• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da técnica de ATP-bioluminescência no controle do procedimento de higienização na indústria de laticínios / Evaluation of ATP-bioluminescence techniques for hygiene monitoring in the dairy industry

Costa, Patrícia Dolabela 04 October 2001 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-07-21T11:12:03Z No. of bitstreams: 1 texto completo.PDF: 336431 bytes, checksum: 887553804bbe90d701abf5a9a80de79d (MD5) / Made available in DSpace on 2017-07-21T11:12:03Z (GMT). No. of bitstreams: 1 texto completo.PDF: 336431 bytes, checksum: 887553804bbe90d701abf5a9a80de79d (MD5) Previous issue date: 2001-10-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Foram avaliadas pela técnica de ATP-bioluminescência i) a qualidade microbiológica da água do manancial de captação para tratamento na ETA/UFV, da água de resfriamento de amônia e da água industrial de uso em um laticínio, ii) a adesão de Escherichia coli K12 e de esporos de Bacillus sporothermodurans, em suspensões, contendo cerca de 10 4 e 10 6 UFC/mL, em aço inoxidável e em polietileno de baixa densidade a 37°C e tempo de adesão de 24h. e, iii) o procedimento de higienização em superfícies de caminhão tanque, tanque de resfriamento de leite cru, tanque de equilíbrio do pasteurizador, desnatadeira, tanque de armazenamento de leite pasteurizado e tanque de equilíbrio para empacotamento de leite pasteurizado. Nas águas foram efetuadas, também, as contagens de mesófilos aeróbios, expressos em UFC/mL e coliformes totais, expressos em NMP/100mL. Nas superfícies foram determinados os números de mesófilos aeróbios aderidos, expressos em UFC/cm 2 . Foi utilizado o luminômetro UNILITEX-cel (BIOTRACE), para os testes de determinação de ATP, expressos em Unidades Relativas de Luz (URL), incluindo ATP total e livre. Em relação à água industrial, houve a concordância entre os métodos de bioluminescência e de contagem de mesófilos aeróbios e coliformes totais. As amostras de água de manancial e de resfriamento não apresentaram diferença (p<0,05), pelo teste de Tukey, para as quantidades de ATP total, livre e também para as contagens microbianas. Constataram-se concentrações de ATP microbiano diferentes para essas amostras de água. Os resultados indicam que teste de ATP total é mais recomendado e sugerem que qualidade físico-química da água diminui a medida de luz. A bioluminescência não foi apropriada para avaliar a presença de esporos de B. sporothermodurans e de E. coli nas superfícies avaliadas. A determinação das URL foi afetada pelas condições de adesão da E. coli. Os resultados mostram que tanto a concentração de ATP total e a contagem de mesófilos aeróbios foram diferentes (p<0,05) quando se comparou antes - 9772 URL e 1,20 X10 3 UFC/cm 2 - e após - 2511 URL e 1,10x10 1 UFC/cm 2 - o procedimento de higienização. A bioluminescência considerou 100% das superfícies em condições higiênicas insatisfatórias e contagem em placas apenas detectou 50%, considerando a recomendação da APHA e 28% a recomendação da OMS. Não houve concordância entre bioluminescência e a contagem microbiana na classificação quanto às condições higiênicas das diferentes superfícies. Observou-se grande variação na leitura de URL, sugerindo a necessidade de se efetuar mais de uma análise na superfície avaliada. A técnica de ATP-bioluminescência pode ser usada como indicadora das boas condições de limpeza, não apresentando relação com a contagem microbiana, indicando também a possibilidade de adesão microbiana e formação de biofilmes. / ATP-bioluminescence techniques were used to evaluate i) the microbiological quality of the ETA/UFV, treatment water, ammonia-cooling water and industrial water at a dairy, ii) the adhesion of Escherichia coli K12 and Bacillus sporothermodurans spores, in suspensions containing around 10 4 to 10 6 UFC/mL on stainless steel, at 37oC and adhesion time of 24 h and, iii) hygiene monitoring of truck surfaces, raw milk cooling tanks, pasteurizering tanks, milk centrifuge, pausterized milk storing tank and pausterized milk packaging tank. Aerobic mesophyllic and total coliform countings were also conducted in the water samples, respectively, expressed as UFC/mL and NMP/100 mL. The numbers of Aerobic mesophylls, expressed in UFC/cm 2 were determined on the surfaces. The UNILITEX-cel (Biotrace) luminometer was used for determining ATP, expressed as Relative Units of Light (RUL), including total and free ATP. For industrial water, there was an agreement between the bioluminescence and the counting methods of aerobic mesophylls and total coliforms Treatment and cooling water samples did not present any difference (p > 0.05) by the Tukey test for total and free ATP amounts nor for the microbial countings. Different microbial ATP concentrations were found for these water samples. The results indicate that the total ATP test is more adequate, suggesting that the physical chemical quality of water decreases light measurement. Bioluminescence was not appropriate to evaluate the presence of B. sporothermodurans and E. coli spores on the surfaces evaluated. RUL determination was affected by E. coli adhesion conditions. The results show that both total ATP and aerobic mesophyll countings were different (p < 0.05) when hygiene monitoring was compared before - 9772 RUL and 1.20 x 10 3 UFC/cm 2 - and after - 2511 RUL and 1.10 x 10 1 UFC/cm 2 . Biolominescence considered 100% of the surfaces to be under inadequate hygiene conditions while plate counting detected only 50%, based on APHA recommendation and 28%, based on WHO recommendation. There was no agreement between bioluminescence and microbial counting for hygiene condition classification under different surfaces. A great variation in RUL reading was observed, suggesting the need to carry out more than just one analysis on the surface evaluated. / Dissertação importada do Alexandria
2

