271 |
Síntese e caracterização estrutural, mecânica e óptica de materiais compósitos restauradoresKAUFFMAN, Cynthia Macêdo Feijó 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T15:50:44Z (GMT). No. of bitstreams: 2
arquivo6671_1.pdf: 7283545 bytes, checksum: c3f7fe460c5381c8eb422f3598e3376b (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste trabalho foi avaliar a relação microestrutura e propriedade dos
materiais compósitos restauradores. Foram caracterizados três compósitos
comerciais, de micropartículas, de nanopartículas e microhíbrido, e um compósito
sintetizado em nossos laboratórios com oxoclusteres de titânio com grupos
metacrílicos coordenados. As características microestruturais dos compósitos
foram analisadas através da MEV, MET e EDS. A quantidade de carga inorgânica
foi verificada através da análise termogravimétrica. O grau de conversão foi
verificado por espectroscopia de infravermelho FTIR-ATR. As propriedades
mecânicas de resistência à fratura e módulo de elasticidade foram avaliados
através com teste de flexão de 3 pontos e a dureza com teste de microdureza
Vickers. Avaliaram-se também as propriedades ópticas dos compósitos através da
espectroscopia UV-VIS e tomografia por coerência óptica. Os compósitos
comerciais com nanopartículas e microhíbrido apresentaram propriedades
mecânicas superiores ao compósito de micropartículas. O compósito de
micropartículas apresentou menor quantidade de carga inorgânica 55% do que o
compósito microhíbrido e o de nanopartícula 72% e 77%, respectivamente. O
compósito comercial de nanopartículas apresentou maior resistência flexural,
maior módulo de elasticidade e maior grau de conversão enquanto que o
compósito microhíbrido obteve maior microdureza. A tomografia por coerência
óptica a 930 nm foi utilizada com aquisição de imagem em tempo real para avaliar
a propriedades ópticas e mecânicas dos compósitos. O coeficiente de atenuação
mostrou-se diferente para os diferentes compósitos. Os oxoclusteres de titânio
favoreceram o espalhamento da luz no interior do compósito. Como conclusão,
composição química, distribuição de tamanho, percentagem em peso e
organização das partículas inorgânicas de carga assim como tamanho médio das
partículas interferem nas propriedades dos materiais compósitos
|
272 |
Técnicas ópticas para caracterização e diagnóstico de sistemas biológicosJosé Rátiva Millán, Diego 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T17:35:00Z (GMT). No. of bitstreams: 2
arquivo5318_1.pdf: 9782284 bytes, checksum: 8aff4b29332b39f2f85206df9318dcd4 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No presente trabalho foram caracterizadas e exploradas as propriedades ópticas
lineares e não lineares de sistemas biológicos. A determinação dos aspectos básicos da
interação luz-biosistemas é essencial para o desenvolvimento de novas aplicações em
Biofotônica. Aqui, foram elaborados novos métodos ópticos para a caracterização e
diagnóstico de diferentes sistemas biológicos (aminoácidos e fungos). Em particular, foi
desenvolvida uma nova variação da técnica de Varredura Z, denominada de TMEZ
( Thermally managed eclipse Z-scan ). Com essa técnica, foram determinadas algumas
das propriedades ópticas não lineares de diferentes soluções de aminoácidos e biocolóides.
