• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 2
  • Tagged with
  • 45
  • 35
  • 20
  • 18
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Προηγμένο σύστημα ελέγχου λαπαροσκοπικού ρομποτικού εργαλείου

Πατέρας, Θωμάς 28 February 2013 (has links)
Η παρούσα διπλωματική εργασία πραγματεύεται την ανάπτυξη ενός αποδοτικού συστήματος ελέγχου που θα επιτυγχάνει τον ακριβή έλεγχο της θέσης ενός λαπαροσκοπικού ρομποτικού εργαλείου που χρησιμοποιεί ‘έξυπνα μορφομνήμονα κράματα’ ως τένοντες-επενεργητές. Το γεγονός ότι το εργαλείο που χρησιμοποιείται είναι με πλεονάζοντες βαθμούς ελευθερίας, καθιστά ιδιαίτερα δύσκολο πρόβλημα την επίλυση της αντίστροφης κινηματικής. Στόχος της παρούσας εργασίας είναι, μέσω τεχνικών υπολογιστικής όρασης, να επιλυθεί προσεγγιστικά η αντίστροφη κινηματική ανάλυση της θέσης των αρθρώσεων του ρομποτικού εργαλείου. Ο προτεινόμενος νόμος ελέγχου χρησιμοποιεί την αριθμητική επίλυση των γωνιών των αρθρώσεων από την αντίστροφη κινηματική για την επιτυχή παρακολούθηση της επιθυμητής τροχιάς του ρομποτικού εργαλείου. / This thesis deals with the development of a robust control system responsible for the precise position control of an innovative, SMA-based tendon-driven endoscopic robotic surgical tool. Given the hyper-redundant features of this robotic tool, the solution to the inverse kinematics problem is quite complicated. Henceforth, the main objective of this thesis is the numerical solution of the joints' positions using image processing techniques. The proposed control law utilizes this information for trajectory tracking purposes of the tool's end-effector.
42

Αλγόριθμοι ελέγχου κίνησης ηλεκτρομηχανικών συσκευών πολύ μικρής κλίμακας για την αποθήκευση πληροφορίας / Control architectures for MEMS-based storage devices

Πανταζή, Αγγελική 25 June 2007 (has links)
Οι ηλεκτροµηχανικές συσκευές αποθήκευσης δεδοµένων πολύ µικρής κλίµακας που βασίζονται στη χρήση ανιχνευτών (probes) αποτελούν ανερχόµενες εναλλακτικές επιλογές για τη βελτίωση της πυκνότητας αποθήκευσης, του χρόνου πρόσβασης των δεδοµένων και της απαιτούµενης ισχύος σε σχέση µε τις συµβατικές αποθηκευτικές συσκευές. Μία υλοποίηση µιας τέτοιας συσκευής χρησιµοποιεί θερµοµηχανικές µεθόδους για την αποθήκευση πληροφορίας σε λεπτές µεµβράνες πολυµερών υλικών. Σε αυτή την περίπτωση, η ψηφιακή πληροφορία αποθηκεύεται µε τη µορφή κοιλωµάτων πάνω στο πολυµερές υλικό, οι οποίες δηµιουργούνται από τις άκρες των ανιχνευτών διαµέτρου µερικών nm. Με στόχο την αύξηση του ρυθµού εγγραφής και ανάγνωσης χρησιµοποιούνται διατάξεις από ανιχνευτές που λειτουργούν παράλληλα, µε κάθε ανιχνευτή να εκτελεί λειτουργίες εγγραφής/ανάγνωσης/διαγραφής σε ξεχωριστό αποθηκευτικό πεδίο. Βασικές απαιτήσεις κατά τη λειτουργία τέτοιων συσκευών αποτελούν η εξαιρετικά µεγάλη ακρίβεια και η µικρή καθυστέρηση κατά τη µετακίνηση των ανιχνευτών πάνω από το πολυµερές υλικό. Η παρούσα διατριβή έχει ως αντικείµενο τη µελέτη των διατάξεων κίνησης και τη σχεδίαση πρωτότυπων αρχιτεκτονικών ελέγχου, που οδηγούν στη βελτίωση της απόδοσης των απαιτούµενων, σε συσκευές τέτοιου τύπου, λειτουργιών ελέγχου. Η µετατόπιση του αποθηκευτικού µέσου σε σχέση µε τη διάταξη των ανιχνευτών επιτυγχάνεται µε τη χρησιµοποίηση µικρής κλίµακας scanners, που έχουν δυνατότητες κίνησης σε δύο κατευθύνσεις (x/y). Πληροφορία για τη θέση του microscanner στις δύο κατευθύνσεις παρέχεται από θερµικούς αισθητήρες ανίχνευσης θέσης που κατασκευάζονται µαζί µε τη διάταξη µε τους ανιχνευτές και τοποθετούνται πάνω από το κινητό πλαίσιο. Η πλήρης κατανόηση της συµπεριφοράς των διατάξεων αυτών αποτελεί