• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 319
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 324
  • 324
  • 212
  • 198
  • 27
  • 21
  • 20
  • 19
  • 18
  • 17
  • 17
  • 16
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Análise comparativa de exposição do operador à radiação entre as técnicas radial, femoral e radial com dispositivo protetor em procedimentos de cardiologia intervencionista / Comparative analysis of operator exposure to radiation among the radial, femoral and radial with protective device techniques in interventional cardiology procedures

Bienert, Igor Ribeiro de Castro [UNESP] 26 January 2016 (has links)
Submitted by IGOR RIBEIRO DE CASTRO BIENERT (bienert@terra.com.br) on 2016-01-29T14:19:19Z No. of bitstreams: 2 Tese Igor R C Bienert versao final para arquivamento.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Bienert_et_al BMJ Innovations.pdf: 1803372 bytes, checksum: 31c4180b21a1482a1a0afcc7856c9b78 (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Foram submetidos 2 arquivos PDF’s, apenas 1 arquivo deve ser submetido (o que contém a Tese ou Dissertação) Corrija estas informações e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-02-02T12:39:46Z (GMT) / Submitted by IGOR RIBEIRO DE CASTRO BIENERT (bienert@terra.com.br) on 2016-02-19T20:50:56Z No. of bitstreams: 2 Tese Igor R C Bienert versao final para arquivamento.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Bienert_et_al BMJ Innovations.pdf: 1803372 bytes, checksum: 31c4180b21a1482a1a0afcc7856c9b78 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-02-23T13:21:58Z (GMT) No. of bitstreams: 1 bienert_irc_dr_bot.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) / Made available in DSpace on 2016-02-23T13:21:58Z (GMT). No. of bitstreams: 1 bienert_irc_dr_bot.pdf: 2600270 bytes, checksum: 99be667aca0d1c9255e8b1f9002d9a85 (MD5) Previous issue date: 2016-01-26 / Introdução: A cardiologia intervencionista requer necessariamente um acesso vascular invasivo, sendo esta via de acesso uma escolha do médico operador. Nesta escolha interfere o tipo de procedimento, impacto ao paciente, risco ao profissional e experiência técnica. O acesso via artéria femoral é o mais difundido globalmente e a técnica de acesso pela artéria radial tem sido progressivamente adotada devido ao maior conforto para o paciente, menores taxas de complicações e em alguns cenários, de mortalidade. Um dos focos de interesse crescente é a exposição à radiação ionizante e medidas para minimizar o risco ao paciente e ao profissional. Escassa é a literatura disponível na área e conflitantes são seus resultados. Objetivo: Avaliar os níveis de radiação recebidos pelo médico operador de acordo com as diferentes técnicas de acesso, bem como mapear áreas de escape de radiação. Após essa etapa, o estudo visou desenvolver e validar dispositivo de radioproteção dedicado à técnica radial (TRIPTable) voltado à redução da radiação ao médico operador, comparando o seu impacto à técnica femoral e radial padrão no cenário de pacientes portadores de síndrome coronária aguda randomicamente alocados para cateterismo com intenção de tratamento percutâneo. Métodos: A fase inicial pré-clínica do estudo foi constituída de avaliação em ambiente controlado dos níveis de radiação em pontos pré-especificados de um operador simulado com phantom de água. A fase clínica do estudo foi um ensaio clínico prospectivo, randomizado, unicêntrico, comparativo entre três grupos denominados técnica femoral, técnica radial e técnica radial com dispositivo radioprotetor TRIPTable, recrutados no Hospital das Clínicas de Marília (Marília/SP) e randomizados na proporção 1:1:1 (108 pacientes - 36 por grupo) avaliando a radiação recebida pelo operador em três diferentes pontos (gônadas, tireoide e olhos). Os resultados foram comparados com o grupo controle de 108 pacientes provenientes de coorte randomizada externa entre técnica radial e femoral 1:1, utilizando critérios similares, porém com operadores cegos aos objetivos de avaliação de radiação visando detecção de vieses de técnica (efeito Hawthorne) e validação de resultados. Resultados: Não houve diferença entre o estudo e a coorte externa ou entre os grupos do estudo quanto a características clínicas, desfechos dos procedimentos ou parâmetros de exposição radiológica ao paciente. Os resultados indicam maior radiação recebida pelo operador com a técnica radial (12,5 mSv), seguida da femoral (10,1 mSv) e TRIPTable (6,8 mSv). Em relação aos locais de exposição, o território de gônadas teve maior sensibilidade radiológica com uso da técnica radial (p=0,001). Com uso da técnica femoral não houve diferença entre os três territórios (p=0,398), porém na análise ad hoc o território de gônadas foi mais sensível quando comparado à exposição aos olhos (p=0,016) e limítrofe em comparação à tireoide (p=0,056). No grupo do dispositivo TRIPTable não houve diferença significativa entre qualquer um dos territórios analisados (p=0,180). Conclusões: O estudo indica equivalência entre os resultados do procedimento entre os grupos e quanto à exposição radiológica ao paciente. Contudo, demonstrou maior impacto radiológico para o operador que utilizou a técnica radial, em comparação à técnica femoral e à técnica radial com uso do dispositivo TRIPTable. O uso do dispositivo reduziu o impacto radiológico comparado ainda à técnica femoral. Tais diferenças derivaram primordialmente da variação em território de gônadas. Os achados demonstram um campo de exposição radiológica heterogêneo ao corpo do operador, benefício do dispositivo testado e oportunidade de novas formas de desenvolvimento de medidas de radioproteção. Registros: UTN/OMS - U1111-1158-8591 Plataforma Brasil - CAAE 32767514.0.1001.5413 Clinical Trials - NCT 02200783. / Background: Interventional cardiology requires an invasive vascular access, a choice of medical operator. This choice is affected by type of procedure, patient impact, professional risk and technical experience. Interventional procedures via radial technique have progressively increased due to improved patient comfort, lower complication rates, and reduced mortality in some scenarios. One area of interest is radiation exposure and ways to minimizing it. Most studies focusing on patient radiation risk demonstrated conflicting results, and there is no consensus for increased exposure with any technique. Objective: The aim of this study was to evaluate radiological exposure under controlled radial and femoral access simulation tests, mapping radiation paths. After this stage, the study developed a radiological protection device for the transradial technique (TRIPTable), comparing its impact as compared to standard femoral and radial techniques in the setting of patients with acute coronary syndrome randomly assigned for catheterization with intent to percutaneous treatment. Methods: Radiation exposure was simulated under controlled conditions for femoral and radial techniques using a pressurized ionization chamber and water phantom. Different measurement points were defined according to standard positions to simulate radiation received by the operator in the gonads, thyroid, and eyes at different angles during real procedures. The clinical phase of the study is a prospective clinical trial, single-center, randomized, and comparing three groups (femoral technique, radial technique, and radial technique with radioprotective device), admitted in the Emergency Department of Hospital das Clinicas de Marilia (Marilia / SP – Brazil). Patients were randomized in a 1:1:1 proportion (108 patients - 36 per group) evaluating the radiation received by the operator measured by dosimetry at three different points (gonads, thyroid and eyes). As it is impossible to blind operators to study techniques, the results were compared to an external control cohort of patients including 108 individuals with similar inclusion and exclusion criteria, randomized for radial and femoral technique, but with blinded operators to radiation objectives, aiming technical bias detection (Hawthorne effect) and validation of results. Results: There was no difference between groups regarding clinical characteristics, procedures or patient radiation exposure outcomes. The results indicate higher radiation received by the operator with the radial technique (12.5 mSv) as compared to femoral technique (10.1 mSv) and TRIPTable technique (6.8 mSv). Regarding exposure locations, the gonad region had a higher radiation sensitivity with radial technique (p=0.001). With femoral technique there was no difference between the three territories (p=0.398) but the ad hoc analysis indicated higher radiosensibility in gonads when compared to eyes exposure (p=0.016) and borderline compared to thyroid exposure (p=0.056). In the TRIPTable device group there was no significant difference between any of the territories analyzed (p=0.180). Conclusions: The study indicates no difference of radiation exposure to the patients between the groups. However, there was a greater radiologic impact to the operator who used the radial technique, compared to the femoral technique and TRIPTable device technique. The device reduced the radiological impact even compared to the femoral technique. Such differences derived primarily from variation in gonads exposure. The findings demonstrate a heterogeneous radiation exposure to the operator body, device benefit and an opportunity to develop new ways to improve radiation protection. Registration: UTN/OMS - U1111-1158-8591 Plataforma Brasil - CAAE 32767514.0.1001.5413 Clinical Trials - NCT 02200783.
182