Também foi implementada a técnica de microscopia multifotônica de campo aberto. Com
esta técnica foi demonstrado que nanopartículas metálicas podem ser usadas como
instrumento para o aumento da intensidade de fluorescência de cromóforos celulares. A
análise da emissão fluorescente de biosistemas pode ainda ser explorada como ferramenta
para diagnóstico clínico. Com excitação por luz ultravioleta, a emissão de diferentes
fungos foi caracterizada e um novo dispositivo foi proposto para o auxilio do diagnóstico
dermatológico
|
273 |
Mantenabilidade de redes óticas sobre linhas de alta tensãoCosta de Oliveira, Cenildo 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T17:35:26Z (GMT). No. of bitstreams: 2
arquivo3469_1.pdf: 4223078 bytes, checksum: 06d62b511e7d0087d2feb5972ffd2bf6 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2009 / Companhia Hidroeletrica do São Francisco / A rede ótica baseada em cabos do tipo pára-raios, conhecidos como OPGW, foi a forma
como a CHESF Companhia Hidro Elétrica do São Francisco, utilizou para interligar suas
subestações ao longo da malha elétrica. Com o passar dos anos, alguns fenômenos, até então desconhecidos,
surgiram como desafios ao mantenedor dessa rede. O presente trabalho descreverá
os vários problemas que ocorrem nessa malha ótica e se ocupará em realizar um aprofundamento
num específico problema levantado. Nesse contexto, surgiu a necessidade de estudar e conceber
a criação de um modelo de manutenção que decida quais ações devem ser tomadas na solução
do problema conhecido como deslocamento de núcleo ótico, o qual atenua os sinais que trafegam
nessa rede. A concepção do modelo é precedida por uma decisão a ser tomada pelo proprietário
da malha ótica na escolha entre três cenários apresentados: continuar a dar manutenção na rede
com degradação óptica, trocar apenas os trechos com problema ou, por fim, trocar todo o trecho
de cabo com o potencial problema já anunciado de deslocamento de núcleo ótico. Uma vez
decidido qual caminho trilhar, discute-se o modelo de manutenção e as variáveis envolvidas na
problemática e como atuar
|
274 |
Análise sistêmica das penalidades de ruído nas redes ópticas transparentesPEREIRA, Helder Alves January 2007 (has links)
Made available in DSpace on 2014-06-12T17:35:26Z (GMT). No. of bitstreams: 2
arquivo6908_1.pdf: 3492088 bytes, checksum: 356e991b957a6cdc0580e965fdf503b6 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2007 / Nesta tese são estudados os processos de atribuição de comprimento de onda e o de roteamento
nas redes ópticas transparentes. Além de considerar os recursos da camada de rede (disponibilidade
de comprimentos de onda), avalia-se também o impacto da camada física na
transmissão dos sinais para ambos os casos. Quanto à atribuição de comprimento de onda, o
estudo visa a minimização do efeito da mistura de quatro ondas entre os sinais propagantes.
Os algoritmos exaustivo e genético são utilizados no estudo para comparação em termos de
desempenho computacional. O primeiro examina todas as possibilidades de alocações de
comprimentos de onda, enquanto que o segundo utiliza o processo evolucionário para encontrar
as possíveis soluções. Quanto ao roteamento, desenvolve-se um modelo analítico que
quantifica a degradação da relação sinal-ruído óptica ao longo da propagação do sinal. Os
efeitos físicos considerados são: o efeito da saturação do ganho e a emissão espontânea amplificada
produzida nos amplificadores ópticos, a interferência homodina nos comutadores
ópticos e a mistura de quatro ondas na fibra óptica. O efeito da dispersão por modo de polarização
também é considerado como penalidade temporal. O modelo analítico proposto é
aplicado para avaliação do desempenho das redes ópticas transparentes em termos da probabilidade
de bloqueio das chamadas, e em um algoritmo de roteamento
|
275 |
Aprendizagem ativa : uma proposta para o ensino de luz e som / Active learning : a proposal for the light and sound educationSantos, José Rafael dos 01 June 2016 (has links)
In this paper, we discuss the application of a teaching unit designed as a form of educational product, to help basic education teachers in the teaching of wave concepts. First, we applied questionnaires that seek a student relationship profile with the school, with teachers, with other classmates and the methodologies used in teaching and learning process, trying to understand what "mobilize". Next, we apply a pre-conceptions test of wave concepts and use a Potentially Significant Teaching Unit (PMTU) for development was employed twelve hours classes. In the development of the sequence, it is possible to use videos, simulations, Peer instructions (PI), problem-issues developed in Modellus and conceptual maps of logical and potentially significantly. The last stage of PMTU is the application of a post-test, whose answers were categorized as satisfactory, unsatisfactory and not answered