated with high filtration rates ensuring high solids removal efficiency. This study evaluated the influence of diameters of fibers, porosity and filtration rates in the clarification efficiency of synthetic water. Three filters have been constructed with internal diameter of 28 mm and porosity of 84%, each with a filter medium of 100 cm length and fiber diameter of 0.03, 0.11 and 0.32 mm, and a filter of the same diameter and length, comprises fibers of 0.03 mm and porosity of 93%. The water distribution at the filter inlet was composed by four peripheral holes of 3.5 mm and a central hole of 8 mm (filter bottom Type 1 - FType1). That same input was used for water and air distribution in the wash. In a second step, was evaluated other water distribution in the filter inlet, with only four peripheral holes (filter bottom Type 2 - FType2). In this new filter configuration were evaluated 0.03 mm fiber filters with two porosity values: 84% and 93%. The synthetic water had turbidity of 9.51 ± 0.22 NTU and apparent color of 86.4 ± 4.5 uC. The coagulation was performed in-line with aluminum sulfate at a dosage of 22.5 mg.L-1. In all three filters were evaluated three filtration rates: 60, 80 and 100 m / h and fixed the limits of the filtered water turbidity of 0.5 and 2.0 NTU at the end of the career filter. The water distribution in the filter inlet proved to be extremely important for the proper functioning of the same, because, depending on your configuration, entanglements can occur, compromising the color and turbidity removal efficiency. The bottom filter FType1 presented a satisfactory quality for the fiber filter diameter 0.11 mm, producing filtered water with turbidity below 2.0 NTU. The filter of 0.03 mm diameter fibers could produce water quality within the limit in some tests, however there was no repeatability due to entanglement occurred in the bed. Other way, the 0.32 mm diameter fiber filter has not reached satisfactory turbidity. The two fibers filters FType2 and porosity 93% and 84%, respectively, were able to achieve values imposed to the turbidity of the filtered water in all studied rates (60, 80 and 100 m.h-1), except 93% porosity filter witch not reached the minimum turbidity of 0.5 NTU when operated a 100 m.h-1 rate. At the end was estimated the volumes of the filtered water produced within one day (24h) for each filter that has reached the limits of predetermined turbidity. Among the variations tested FType1 and FType2, can be concluded that the daily water volume produced increases with the filtration rate increasing. This study demonstrated that the fiber diameter, porosity and filter bottom characteristics are essential for the proper functioning of the filter, influencing the apparent color and turbidity removal efficiency of influent water.
13

Fundamentação da cobrança pelo uso da água na agricultura irrigada, na microbacia do Ribeirão dos Marins, Piracicaba/SP / Fundamentation of water use charges in agricultural irrigation, in the smallcatchment basin of River Marins, Piracicaba/SP

Faganello, Célia Regina Ferrari 04 June 2007 (has links)
A atual crise mundial de abastecimento hídrico e os conseqüentes problemas relativos ao uso da água são grandes problemas a serem enfrentados pela humanidade, levando à necessidade de se encontrar soluções para prevenir conseqüências negativas ao ambiente. A cobrança pelo uso da água na agricultura irrigada, baseada nos princípios de direito ambiental usuário-pagador e poluidor–pagador, a aplicação dos princípios protetor-recebedor e participação, bem como a educação ambiental, são ferramentas de gestão de recursos hídricos com efeito indutor do uso racional da água, fomentando a consciência de conservação nos usuários irrigantes. A importância desta abordagem holística na implementação da cobrança em uma dada bacia hidrográfica está baseada na integração dos aspectos técnicos das propriedades irrigadas, na legislação ambiental e nas necessidades da comunidade local, para se adequar a cobrança aos usuários irrigantes de forma que a mesma se torne uma aliada no combate ao desperdício e à melhor eficiência no seu uso. Os objetivos deste trabalho foram: i) realizar a avaliação qualitativa da irrigação em 11 propriedades rurais da Microbacia do Ribeirão dos Marins (BHRM); ii) fundamentar o instrumento de cobrança pelo uso da água na agricultura irrigada com base nos princípios de direito ambiental Poluidor-Pagador e Usuário-Pagador; iii) discutir o princípio da Participação; iv) fundamentar o sistema de pagamento por serviços ecossistêmicos (PSE); v) fornecer elementos para futuras intervenções de gestão na microbacia voltadas a elaboração de projetos de educação ambiental integrados ao gerenciamento de recursos hídricos. Foram aplicados aos irrigantes roteiros de entrevista semi-estruturada. Os resultados mostraram que o manejo da irrigação não é praticado, a preocupação com a escassez de água é presente; a cobrança pelo uso da água não é aceita, o controle da erosão não é feito e há concordância com a importância da preservação da mata ciliar. Além disso, os resultados forneceram elementos que indicam a ausência de compreensão dos impactos causados pelo manejo inadequado da água, o que pôde ser traduzido pelos graves problemas de degradação de água, solo e mata ciliar detectados. Conclui-se que para induzir mudanças nos usuários irrigantes, promovendo o uso eficiente dos recursos hídricos, através do mecanismo de cobrança pelo uso da água, é necessário conjugar o direito ambiental, a tecnologia de irrigação e a educação ambiental. / The current crisis in water supply worldwide and the associated water use problems are one of the great concerns for the humanity, leading to the necessity to find solutions to prevent harmful consequences in the environment. Charges for water use in agricultural irrigation, supported by principles of environmental law as "user-payer" and "polluting payer", the application of "protector-receiver" and "participation" principles as well as environmental education, represent tools in water management with inductive effects on rational water use, broadening the awareness of irrigation users for the sustainment of natural water resources. The carrying out of this holistic approach in the implementation process of water use charges in a given catchment basin is based on the integration of technical aspects of the irrigated areas, environmental legislation and the necessities of the local community to establish individually adapted charges for water use with the result to decrease wastefulness and increase the water use efficiency. The objectives of this work were: (i) a qualitative evaluation of irrigation use in 11 rural areas in the small catchment basin of river Marins; (ii) to base the charge system for water use in agricultural irrigation on basis of the environmental law principles "user-payer" and "polluting payer"; (iii) to argue the principle of "participation"; (iv) to base the payment for ecosystem services (PSE); (v) to provide a basis for future management interventions in the basin with the objective to design environmental education projects, integrated in the management activities of water resources. The study based on semi-structural interviews with irrigation users in the respective areas. The results showed that irrigation management is not practiced, the preoccupation with water deficiency exist, water use charges is not accepted, the monitoring of erosion processes is not done and there is an agreement with the importance to preserve the riverine vegetation. Moreover, the results indicated a lack of knowledge about the impacts caused by inadequate water management that is expected to be the reason for the already existing degradation of water, soil and riverine vegetation. It can be concluded, that for attitude changes of irrigation users in terms of more efficient use of water resources associated with charges for water use interdisciplinary collaborations of environmental law, irrigation management and environmental education are necessary.
14