Investigação dos efeitos das impurezas alcalinas e hidrogênio no quartzo submetido à eletrodifusão e radiação ionizante

Rosa, Rafael Augusto dos Anjos [UNESP] 26 June 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-26Bitstream added on 2015-01-26T13:30:46Z : No. of bitstreams: 1 000801981.pdf: 983064 bytes, checksum: 453874979a1b747ca1d5c8ade2e5e0aa (MD5) / No presente trabalho, investigaram-se os efeitos dos íons alcalinos Na+, Li+ substituídos pelo íon H+ e Na+ nos centros relacionados ao alumínio que é uma impureza encontrada naturalmente nas matrizes de quartzo natural. Foram realizadas medidas de absorção óptica na região do visível e do ultravioleta, assim como medidas no infravermelho de amostras de quartzo natural que passaram ou não pelo processo de eletrodifusão. Foi investigado um efeito de escurecimento no quartzo citrino quando este é exposto ao sol, correlacionando com os centros estudados no presente trabalho, [AlO4/H], [Li-OH] e [Na-OH], identificáveis na região do infravermelho e os centros [AlO4]0 e E’ identificáveis no espectro de absorção óptica. A existência desses centros, chamados de centros de impurezas, é facilitada pela presença de um canal estrutural no quartzo, o qual permite a entrada de íons substitucionais como Al3+ e intersticiais Na+, Li+ e H+ junto a cadeia cristalina do quartzo. As amostras foram submetidas à radiação gama de dose aproximada a 20kGy, o resultado foi analisado com base nos centros estudados e os efeitos da eletrodifusão foram analisados por espectroscopia na região do UV-Vis e Infravermelho. A análise infravermelha indicou que a eletrodifusão de hidrogênio no quartzo citrino e hialino foi bem sucedida, uma vez que observa-se um incremento no centro [AlO4/H]0 e um decréscimo no centro [Li-OH], localizado na banda em 3484cm-1. A interação entre a radiação gama e o quartzo faz com que os centros relacionados à presença de hidrogênio com o alumínio aumentem, pois, a radiação ao excitar os átomos da rede do quartzo acaba por afetar diretamente os centros cujo compensador de carga são os átomos alcalinos Li+,Na+ e K+ do centro [AlO4/M]0, havendo então a compensação por átomos de hidrogênio, formando então mais centros [AlO4/H]0. O aparecimento das bandas em 430 ... / In the present study, we investigated the effects of alkali ions Na+ , Li+ replaced by ion H+ and Na+ in the center related to the aluminum that is a found naturally in motrices natural quartz. Measurements of optical absorption in the visible and ultraviolet region and measures infrared samples of natural quartz that have passed or not by electrodiffusion process were performed. An effect of browning in citrine quartz was investigated when exposed to the sun , correlating with the centers studied in this work, [ AlO4/H]0 , [ Li-OH ] and [Na-OH] , identifiable in the infrared region in the centers [AlO4]0 and E’ that are identifiable in the optical absorption spectrum. The existence of such centers, centers called impurities is facilitated by the presence of a structural channel quartz, which allows the entry of ions such as substitutional Al3+ substitutional and interstitial as Na+, Li+ and H+ along the crystal quartz chain . The samples were submitted to gamma radiation dose of approximately 20kGy , the outcome was analyzed based on the centers and the effects of electrodiffusion were analyzed by spectroscopy, UV- Vis and IR region. Infrared analysis indicated that the hydrogen electrodiffusion in citrine and hyaline quartz was successful , since there is an increase in the center [AlO4/H]0 and a decrease in the [Li-OH] , located in the band at 3484cm -1. The interaction between gamma radiation and quartz causes the centers related to the presence of hydrogen with aluminum increase , because the radiation to excite the atoms of the quartz network ultimately directly affect the centers whose compesator load are the alkali atoms Li+ , Na+ and K+ center [AlO4/M]0 , then there is compensation for hydrogen atoms , thus forming more centers [AlO4/H]0 . The appearance of bands at 430 and 620 nm associated to the center [AlO4]0 in the citrine and hyaline quatz after irradiation, enables us to state that ...
183