απαραίτητο στοιχείο για τον αποτελεσµατικό σχεδιασµό και την ανάλυση των συστηµάτων ελέγχου. Στα πλαίσια της διατριβής δηµιουργήθηκε ένα πλήρες µοντέλο της διάταξης του microscanner και των θερµικών αισθητήρων ανίχνευσης θέσης. Σύγκριση της απόκρισης του µοντέλου µε τις πειραµατικές µετρήσεις καταδεικνύει ότι το µοντέλο προσεγγίζει µε εξαιρετική ακρίβεια την απόκριση του συστήµατος. Το σύστηµα ελέγχου περιλαµβάνει, στην αρχή, τη λειτουργία αναζήτησης/ αποκατάστασης, κατά την οποία το σύστηµα εντοπίζει τη θέση όπου απαιτείται να πραγµατοποιηθεί εγγραφή ή ανάγνωση πληροφορίας µε εκκίνηση µία αυθαίρετη θέση του κινητού πλαισίου. Απαίτηση του συστήµατος κατά τη λειτουργία αυτή είναι η ελαχιστοποίηση του χρόνου πρόσβασης των δεδοµένων. Η γρήγορη πρόσβαση στα δεδοµένα αποτελεί µια σηµαντική πρόκληση στις συµβατικές αποθηκευτικές συσκευές. Με το πλεονέκτηµα των ελαφρύτερων µηχανικών µερών, οι υπό µελέτη συσκευές αποθήκευσης βασισµένες στην τεχνολογία MEMS θεωρούνται βασικές υποψήφιες για τη βελτίωση του χρόνου πρόσβασης των δεδοµένων. Οι σχετικές προοπτικές των συσκευών αυτών διερευνώνται αναλυτικά στα πλαίσια της διατριβής. Συγκεκριµένα, αρχικά µελετάται η απόδοση διαφόρων συστηµάτων µε βάση τη θεωρία ελέγχου βέλτιστου χρόνου. Τα αποτελέσµατα της µελέτης δίνουν το θεωρητικά βέλτιστο χρόνο πρόσβασης και την εξάρτησή του από τις παραµέτρους του κάθε συστήµατος. Στη συνέχεια, περιγράφεται η αρχιτεκτονική ελέγχου για τη λειτουργία αναζήτησης και παρουσιάζονται τα αποτελέσµατα που αντλήθηκαν από το περιβάλλον προσοµοίωσης και από την πειραµατική διάταξη. Τα αποτελέσµατα καταδεικνύουν ότι οι χρόνοι πρόσβασης των δεδοµένων που είναι δυνατό να επιτευχθούν µε τις συσκευές αυτές, είναι σηµαντικά µικρότεροι σε σχέση µε τις συµβατικές. Στη συνέχεια, ακολουθεί η λειτουργία παρακολούθησης, όπου η θέση των ανιχνευτών πρέπει να παραµένει στο κέντρο του επιθυµητού καναλιού, κατά τη διάρκεια εγγραφής/ανάγνωσης των δεδοµένων. Η απαίτηση για µεγάλη ακρίβεια στη µετακίνηση πάνω από τη νοητή γραµµή του κέντρου του καναλιού, της µίας ή περισσότερων κεφαλών που χρησιµοποιούνται κατά την εγγραφή/ανάγνωση, είναι σηµαντική για όλους τους τύπους αποθηκευτικών συσκευών. Οι απαιτήσεις για ακρίβεια γίνονται ακόµα πιο µεγάλες και κρίσιµες, στην περίπτωση των υπό µελέτη αποθηκευτικών συσκευών, όπου η ψηφιακή πληροφορία αποθηκεύεται σε µία περιοχή µε µέγεθος µερικών nm. Το σύστηµα ελέγχου, κατά τη λειτουργία αυτή, οφείλει να παρακολουθεί το επιθυµητό σήµα αναφοράς, και ταυτόχρονα να έχει ικανοποιητική απόρριψη των διαταραχών και να επιτυγχάνει την απαιτούµενη ακρίβεια ως προς τον προσδιορισµό της θέσης. Παράλληλα, σηµαντικό παράγοντα βελτιστοποίησης αυτής της λειτουργίας, αποτελεί ο ρυθµός εγγραφής/ανάγνωσης των δεδοµένων. Η πρώτη προσέγγιση για την αρχιτεκτονική ελέγχου, κατά τη λειτουργία αυτή, βασίζεται στην παρεχόµενη από τους θερµικούς αισθητήρες ανίχνευσης, πληροφορία της θέσης του microscanner. Η αρχιτεκτονική βασίζεται στον αλγόριθµο του γραµµικού τετραγωνικού ρυθµιστή (LQG) και η αξιολόγησή της γίνεται µε κριτήρια την ικανότητα παρακολούθησης της εισόδου, την απόρριψη των διαταραχών και την ακρίβεια ως προς τον προσδιορισµό της θέσης. Τα αποτελέσµατα που εξήχθησαν, κατά την υλοποίηση της αρχιτεκτονικής ελέγχου στην πειραµατική διάταξη, αναδεικνύουν ότι η αρχιτεκτονική πληρεί τις απαιτήσεις και η ακρίβεια µερικών nm που επιτυγχάνεται στον προσδιορισµό της θέσης επιτρέπει την αξιόπιστη εγγραφή και κατόπιν ανάγνωση δεδοµένων από την αποθηκευτική συσκευή. Μειονέκτηµα της παραπάνω προσέγγισης αποτελεί ο χαµηλής συχνότητας θόρυβος των θερµικών