Interferência de substâncias orgânicas e microrganismos na técnica de ATP-bioluminescência / Interference of organic substances and microorganisms in the ATP- bioluminescence technique

Simm, Erny Marcelo 29 June 2004 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-11-04T15:03:55Z No. of bitstreams: 1 texto completo.pdf: 242374 bytes, checksum: e0a0f909b979452d08aa2d7671aa36d4 (MD5) / Made available in DSpace on 2016-11-04T15:03:55Z (GMT). No. of bitstreams: 1 texto completo.pdf: 242374 bytes, checksum: e0a0f909b979452d08aa2d7671aa36d4 (MD5) Previous issue date: 2004-06-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Avaliou-se a interferência da caseína, lipídeo, sacarose, Staphylococcus carnosus e esporos de Bacillus subtilis na determinação da bioluminescência. As substâncias orgânicas e os microrganismos em suspensões ou aderidos ao aço inoxidável, AISI 304, n° 4 foram analisados isoladamente e em combinações. A bioluminescência foi determinada em luminômetro comercial, com os resultados expressos em Unidades Relativas de Luz (URL). Em relação às suspensões preparadas com três substâncias orgânicas, houve um aumento (p<0,05) no número de URL com a presença de caseína e lipídeo. A sacarose reduziu a bioluminescência. Neste mesmo tipo de suspensão aderida ao aço inoxidável, o número de URL aumentou (p<0,05) com a presença de caseína e sacarose. O lipídeo reduziu a bioluminescência. Constatou-se um maior (p<0,01) número de URL nas suspensões com 5,4x104 CDM.mL-1 de S. carnosus em relação aquelas com 2,9x104 CDM.mL-1 de esporos de B. subtilis. No que se refere às suspensões de células vegetativas ou esporo bacteriano aderidas ao aço inoxidável, adicionadas ou não das três substâncias orgânicas, a bioluminescência para S. carnosus foi sempre maior (p<0,05) do que para os esporos de B. subtilis, independente da concentração estudada. As três substâncias orgânicas reduziram o número de URL (p<0,05) quando combinadas com 5,4x104 CDM.mL-1 de S. carnosus. Quando se utilizou esporo de B. subtilis, as três substâncias orgânicas não tiveram nenhum efeito significativo (p>0,05) na determinação da bioluminescência. Três resultados diferentes foram observados quando se compararam as suspensões contendo simultaneamente as três substâncias mais célula vegetativa e aquelas que continham somente o microrganismo, todas aderidas ao aço inoxidável: redução (p<0,05) no número de URL, quando a bactéria estava na concentração de 5,4x103 CDM.cm-2, aumento na bioluminescência (p<0,05) nas suspensões onde S. carnosus estava presente na concentração de 5,4x102 CDM.cm-2 e nenhuma diferença significativa (p>0,05) foi detectada em presença de célula vegetativa na concentração de 5,4x101 CDM.cm-2. Foi detectado um aumento no número de URL nas suspensões de caseína, lipídeo e sacarose adicionadas de 2,9x103 CDM.cm-2 esporos de B. subtilis em relação à suspensão com as três substâncias orgânicas, todas aderidas ao aço inoxidável. Na comparação envolvendo as outras duas concentrações de esporo bacteriano e a suspensão com as três substâncias, percebeu-se uma redução no número de URL. As substâncias orgânicas, os microrganismos e as combinações entre eles, tanto em análises em suspensão quanto aderidos ao aço inoxidável