• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Μεταλλικές ενδοπροθέσεις που απελευθερώνουν φαρμακευτικές ουσίες στο ενδαγγειακό μοντέλο φλεβών κονίκλου

Κίτρου, Παναγιώτης 18 June 2014 (has links)
Το παρόν πρωτόκολλο σχεδιάστηκε προκειμένου να εκτιμήσει την ασφάλεια και την feasibility των μεταλλικών ενδοπροθέσεων που απελευθερώνουν φαρμακευτικές ουσίες (Drug-Eluting Stents, DES) έναντι των απλών μεταλλικών ενδοπροθέσεων (Bare-Metal Stents, BMS) στο φλεβικό μοντέλο κονίκλου, χρησιμοποιώντας Οπτική Συνεκτική Τομογραφία (Frequency Domain – Optical Coherence Tomography, FD-OCT). Μέθοδοι Δεκατρείς λευκοί κόνικλοι Νέας Ζηλανδίας υποβλήθηκαν σε τοποθέτηση μεταλλικών ενδοπροθέσεων που απελευθερώνουν Zotarolimus (Group DES) στη μία κοινή λαγόνιο φλέβα και απλών μεταλλικών ενδοπροθέσεων (Group BMS) στην απέναντι κοινή λαγόνιο. Τα πρωτογενή καταληκτικά σημεία περιελάμβαναν την τεχνική επιτυχία της τοποθέτησης των μεταλλικών ενδοπροθέσεων καθώς και την σύγκριση της νεοενδοθηλιακής υπερπλασίας ανάμεσα στα δύο υπό μελέτη σύνολα με την βοήθεια την οπτικής συνεκτικής τομογραφίας. Αποτελέσματα Η τεχνική επιτυχία της τοποθέτησης 13 μεταλλικών ενδοπροθέσεων που απελευθερώνουν φαρμακευτικές ουσίες και 13 απλών μεταλλικών ενδοπροθέσεων ήταν 100% (26/26 μεταλλικές ενδοπροθέσεις). Τρεις κόνικλοι πέθαναν (3/13, 23%) μέσα στις πρώτες 45 μέρες. Τα υπόλοιπα 10/13 ζώα (77%) θανατώθηκαν την 90η μέρα από την ημέρα τοποθέτησης των μεταλλικών ενδοπροθέσεων. Οι 20 μεταλλικές ενδοπροθέσεις (stents) αφαιρέθηκαν με επιτυχία. Επιτυχής FD-OCT πραγματοποιήθηκε σε όλα τα τμήματα των κοινών λαγόνιων φλεβών που αφαιρέθηκαν, 10 στο Group DES και 10 στο Group BMS. Δεν υπήρξε στατιστικά σημαντική διαφορά στην μέση νεοενδοθηλιακή υπερπλασία ανάμεσα στα δύο σύνολα (3.02±1.19mm2 στο Group DES, έναντι 2.76±1.17mm2 στο Group BMS). Συμπέρασμα Σε αυτό το πειραματικό πρωτόκολλο, η τοποθέτηση DES στο φλεβικό αγγειακό σύστημα ήταν δυνατή. Η νεοενδοθηλιακή υπερπλασία ήταν παρόμοια και στα δύο σύνολα μετά από περίοδο ελέγχου τριών μηνών. / This protocol was designed to evaluate the safety and feasibility of drug-eluting stents (DES) implantation, as well as to compare their long-term results vs. bare-metal stents (BMS) in a rabbit venous model, using Frequency-Domain Optical Coherence Tomography (FD-OCT). Methods Thirteen New Zealand white rabbits underwent implantation of a Zotarolimus-eluting stent in the iliac vein (Group DES) and a BMS in the contralateral iliac vein (Group BMS). Study’s primary endpoints included technical success and the comparison of in-stent neointimal hyperplasia in the two study groups using ex vivo FD-OCT, at 3 months. Results Thirteen DES and 13 BMS were successfully implanted. Technical success rate was 100% (26/26 stents). Three animals (3/13, 23.0%) died within the first 45 days. The remaining 10/13 animals (77%) were euthanized at the 90th day following stent implantation. The 20 stents were successfully removed. Successful ex vivo FD-OCT was performed in all stent-implanted iliac vein segments; 10 in group DES and 10 in group BMS. There was no statistically significant difference in the mean neointimal thickness (NIT) between the two groups (3.02±1.19mm² in group DES vs. 2.76±1.17mm² in group BMS; p=0.0501). Conclusions In this experimental protocol, DES application in the venous system was safe and feasible. Hyperplasia thickness was similar in both groups after 3 months follow-up.
2

Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου

Καλληδώνης, Παναγιώτης 14 February 2012 (has links)
Οι εμποτισμένες με φάρμακα μεταλλικές ενδοπροθέσεις (DES) έχει αποδειχθεί ότι ελαχιστοποιούν την υπερπλασία του ενδοθηλίου των στεφανιαίων αγγείων. Η υπερπλαστική αντίδραση του ουροθηλίου είναι το πιο συχνή επιπλοκή της χρήσης των μεταλλικών ενδοπροθέσεων στον ουρητήρα. Στην παρούσα μελέτη αξιολογήσαμε τις εμποτισμένες με zotarolimus μεταλλικές ενδοπροθέσεις (ZES- Endeavor Resolute, Medtronics Inc, USA) στον ουρητήρα χοίρων και κουνελιών. Μέθοδος: Μία ZES and μία συνήθης μεταλλική ενδοπρόθεση (BMS) τοποθετήθηκαν στον κάθε ουρητήρα 10 χοίρων και 6 κουνελιών. Η τοποθετήση έγινε κυστεοσκοπικά. Αξονική τομογραφία (CT) έγινε για την αξιολόγηση των ουρητήρων του χοίρου και ενδοφλέβιος πυελογραφία (IVP) έγινε για τον ίδιο σκοπό στα κουνέλια. Το πρόγραμμα παρακολούθησης περιλάμβανε CT ή IVP κάθε εβδομάδα για τις επόμενες 4 εβδομάδες για τους χοίρους και 8 εβδομάδες για τα κουνέλια. Σπινθηρογραφήματα νεφρών πριν την τοποθέτηση των ενδοπροθέσεων και κατά την 3 εβδομάδα παρακολούθησης έλαβε χώρα σε όλα τα ζώα. Οπτική τομογραφία συνοχής (OCT) χρησιμοποιήθηκε για την εκτίμηση της κατάστασης του αυλού και τοιχώματος των ουρητήρων που έφεραν τις ενδοπροθέσεις. Ιστοπαθολογική εξέταση των ουρητήρων με τις ενδοπρόθεσεις έγινε με τα παρασκευάσματα να έχουν στερεοποιηθεί σε glycol-methacrylate ρητίνη. Αποτελέσματα: Υπερπλαστική αντίδραση διαπιστώθηκε και στους δύο τύπους ενδοπροθέσεων. Οι BMS ενδοπροθέσεις αποφράχτηκαν πλήρως σε 7 ουρητήρες χοίρων ενώ οι ουρητήρες των ιδίων ζώων που έφεραν ZES ενδοπρόθεση έφεραν υπερπλαστική αντίδραση αλλά δεν κατέληγαν σε απόφραξη. Δύο ουρητήρες κουνελιών με BMS ενδοπροθέσεις αποφράχτηκαν τελείως ενώ όλες οι ZES ενδοπροθέσεις δε συσχετίστηκαν με απόφραξη του ουρητήρα. Διαπιστώθηκε έκπτωση της λειτουργίας 7 νεφρών χοίρων και 2 κουνελιών που είχαν ουρητήρες με αποφραγμένες ενδοπροθέσεις. Η OCT έδειξε αυξημένη υπερπλαστική αντίδραση σε ουρητήρες που έφεραν BMS ενδοπρόθεση σε σχέση με ZES. Παρόλα αυτά, η ιστοπαθολογική εξέταση έδειξε υπερπλαστική αντίδραση παρούσα σε όλες τις ενδοπροθέσεις αλλά σημαντικά περισσότερη υπερπλαστική αντίδραση στις BMS ενδοπροθέσεις. Συμπέρασμα: Οι ZES ενδοπροθέσεις στους ουρητήρες χοίρων και κουνελιών δε συσχετίστηκαν με υπερπλαστική αντίδραση που οδηγούσε σε απόφραξη της ενδοπρόθεσης. Αυτές οι ενδοπροθέσεις συσχετίστηκαν με σημαντικά μικρότερη υπερπλαστική αντίδραση συγκριτικά με τις BMS ενδοπροθέσεις ενώ η φλεγμονώδης αντίδραση ήταν παρόμοια και στους δύο τύπους ενδοπροθέσεων. / Drug eluting stents (DES) proved to minimize neointimal hyperplasia in coronary vessels. Hyperplastic reaction is the most common unwelcome event related to the use of metal mesh stents in the ureter. We evaluated the effect of zotarolimus eluting stent (ZES- Endeavor Resolute, Medtronics Inc, USA) in porcine and rabbit ureter. Methods: A ZES and a bare metal stent (BMS) were inserted in each ureter of 10 pigs and 6 rabbits. The insertion was performed by retrograde approach. Computerized tomography (CT) was used for the evaluation of porcine ureters while intraoperative intravenous pyelography (IVP) for rabbit ureters. The follow-up included CT or IVP every week for the following 4 weeks for pigs and 8 weeks for rabbits. Renal scintigraphies were performed prior to stent insertion and during the 3rd week in all animals. Optical coherence tomography (OCT) has been used for the evaluation of the luminal and intraluminal condition of the stented ureters. Histopathologic examination of the stented ureters embedded in glycol-methacrylate was performed. Results: Hyperplastic reaction was present in both stent types. BMSs in 7 porcine ureters were completely obstructed while porcine ureters stented with ZES had hyperplastic tissue which did not result in obstruction. Two rabbit ureters stented by BMS were occluded while no ZES was associated with ureteral obstruction. The function of the 7 porcine renal units and the two rabbit units with obstructed stented ureter was compromised. The OCT revealed increased hyperplastic reaction in the ureters stented by BMSs in comparison to ZESs. Although, hyperplastic reaction was present in all cases, pathology examination revealed significantly more hyperplastic reaction in BMSs. Conclusion: ZESs in the pig and rabbit ureter were not related to hyperplastic reaction resulting in stent occlusion. These stents were related to significantly lower hyperplastic reaction in comparison to BMSs while inflammation rates were similar for both stent types.
3