αισθητήρων, που επηρεάζει τη σωστή λειτουργία του κλειστού συστήµατος σε µεγάλες περιόδους λειτουργίας της συσκευής. Το πρόβληµα αυτό επιλύεται µε µία πρωτότυπη προσέγγιση που αναπτύχθηκε στα πλαίσια της διατριβής και βασίζεται στην πληροφορία, την προερχόµενη από τους θερµικούς αισθητήρες ανίχνευσης θέσης, σε συνδυασµό µε το προερχόµενο από το αποθηκευτικό µέσο σήµα σφάλµατος θέσης. Ο σχεδιασµός του συστήµατος ελέγχου, στην περίπτωση αυτή, εκµεταλλεύεται την εκ των προτέρων γνώση των χαρακτηριστικών θορύβου ως προς τη συχνότητα των δύο αισθητήρων ανίχνευσης θέσης, έτσι ώστε το σύστηµα ελέγχου που προκύπτει να χρησιµοποιεί την πιο αξιόπιστη µέτρηση σε κάθε περιοχή συχνοτήτων. Το πλαίσιο του σθεναρού ελέγχου, H∞, χρησιµοποιείται κατά το σχεδιασµό αυτής της αρχιτεκτονικής ελέγχου, µε διαχωρισµό ως προς τη συχνότητα. Με χρήση αυτής της µεθόδου, το σύστηµα ελέγχου δεν επηρεάζεται από τον χαµηλής συχνότητας θόρυβο των θερµικών αισθητήρων. Τα αποτελέσµατα που εξήχθησαν κατά την υλοποίηση της αρχιτεκτονικής ελέγχου στην πειραµατική διάταξη επιβεβαιώνουν τα παραπάνω. Η µέθοδος αυτή είναι πιο γενική και µπορεί να εφαρµοστεί σε κάθε πρόβληµα ελέγχου, που έχει δύο ή και περισσότερους αισθητήρες µε διαφορετικά χαρακτηριστικά απόδοσης σε διαφορετικές περιοχές συχνοτήτων. / Micro-electro-mechanical-system (MEMS)-based scanning-probe storage devices are emerging as potential ultra-high-density, low-access-time, and low-power alternatives to conventional data storage. One implementation of probe-based storage uses thermomechanical means to store and retrieve information in thin polymer films. Digital information is stored by making indentations on the thin polymer film with the tips of atomic force microscope (AFM) cantilevers, which are a few nanometers in diameter. To increase the data rate, an array of probes is used, in which each probe performs read/write/erase operations over an individual storage field. One of the primary challenges in building such devices is the extreme accuracy and the short latency required in the navigation of the probes over the polymer medium. This dissertation describes the design of novel control architectures and the characterization of their performance. The associated modelling effort, theoretical analysis, simulation work and experimental results are presented. Displacement of the storage medium relative to the array of cantilevers is achieved by using silicon-based micro-scanners with x/y-displacement capabilities. The x/y positional information can be provided by thermal position sensors that are fabricated on the cantilever-array chip and positioned directly above the scan table. A thorough understanding of the dynamics of these parts of the device is essential for effective design and analysis of the control architectures. In this dissertation a complete model of the micro-scanner and the thermal position sensors was developed. Comparison of the model response with the experimental data have shown that the model approximates the system response with an excellent accuracy. In general, the servo system in such a storage device has two functions. First, it locates the target track to which information is to be written or read back from, starting from an arbitrary initial position of the scan table carrying the storage medium. This is achieved by the so-called seek-and-settle procedure. The data access time depends on the duration of this operation, and therefore the minimization of its duration constitutes an important optimization factor. The speed of data access is a significant bottleneck