it possible to compare the relationships established by students between the physical concepts before and after application, even without the use of scientific language, something likely in the pretest. We transform these qualitative data into quantitative, and to pre-test results (notapré) and posttest (notapós) it was possible to calculate the normalized gain in our class, the expression founded by quantitative analysis suggested by Hake (1998) but also we compare the results of qualitative way. As for the ratio of questionnaires were analyzed according to the Theory of Relation to Know Bernard Charlot (2005) by removing "central argument" of responses. The application of the product occurred in the State School Professor Josefa Marques, located in Redondo Well, with 12 students of the second year of high school. The results showed an improvement in the number of correct issues with the interaction between the students, as well as a normalized gain of 0.72 when comparing satisfactory answers the pretest and posttest. / Neste trabalho discutimos a aplicação de uma unidade de ensino, desenvolvida como forma de produto educacional, para auxiliar professores da educação básica no ensino de conceitos de ondulatória. Primeiramente, aplicamos questionários que buscam um perfil da relação do aluno com a escola, com os professores, com os outros colegas de classe e com as metodologias utilizadas no processo de ensino aprendizagem, tentando entender o que os “mobilizam”. Em seguida, aplicamos um pré-teste de concepções sobre conceitos de ondulatória e utilizamos uma Unidade de Ensino Potencialmente Significativa (UEPS), para desenvolvimento empregou-se doze horas aulas. No desenvolvimento da sequência é possível a utilização de vídeos, simulações, instruções por colegas (IpC), questões-problema desenvolvidas no Modellus e mapas conceituais de maneira lógica e potencialmente significativa. A última etapa da UEPS consiste na aplicação de um pós-teste, cujas respostas foram categorizadas em satisfatórias, insatisfatórias e não respondidas, isso possibilitou comparar as relações estabelecidas, por parte dos alunos, entre os conceitos físicos antes e depois da aplicação, mesmo sem a utilização de uma linguagem científica, algo bem provável no pré-teste. Transformamos esses dados qualitativos em quantitativos e, com os resultados do pré-teste (notapré) e do pós-teste (notapós) foi possível calcular o ganho normalizado, na nossa turma, pela expressão fundamentada pela análise quantitativa sugerida por Hake(1998), como também comparamos os resultados de maneira qualitativa. Já os questionários de relação foram analisados de acordo com a Teoria da Relação com o Saber de Bernard Charlot (2005), retirando “argumentos centrais” das respostas. A aplicação do produto ocorreu na Escola Estadual Professora Josefa Marques, situado na cidade de Poço Redondo, com 12 alunos do segundo ano do ensino médio. Os resultados apresentaram uma melhoria na quantidade de acertos das questões com a interação entre os alunos, como também um ganho normalizado de 0,72 ao comparar as respostas satisfatórias do pré-teste e do pós-teste.
|
276 |
Aplicação da tomografia por coerência óptica na avaliação do comprometimento da mucosa labial na esclerose sistêmicaPIRES, Natalia Sotero Machado 07 December 2016 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-06-18T20:43:48Z
No. of bitstreams: 1
DISSERTAÇÃO Natália Sotero Machado Pires.pdf: 2386467 bytes, checksum: 328cc87e77a900f43268a8780c32d15c (MD5) / Made available in DSpace on 2018-06-18T20:43:48Z (GMT). No. of bitstreams: 1
DISSERTAÇÃO Natália Sotero Machado Pires.pdf: 2386467 bytes, checksum: 328cc87e77a900f43268a8780c32d15c (MD5)
Previous issue date: 2016-12-07 / CNPQ / A esclerose sistêmica (ES) é uma desordem crônica do tecido conjuntivo caracterizada pela fibrose da pele, dos vasos sanguíneos e de alguns órgãos, geralmente diagnosticada em estágio avançado, a partir de manifestações clínicas, associadas a exames complementares. Diante deste quadro,faz-se necessária a utilização de novos métodos de diagnóstico que possam contribuir para a identificação precoce da patologia. Dessa forma, esse estudo teve por objetivo avaliar as características qualitativas e quantitativas da mucosa do lábio inferior utilizando a Tomografia por Coerência Óptica (OCT) e sua associação com parâmetros clínicos em pacientes com ES. Trata-se de um estudo clínico observacional com 68 voluntários: 33 portadores de ES (GES), que preencheram os critérios ACR/EULAR, 18 da forma cutânea limitada (FL) e 15 da difusa (FD), sendo 28 do sexo feminino com média de idade de 46,1 anos, recrutados do serviço de Reumatologia do HC-UFPE. O grupo controle (GC) foi constituído de 35 indivíduos saudáveis, sendo 28 do sexo feminino com média de idade de 39,2 anos. Todos eles foram submetidos a avaliação da mucosa labial inferior pelo OCT. As imagens passaram