• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analys av kondensatorbatteriers tillkopplingsfenomen : Undersökning av de kopplingsfenomen som uppstår vid tillkoppling av kondensatorbatterier och deras påverkan på närliggande komponenter / Analysis of capacitor banks switching phenomena : Investigation of switching phenomena that occurs due to capacitor banks switching and their effects on surrounding components

Ezzeddine, Kassem, Oskarsson, Robert January 2017 (has links)
Många elektriska apparater är i behov av reaktiv effekt för att kunna fungera. Transport av reaktiv effekt tar onödig plats av den tillgängliga kapaciteten i elnätet, därför används kondensatorbatterier nära slutanvändaren för att generera reaktiv effekt. Därmed genereras och förbrukas den reaktiva effekten i en avskild del av nätet. Tillkoppling av kondensatorbatterier ger upphov till transienter som kan skada andra närliggande komponenter. Utifrån det verkliga ställverket Stallbacka i Trollhättan har denna rapport analyserat de transienter som uppstår efter tillkoppling av ett kondensatorbatteri inom mellanspänningsområdet. Analysen har innefattat hur stora transienterna blir efter olika förutsättningar och scenarier. Resultatet visade att transienterna i detta fall aldrig nådde upp till några allvarliga nivåer, och därmed klarade komponenterna sig med god marginal. Huruvida transienterna påverkar elkvaliteten är oklart, då det inte finns några definierade krav. Slutligen skulle ett beräkningsverktyg för förutspådda transienter tas fram. Beräkningsverktyget blev aldrig fullständigt på grund av den ohanterliga lösningen som erhölls. / Many electrical devices need reactive power to operate. Transmission of reactive power occupies a proportion of the available capacity in the power system and therefore capacitor banks are used near to the end user to generate reactive power. Thus, the reactive effect is generated and consumed in a separate part of the power system. Capacitor banks switching causes transients which may damage the surrounding components. Based on the real substation Stallbacka in Trollhättan, this study has analysed capacitor banks switching transients within the medium voltage level. The analysis has covered the size of these transients according to different conditions and scenarios. The result showed that the transients in this case never reached serious levels, thus there was no impact on the components. It is not clear whether the transients affect the power quality because there are no defined limits.  A calculation tool to the predicted transients was supposed to be created in the process. This calculation tool was never completed due to the unmanageable solution that was obtained.
2

Automatic overcurrent and leakage current sensing in multiple channel NMES systems

Otter, Malin, Jamal Pati, Bashar January 2023 (has links)
This report presents the development, implementation, and testing of a current monitor system that is specifically developed for testing a neuromuscular electrical stimulation system (NMES). The NMES system, developed by KTH and its academic and industrial partners Karolinska institute and Matrix Muscle Support, incorporates advanced features aimed at preventing cardiovascular diseases. The problem statement revolves around the necessity of developing a system capable of detecting any instances of overcurrent or leakage current in the neuromuscular electrical stimulation system. The purpose of this current monitoring system is to offer real-time monitoring of current levels within the electrical stimulation system. The project’s goal is to design and implement a comprehensive software and hardware solution that allows users to simultaneously monitor voltage levels across multiple channels and detect any abnormalities. The project was executed using a top-down approach. Each subtask is processed separately and finally tested to be verified and approved according to the expectations set. Test-driven development (TDD) methodology was employed to ensure the reliability and accuracy of the software and hardware implementation. The project has produced several significant results, the most important of which include the successful implementation of a real-time monitoring system for the multi-channel NMES system. A dedicated circuit board design has been prepared according to the specified requirements described in the report. The software interface has been designed to provide the user with real-time readings of voltage levels as well as visual identification of normal and abnormal values. The measurements carried out during all the tests gave clear answers to the set question, with the exception of some displacement (offset) which can be investigated more closely in future research. Furthermore, the reference images showed that the system was functioning in accordance with its original intended purpose. / Denna rapport presenterar utvecklingen, implementeringen och testningen av ett strömmätningssystem som är speciellt utvecklat för att testa ett neuromuskulärt elektriskt stimuleringssystem (NMES). NMES-systemet, utvecklat av KTH och dess akademiska och industriella partners Karolinska institutet och Matrix Muscle Support, innehåller avancerade funktioner som syftar till att förebygga hjärt-kärlsjukdomar. Problemformuleringen kretsar kring nödvändigheten av att utveckla ett system som kan detektera fall av överström eller läckström i det neuromuskulära elektriska stimuleringssystemet. Syftet med detta strömmätningssystem är att erbjuda realtidsövervakning av strömnivåer inom det elektriska stimuleringssystemet. Projektets mål är att designa och implementera en omfattande mjukvaru- och hårdvarulösning som tillåter användare att samtidigt övervaka spänningsnivåer över flera kanaler och upptäcka eventuella avvikelser. Projektet genomfördes med en top-down-metod. Varje deluppgift bearbetas separat och testas slutligen för att verifieras och godkännas enligt de förväntningar som satts. Testdriven utvecklingsmetod (TDD) användes för att säkerställa tillförlitligheten och noggrannheten hos implementeringen av mjukvara och hårdvara. Projektet har gett flera betydande resultat, av vilka de viktigaste inkluderar framgångsrik implementering av ett realtidsövervakningssystem för flerkanals NMES-systemet. En dedikerad kretskortsdesign har utarbetats enligt de specificerade kraven som beskrivs i rapporten. Mjukvarugränssnittet har utformats för att ge användaren realtidsavläsningar av spänningsnivåer samt visuell identifiering av normala och onormala värden. De mätningar som genomfördes under samtliga tester gav tydliga svar på frågeställningen, med undantag för viss förskjutning (offset) som kan undersökas närmare i framtida forskning. Vidare visade referensbilderna att systemet fungerade i enlighet med det ursprungliga syftet.

Page generated in 0.0507 seconds