interferiram em maior ou menor grau na técnica de bioluminescência. A determinação de ATP nas superfícies não deve ser a única técnica usada para monitorar a eficiência da higienização em indústrias de alimentos. Ela pode ser utilizada como uma ferramenta complementar da avaliação microbiológica tradicional. Além disso, para a obtenção de informações confiáveis, deve-se entender as limitações dessa técnica. / The casein, lipid, sucrose, Staphylococcus carnosus and Bacillus subtilis spores interference in the bioluminescence measurement was evaluated. The organic substances and the microorganisms, presents in suspensions or adhered to the stainless steel, were analyzed separately and in combinations. A commercial luminometer was used, with the results expressed in Relative Units of Light (RUL). In relation to the suspensions with the three organic substances, there were an increase (p<0,05) in the RUL measurements with the casein and lipid addition. The sucrose reduced the bioluminescence. In this same suspension, adhered to the stainless steel, the RUL measurements were increased (p <0,05) with the casein and sucrose addition. The lipid reduced the bioluminescence. It was verified (p <0,01) a higher RUL measurement in the suspensions with 5,4x104 CDM.mL-1 of S. carnosus in relationship those with 5,4x104 CDM.mL-1 of B. subtilis spores. For the suspensions of vegetative cells or bacterial spores adhered to the stainless steel, added or not of the three organic substances, the RUL measurements for S. carnosus were always higher (p <0,05) than for the B. subtilis spores. The suspension containing the three organic substances decreased (p <0,05) the RUL measurement when added of 5,4x104 CDM.mL-1 of S. carnosus. When the microorganism was B. subtilis spores, the three organics substances did not showed difference (p>0,05) in the bioluminescence measurement. Three different results in the bioluminescence were observed in the comparison among the suspensions containing the three substances added of vegetative cell and those that contained only the microorganism, all of them adhered to the stainless steel: it was a reduction (p <0,05) in the measurement of RUL, when the bacteria were in the concentration of 5,4x105 CDM.mL-1, it was observed an increase in the bioluminescence (p <0,05) in the suspensions when S. carnosus was present in the concentration of 5,4x104 CDM.mL-1 and it was not observed difference (p>0,05) when the vegetative cell was in the concentration of 5,4x103 CDM.mL- . An increase was detected in the RUL measurement in the casein suspensions, lipid and sucrose added of 2,9x10-3 CDM.cm-2 of B. subtilis spores in relation to the suspension with the three organic substances, all adhered to the stainless steel. In the comparison involving the other two concentrations of bacterial spore and the suspension with the three substances, it was observed a decrease in the RUL measurement. The organics substances, microorganisms and their combinations, in suspensions or adhered to stainless steel, showed an interference on ATP bioluminescence measurements. This technique should be used as an auxiliary tool associated to traditional microbiological analysis. / Não foi localizado o cpf do autor.
3