por um processamento computacional com o programa Matlab, medindo a densidade óptica, e medidas da espessura das camadas em µm e quantidade de pixel nos tons de cinza foram realizadas utilizando o ImageJ. Para análise estatística, os dados foram tabulados em Excel e analisados pelo SYSTAT 9.0 Version Demo, considerando o valor estatístico significante de p<0.05. Observou-se que a densidade óptica em 300 µm de profundidade foi maior nos pacientes com ES quando comparado com o GC (0.87 e 0.82, respectivamente), p=0.016. A espessura do epitélio da mucosa labial no GES e no GC foi de290.90µm e de 442.63 µm, respectivamente, com p<0.0001, e a quantidade de pixels encontrada no tom de cinza 96 da camada externa foi de 315.79 pixels (GES) e 576.71 pixels (GC), p<0.0001, e da camada total, 764.27 pixels(GES) e 1013.14 pixels (GC), p=0.0001. Não houve diferença estatística significante na espessura do epitélio obtida, pelo OCT entre as fases precoce e estabelecida nas formas FL (p=0.9) e FD (p=0.4), podendo-se inferir que, mesmo na fase precoce, independente da forma clínica, os pacientes já apresentam alterações no espessamento deste epitélio similar com as fases de diagnóstico estabelecido. Nas correlações com os parâmetros tempo de doença, forma clínica, escore de Rodnan modificado, fenômeno de Raynaud,úlceras digitais, doença pulmonar intersticial, hipertensão arterial pulmonar, disfunção esofagiana e envolvimento músculo esquelético, não foi encontrada associação estatística. Desta forma, conclui-se que a avaliação da mucosa com o OCT mostrou características que a difere entre os grupos GC e GES, e acredita-se que, em analogia com a utilização do escore de Rodnan modificado para determinação do espessamento da pele no diagnóstico precoce e resposta terapêutica da ES, a identificação do envolvimento da mucosa labial possa ser um método complementar com igual importância. / Systemic sclerosis (SSc) is a chronic connective tissue disorder characterized by fibrosis of the skin, blood vessels and some organs, usually diagnosed at an advanced stage, from clinical manifestations associated with complementary exams. In view of this situation, it is necessary to use new diagnostic methods that may contribute to the early identification of the pathology. The aim of this study was to evaluate the qualitative and quantitative characteristics of the inferior labial mucosa using Optical Coherence Tomography (OCT) and its association with clinical parameters in SSc patients. This is an observational clinical study with 68 volunteers: 33 SSc patients, who met the ACR/EULAR criteria, 18 of the limited cutaneous (lcSSc) and 15 of the diffuse cutaneous (dcSSc) forms, of which 28 were women with a mean aged 46.1 years, recruited from the HC-UFPE Rheumatology Department. The healthy control (HC) consisted of 35 healthy individuals, being 28 females with a mean age of 39.2 years. All of them underwent evaluation of the inferior labial mucosa by OCT. The images underwent computational processing with the Matlab program, measuring the optical density, and measurements of the thickness of the layers in μm and number of pixels in the shades of gray were performed using ImageJ. For statistical analysis, the data were tabulated in Excel and analyzed by the SYSTAT 9.0 Version Demo, considering the statistical significance of p<0.05.It was observed that the optical density at 300 μm depth was higher in SSc patients when compared to HC (0.87 and 0.82, respectively), p = 0.016.The thickness of the labial mucosa epithelium in SSc and HC was 290.90 μm and 442.63 μm, respectively, with p <0.0001, and the number of pixels found in the shade of gray 96 of the outer layer was 315.79 pixels (SSc) and 576.71 pixels (HC), p <0.0001, and the total layer, 764.27 pixels (SSc) and 1013.14 pixels (HC), p = 0.0001.There was no statistically significant difference in the thickness of the epithelium obtained by OCT between the early and established phases in the lcSSc (p = 0.9) and dcSSc (p = 0.4) forms, and it can be inferred that, even in the early phase, independent of the clinical form, patients already present alterations in the epithelium thickening similar with the established diagnostic phases. In the correlations with the parameters of disease duration, clinical form, modified Rodnan score, Raynaud phenomenon, digital ulcers, interstitial lung disease, pulmonary arterial hypertension, esophageal dysfunction and musculoskeletal involvement, no statistical association was found. Thus, it is concluded that the evaluation of the mucosa with the OCT showed characteristics that differ between HC and SSc groups, and it is believed that in analogy with the use of the modified Rodnan score to determine skin thickening in the early diagnosis and the therapeutic response of ES, the identification of the involvement of the labial mucosa may be a complementary method with equal importance.