Radiação eletromagnética e Radioatividade : uma abordagem em aulas de Química do Ensino Médio em busca da (re)significação do conhecimento dos alunos

Furtado, Liliane Pereira 26 August 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Programa de Pós-Graduação em Ensino de Ciências, Mestrado Profissional em Ensino de Ciências, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-12-20T14:42:52Z No. of bitstreams: 1 2016_LilianePereiraFurtado.pdf: 1796759 bytes, checksum: 8d93ce87199656a98bba6ba298e0e8a5 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-02-03T21:34:36Z (GMT) No. of bitstreams: 1 2016_LilianePereiraFurtado.pdf: 1796759 bytes, checksum: 8d93ce87199656a98bba6ba298e0e8a5 (MD5) / Made available in DSpace on 2017-02-03T21:34:36Z (GMT). No. of bitstreams: 1 2016_LilianePereiraFurtado.pdf: 1796759 bytes, checksum: 8d93ce87199656a98bba6ba298e0e8a5 (MD5) / Este trabalho dissertativo tem por objetivo analisar uma metodologia de ensino-aprendizagem elaborada e aplicada em duas turmas de 3ª série do Ensino Médio de uma escola situada na Região Administrativa Recanto das Emas – DF. Participaram dessa pesquisa 73 alunos, sendo 37 na turma denominada por TX e 36 na TY. Essa proposta buscou contemplar uma abordagem CTS sobre radiação eletromagnética e radioatividade, baseada na literatura disponível. A concepção alternativa dos alunos participantes dessa pesquisa sobre radiação eletromagnética e radioatividades foi nosso ponto de partida. Apesar de já terem estudado alguns dos conteúdos relacionados na 2ª serie, identificamos muito equívocos conceituais e uma falta de habilidade em relacionar situações ou mesmo aplicações do conhecimento sobre radiação ionizante e não ionizante. Baseados em tais observações, propusemos um material em que o foco foi a articulação dos conteúdos relacionados à radiação eletromagnética, sua principal fonte, as aplicações, vantagens, desvantagens, os impactos sociais e ambientais. Nossa pesquisa pode ser caracterizada como um estudo de caso e a análise dos resultados teve predominância qualitativa. Coletamos os dados por meio de gravações das aulas em áudios e de anotações no diário da professora, contudo o maior volume de dados veio das atividades realizadas pelos alunos (exercícios resolvidos em sala, questionamentos sobre as atividades experimentais, tarefas de casa, fichas de avaliação de aprendizagem, avaliações e a participações durante as aulas). A análise dos dados nos revelou que a proposição aplicada se revelou um instrumento promissor para que os alunos associassem o conhecimento da Ciência sobre radiação eletromagnética e radioatividade a questões sociais, éticas, tecnológicas, ambientais, políticas e econômicas. Durante a aplicação da proposta, observamos que os recursos didáticos e as estratégias de ensino favoreceram a participação mais ativa dos alunos, proporcionando um clima encorajador, propício a reflexões sobre as situações expostas. Apesar do resultado promissor dessa experiência, consideramos que tanto o material como a forma de trabalhá-lo pode ser melhorada. Isso pode ser possível com a continuidade de sua aplicação, com a adaptação à realidade de diferentes escolas e à necessidade de diferentes educandos. / The goal of this dissertation is to analyze a teaching-learning methodology developed and applied in two classes of the 3rd grade of high school at a school located in the Região Administrativa Recanto das Emas – DF. In this research, 73 students took part, 37 in TX class and 36 in TY class. This proposal was based on CTS approach to electromagnetic radiation and radioactivity, in accordance to available literature. The alternative design of the students who participated in the research on electromagnetic radiation and radioactivity was our starting point. Despite the participating students have already studied some of the related content in the 2nd year of high school, we have identified misconceptions and a lack of ability to relate situations or applications of ionizing radiation and non-ionizing knowledge. Based on these observations, we proposed a material in which the focus was the articulation of contents related to electromagnetic radiation, its main source, the applications, advantages, and disadvantages, social and environmental impacts. Our research was a case study and the data analysis methodology is predominantly qualitative. The data consist of classes audios recorded and notes in the teacher’s diary, but the majority of data came from the educational activities carried out by students (exercises, questions about the experimental activities, homework, learning evaluation forms, assessments and participation in class). The data analysis has revealed to us that the applied proposal contributed to the students associate the electromagnetic radiation and radioactivity science knowledge with social, ethical, technological, environmental, political and economic aspects. During the implementation of the proposal, we realized that the teaching resources and strategies favored a more active students’ participation, providing an encouraging atmosphere, propitious to reflections on the exposed situations. Despite the promising results of this experience, we believe that both the material and the way of working it can be improved. This can be possible with the continuity of its application, with adaptation to the reality of different schools and the need of different students.
184