in today’s computing systems. With the advantage of the lighter moving stage MEMS-based storage devices are widely touted to improve access times. In this dissertation these perspectives are examined in detail. Initially the time-optimal control theory has been studied for different system models and their performance has been examined regarding the optimal access time. The results of this study have provided the theoretically optimal access time for each model and its dependence on the system parameters. The control architecture for the seek operation has been designed. The simulation and experimental results show that the possible access times that can be achieved are significantly smaller than the conventional storage devices. The second function of the control system is to maintain the position of the read/write probes on the centre of the target track as they are being scanned along the length of this track during the normal read/write operation. This is achieved by the so-called track-follow procedure. Precise positioning and navigation of the read/write head(s) on the track centerlines is of paramount importance in all types of storage devices. The requirements become more crucial in the devices under study, where in order to achieve reliable storage and retrieval of data, accuracy in the order of a few nanometers in the scanner motion is needed. Therefore, the tracking of the reference signal, the disturbance rejection capabilities and the positioning resolution are considered as performance measures for the control system in this operation. Similarly, the read/write data rate constitutes an important optimization factor for this operation. The first approach of the control architecture for the track-follow procedure uses the position information from the thermal sensors. The control of the position in the x/y directions is realized using two independent feedback loops and each controller is based on the linear quadratic Gaussian regulator (LQG). For the evaluation of the proposed control architecture a detailed analysis has been performed in terms of the tracking performance, the disturbance rejection and the positioning resolution. The proposed architecture has been implemented in the experimental set-up and the analytical results are in agreement with those obtained experimentally. The experimental results show that the accuracy in the motion of the micro-scanner obtained with the proposed control architecture allows reliable storage and retrieval of data in the storage device. The disadvantage of the above control scheme originates from the low frequency noise of the thermal sensors that affects the closed loop performance for long term operation of the device. A novel control architecture was developed that addresses this problem by using medium-derived position information along with the thermal positioning sensor. The objective of this method is, using the a priori knowledge of the noise characteristics of the two sensors, to create a control structure that utilizes the best measurement in different frequency regions. The framework of the H∞ robust control was used for the design of this new frequency separated control architecture. Using this method the control system is not affected from the low frequency noise of the thermal sensors. The experimental results validate the performance of the proposed method. The developed methodology is more general and can be applied to any control problem that has two or more sensors with different performance characteristics in different frequency regions.