|
277 |
Dependência angular de uma ressonância de transparência induzida eletromagneticamente em vapor atômicoCARVALHO, Paulo Renato Silva de 20 July 2004 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-07T22:16:13Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSEERTAÇÃO Paulo Renato Silva de Carvalho.pdf: 1687531 bytes, checksum: 292c07b43367f44e42fe88222bf5493b (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-15T21:49:35Z (GMT) No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSEERTAÇÃO Paulo Renato Silva de Carvalho.pdf: 1687531 bytes, checksum: 292c07b43367f44e42fe88222bf5493b (MD5) / Made available in DSpace on 2018-08-15T21:49:35Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSEERTAÇÃO Paulo Renato Silva de Carvalho.pdf: 1687531 bytes, checksum: 292c07b43367f44e42fe88222bf5493b (MD5)
Previous issue date: 2004-07-20 / CNPq / Neste trabalho, apresentamos um estudo teórico e experimental da dependência da largura da ressonância coerente, transparência induzida eletromagneticamente, com o ângulo entre os dois feixes envolvidos neste efeito, comumente conhecidos como feixes de prova e de acoplamento. Observamos que o não paralelismo dos feixes contribui fortemente para um alargamento da ressonância coerente, ainda que para pequenos ângulos da ordem de alguns miliradianos. Teoricamente, tratamos o problema da interação de um átomo de três níveis numa configuração
do tipo Λ, com os feixes de prova e de acoplamento, resolvendo a equação de Liouville que dá a evolução do estado atômico. Com isso, calculamos a coerência induzida no átomo pelos feixes incidentes e o espectro de absorção do feixe de prova, que exibe a ressonância coerente de transparência induzida eletromagneticamente. Experimentalmente, fizemos medidas sistemáticas da dependência angular e mostramos que nossos cálculos numéricos concordam qualitativamente com as observações experimentais. Propomos ainda uma possível aplicação dos nossos resultados para a medida da temperatura de amostras de átomos frios. / In this work, we present a theoretical and experimental study on the linewidth dependence of an Electromagnetically-Induced-Transparency resonance on the angle between the two beams involved in this effect, commonly known as the coupling and probe beams. We observed that the nonparallelism of the beams contributes strongly to a broadening of the coherent resonance, even for small angles on the order of a few milliradians. Theoretically, we treated the interaction of a three-level Lambda-type atom with the coupling and probe beams by solving Liouville’s equation, which describes the evolution of the atomic state. In this way, we calculated the light-induced atomic coherence and the probe beam’s absorption spectrum, which shows the Electromagnetically-Induced-Transparency resonance. Experimentally, we performed systematic measurements of the angular dependence and showed that our numerical calculations agree qualitatively with the experimental observations. Furthermore, we propose a possible application of our results for measuring the tem-perature of cold atomic samples.
|
278 |
Caracterização óptica de filmes finos de NbOx obtidos por sputtering reativo / Optical characterization of NbOx thin films obtained by reactive sputteringGuilherme Scheidt 02 December 2014 (has links)
Filmes finos de óxido de nióbio têm sido usados em muitas aplicações tecnológicas. Existem pelo menos três óxidos estáveis de nióbio: NbO, NbO2 e Nb2O5 e cada um deles tem propriedades específicas. O Nb2O5 é a forma termodinamicamente mais estável e apresenta propriedades físicas e químicas únicas, como alto índice de refração, band gap largo, excelente estabilidade química e resistência à corrosão, baixa absorção óptica no campo da luz visível até regiões próximas ao infra-vermelho, sendo amplamente utilizados como filtros de interferência óptica de alta qualidade. Neste trabalho foram depositados filmes de óxido de nióbio por meio da técnica de sputtering reativo sobre substratos de silício e borossilicato. Os filmes finos foram obtidos com vazão de oxigênio variando entre 15 e zero sccm. O objetivo deste trabalho foi a caracterização das propriedades ópticas dos filmes. Foram avaliados o índice de refração e a espessura pela técnica de elipsometria, o band gap pelo método de Tauc e a razão atômica e a densidade superficial por meio de Espectrometria de Retroespalhamento Rutherford (RBS). Foram obtidos espectros de transmitância e refletância por Espectrofotometria UV/Vis/NIR e o coeficiente de extinção foi calculado pelo método de Hong. Todos