Qualidade da água utilizada para consumo em escolas públicas municipais de ensino infantil de Ribeirão Preto - SP / Quality of water supplied for consumption in municipal public primary schools in Ribeirão Preto - SP.

Castania, Janaina 14 August 2009 (has links)
A água é um elemento essencial à vida, mas que pode trazer riscos à saúde humana se houver comprometimento de sua qualidade. As crianças são as que mais sofrem com problemas decorrentes da ingestão de água contaminada, uma vez que são mais vulneráveis devido à imaturidade de seu sistema imune. Nesse contexto, destaca-se a importância de um levantamento da qualidade da água para consumo em escolas, uma vez que a escola representa um importante ambiente no qual se insere a criança. Este estudo objetivou avaliar a qualidade da água consumida por escolares da cidade de Ribeirão Preto-SP, analisando sua qualidade em relação aos parâmetros físicos, químicos e microbiológicos, assim como identificando possíveis riscos ligados à água como via de transmissão de enteropatógenos, e oferecer subsídios para as autoridades sanitárias, no que se refere ao controle da qualidade da água utilizada por escolares. Foram analisadas amostras provenientes das torneiras de entrada, dos bebedouros e das cozinhas de 20 instituições de ensino infantil da rede pública municipal, constituindo-se de 8 creches e 12 escolas de ensino infantil, em duas fases do ano de 2008, sendo a primeira de maio a julho e a segunda de setembro a dezembro. Foram realizadas análises físico-químicas para determinação dos teores de turbidez, pH, cloro, nitrato e flúor, e análises microbiológicas para determinação de coliformes totais e fecais, tomando-se como parâmetro a Portaria MS nº 518/04 e a Resolução (SP) SS-65/05 para flúor. Os resultados obtidos revelaram que todas as amostras apresentaram-se de acordo com a legislação para os parâmetros turbidez, nitrato, coliformes totais e fecais. Os valores de pH das amostras provenientes de cinco instituições (na primeira fase de coleta) e de 4 instituições (na segunda fase) apresentaram-se inferiores ao recomendado pela legislação nacional. Em relação ao cloro, 15% das amostras, na primeira fase de coleta, e 1,66% na segunda fase, apresentaram valores fora dos padrões estabelecidos pela legislação nacional. Quanto ao flúor, todas as amostras analisadas apresentaram-se em desacordo com a legislação estadual. A análise estatística dos resultados para os parâmetros, turbidez, pH, nitrato e flúor, revelou que não foram observadas diferenças significativas (p>0,05) nas amostras analisadas dos diferentes pontos de coleta nas duas fases. Quanto ao cloro, pôde-se verificar que, tanto para a primeira quanto para a segunda fase da coleta de dados, houve diferença significativa (p<0,05) quando comparadas amostras de água de torneiras com bebedouros e torneiras com cozinhas. Quando comparadas as amostras coletadas das cozinhas com as dos bebedouros, essas não apresentaram diferença estatística. Os resultados obtidos revelam a necessidade de ações corretivas em todas as etapas de fornecimento de água para a população, além do monitoramento e controle da qualidade da água para consumo humano, tanto pelos responsáveis pelo abastecimento, quanto pelas autoridades sanitárias. / Water is an essential element to life but can bring risks to human health if consumed with improper quality. Children are the most affected group with problems resulting from ingestion of contaminated water due to their vulnerability regarding to the immaturity of their immune system. In this context there is important a survey of water quality for consumption in schools once the school is an important environment which the child inserts. This study aimed to evaluate the quality of water consumed by children from Ribeirão Preto-SP, considering their quality in relation to physical, chemical and microbiological tests, as well as identifying possible risks related to water as a route of transmission of enteropathogens, and offer subsidies to health authorities as regards the control of water quality used by schoolchildren. Were analyzed samples from the entry taps, water drinker and kitchens of 20 municipal public primary schools in Ribeirão Preto - SP, being, 8 kindergartens and 12 schools from child education in two phases in the year 2008, the first of may to july and the second from september to december. Were performed physical and chemical analysis to determine levels of turbidity, pH, chlorine, nitrate and fluoride, and microbiological analysis for determination of total and fecal coliforms, taking as parameter the Ordinance MS n º 518/04 and Resolution (SP) SS -65/05 for fluoride. The results showed that all samples are presented in accordance with the law for the turbidity, nitrate, total and fecal coliforms parameters. The pH values of samples from five institutions (the first phase) and from four institutions (in the second phase) were lower than recommended by national legislation. For the chlorine, 15% of samples in the first phase of data collection, and 1.66% in the second phase showed values outside the standards set by national legislation. For fluoride, all samples showed values outside the standards set by resolution. Statistical analysis for turbidity, pH, nitrate and fluoride parameters, revealed no significant differences (p> 0.05) in samples collected from different points of the two phases. For chlorine, it was observed that for both the first and for the second phase of data collection, significant difference (p <0.05) compared samples of water from taps with drinkers and taps with kitchens. No statistical difference was observed comparing the samples collected from the kitchens with water drinker. The results pointed that corrective actions are needed at all stages of population water supply in addition to monitoring and control of water quality for human consumption, both by those responsible for the supply, as the health authorities.
15