Films polymériques pour le développement de stents innovants / Polymeric films for innovative stent development

Pallotta, Arnaud 08 December 2017 (has links)
La prise en charge en urgence des pathologies ischémiques repose dans un premier temps sur la thrombolyse et/ou l’angioplastie puis dans un second temps sur des mesures hygiéno-diététiques. L’angioplastie consiste en la destruction de l’obstacle situé dans l’artère et elle est souvent suivie (dans 70 % des cas) par la pose d’une endoprothèse ou stent afin que le vaisseau lésé retrouve son diamètre. Malgré des innovations thérapeutiques (stents libérant des principes actifs), des problèmes de thrombose et de resténose au niveau du site lésé sont observés. Or, le monoxyde d’azote, NO, un gazotransmetteur de l’organisme, possède des propriétés intéressantes (antiagrégant plaquettaire, effet de recrutement des cellules endothéliales, effet antiprolifératif sur les cellules musculaires lisses) pour lutter contre ce phénomène, à concentration physiologique. Dans ce travail, nous avons développé une formulation innovante pouvant recouvrir un stent et étant capable de délivrer du NO. Il s’agira d’incorporer des nanoparticules d’or caractérisées par une capacité de greffage par un donneur de NO (AuNP@RSNO) très importante au sein des couches d’un film constitué de polyélectrolytes (polycations et polyanions interagissant de façon électrostatique). Ici, les AuNP sont considérées comme une matière première pharmaceutique. Une méthode de dosage et un contrôle qualité de ces dernières ont donc été développés. Les films créés présentent une stabilité importante (> 1 an) et sont capables d’immobiliser un grand nombre d’AuNP (1012 AuNP/cm²/cycle). Pour augmenter le taux de chargement des AuNP au sein des films, l’optimisation de leur construction a été réalisée. Plusieurs polycations ont été testés (chlorhydrate de poly(allylamine), poly(éthylène glycol) et poly(méthacrylate d’ester)) ainsi que deux milieux de dissolution différents (tampon phosphate et tampon Tris, à pH et concentrations identiques). Le meilleur rapport stabilité/taux de chargement a été atteint avec l’utilisation du chlorhydrate de poly(allylamine) et le tampon Tris. Enfin, les films ont présenté une inertie face à des protéines, des cellules et du sang total. Le système développé représente donc une forme adaptée pour être déposé à la surface de stents / Emergency management of ischemic pathologies is initially based on thrombolysis and / or angioplasty and secondly on hygiene-dietetic measures. Angioplasty consists of the destruction of the obstacle located in the artery and is often followed (in 70% of cases) by placing a stent so that the damaged vessel regains its diameter. Despite therapeutic innovations (drug eluting stents), problems of thrombosis and restenosis in the injured site are often observed. However, nitric oxide, NO, has interesting properties (platelet antiaggregant, endothelial cell recruitment effect, antiproliferative effect on smooth muscle cells) against this phenomenon at physiological concentration. In this work, we developed an innovative formulation that can deposited on a stent and that will be able to deliver NO. AuNP grafted with a high density of NO donors (AuNP@RSNO) will be incorporated in layer-by-layer films composed of polyelectrolytes (electrostatic interactions between polycations and polyanions) Here AuNPs are considered as a pharmaceutical raw material. A quantification method and a quality control of them were therefore developed. Created films created showed an important stability (> 1 year) and were able to immobilize a large number of AuNP (1012 AuNP/cm²/cycle). In order to increase the loading rate of AuNP films, optimization of their construction was carried out. Several polycations were tested (poly (allylamine hydrochloride), poly (ethylene glycol) and poly (methacrylate ester)) as well as two different dissolution media (phosphate buffer and Tris buffer, same pH and concentrations). The best stability/loading ratio was achieved with the use of poly (allylamine) hydrochloride and Tris buffer. Finally, the films showed inertness when they were exposed to proteins, cells and whole blood. The developed system is therefore well suited to be deposited on the surface of stents

Page generated in 0.0217 seconds