estes parâmetros são importantes para aplicação em dispositivos ópticos. Nos filmes depositados com vazão de oxigênio de 15 sccm foi observado que o índice de refração aumenta com o aumento da espessura dos filmes e que o composto formado foi Nb2O5. Para uma vazão de 2,0 sccm foi encontrado o composto NbO2 e o filme apresentou alta absorção ótica. Os resultados sugerem que outros óxidos de nióbio ou nióbio metálico foram incorporados nos filmes conforme o fluxo de oxigênio foi diminuído. Foi observada uma relação direta entre a diminuição da vazão de oxigênio durante a deposição e um aumento da quantidade de nióbio nos filmes, acompanhados de um aumento do índice de refração e da densidade superficial. / Niobium oxide thin films have been used in many technological applications. There are at least three stable niobium oxides: NbO, NbO2 and Nb2O5 and each one has specific properties. The Nb2O5 is the most stable thermodynamically form having unique physical and chemical properties such as high refractive index, wide band gap, excellent chemical stability and corrosion resistance, low optical absorption in the field of visible light to near the infrared regions, being widely used as high quality optical interference filters. In this work niobium oxide thin films were deposited by reactive sputtering technique on silicon and borosilicate substrates. The films were obtained by using oxygen flow rates varying from 15 up to zero sccm. The objective of this work was the optical characterization of niobium oxide films. The refractive index and the thickness were evaluated by ellipsometry technique, the band gap by TAUC method and the atomic ratio and the surface density by means of Rutherford backscattering spectrometry (RBS). Spectral transmittance and reflectance spectrophotometry by UV / Vis / NIR curves were obtained and the extinction coefficient was calculated by the method of Hong. All of these parameters are important for application in optical devices. In the films deposited with oxygen flow of 15 sccm it was observed that the refractive index increases with increasing thickness of the films and analyzes indicated that Nb2O5 forms for when a flow rate of 15 sccm is used. For a flow rate of 2.0 sccm it was found NbO2 and a high optical absorption. As the flow of oxygen used in the deposition of the films was decreased, there were signs that were incorporated in the films other oxides of niobium or niobium metal itself. A direct relationship between decreased of oxygen flow during deposition and a increase in niobium quantity in the films, accompanied by an increase in the refractive index and surface density was observed.
|
279 |
Diagnóstico de lesões da tireóide pela espectroscopia de absorção no infravermelho por transformada de Fourier-FTIR / Thyroid lesions diagnosis by fourier transformed infrared absorption spectroscopy (FTIR)Felipe Guimarães Albero 11 December 2009 (has links)
Os nódulos de tireóide constituem patologia comum, com uma incidência entre 4- 7% na população brasileira. Embora a punção aspirativa por agulha fina (PAAF) seja um método com boa sensibilidade, a discriminação entre lesões benignas e neoplasias malignas não é possível em todos os casos, permitindo a incidência de diagnósticos falsos-positivos, o que conduz a tireoideotectomia pelo risco de carcinoma. O escopo deste estudo foi verificar se a espectroscopia de absorção no infravermelho por transformada de Fourier (FTIR) pode contribuir no diagnóstico diferencial entre neoplasias malignas e benignas de tecidos e aspirados. Amostras de PAAF, homogenatos e tecidos de nódulos de tireóide com o diagnóstico histopatológico foram obtidos e preparados para análise espectroscópica por FTIR. As punções e homogenatos foram medidas por -FTIR (entre 950 1750 cm-1, com resolução de 4 cm-1 e 120 varreduras). As amostras de tecido foram analisadas diretamente pela técnica de ATR-FTIR, com resolução de 2 cm-1, 60 varreduras, região entre 950 1750 cm-1.. Todos os espectros foram corrigidos pela linha base e normalizados pela área sob a banda das amidas (1550-1640 cm-1) de modo a minimizar as variações de homogeneidade das amostras. Os espectros foram então convertidos em segundas derivadas usando-se o filtro de Savitzk-Golay com 13 pontos na janela. A variância de Ward e distância euclidiana foram usadas para se processar a análise de clusters. As amostras de PAAF revelaram um complexo padrão espectral. Todas as amostras mostraram alguns aglomerados de células ou grande concentração de hormônios, tendo representação em algumas bandas em 1545 e 1655 