43

Μελέτη αρχιτεκτονικής υπηρεσιών-QoS πάνω σε τηλεπικοινωνιακά δίκτυα νέας γενιάς (NGN) (με χρήση εξομοιωτή OPNET)

Ανδριοπούλου, Φωτεινή 20 October 2010 (has links)
Οι οικονομικές και τεχνολογικές εξελίξεις των τελευταίων ετών, η απελευθέρωση της αγοράς, οι ισχυρές κατά απαίτηση πολυμεσικές υπηρεσίες καθώς και ο αυξημένος αριθμός χρηστών των κινητών δικτύων υποδεικνύουν την αναγκαιότητα της σύγκλισης των δύο δικτυακών τεχνολογιών (κινητή τηλεφωνία και internet) με στόχο την παροχή υπηρεσιών Internet στο περιβάλλον των κινητών επικοινωνιών. Η παραπάνω απαίτηση οδήγησε στην δημιουργία του δικτύου επόμενης γενιάς NGN. Η διπλωματική αυτή εργασία ασχολείται με την μελέτη της αρχιτεκτονικής του επιπέδου υπηρεσιών και την υποστήριξη Ποιότητας Υπηρεσίας (QoS) σε δίκτυα Νέας Γενιάς. Συγκεκριμένα δίνεται έμφαση στις λειτουργίες ελέγχου, σηματοδοσίας και λειτουργιών αρχιτεκτονικής του QoS σε επίπεδο υπηρεσιών. Αρχικά, ορίζουμε την έννοια “QoS” όσον αφορά την οπτική του δικτύου και το χρήστη. Περιγράφονται η αρχιτεκτονική του στρώματος υπηρεσιών του δικτύου καθώς και οι λειτουργίες ελέγχου πόρου και αποδοχής των κλήσεων, που αποτελούν σημαντικό μέρος της αρχιτεκτονικής του NGN. Στη συνέχεια παρουσιάζονται αρχιτεκτονικές που προορίζονται για την παροχή του QoS (IntServ, DiffServ), στη Συμφωνία Στάθμης Παρεχόμενης Υπηρεσίας (SLA), το πρωτόκολλο σηματοδοσίας COPS. Επίσης, δίνουμε έμφαση σε ορισμένες πτυχές (χρονοδρομολόγηση, διαχείριση ουρών) μίας QoS αρχιτεκτονικής, οι οποίες είναι ζωτικής σημασίας όσον αφορά την αποδοτική παροχή Ποιότητας Υπηρεσίας. Στη συνέχεια, με τη χρήση του εργαλείου προσομοίωσης OPNET, διεξάγουμε μια σειρά προσομοιώσεων σε ένα ATM και σε ένα NGN δίκτυο. Τέλος, παραθέτουμε και αναλύουμε τα αποτελέσματα των προαναφερθέντων πειραμάτων. / The concept of an NGN (Next Generation Network) has been introduced to take into consideration the new realities in the telecommunications industry, characterized by factors such as: competition among operators due to ongoing deregulation of markets, explosion of digital traffic, e.g.,increasing use of "the Internet", increasing demand for new multimedia services, increasing demand for a general mobility, convergence of networks and services, etc. This thesis has as subject the architecture of service stratum and presents an overview of standards functions defining the Quality of Service (QoS) in Next Generation Networks (NGNs). Several standards bodies define the QoS control architectures based on their scope of work. Specifically, emphasis is given to control functions, signalling and functional architecture of QoS in service stratum. Firstly, we define the meaning of QoS according to the view of the operator’s network and terminal users. The functional architecture of service stratum and especially the part of resource and admission control functions are described in the main body. Furthermore, architectures as IntServ and DiffServ, SLAs and COPS protocol are used as providers of the QoS. Scheduling and queuing management are necessary to optimize the QoS in NGN networks. In this project, we use OPNET simulator in two scenarios to determine construct and control ATM and NGN networks. Finally, collect the results of the experiments and analyze them.