Implantação de um procedimento de higienização em uma unidade produtora de queijo minas artesanal na Região da Canastra e avaliação pelo método de atp-bioluminescência

Santos, Adbeel de Lima 03 March 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-20T14:10:45Z No. of bitstreams: 1 adbeeldelimasantos.pdf: 1016205 bytes, checksum: 9523680dcc32c8167da738acfd5b67d1 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-26T20:24:29Z (GMT) No. of bitstreams: 1 adbeeldelimasantos.pdf: 1016205 bytes, checksum: 9523680dcc32c8167da738acfd5b67d1 (MD5) / Made available in DSpace on 2016-09-26T20:24:29Z (GMT). No. of bitstreams: 1 adbeeldelimasantos.pdf: 1016205 bytes, checksum: 9523680dcc32c8167da738acfd5b67d1 (MD5) Previous issue date: 2010-03-03 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / A segurança e a viabilidade econômica da transformação do leite em seus diversos derivados dependem fundamentalmente da correta aplicação das técnicas de higienização. Sendo assim, o objetivo principal deste trabalho foi avaliar as condições higiênico-sanitárias do ambiente e das superfícies de processamento de uma unidade produtora de queijo Canastra por meio da técnica de ATPBioluminescência e propor um procedimento de higienização que contribua para a segurança e melhoria desse sistema de produção. Também foi avaliada a água utilizada na obtenção do leite e no interior da queijaria. No período mais susceptível às contaminações, ou seja, no verão, foram escolhidos 12 pontos de amostragem pertencentes ao fluxograma de produção do queijo Minas artesanal, além da água utilizada na sala de ordenha e da água utilizada no interior da queijaria. Esses pontos foram avaliados pelos métodos tradicional (referência) e ATPBioluminescência. Após isso, foi sugerido um novo procedimento de limpeza e sanitização para esses pontos, que foram avaliados ao longo das quatro estações também por ambos os métodos. Houve diferença (p<0,05) entre os resultados obtidos para as avaliações realizadas antes e após a aplicação do procedimento proposto para a maioria dos pontos amostrados. A microestrutura das superfícies de equipamentos e utensílios apresentaram uma forte interferência, pois os resultados para os pontos de amostragem mesa de enformagem e prensagem (MEP), prateleira de maturação (PM) e formas (F) não diferiram (p>0,05) independentemente do procedimento de higienização e das estações do ano. O método de ATP-Bioluminescência não apresentou concordância com o método de tradicional quanto à classificação das condições higiênicas das superfícies avaliadas. Isso deve muito possivelmente à presença de ATP de origem não microbiana oriunda de resíduos que não foram completamente eliminados na etapa de limpeza. Os resultados encontrados indicam que o método de ATPBioluminescência deve ser empregado como indicador da presença de material biológico na superfície ou água, não substituindo o método tradicional. / The food safety and the economical viability of milk processing depend on appropriated higyenization techniques. The main goal of this work was to evaluate higienics conditions of food processing environment and surfaces of a producer farm of Canastra cheese by using ATP- Bioluminescence. In addition it was also proposed a higyenization procedure to improve safety and quality of manufacture proceeding. It was also evaluated the water quality used in milking and during cheese production. During summer, which is more probability to microbial contamination, 12 points of Canastra cheese production flow were chosen. Such samples were analyzed by traditional and ATP- Bioluminescence techniques during all seasons. It was suggested a new procedure of cleaning and sanitation for both traditional and ATP- Bioluminescence methods. There was diference (p<0.05) between the results obtained before and after the proposed higyenization procedure for the most samples evaluated. The microstructure of equipments and utensils surfaces showed a strong influence in results. The results for forming and pressing table, ripening rack and forms did not differ (p>0.05) independent of higyenization procedure and year seasons. ATP- Bioluminescence did not agree with the reference method in relation to the classification of higyenic conditions of evaluated surfaces. Probably, the presence of non-microbial ATP from food residues contributed to increasing the ATP level. The results found in the present work showed that ATP- Bioluminescence technique should be used as an indicator of biological material in water and/or surface; and it does not replace the traditional method.
4