cm-1. Foram também encontradas bandas em torno de 1409, 1412, 1414, 1578 and 1579 cm-1, indicando a possível presença de açúcares, DNA e ácido cítrico de produtos metabólitos. Neste estudo, foi obtida uma excelente separação entre bócio adenomatoso e neoplasias malignas para as amostras de tecido, com 100% de sensibilidade em determinado cluster, mas 67% no geral e 50% de especificidade. Nos homogenatos e aspirados este valor foi menor (76,2% de sensibilidade e 52,6% de especificidade) porque incluiu outros tipos de lesões. Para uma maior diferenciação das amostras de PAAF de padrão folicular, um maior número de amostras se faz necessário. Os resultados deste estudo sugerem que a espectroscopia FTIR pode ser útil na diferenciação de carcinomas da tiróide em amostras de tecidos. / Thyroid nodules are a common disorder, with 4-7% of incidence in the Brazilian population. Although the fine needle aspiration (FNA) is an accurate method for thyroid tumors diagnosis, the discrimination between benign and malignant neoplasm is currently not possible in some cases with high incidence of false negative diagnosis, leading to a surgical intervention due to the risk of carcinomas. The aim of this study was to verify if the Fourier Transform infrared spectroscopy (FTIR) can contribute to the diagnosis of thyroid carcinomas and goiters, using samples of tissue and aspirates. Samples of FNA, homogenates and tissues of thyroid nodules with histopathological diagnosis were obtained and prepared for FTIR spectroscopy analysis. The FNA and homogenates samples were measured by -FTIR (between 950 1750 cm-1), at a nominal resolution of 4 cm-1 and 120 scans). Tissue samples were analized directly by ATR-FTIR technique, at a resolution 2 cm-1, with 60 scans in the same region. All spectra were corrected by the baseline and normalized by amides area (1550-1640 cm-1) in order to minimize variations of sample homogeneity. Then, spectra were converted into second derivatives using the Savitzk-Golay algorithm with a 13 points window. The Ward\'s minimum variance algorithm and Euclidean distances among the points were used for cluster analysis. Some FNA samples showed complex spectral pattern. All samples showed some cell pellets and large amount of hormone, represented by the bands of 1545 and 1655 cm-1. Bands in 1409, 1412, 1414, 1578 and 1579 cm-1 were also found, indicating possible presence of sugar, DNA, citric acid or metabolic products. In this study, it was obtained an excellent separation between goiter and malign lesion for the samples of tissues, with 100% of specificity in specific cluster and 67% sensibility and 50 of specificity. In homogenate and FNA samples this sensibility and specificity were lower, because among these samples, it were included many types of thyroid lesions. To obtain a more precise diagnosis for FNA of follicular thyroid the sample size should be increased. The results of this study suggest that FTIR spectroscopy may be useful for discriminate thyroid carcinomas from goiters in tissue samples.
|
280 |
Instrumentação eletrônica para pesquisas na área de ótica / Electronics system for optics research labsSilvio Antonio Tonissi Junior 16 March 1992 (has links)
Este trabalho consiste na elaboração de um conjunto de sistemas eletro-eletrônicos. aplicados principalmente na área de ótica, com a finalidade de se criar recursos tais que possibilitem a realização de experimentos com maior facilidade. confiabilidade e versatilidade. Ele está dividido em 2 partes principais. A primeira apresenta a construção de um sistema completo para acionamento de um laser de Argônio/Criptônio incluindo fonte de alimentação e cavidade ressonante com a utilização de um tubo importado. A segunda consta de um sistema de aquisição de dados baseado em um microcomputador da linha IBM-PC/XT-AT com um modulo para aquisição de pulsos rápidos, placa de interface para o microcomputador e software de controle. / This work describes the development of a electric-electronically system applied principally in the Optics area. Its purpose is to create the means such that experiments can be realized with greater facility, reliability and versatility. It is divided into two parts. The first introduces the construction of an Argon/Krypton laser system its power supply and the resonance cavity, with the use of an import tube. The second consists of a data acquisition system, based on an IBM-PC/XT-AT microcomputer, with a module for fast pulse acquisition, an interface board to the microcomputer and control software.
|
Page generated in 0.07 seconds