44

Επαγωγική ζεύξη ισχύος για ενεργά εμφυτεύσιμα ιατροτεχνολογικά προϊόντα / Inductively coupled power systems for active implantable medical devices

Αθανασόπουλος, Παναγιώτης 19 April 2010 (has links)
Στην παρούσα διπλωματική εργασία αναζητείται ένας αυτόματος τρόπος ελέγχου, του επιπέδου της εκπεμπόμενης ισχύος προς το εσωτερικό του ανθρωπίνου σώματος. Εκεί μέσα βρίσκεται κάποιο ενεργό ιατροτεχνολογικό εμφύτευμα. Αυτό το εμφύτευμα στην περίπτωση της εργασίας αυτής, ήταν μία κάψουλα που καταγράφει με φωτογραφίες το γαστρεντερικό σύστημα καθώς οι περισταλτικές κινήσεις του εντέρου προωθούν την κάψουλα προς την έξοδο. Οι φωτογραφίες μεταδίδονται προς καταγραφικό που βρίσκεται έξω από το σώμα με ασύρματο τρόπο. Όπως καταλαβαίνουμε η κάψουλα αυτή αλλά και οποιοδήποτε άλλο ενεργό ιατροτεχνολογικό εμφύτευμα έχει ενεργειακές ανάγκες για την απρόσκοπτη λειτουργία του. Αυτές οι ανάγκες καλύπτονται με ασύρματη μετάδοση ενέργειας. Οι καινοτομίες που υπάρχουν σ’ αυτήν την εργασία είναι οι εξής: 1. Όσον αφορά το εξωτερικό τροφοδοτικό χρησιμοποιήθηκε ένας αντιστροφέας συντονισμού κλάσης D 2. Το πιο καινοτόμο στοιχείο είναι η δημιουργία κλειστού βρόχου ελέγχου μεταξύ του εξωτερικού τροφοδοτικού και του εμφυτεύματος ώστε αυτό να λαμβάνει την ποσότητα της ενέργειας που χρειάζεται κάθε στιγμή. 3. Επίσης σημαντικό είναι ότι η μετάδοση πληροφορίας από το εμφύτευμα προς τα έξω δεν γίνεται με μία ξεχωριστή συχνότητα αλλά χρησιμοποιώντας αρχές παθητικής τηλεμετρίας. Η εργασία αυτή πέρα από την θεωρητική προσέγγιση υλοποιήθηκε και πρακτικά σε εργαστήρια του πανεπιστημίου KUL (ESAT MICAS) στο Βέλγιο. Ο Βρόγχος ελέγχου λειτούργησε και πολλά συμπεράσματα εξάχθηκαν για περεταίρω βελτιώσεις. Η δομή του παρόντος πονήματος είναι ως εξής: Μετά την αρχική εισαγωγή το δεύτερο κεφάλαιο μας δίνει ένα θεωρητικό υπόβαθρο για την ασύρματη μετάδοση ενέργειας. Στη συνέχεια τα διάφορα μέρη των ηλεκτρονικών κυκλωμάτων που αναπτύχθηκαν αναλύονται διεξοδικά στα επόμενα κεφάλαια. Τέλος καταγράφονται τα συμπεράσματα και προτείνονται πιθανές βελτιώσεις για το μέλλον. / In this diploma thesis a way to have an automated control of the transmitted power level into the human body is sought. Inside the body there is an active medical implant. This implant in the case of this project is a swallowable capsule-camera that captures images along the GI tract as the peristaltic propulusion of the bowel push the capsule towards the exit. The photos are transmitted wirelessly to a special recording device that is located out of the body. It is obvious that not only this capsule but any other active medical implant needs energy to operate uninterrupted. This necessary energy is given through inductive power transmission. Innovations in this project are these: 1. The power supply outside the body is realized with Class-D resonant inverter topology. 2. The most innovative is the effectuation of closed control loop between the outer power supply and the implant in order to be received from the implant the exact amount of power that is needed every instant. 3. Also significant is that the transmission of data from the implant to the controlled power supply is not be done with a different carrier but using passive telemetry principles. Beyond the theoretic approximation that was made for this project, it was also realized in KUL university laboratories (ESAT MICAS) in Belgium. The closed control loop functioned properly and conclusions for further development are inferred. The structure of this diploma thesis is as follows: After the starting introduction the theoretic background for wireless inductive power transmission is given in chapter 2. Following, the different parts of the electronic circuits that were developed are analyzed comprehensively in next chapters. Finally conclusions are registered and future improvements are proposed.