Quantificação da produção de lodo de estações de tratamento de água de ciclo completo: uma análise crítica. / Quantification of the production of residuals in complete-cycle water treatment plants: a critical analysis.

Katayama, Victor Takazi 06 December 2012 (has links)
Grande parte do lodo gerado em ETAs no Brasil ainda é disposta em rios ou em aterros sanitários. Contudo, principalmente em grandes centros urbanos, condições de licenciamento ambiental restritivas e custos logísticos crescentes tem levantado interesse em usos benéficos para esse resíduo. Um obstáculo para a mudança de paradigma recai no fato de que muito raramente operadores e projetistas de ETAs nacionais conseguirem prever, com algum grau de confiabilidade, a massa e volume de resíduos produzidos pelo tratamento da água bruta. Geralmente, usa-se para esse fim fórmulas empíricas, que relacionam a produção de lodo à concentração de sólidos em suspensão totais (SST) na água bruta e à dosagem de produtos químicos. Os objetivos deste trabalho são: comparar o desempenho de dois dos principais métodos quantitativos de estimativa de produção de lodo o método de fórmulas empíricas, e o do balanço de massa; investigar a prática disseminada de se estimar a concentração de sólidos em suspensão totais na água bruta por meio de modelos de regressão linear com a turbidez como variável independente; e delinear condições para a aplicação dessa correlação. Foram utilizados dados de seis ETAs de ciclo completo operadas pela SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), além de dados de monitoramento de 130 estações de monitoramento de águas superficiais da CETESB. Os resultados sugerem que a identificação de correlações significativas entre concentração de SST e turbidez é elusiva, e não constitui tarefa trivial. Do universo de 130 estações da CETESB, somente 7 apresentaram correlação significativa; das ETAs, somente Presidente Prudente. Modelos de regressão alternativos utilizando outras variáveis (cor, vazão média mensal e mês), combinadas com a turbidez ou isoladamente, foram desenvolvidos. Somente a inclusão do mês como variável categórica foi capaz de aumentar o poder explicativo do modelo baseado exclusivamente na turbidez, sugerindo que a relação entre turbidez e concentração de SST é variável sazonalmente. Mediante a comparação com balanços de massa, foram identificados alguns fatores que afetam o poder de predição da fórmula empírica desenvolvida pela American Water Works Association, algumas vezes de maneira drástica. Em geral, conclui-se que o uso de fórmulas empíricas principalmente em conjunto com modelos de regressão entre concentração de SST e turbidez possa não ser recomendável. / Most of the water treatment plant (WTP) residuals generated in Brazil is still discharged in water bodies, or disposed of in landfills. However, especially in large urban areas, ever stringent conditions for environmental permits e rising logistical costs have put into focus beneficial uses for those residuals. A major obstacle for paradigm change in that aspect lies in the fact that very rarely water treatment plant operators and designers are able to predict with some degree of certainty the mass and volume of residuals produced by the treatment process. Usually, empirical formulas are used for that end, which relates the residuals production rate to the concentration of total suspended solids (TSS) in the raw water, and the chemicals dose. The objectives of this work are: to compare the performance of two of the main quantitative estimation methods for residuals production the empirical formulas and the mass balance; to investigate the widespread practice of estimating the concentration of TSS using turbidity as a surrogate; and to identify the conditions under which such procedure is acceptable. For that end, data from six WTPs operated by SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), plus 130 surface water monitoring stations operated by CETESB, was analyzed. Alternative regression models, employing other independent variables (color, average monthly flow and month) singly or in combination with turbidity, were developed. Only the inclusion of the month as a categorical variable was capable of enhancing the explaining power of the turbidity model, suggesting that the relation between turbidity and TSS concentration is seasonally variable. The results suggest that identification of such significant correlations between TSS concentration and turbidity is elusive at best, and doesn\'t amount to a trivial task. Out of the universe of 130 monitoring stations, in only 7 a good degree of correlation was found; of the WTPs, that was the case only in Presidente Prudente. Through the comparison with the mass balances, some factors that affect the predictive power of the American Water Works Association sometimes drastically a were identified. In general, it is concluded that the use of empirical formulas especially when combined with turbidity and TSS concentration regression models may not be recommended.
16