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
5

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
6

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
7

Qualidade microbiana: influência de corantes e pigmento no método de bioluminescência / Microbiology quality: Influence of dyes and pigment to bioluminescence method

Mattos, Angela Franco 05 September 2005 (has links)
A análise da qualidade microbiana de matérias-primas e de produtos por meio da técnica convencional de contagem de microrganismos exige demanda elevada de trabalho e fornece resultados em período de tempo não compatível com o desenvolvimento da tecnologia. A indústria farmacêutica e cosmética necessita de liberação rápida de seus produtos, assim métodos alternativos podem reduzir o tempo de trabalho e custo. O método de ATP bioluminescência detecta a presença ou ausência de microrganismos em até 24 horas. O método baseia-se na reação do ATP (adenosina trifosfato) provenientes do microrganismo com o complexo luciferina - luciferase, produzindo luz. Os componentes da formulação de produtos cosméticos, como os corantes e os pigmentos podem interferir na reação e influenciar na leitura da Unidade Relativa de Luz (URL). O objetivo do experimento foi validar método de ATP bioluminescência para avaliação da qualidade microbiana do pigmento Green Nº 7 e dos corantes FD&C Blue Covanor e o FD&C Red Nº 5, usados em produtos cosméticos, verificando se esses podem interferir na reação de ATP-bioluminescência , utilizando os meios de cultura TAT(Tryptone-Azolectin-Tween) , DE ( Dey Engly Neutralization Broth) e LB (Letheen Broth) . A primeira etapa da validação do sistema ATP bioluminescência foi determinar o Efeito da Amostra nas suspensões o qual verifica a presença de ATP não microbiano. A sensibilidade do ensaio foi analisada por meio do teste de limite de detecção inoculando-se os microorganismos Escherichia coli ATCC 8739, Burkholderia cepacea ATCC 25416, Staphylococcus aureus ATCC 6538, Candida albicans ATCC 10231 na suspensão das amostras. Para C. albicans não foi possível a detecção pois houve a necessidade de tempo maior de incubação. O meio de cultura TAT sem acréscimo de polissorbato 80 apresentou as melhores condições para a validação do pigmento Green Nº 7. Para corantes há necessidade ainda de uma investigação mais criteriosa, estudando outros meios de cultura, reagentes e condições que propiciem resultados adequados em conformidade com as especificações para a validação. / The analysis of the microbiology quality of raw materiais and finished products by means of the conventional technique of counting of microorganism demands high time of work and supplies resulted in period of not compatible time with the development of the technology. The rapid methods provide reliable and cost effective analysis for the microbiological evaluation the pharmaceutical and cosmetic industry. The ATP Bioluminescence detect the presence or absence of microorganisms the reduction in detection times and analysis from 72 hours to 24 hours. The bioluminescence assay is based upon the light-producing enzyme luciferase that will hydrolyze ATP to produce light. Light production is detected by a luminometer and recorded as relative light units (RLU). The purpose of this investigation was to develop and validate the use an ATP bioluminescence assay for detection microbial contamination in artificially contaminated commercial Green Nº 7 pigment and FD&C Blue Covanor e o FD&C Red Nº 5 dyes with some microbial cultures, TAT (Tryptone-Azolectin-Tween) , DE (Dey Engly Neutralization Broth) e LB (Letheen Broth), and to compare the results against standard microbiological analysis. The first step in validation of the ATP bioluminescence system was to determine the sample effect of the sample suspensions on the bioluminescence reaction where analyzed to determine whether the sample contained nonmicrobial ATP. The sensitivity of the assay to detect different levels of Escherichia coli ATCC 8739, Burkholderia cepacea ATCC 25416, Staphylococcus aureus ATCC 6538, Candida albicans ATCC 10231 was analyzed by spiking into the samples suspensions. For C. albicans contamination detection has not been possible because it has required more time than bacteria. The microbial culture TAT without addition of polissorbato 80 has presented the best conditions for the validation of the Green pigment n° 7. For dyes has still been necessity of studying other microbial culture, reagents and conditions that they propitiate resulted adequate in compliance with the specifications for the validation.
8