Confecção e caracterização de dosímetro luminescente de óxido de alumínio dopado com magnésio. / Luminescence dosimeter based on magnesium doped aluminum oxide: production and characterization.

José Francisco Sousa Bitencourt 09 June 2008 (has links)
O objetivo desse trabalho é confeccionar e caracterizar dosímetros luminescentes de óxido de alumínio, dopados com o elemento químico magnésio, para aplicação em dosimetria das radiações ionizantes. O óxido de alumínio é obtido pelo método do precursor polimérico; através da obtenção de resina polimérica que resulta em material cerâmico em pó após tratamentos térmicos em temperaturas específicas. As análises dosimétricas são realizadas durante ciclos de aquecimento de amostras que já tenham absorvido certa quantidade de radiação ionizante, ou dose radioativa, é a chamada Termoluminescência. Neste trabalho as fontes radioativas são emissoras de radiação- ou raios-X, que são mais presentes nos campos da radioterapia, radiodiagnóstico, geração de energia elétrica e estudos científicos. Devido às propriedades físicas do cristal, ocorre emissão de luz quando elétrons e buracos recebem energia térmica, permitindo a sua liberação de estados quânticos meta-estáveis e a recombinação com cargas opostas, liberando fótons no espectro UV/visível. A análise química por ICP AES indica as concentrações de 0,47; 0,88; 1,33; 2,61 e 3,36 mol% de Mg2+ para as cinco amostras preparadas com diferentes massas do reagente MgCO3; estes valores indicam que o procedimento para obtenção das amostras foi realizado com uniformidade adequada e, portanto, os resultados alcançados são proporcionais às concentrações de Mg2+. Inicialmente, analisando os resultados da difração de Raios-X, percebe-se que a menor temperatura utilizada para a calcinação do material cerâmico não foi suficiente para que se obtivesse a fase estrutural desejada (fase alfa), uma vez que a estrutura gama não exibiu propriedades dosimétricas para doses baixas. Este fato implicou em tratamentos térmicos adicionais em temperatura superior (1100°C). Os difratogramas obtidos comprovam a viabilidade do processo e metodologia, com amostras altamente cristalinas e ausência de fases desconhecidas que poderiam ocorrer caso houvesse contaminação. As medidas de TL acusaram uma forte emissão luminescente na região do espectro visível e UV, com picos de emissão em 125, 200, 280, 350 e 430°C, aproximadamente. Os últimos não puderam ser estudados para doses baixas, pois suas intensidades são sobrepostas pela incandescência do porta amostras. Entretanto, o pico de emissão em 200°C mostrou comportamento satisfatório e, portanto, empregado para estudos mais aprofundados. Os picos de alta temperatura (280, 360 e 430ºC) exibiram ótima resposta luminescente para altas doses absorvidas (acima de 100 Gy), sem que seu ponto de saturação fosse alcançado para doses de até 1 kGy. Variando sensivelmente a energia do feixe de irradiação foi possível determinar que a luminescência do material apresenta baixa dependência energética para energias abaixo de 40 keV, o que está de acordo com a teoria de interação energia/matéria. Acima desta energia, há diminuição do fenômeno fotoelétrico em detrimento do espalhamento Compton. As imagens obtidas por Microscopia Eletrônica de Transmissão detectaram, nas amostras dopadas, a presença de estruturas superficiais compostas por espinélio (MgAl2O4) sobre aglomerados de Al2O3. Este resultado faz crer que a ocorrência desta camada superficial aumenta significativamente a concentração de centros de recombinação e, conseqüentemente, a intensidade de emissão também é aumentada. / The aim of the present work is to obtain and characterize luminescent dosimeters made of magnesium doped aluminium oxide, for ionizing radiation dosimetry purposes. The material is produced by Pechini Method (US Patent 3.330.697, 1967), starting from a polymer that generates powder ceramic, after firing at predetermined temperatures. Dosimetric measurements were taken during heating cycles (Thermoluminescence) with gamma and X-rays irradiated samples. Due to physical properties of the crystal, light is emitted during heating, because of free carriers being released from trap centers and recombining with opposite sigh charges. Chemical analysis indicated the Mg2+ concentrations 0.47, 0.88, 1.32, 2.61 and 3.36 mol%; reactants masses and process parameters were adequate to obtain uniformity. From X-Ray Diffraction, samples calcinated at lower temperatures did not reach the properly structural phase. The gamma phase did not show dosimetric properties for the preferred spectra (UV/visible region). Calcinations at higher temperatures were necessary to obtain alpha phase, which exhibited TL emission. For doped sample, diffractograms indicated the occurrence of highly crystalline sample. TL glow curves showed high visible and UV emission, with peaks at 125, 200, 280, 365 and above 450°C. The lowest peak was faded within 24 hours after irradiation and those above 280°C could not be exactly determined due to peak overlapping. Nevertheless, the emission peak at 200°C showed itself a great achievement for the present work, because of its energy depth and dose response. For higher absorbed doses (above 100 Gy), the emission generated by deeper traps could be studied with more details: acceptable TL response and exponential growth were exhibited. The peak at 280 was not reported. Low energy dependence luminescence in observed for doses as high as 40 keV. This limitation is due to decreasing of photoelectric phenomena, which is responsible for charges trapping. Images obtained using Transmission Electron Microscopy detected surface layer in doped samples; such layer is composed by spinel (MgAl2O4). The presence of spinel layer increases recombination centers concentration, once luminescence enhancement was perceived for doped samples.
185