A influência do Comitê das Bacias Hidrográficas dos rios Piracicaba, Capivari e Jundiaí (CBH-PCJ) na descentralização da gestão hídrica brasileira - avaliação quantitativa da participação da sociedade civil de 1993-2003 / The influence of the Committee of Hydrographic Basins of Piracicaba, Capivari e Jundiaí rivers (CBH-PCJ) on decentralization of brazilian hydric management - quantitative evaluation of participation of civil society between 1993 and 2003

Morgado, Alessandra 17 June 2008 (has links)
A bacia hidrográfica que compreende o Comitê das Bacias Hidrográficas dos rios Piracicaba, Capivari e Jundiaí (CBH-PCJ) está localizada numa região estratégica do ponto de vista econômico e político, concentrando 4,5 milhões de habitantes e 8% do Produto Interno Bruto (PIB) nacional, além de ser um pólo de pesquisas que reúne universidades estaduais e institutos de pesquisa. Trata-se de uma região altamente desenvolvida com zonas de adensamento populacional, como a região de Campinas, que tem 1 milhão de habitantes e, conseqüentemente, com alta taxa de degradação ambiental. Ao mesmo tempo, a região apresenta uma disponibilidade hídrica muito baixa, de 385 m3 ha-1ano-1, volume que equivale à disponibilidade de países semi-áridos da África, resultando em conflitos pela água na região. Essas características fazem do CBH-PCJ um colegiado modelo no Estado e no país. Esse trabalho teve por objetivo traçar um histórico do Comitê das Bacias Hidrográficas dos rios Piracicaba, Capivari e Jundiaí (CBH-PCJ), desde sua fundação, ocorrida em 1993, até a renovação da outorga do Sistema Cantareira em agosto de 2004. O CBH-PCJ é um colegiado formado por representantes dos governos estadual e municipal, além da sociedade civil (organizações não-governamentais), que tem por finalidade gerir as questões ligadas aos recursos hídricos no âmbito da bacia. O estudo avaliou quantitativamente a participação da sociedade civil nas reuniões plenárias do comitê ao longo de dez anos (1993-2003), por meio das listas de presença das reuniões ordinárias e extraordinárias, relacionando a participação à pauta da reunião. O resultado contrariou a hipótese inicial de baixa participação da sociedade civil em relação aos outros setores do colegiado, representados por municípios e órgãos estaduais. O índice de participação da sociedade civil nas primeiras cinco gestões do colegiado teve mínimas de 56,4%, mas manteve entre 70% e 80% presença nas reuniões. Foram selecionados para análise os dez primeiros anos de funcionamento do colegiado no âmbito do Estado de São Paulo, o que compreende de 1993 até 2003, sendo que neste período o colegiado atuava no âmbito estadual. O trabalho também relacionou a opinião de três sindicatos rurais da região do CBH-PCJ, integrantes da Câmara Técnica Rural, sobre a participação no colegiado. O setor considera a participação desses sindicatos importante no sentido de garantir a representação dos agricultores e os interesses da classe. Esse setor foi escolhido porque é responsável por parte considerável do consumo de água dos mananciais para fins de irrigação de culturas. / The water basin wich understands the Piracicaba, Capivari and Jundiai rivers and basin Comitee (CBH-PCJ) is located over a strategic region concerning political and economical view. This region concentrates 4,5 milion inhabitants and 8% of brazilian production, besides its a centre where state universities and institutes base their researches. This is highly developed region in São Paulo State with population gathering zones as Campinas and its surroundings whose 1 milion inhabitants cause great environment degradation. This region presents also low hidrical availability (385 m3 ha-1 year-1) that is similiar to some African countries, wich leads to conflict for water use and supply. Such characteristics turn CBH-PCJ into a model for São Paulo and Brazil. This work aims to draw a historical view of Piracicaba, Capivari and Jundiaí Basins Comitee, from its stablishment in 1993 to the reassignment of Cantareira Sistems concession in 2004. CBH-PCJ is formed by State and cities governments and the civil society, and has the purpose of managing problems related to water sources in these above refered rivers. This study evaluated civil society participation in the Comitee PCJ meetings for ten years - from 1993 to 2003 - throughout presence lists relating meeting topics of frequency. The results went agaist the initial hipotesys of low civil participation in relation to the other State and cities representatives. Civil Society participation rates lowerd to a 56,4% in the first mandates, but sustained in average of 70% to 80% of presence in the meettings. The ten first years of works (1993-2003) when the Comitee actions were taken on the State ambit were selected for this analisys.This essay also relates the opinion of three local rural sindicates, integrals of Rural Technical Council. These sindicates participation is considered to be important to assure agricultors participation and matters as they are responsasible for considerable water consumption for irrigation their crops.
17