45

Ανάλυση και έλεγχος γραμμικών και μη γραμμικών συστημάτων με περιορισμούς μέσω πολυεδρικών συναρτήσεων Lyapunov

Αθανασόπουλος, Νικόλαος 05 January 2011 (has links)
Το αντικείμενο της διατριβής αφορά την ανάλυση και τον έλεγχο δυναμικών συστημάτων με περιορισμούς στο διάνυσμα της εισόδου ή/ και στις μεταβλητές κατάστασης. Τα θεωρητικά εργαλεία που χρησιμοποιήθηκαν για την εξαγωγή των αποτελεσμάτων προέρχονται από τη θεωρία ευστάθειας Lyapunov, την αρχή σύγκρισης συστημάτων και τη θεωρία συνόλων, και οδήγησαν στην εδραίωση συνθηκών ευστάθειας και την ανάπτυξη συστηματικών μεθόδων εύρεσης λύσης στο πρόβλημα ελέγχου συγκεκριμένων κατηγοριών δυναμικών συστημάτων με περιορισμούς. Πιο συγκεκριμένα, για την κατηγορία των γραμμικών συστημάτων συνεχούς και διακριτού χρόνου, προτάθηκε μια νέα μέθοδος επίλυσης του προβλήματος ευσταθειοποίησης συνόλου αρχικών συνθηκών και του υπολογισμού του μέγιστου θετικά αμετάβλητου ή αμετάβλητου με έλεγχο συνόλου παρουσία περιορισμών στις εισόδους ή/και στις καταστάσεις. Τα αποτελέσματα επεκτάθηκαν και στην κατηγορία των γραμμικών συστημάτων με πολυτοπικη αβεβαιότητα. Επίσης, μελετήθηκε η κατηγορία των αυτοανάδρομων μοντέλων κινούμενου μέσου όρου (ARMA models). Αρχικά εδραιώθηκαν συνθήκες που εγγυώνται ευστάθεια για ένα συγκεκριμένο σύνολο αρχικών συνθηκών παρουσία περιορισμών. Τα αποτελέσματα αυτά εφαρμόστηκαν στην κατηγορία των δικτυωμένων συστημάτων ελέγχου (NCS), όπου υπολογίστηκε ένας κοινός γραμμικός νόμος ελέγχου ανατροφοδότησης κατάστασης για όλο το εύρος της καθυστέρησης της εισόδου. Τέλος, μελετήθηκε η κατηγορία των διγραμμικών συστημάτων συνεχούς και διακριτού χρόνου. Αρχικά διατυπώθηκαν ικανές συνθήκες ύπαρξης πολυεδρικών συναρτήσεων Lyapunov για αυτήν την κατηγορία συστημάτων. Το πρόβλημα που μελετήθηκε είναι η ευσταθειοποίηση μιας συγκεκριμένης περιοχής του χώρου κατάστασης παρουσία περιορισμών στις εισόδους και τις καταστάσεις και προτάθηκε μια υποβέλτιστη λύση που οδηγεί στον υπολογισμό γραμμικού νόμου ελέγχου ανατροφοδότησης κατάστασης. Όλα τα αποτελέσματα προκύπτουν από την επιλογή πολυεδρικών συναρτήσεων Lyapunov οι οποίες οδηγούν στο χαρακτηρισμό πολυεδρικών εκτιμήσεων της περιοχής ελκτικότητας και θετικά αμετάβλητων συνόλων. Τα κυριότερα οφέλη της επιλογής τέτοιων συναρτήσεων είναι η μη συντηρητική εκτίμησης της περιοχή ευστάθειας και η εδράιωση συνθηκών που οδηγούν σε συστηματικές μεθόδους επίλυσης των προβλημάτων ανάλυσης και ελέγχου, η λύση των οποίων προκύπτει από τη λύση γραμμικών προβλημάτων βελτιστοποίησης. / This dissertation considers the problem of stability analysis and control of dynamical systems under constraints in the input and/or state vector. The theoretical tools used arise from Lyapunov stability theory, comparison systems theory and set theoretic methods and lead to the determination of stability conditions and development of systematic methods that solve the control problem of constrained systems of particular type. In specific, for linear discrete or continuous time systems, a novel method that leads to the solution of the initial condition set stabilization problem as well as the maximal controlled invariant set computation problem is presented. These results have been extended for the case of linear systems with polytopic uncertainty. Also, the category of auto regressive moving average (ARMA) models is investigated. First, conditions that guarantee stability for a preassigned initial conditions set for constrained ARMA models are established. These results are applied to the category of networked control systems (NCS), were a single linear state feedback control law is computed for the whole range of the input delay. Finally, the category of bilinear discrete-time or continuous-time systems is investigated. Initially, sufficient conditions which guarantee existence of polyhedral Lyapunov functions are presented. The problem studied here is the stabilization of an initial condition set in the presence of input and state constraints. The solution proposed is suboptimal and leads to the determination of a linear state feedback control law. The choice of Lyapunov functions leads to the determination of a polyhedral approximation of the domain of attraction as well as polyhedral positively invariant sets. The main benefits of choosing this type of functions is the nonconservative estimation of the domain of attraction and the establishment of stability conditions that lead to systematic control design methods through the solution of linear programming problems.

Page generated in 0.0317 seconds