Efeitos da radiação gama sobre comportamento alimentar, hematócrito, glicemia e perfil eletroforético plasmático em tilápia do Nilo (Oreochromis niloticus)(Linnaeus,1759)

Borin, Fernando Henrique Rodrigues [UNESP] 31 July 2015 (has links) (PDF)
Made available in DSpace on 2016-09-27T13:39:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-31. Added 1 bitstream(s) on 2016-09-27T13:45:06Z : No. of bitstreams: 1 000868417_20170731.pdf: 124958 bytes, checksum: bf72a7f09986678cc29855b1fbd1c2c9 (MD5) Bitstreams deleted on 2017-08-07T14:09:04Z: 000868417_20170731.pdf,. Added 1 bitstream(s) on 2017-08-07T14:10:13Z : No. of bitstreams: 1 000868417.pdf: 1153725 bytes, checksum: d7676d38e8c4fa2daf08e559555e8ebf (MD5) / Os peixes são encontrados em ambientes passíveis de contaminação, dentre as quais se destaca a radiação decorrente de descartes inadequados de material radiativo ou mesmo de acidentes como de Chernobyl na Ucrânia e, mais recentemente, Fukushima no Japão. Poucos trabalhos são encontrados na literatura com o emprego de radiações ionizantes como agente estressor em peixes. Neste trabalho pretende-se quantificar o impacto de diferentes doses de radiação gama em tilápias do Nilo (Oreochromis niloticus) no comportamento alimentar, em parâmetros bioquímicos, tais como, hematócrito, glicemia e proteinograma plasmático, assim como no comprometimento na sobrevida. Neste trabalho foram utilizados 105 exemplares machos de tilápia do Nilo (Oreochromis niloticus), com o comprimento padrão médio de 11,11 ± 0,44 cm e peso médio de 40,56 ±3,64 gramas; divididos em seis grupos experimentais de 15 peixes cada e expostos à radiação gama de corpo inteiro de dose única através de um aparelho de telecobaltoterapia nas doses de 1 Gy, 2 Gy, 4 Gy, 8 Gy, 16 Gy e 32 Gy, e um grupo Controle sem irradiação. Foram coletados, em média, 0,3 mL de sangue com o auxílio de agulhas e seringas heparinizadas através de punção cardíaca. Posteriormente, foram determinadosos parâmetros de hematócrito, glicemia e proteinograma plasmático, por técnicas usuais, para se avaliarem os efeitos da radiação. Observou-se a diminuição da ingestão de alimento, devido à ocorrência de irritação na mucosa oral em doses mais elevadas de radiação. A porcentagem de hematócrito foi a variável mais sensível aos efeitos da radiação gama. Os níveis glicêmicos variaram dependendo das doses de radiação gama em função do tempo. Elevadas doses de radiação gama provocaram alterações metabólicas que modificaram os padrões das diferentes classes protéicas. A tilápia do Nilo demonstrou-se resistente às doses de 1 a 8 Gy, possivelmente devido... / Fish are found in susceptible to contamination environments, among which stands out the radiation arising from inadequate disposal of radioactive material or even accidents like Chernobyl in Ukraine and, more recently, Fukushima in Japan. Few studies are found in the literature with the use of ionizing radiation as a stressor in fish. This work aims to quantify the impact of different doses of gamma radiation in Nile tilapia (Oreochromis niloticus) in eating behavior, biochemical parameters, such as, hematocrit, glucose and plasma protein electrophoretic pattern, as well as the commitment on survival. In this work we used 105 males of Nile tilapia (Oreochromis niloticus), with the average standard length of 11.11 ± 0.44 cm and average weight of 40.56 ± 3.64 grams; divided into six experimental groups of 15 fish each and exposed to gamma radiation full-length single dose, by the use of a telecobaltoterapia apparatus in doses of 1 Gy, 2 Gy, 4 Gy, 8 Gy, 16 Gy and 32 Gy, and a group Control without irradiation. They were collected, on average, 0.3 ml of blood with the aid of needles and heparinized syringes by cardiac puncture. Subsequently, they determined the parameters hematocrit, blood glucose and plasma protein electropherogram by standard techniques, to assess the effects of radiation. There was a decrease in food intake due to the occurrence of irritation on oral mucosa in higher doses of radiation. The percentage of hematocrit was the most sensitive variable to the effects of gamma radiation. Glucose levels varied depending on the doses of gamma radiation as a function of time. High doses of gamma radiation caused metabolic alterations that changed the standards of different protein classes. The Nile tilapia shown to be resistant to doses of 1 to 8 Gy, possibly due to repair system efficiency. It is believed that in the group of 16 and 32 Gy, mortality was occurring due to infection by opportunistic agents and susceptibilityof the...
186