Influência da taxa de aplicação superficial e da concentração de ar na eficiência de clarificação de água de abastecimento em unidades de flotação por ar dissolvido / Influence of surface application fee and concentration of air in efficiency of clarification of water supply in units dissolved air flotation

Escher, Aline Eléia 22 September 2011 (has links)
Os objetivos deste trabalho foram verificar a influência das taxas de aplicação superficial das zonas de separação e de contato e da concentração de micro bolhas de ar na eficiência da remoção de partículas em unidades de flotação aplicadas ao tratamento de água para abastecimento público e, caracterizar a estrutura de escoamento no interior da zona de separação, com a utilização de uma planta piloto de flotação por ar dissolvido. Os trabalhos relativos à pesquisa foram divididos em duas etapas: a primeira delas contemplou a operação de unidade piloto alimentada com água sintética, utilizando três valores de taxa de aplicação superficial na zona de separação associadas a duas taxas de aplicação superficial na zona de contato, cada qual com três concentrações de ar fornecido à flotação. Foram mantidos fixos os parâmetros: tempo de contato na zona de contato, tempo de floculação, gradiente médio de floculação e velocidade cross-flow. Os resultados desta etapa foram monitorados com base na eficiência de remoção de cor e turbidez. As maiores eficiências de remoção, 87,5% para turbidez e 96,8% de cor aparente foram obtidos para as menores taxas de aplicação superficial nas zonas de contato e separação estudadas, associadas à concentração de ar de 4,90 g/\'CM POT.3\' de água. Este, entre outros resultados, levou à conclusão de que tal concentração de ar fornecida à flotação forneceu sempre os menores residuais de cor e turbidez nas condições investigadas. Quanto à taxa de aplicação superficial na zona de contato, 136,3 m/h resultou em maiores eficiências de clarificação, sendo que o aumento para 172,8 m/h causou ligeira queda na eficiência. Finalmente, quanto à taxa de aplicação superficial na zona de separação, a menor taxa (9,8 m/h) foi aquela onde as maiores eficiências de clarificação foram obtidas, as quais decresceram à medida que a taxa foi aumentada. Na segunda etapa utilizou-se a sonda microADV na caracterização do escoamento no interior da zona de separação. Foram realizadas caracterizações para as três concentrações de ar fornecidas para a flotação estudadas na etapa I, mantendo-se fixos a taxa de aplicação superficial e o tempo na zona de contato (136,3 m/h e 53 s, respectivamente), a taxa de aplicação superficial na zona de separação (12,3 m/h), a vazão de entrada e a velocidade cross-flow, conforme a etapa I. Para as três condições estudadas, adotou-se uma malha virtual de coleta de dados de duas dimensões, composta por 98 pontos igualmente espaçados, sendo 14 na altura e 7 paralelos ao comprimento. O tempo de coleta de dados em cada ponto foi de 2 min com uma freqüência de amostragem de 50 Hz. Os vetores de velocidade resultantes foram plotados em esquemas ilustrativos, afim de se comparar os três perfis obtidos. Observou-se em todos os casos um fluxo em curto-circuito na região superior da zona de separação e logo abaixo desta, um fluxo descendente no sentido dos coletores ao fundo da unidade. Quando comparadas, apenas pequenas diferenças quanto à espessura da região de curto circuito superior foram verificadas entre as três situações abordadas, as quais não explicam as diferentes eficiências de clarificação obtidas na etapa I da pesquisa, relacionadas à concentração de ar fornecida à flotação. / The objectives of this study were to determine the influence of hydraulic surface loading of contact and separation zones and of the air micro bubbles concentration in the particle removal efficiency in flotation units applied to water treatment for public supply and also characterize the flow structure into the separation zone. The works were divided into two stages: the first included the operation of the pilot plant fed with synthetic water, using three values of hydraulic surface loadings in the separation zone associated with two hydraulic surface loadings in the superficial zone of contact, each one with three concentrations of air supplied to the flotation. Were kept fixed parameters: contact time in the contact zone, flocculation time, mean flocculation gradient and cross-flow velocity. The results of this step were monitored based on the removal efficiency of color and turbidity. The higher removal efficiencies, 87.5% of turbidity and 96.8% apparent color were obtained for the lower hydraulic surface loading of contact and separation zones studied, associated with air concentration of 4.90 g/\'CM POT.3\' of water. This, among other results, led to the conclusion that this air supplied to the flotation concentration always provided the lowest residual color and turbidity values, under the conditions investigated. As for the hydraulic surface loading in the contact zone, 136.3 m/h resulted in higher efficiencies for clarification and when increasing to 172.8 m/h slight drop in efficiency was caused. Finally, regarding separation zone hydraulic surface loading, the lowest rate (9.8 m/h) was the one in which the highest efficiencies of clarification were obtained, which decreased, as the hydraulic surface loading was increased. In the second step, the probe microADV was used to characterize the flow inside the separation zone. Characterizations were carried out for the three air concentrations supplied to the flotation studied on the first step, fixing contact zone hydraulic surface loading and time (136.3 m/h and 53 s, respectively), the separation zone hydraulic surface loading (12.3 m/h), the input flow and cross-flow velocity as step I. For the three conditions studied, we adopted a of two-dimensional virtual data collection grid with 98 equally spaced points, 14 in height and 7 parallel to the length. The data collection time at each point was 2 min with a sampling frequency of 50 Hz. The resulting velocity vectors were plotted on illustrative diagrams in order to compare the three profiles obtained. A short-circuit flow in the upper part of the separation zone and below this, a downward flow toward the bottom of the collector unit were observed in all cases. In comparison, only small differences in the thickness of the upper region of short circuit were observed between the three situations discussed, which do not explain the different efficiencies of clarification obtained in the first step of the research related to the air bubble concentration.
18

Construção e avaliação de hidrociclone para pré-filtragem da água de irrigação. / Construction and evaluation of hydrocyclone for pre-filtering irrigation water.

Soccol, Olivio José 28 February 2003 (has links)
Na agricultura irrigada, a qualidade da água utilizada é de fundamental importância para o perfeito funcionamento dos sistemas de irrigação e de seus componentes. A utilização de água contendo sedimentos em suspensão tem sido a causa de sérios problemas em sistemas de irrigação, reduzindo a vida útil de seus componentes, promovendo o entupimento de tubulações e emissores, ocasionando como conseqüência, irrigações não uniformes e queda na eficiência dos mesmos. A escolha do tipo e capacidade do sistema de filtragem é de fundamental importância, evitando-se assim, aumento nos custos de operação e manutenção do sistema de irrigação, devido a necessidade de limpeza e trocas freqüentes de seus componentes. Pré-filtros, como os hidrociclones, desempenham importante papel, pois se caracterizam por significativo poder de separação de partículas, maiores do que 100 mm, presentes na água; mantendo constante a perda de carga ao longo do tempo, o que não ocorre com os outros tipos de filtros normalmente utilizados nos sistemas de irrigação. Apesar de algumas referências feitas aos hidrociclones em literatura internacional, não se dispõe, no Brasil, de dados do desempenho dos hidrociclones, quando empregados em pré-filtragem da água utilizada nos sistemas de irrigação. Assim, um experimento conduzido no Laboratório de Hidráulica do Departamento de Engenharia Rural da ESALQ/USP, compreendeu a construção de quatro hidrociclones do tipo Rietema, com diâmetro de 50 mm, um com bocal de alimentação circular e os demais com bocais de seção retangular, cujas seções foram decrescentes. A avaliação do desempenho dos mesmos foi realizada utilizando-se suspensões de areia fina e solo argiloso, sob diferentes diferenciais de pressão, adotando-se como critério de comparação, a capacidade de vazão e o poder de separação, medido pela eficiência total e eficiência total reduzida. Os resultados obtidos mostraram que o hidrociclone dotado com bocal de alimentação circular apresentou os maiores índices nos critérios de comparação, tanto para a suspensão de areia, quanto para a de solo. / Good water quality is uppermost in irrigated agriculture for the perfect functioning of irrigation systems and their components. The use of water containing suspended sediments has caused serious problems to irrigation systems, reducing the useful life of their components, clogging pipes and emitters, consequently causing non-uniform irrigations and low efficiency. Choosing the right filtering system type and capacity is essential to avoid increases in operational and maintenance costs of irrigation systems due to the need for cleaning and frequent replacing of their components. Pre-filters, such as hydrocyclones, are important for their significant capability to retain particles larger than 100 mm present in water, keeping the head loss constant with the time, unlike other filters normally used in irrigation systems. Despite being present in the international literature, data on the performance of hydrocyclones used for pre-filtering irrigation water in Brazil are not available. Therefore, four Rietema type hydrocyclones (50 mm diameter) were construction in the Hydraulics Laboratory of the Rural Engineering Department - ESALQ/USP- one presenting circular-end feeding tube and the other three presenting rectangular-end feeding tubes with decreasing sections. The evaluation of the hydrocyclones performance was conducted by using suspensions of fine sand and clay soil under various pressure differentials. The comparison criteria used were the discharge and the separation capability, given by total efficiency and reduced total efficiency. Results showed that the hydrocyclone with circular-end feeding tube presented the highest indexes for the comparison criteria adopted, considering sand and soil suspensions.
19

Quantificação da produção de lodo de estações de tratamento de água de ciclo completo: uma análise crítica. / Quantification of the production of residuals in complete-cycle water treatment plants: a critical analysis.