Estrutura eletrônica do polímero orgânico conjugado MEH-PPV em solução sob radiação ionizante /

Batagin Neto, Augusto. January 2009 (has links)
Orientador: Francisco Carlos Lavarda / Banca: Carlos Frederico de Oliveira Graeff / Banca: Paulo Monteiro Vieira Braga Barone / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Os polímeros orgânicos conjugados têm sido amplamente utilizados em diversos campos tecnológicos devido às suas características semicondutoras e ópticas. Recentemente foi relatada a possibilidade de sua utilização na área de dosimetria. O polímero MEH-PPV, quando diluído em solventes que contenham halogênios, tem apresentado características bastante promissoras nesta área, contudo não há ainda uma completa compreensão dos mecanismos envolvidos. No presente trabalho realizou-se o estudo conformacional e da estrutura eletrônica do polímero MEH-PPV em clorofórmio e as possíveis alterações provenientes da irradiação desta solução com radiações ionizantes. Métodos de modelagem de materiais foram utilizados a fim de simular o sistema. Resultados experimentais sugerem que os efeitos observados são oriundos da interação do solvente com a cadeia polimérica. A fim de investigar tal possibilidade, uma análise dos prováveis sítios de maior reatividade sobre o polímero foi realizada, apontando um mecanismo de incorporação de radicais sobre a cadeia principal. / Abstract: Organic conducting polymers have been employed in several technological fields due to its semiconducting and optical properties. Recently, several reports points to applications in radiation dosimetry. When diluted in halogen-containing solvents, the polymer MEH-PPV shows interesting properties after gamma irradiation. Despite the promising application, still is lacking a complete understanding of the underlying phenomena. In the present work, we studied the geometry conformation and electronic structure of MEH-PPV in the presence of chloroform employing molecular modeling techniques to simulate the system. Several possibilities for polymer modification under gamma radiation were investigated, following suggestion from experimental results. Finally, a model for the color modifications of the solution is present. / Mestre
187

Retrospecto de lesões radiológicas da cabeça de cães e gatos /

Melo, Denise Gomes de. January 2014 (has links)
Orientador: Júlio Carlos Canola / Coorientador: Camila de Castro Neves / Banca: Antônio Carlos Cunha Lacreta Junior / Banca: Rafaela Gomes Ferrari / Banca: Fabrício Singaretti de Oliveira / Banca: Paola Castro Moraes / Resumo: As afecções em cabeça são observadas frequentemente na clínica de pequenos animais, sendo de extrema importância o conhecimento anatômico regional para uma boa avaliação clínica e radiográfica. Devido a essa demanda e carência de compilações de estudos radiográficos das diversas afecções em cabeça, foi realizado estudo radiográfico retrospectivo, reavaliando radiografias de 669 cães e 76 gatos, do arquivo do Setor de Radiologia do Hospital Veterinário "Governador Laudo Natel" (HV), da Faculdade de Ciências Agrárias e Veterinárias, da Universidade Estadual Paulista (FCAV/UNESP), Câmpus de Jaboticabal, SP, no período de julho de 2001 a julho de 2012. Do mesmo arquivo foram avaliadas imagens tomográficas de sete cães obtidas durante o período de junho de 2011 a setembro de 2013. Foram correlacionados a frequência, a localização e o tipo das lesões cranianas com a espécie, o sexo, a faixa etária e a raça dos animais. A espécie canina foi a mais observada, sendo os cães sem padrão racial definido, os Poodles e os Pinschers os mais frequentes. Nos felinos, houve uma prevalência dos animais sem padrão racial definido. O porcentual de machos e fêmeas foi semelhante e animais com mais de oito anos e os de 2 anos a 7 anos e 11 meses foram os mais observados. Em cães, as alterações mais comuns foram os aumentos de volume de tecidos moles, sem envolvimento ósseo, em região submandibular, a displasia do occipital e as fraturas de mandíbulas. Já em felinos, foram observadas uma prevalência de fraturas de mandíbula, aumentos de volume de tecidos moles, sem envolvimento ósseo, em outras regiões exceto a submandibular e aumentos de radiopacidade em cavidade nasal, sem envolvimento ósseo. As frequências observadas neste trabalho condizem com as descritas na literatura. Conclui-se que com a radiografia é possível diagnosticar a maioria das lesões ósseas em cabeça, com exceção das neoplasias ... / Abstract: Head injuries are frequently observed in small animal clinics, and regional anatomical knowledge is extremely important to good clinical and radiographic evaluation. Due to this demand and shortage of compilations of radiographic studies of the various head injuries, a retrospective radiographic study was conducted, reviewing radiographs of 669 dogs and 76 cats, of the file from the Radiology Division of the Veterinary Hospital "Governor Laudo Natel" (HV) of Faculdade de Ciências Agrárias e Veterinárias, of Universidade Estadual Paulista (FCAV/UNESP), in Jaboticabal, SP, from July 2001 to July 2012. From the same file, were reassessed tomographic images of seven dogs obtained during the period June 2011 to September 2013. The frequency, location and type of head injury were correlated to species, sex, age and breed of animals. The dogs were the most observed, with the mongrel dogs, Poodles and Dobermann the most frequent breeds. In cats, there was a prevalence of mongrel cats. The percentage of males and females was similar and animals with more than eight years of age and 2 years to 7 years and 11 months old were most frequently observed. In dogs, the most common changes were soft tissue swelling without bone involvement, in submandibular area, occipital dysplasia and jaw fractures. In cats, a prevalence of mandibular fractures, soft tissue swelling, without bone involvement, in other regions except the submandibular area and increases radiopacity in the nasal cavity without bone involvement were observed. The frequencies observed in this study are consistent with those described in the literature. We conclude that by performing radiography it is possible to diagnose most bone head injuries, with the exception of brain tumors, that should be evaluated with computed tomography / Doutor
188