Victor Takazi Katayama 06 December 2012 (has links)
Grande parte do lodo gerado em ETAs no Brasil ainda é disposta em rios ou em aterros sanitários. Contudo, principalmente em grandes centros urbanos, condições de licenciamento ambiental restritivas e custos logísticos crescentes tem levantado interesse em usos benéficos para esse resíduo. Um obstáculo para a mudança de paradigma recai no fato de que muito raramente operadores e projetistas de ETAs nacionais conseguirem prever, com algum grau de confiabilidade, a massa e volume de resíduos produzidos pelo tratamento da água bruta. Geralmente, usa-se para esse fim fórmulas empíricas, que relacionam a produção de lodo à concentração de sólidos em suspensão totais (SST) na água bruta e à dosagem de produtos químicos. Os objetivos deste trabalho são: comparar o desempenho de dois dos principais métodos quantitativos de estimativa de produção de lodo o método de fórmulas empíricas, e o do balanço de massa; investigar a prática disseminada de se estimar a concentração de sólidos em suspensão totais na água bruta por meio de modelos de regressão linear com a turbidez como variável independente; e delinear condições para a aplicação dessa correlação. Foram utilizados dados de seis ETAs de ciclo completo operadas pela SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), além de dados de monitoramento de 130 estações de monitoramento de águas superficiais da CETESB. Os resultados sugerem que a identificação de correlações significativas entre concentração de SST e turbidez é elusiva, e não constitui tarefa trivial. Do universo de 130 estações da CETESB, somente 7 apresentaram correlação significativa; das ETAs, somente Presidente Prudente. Modelos de regressão alternativos utilizando outras variáveis (cor, vazão média mensal e mês), combinadas com a turbidez ou isoladamente, foram desenvolvidos. Somente a inclusão do mês como variável categórica foi capaz de aumentar o poder explicativo do modelo baseado exclusivamente na turbidez, sugerindo que a relação entre turbidez e concentração de SST é variável sazonalmente. Mediante a comparação com balanços de massa, foram identificados alguns fatores que afetam o poder de predição da fórmula empírica desenvolvida pela American Water Works Association, algumas vezes de maneira drástica. Em geral, conclui-se que o uso de fórmulas empíricas principalmente em conjunto com modelos de regressão entre concentração de SST e turbidez possa não ser recomendável. / Most of the water treatment plant (WTP) residuals generated in Brazil is still discharged in water bodies, or disposed of in landfills. However, especially in large urban areas, ever stringent conditions for environmental permits e rising logistical costs have put into focus beneficial uses for those residuals. A major obstacle for paradigm change in that aspect lies in the fact that very rarely water treatment plant operators and designers are able to predict with some degree of certainty the mass and volume of residuals produced by the treatment process. Usually, empirical formulas are used for that end, which relates the residuals production rate to the concentration of total suspended solids (TSS) in the raw water, and the chemicals dose. The objectives of this work are: to compare the performance of two of the main quantitative estimation methods for residuals production the empirical formulas and the mass balance; to investigate the widespread practice of estimating the concentration of TSS using turbidity as a surrogate; and to identify the conditions under which such procedure is acceptable. For that end, data from six WTPs operated by SABESP (ABV, Alto Cotia, Cubatão, Guaraú, Franca e Presidente Prudente), plus 130 surface water monitoring stations operated by CETESB, was analyzed. Alternative regression models, employing other independent variables (color, average monthly flow and month) singly or in combination with turbidity, were developed. Only the inclusion of the month as a categorical variable was capable of enhancing the explaining power of the turbidity model, suggesting that the relation between turbidity and TSS concentration is seasonally variable. The results suggest that identification of such significant correlations between TSS concentration and turbidity is elusive at best, and doesn\'t amount to a trivial task. Out of the universe of 130 monitoring stations, in only 7 a good degree of correlation was found; of the WTPs, that was the case only in Presidente Prudente. Through the comparison with the mass balances, some factors that affect the predictive power of the American Water Works Association sometimes drastically a were identified. In general, it is concluded that the use of empirical formulas especially when combined with turbidity and TSS concentration regression models may not be recommended.
20

Influência da taxa de aplicação superficial e da concentração de ar na eficiência de clarificação de água de abastecimento em unidades de flotação por ar dissolvido / Influence of surface application fee and concentration of air in efficiency of clarification of water supply in units dissolved air flotation