Efeitos da radiação gama sobre comportamento alimentar, hematócrito, glicemia e perfil eletroforético plasmático em tilápia do Nilo (Oreochromis niloticus)(Linnaeus,1759)

Borin, Fernando Henrique Rodrigues. January 2015 (has links)
Orientador: Joel Mesa Hormaza / Banca: Marice Thereza Corrêa Domingues Heubel / Banca: Percilia Cardoso Giaquinto / Resumo: Os peixes são encontrados em ambientes passíveis de contaminação, dentre as quais se destaca a radiação decorrente de descartes inadequados de material radiativo ou mesmo de acidentes como de Chernobyl na Ucrânia e, mais recentemente, Fukushima no Japão. Poucos trabalhos são encontrados na literatura com o emprego de radiações ionizantes como agente estressor em peixes. Neste trabalho pretende-se quantificar o impacto de diferentes doses de radiação gama em tilápias do Nilo (Oreochromis niloticus) no comportamento alimentar, em parâmetros bioquímicos, tais como, hematócrito, glicemia e proteinograma plasmático, assim como no comprometimento na sobrevida. Neste trabalho foram utilizados 105 exemplares machos de tilápia do Nilo (Oreochromis niloticus), com o comprimento padrão médio de 11,11 ± 0,44 cm e peso médio de 40,56 ±3,64 gramas; divididos em seis grupos experimentais de 15 peixes cada e expostos à radiação gama de corpo inteiro de dose única através de um aparelho de telecobaltoterapia nas doses de 1 Gy, 2 Gy, 4 Gy, 8 Gy, 16 Gy e 32 Gy, e um grupo Controle sem irradiação. Foram coletados, em média, 0,3 mL de sangue com o auxílio de agulhas e seringas heparinizadas através de punção cardíaca. Posteriormente, foram determinadosos parâmetros de hematócrito, glicemia e proteinograma plasmático, por técnicas usuais, para se avaliarem os efeitos da radiação. Observou-se a diminuição da ingestão de alimento, devido à ocorrência de irritação na mucosa oral em doses mais elevadas de radiação. A porcentagem de hematócrito foi a variável mais sensível aos efeitos da radiação gama. Os níveis glicêmicos variaram dependendo das doses de radiação gama em função do tempo. Elevadas doses de radiação gama provocaram alterações metabólicas que modificaram os padrões das diferentes classes protéicas. A tilápia do Nilo demonstrou-se resistente às doses de 1 a 8 Gy, possivelmente devido... / Abstract: Fish are found in susceptible to contamination environments, among which stands out the radiation arising from inadequate disposal of radioactive material or even accidents like Chernobyl in Ukraine and, more recently, Fukushima in Japan. Few studies are found in the literature with the use of ionizing radiation as a stressor in fish. This work aims to quantify the impact of different doses of gamma radiation in Nile tilapia (Oreochromis niloticus) in eating behavior, biochemical parameters, such as, hematocrit, glucose and plasma protein electrophoretic pattern, as well as the commitment on survival. In this work we used 105 males of Nile tilapia (Oreochromis niloticus), with the average standard length of 11.11 ± 0.44 cm and average weight of 40.56 ± 3.64 grams; divided into six experimental groups of 15 fish each and exposed to gamma radiation full-length single dose, by the use of a telecobaltoterapia apparatus in doses of 1 Gy, 2 Gy, 4 Gy, 8 Gy, 16 Gy and 32 Gy, and a group Control without irradiation. They were collected, on average, 0.3 ml of blood with the aid of needles and heparinized syringes by cardiac puncture. Subsequently, they determined the parameters hematocrit, blood glucose and plasma protein electropherogram by standard techniques, to assess the effects of radiation. There was a decrease in food intake due to the occurrence of irritation on oral mucosa in higher doses of radiation. The percentage of hematocrit was the most sensitive variable to the effects of gamma radiation. Glucose levels varied depending on the doses of gamma radiation as a function of time. High doses of gamma radiation caused metabolic alterations that changed the standards of different protein classes. The Nile tilapia shown to be resistant to doses of 1 to 8 Gy, possibly due to repair system efficiency. It is believed that in the group of 16 and 32 Gy, mortality was occurring due to infection by opportunistic agents and susceptibilityof the... / Mestre
189

Tecido ósseo e implantes dentais caracterização mecânica e biológica em condições de normalidade e submetidos à radiação ionizante

Soares, Priscilla Barbosa Ferreira 03 November 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The bone is a connective resilient tissue in continuous modification process. This tissue may be adversely affected by action of ionizing radiation, compromising the healing process and osseointegration. The integration between bone and implant is modulated by the surface of dental implants. This study aimed to evaluate overall by mechanical and histomorphometric characterization of bone tissue and its integration to the dental implants in normal conditions and when subjected to ionizing radiation. This study was divided into five specific objectives; specific objective 1: generate, through dynamic indentation test protocol to measure the Vickers hardness and the modulus of elasticity of the periimplantar bone using blocks performed by bone/implant extracted by the rabbit s tibias; specific objective 2: to evaluate the stability and osseointegration of dental implants with different surface treatments by measuring the resonant frequency and histomorphometric analysis quantifying the contact bone/implant and area fraction occupied by bone implants installed in the tibia of rabbits after periods of 2 and 4 weeks; specific objective 3: to assess the effect of ionizing radiation on tibias of rabbits modulated by the time elapsed from the application of ionizing radiation on the force to fracture, work to failure and stiffness of bone tissue measured by 3-bending flexural strength test, on the Vickers hardness and elastic modulus calculated by means of dynamic indentation test, and on the cortical bone thickness, bone volume and bone porosity percentage measured by microCT and quantification of osteocytes lacunarity, measured by histological evaluation; specific objective 4: to evaluate the effects of ionizing radiation on previous installed and osseointegrated implants by association of different methods involving Vickers hardness and modulus of elasticity measured by dynamic indentation; implant/bone stability measured by pull-out test, the thickness of cortical bone, volume of bone tissue, and percentage of bone porosity measured by microCT; specific objective 5: generate manuscript that summarize the main findings of specific objective 1, 2, 3 and 4 designated to Brazilian clinical fulfilling the social function of knowledge generation. After analyzing the results it can be concluded that the dynamic indentation method proved to be highly useful for individualized characterization of the periimplantar bone tissue. The implant surfaces with different wettability are capable of producing adequate integration bone / implant installed using instrumentation normal condition. Radiation therapy negatively affected the mechanical and structural properties of bone tissue. In areas rehabilitated with dental implant, the radiotherapy reduced partially the stability of implant/bone interface, thereby reducing the mechanical properties of the periimplantar bone tissue, mainly that bone tissue located close to implant surface, which can compromise the long-term prognosis. / O osso é um tecido conjuntivo resiliente em contínuo processo de modificação. Este tecido pode sofrer efeitos adversos frente ação da radiação ionizante, comprometendo o processo de reparo e a osseointegração. Integração esta que é modulada pela superfície de implantes dentais, Este trabalho tem como objetivo geral avaliar por meio da caracterização mecânica e histomorfométrica o tecido ósseo e a sua integração a implantes dentais em condições de normalidade e quando submetido à radiação ionizante. Este estudo foi dividido em cinco objetivos específicos; objetivo específico 1: gerar, por meio de ensaio dinâmico de indentação, protocolo para mensurar a dureza Vickers e o módulo de elasticidade do osso periimplantar, utilizando blocos composto por implante dental/osso extraídos de tíbias de coelhos; objetivo específico 2: avaliar a estabilidade e osseointegração de implantes com diferentes tratamentos de superfícies por meio da mensuração de frequência de ressonância e da análise histomorfométrica quantificando o contato osso/implante e fração de área ocupada pelo osso em implantes instalados em tíbias de coelhos, nos períodos de 2 e 4 semanas; objetivo específico 3: avaliar o efeito da radiação ionizante em tíbias de coelhos em função do período decorrido da aplicação da radiação ionizante nas propriedades de força, energia e rigidez do tecido ósseo por meio de ensaios mecânicos de resistência flexural, dureza Vickers e módulo de elasticidade por meio de ensaio de indentação dinâmica, espessura de cortical óssea, volume de tecido ósseo e percentual de porosidade por meio de microCT e quantificação das lacunas de osteócitos vazias, por meio de avaliação histológica; objetivo específico 4: avaliar o efeito da radiação ionizante sobre implantes previamente instalados e osseointegrado por meio de associação de metodologias envolvendo dureza Vickers e módulo de elasticidade mensurado por indentação dinâmica, resistência de integração implante/osso por meio de ensaio pull-out, espessura de cortical óssea, volume de tecido ósseo e percentual de porosidade por meio de microCT; objetivo específico 5: gerar síntese dos achados dos objetivos 1, 2, 3 e 4 em um artigo de comunicação aos clínicos brasileiros cumprindo a função social da geração do conhecimento. Após análise dos resultados pode-se concluir que o método de indentação dinâmica mostrou ser altamente útil na caracterização individualizada do tecido ósseo periimplantar. As superfícies de implantes com diferente molhabilidade são capazes de produzir adequada integração osso/implante em condição normal de instrumentação do osso cortical. A radioterapia interfere nas propriedades mecânicas e estruturais do tecido ósseo. Em áreas reabilitadas com implantes a radioterapia resulta em redução parcial da integração osso/implante, reduzindo as propriedades mecânicas do osso periimplantar principalmente daquele localizado próximo à superfície do implante, o que pode comprometer o prognóstico de longo prazo. / Doutor em Odontologia
190

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução

Fernandes, David Moreira [UNESP] 30 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-30Bitstream added on 2014-06-13T20:40:11Z : No. of bitstreams: 1 fernandes_dm_me_bauru.pdf: 957024 bytes, checksum: 166e807e8c28852f41e7733849398194 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo estudar as características dosimétricas do polímero poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)] (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... / This work aimed to study the dosimetric characteristics of the polymer of the polymerpoly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)] (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below)

Page generated in 0.0748 seconds