Aline Eléia Escher 22 September 2011 (has links)
Os objetivos deste trabalho foram verificar a influência das taxas de aplicação superficial das zonas de separação e de contato e da concentração de micro bolhas de ar na eficiência da remoção de partículas em unidades de flotação aplicadas ao tratamento de água para abastecimento público e, caracterizar a estrutura de escoamento no interior da zona de separação, com a utilização de uma planta piloto de flotação por ar dissolvido. Os trabalhos relativos à pesquisa foram divididos em duas etapas: a primeira delas contemplou a operação de unidade piloto alimentada com água sintética, utilizando três valores de taxa de aplicação superficial na zona de separação associadas a duas taxas de aplicação superficial na zona de contato, cada qual com três concentrações de ar fornecido à flotação. Foram mantidos fixos os parâmetros: tempo de contato na zona de contato, tempo de floculação, gradiente médio de floculação e velocidade cross-flow. Os resultados desta etapa foram monitorados com base na eficiência de remoção de cor e turbidez. As maiores eficiências de remoção, 87,5% para turbidez e 96,8% de cor aparente foram obtidos para as menores taxas de aplicação superficial nas zonas de contato e separação estudadas, associadas à concentração de ar de 4,90 g/\'CM POT.3\' de água. Este, entre outros resultados, levou à conclusão de que tal concentração de ar fornecida à flotação forneceu sempre os menores residuais de cor e turbidez nas condições investigadas. Quanto à taxa de aplicação superficial na zona de contato, 136,3 m/h resultou em maiores eficiências de clarificação, sendo que o aumento para 172,8 m/h causou ligeira queda na eficiência. Finalmente, quanto à taxa de aplicação superficial na zona de separação, a menor taxa (9,8 m/h) foi aquela onde as maiores eficiências de clarificação foram obtidas, as quais decresceram à medida que a taxa foi aumentada. Na segunda etapa utilizou-se a sonda microADV na caracterização do escoamento no interior da zona de separação. Foram realizadas caracterizações para as três concentrações de ar fornecidas para a flotação estudadas na etapa I, mantendo-se fixos a taxa de aplicação superficial e o tempo na zona de contato (136,3 m/h e 53 s, respectivamente), a taxa de aplicação superficial na zona de separação (12,3 m/h), a vazão de entrada e a velocidade cross-flow, conforme a etapa I. Para as três condições estudadas, adotou-se uma malha virtual de coleta de dados de duas dimensões, composta por 98 pontos igualmente espaçados, sendo 14 na altura e 7 paralelos ao comprimento. O tempo de coleta de dados em cada ponto foi de 2 min com uma freqüência de amostragem de 50 Hz. Os vetores de velocidade resultantes foram plotados em esquemas ilustrativos, afim de se comparar os três perfis obtidos. Observou-se em todos os casos um fluxo em curto-circuito na região superior da zona de separação e logo abaixo desta, um fluxo descendente no sentido dos coletores ao fundo da unidade. Quando comparadas, apenas pequenas diferenças quanto à espessura da região de curto circuito superior foram verificadas entre as três situações abordadas, as quais não explicam as diferentes eficiências de clarificação obtidas na etapa I da pesquisa, relacionadas à concentração de ar fornecida à flotação. / The objectives of this study were to determine the influence of hydraulic surface loading of contact and separation zones and of the air micro bubbles concentration in the particle removal efficiency in flotation units applied to water treatment for public supply and also characterize the flow structure into the separation zone. The works were divided into two stages: the first included the operation of the pilot plant fed with synthetic water, using three values of hydraulic surface loadings in the separation zone associated with two hydraulic surface loadings in the superficial zone of contact, each one with three concentrations of air supplied to the flotation. Were kept fixed parameters: contact time in the contact zone, flocculation time, mean flocculation gradient and cross-flow velocity. The results of this step were monitored based on the removal efficiency of color and turbidity. The higher removal efficiencies, 87.5% of turbidity and 96.8% apparent color were obtained for the lower hydraulic surface loading of contact and separation zones studied, associated with air concentration of 4.90 g/\'CM POT.3\' of water. This, among other results, led to the conclusion that this air supplied to the flotation concentration always provided the lowest residual color and turbidity values, under the conditions investigated. As for the hydraulic surface loading in the contact zone, 136.3 m/h resulted in higher efficiencies for clarification and when increasing to 172.8 m/h slight drop in efficiency was caused. Finally, regarding separation zone hydraulic surface loading, the lowest rate (9.8 m/h) was the one in which the highest efficiencies of clarification were obtained, which decreased, as the hydraulic surface loading was increased. In the second step, the probe microADV was used to characterize the flow inside the separation zone. Characterizations were carried out for the three air concentrations supplied to the flotation studied on the first step, fixing contact zone hydraulic surface loading and time (136.3 m/h and 53 s, respectively), the separation zone hydraulic surface loading (12.3 m/h), the input flow and cross-flow velocity as step I. For the three conditions studied, we adopted a of two-dimensional virtual data collection grid with 98 equally spaced points, 14 in height and 7 parallel to the length. The data collection time at each point was 2 min with a sampling frequency of 50 Hz. The resulting velocity vectors were plotted on illustrative diagrams in order to compare the three profiles obtained. A short-circuit flow in the upper part of the separation zone and below this, a downward flow toward the bottom of the collector unit were observed in all cases. In comparison, only small differences in the thickness of the upper region of short circuit were observed between the three situations discussed, which do not explain the different efficiencies of clarification obtained in the first step of the research related to the air bubble concentration.

Page generated in 0.0525 seconds