Qualidade microbiana: influência de corantes e pigmento no método de bioluminescência / Microbiology quality: Influence of dyes and pigment to bioluminescence method

Angela Franco Mattos 05 September 2005 (has links)
A análise da qualidade microbiana de matérias-primas e de produtos por meio da técnica convencional de contagem de microrganismos exige demanda elevada de trabalho e fornece resultados em período de tempo não compatível com o desenvolvimento da tecnologia. A indústria farmacêutica e cosmética necessita de liberação rápida de seus produtos, assim métodos alternativos podem reduzir o tempo de trabalho e custo. O método de ATP bioluminescência detecta a presença ou ausência de microrganismos em até 24 horas. O método baseia-se na reação do ATP (adenosina trifosfato) provenientes do microrganismo com o complexo luciferina - luciferase, produzindo luz. Os componentes da formulação de produtos cosméticos, como os corantes e os pigmentos podem interferir na reação e influenciar na leitura da Unidade Relativa de Luz (URL). O objetivo do experimento foi validar método de ATP bioluminescência para avaliação da qualidade microbiana do pigmento Green Nº 7 e dos corantes FD&C Blue Covanor e o FD&C Red Nº 5, usados em produtos cosméticos, verificando se esses podem interferir na reação de ATP-bioluminescência , utilizando os meios de cultura TAT(Tryptone-Azolectin-Tween) , DE ( Dey Engly Neutralization Broth) e LB (Letheen Broth) . A primeira etapa da validação do sistema ATP bioluminescência foi determinar o Efeito da Amostra nas suspensões o qual verifica a presença de ATP não microbiano. A sensibilidade do ensaio foi analisada por meio do teste de limite de detecção inoculando-se os microorganismos Escherichia coli ATCC 8739, Burkholderia cepacea ATCC 25416, Staphylococcus aureus ATCC 6538, Candida albicans ATCC 10231 na suspensão das amostras. Para C. albicans não foi possível a detecção pois houve a necessidade de tempo maior de incubação. O meio de cultura TAT sem acréscimo de polissorbato 80 apresentou as melhores condições para a validação do pigmento Green Nº 7. Para corantes há necessidade ainda de uma investigação mais criteriosa, estudando outros meios de cultura, reagentes e condições que propiciem resultados adequados em conformidade com as especificações para a validação. / The analysis of the microbiology quality of raw materiais and finished products by means of the conventional technique of counting of microorganism demands high time of work and supplies resulted in period of not compatible time with the development of the technology. The rapid methods provide reliable and cost effective analysis for the microbiological evaluation the pharmaceutical and cosmetic industry. The ATP Bioluminescence detect the presence or absence of microorganisms the reduction in detection times and analysis from 72 hours to 24 hours. The bioluminescence assay is based upon the light-producing enzyme luciferase that will hydrolyze ATP to produce light. Light production is detected by a luminometer and recorded as relative light units (RLU). The purpose of this investigation was to develop and validate the use an ATP bioluminescence assay for detection microbial contamination in artificially contaminated commercial Green Nº 7 pigment and FD&C Blue Covanor e o FD&C Red Nº 5 dyes with some microbial cultures, TAT (Tryptone-Azolectin-Tween) , DE (Dey Engly Neutralization Broth) e LB (Letheen Broth), and to compare the results against standard microbiological analysis. The first step in validation of the ATP bioluminescence system was to determine the sample effect of the sample suspensions on the bioluminescence reaction where analyzed to determine whether the sample contained nonmicrobial ATP. The sensitivity of the assay to detect different levels of Escherichia coli ATCC 8739, Burkholderia cepacea ATCC 25416, Staphylococcus aureus ATCC 6538, Candida albicans ATCC 10231 was analyzed by spiking into the samples suspensions. For C. albicans contamination detection has not been possible because it has required more time than bacteria. The microbial culture TAT without addition of polissorbato 80 has presented the best conditions for the validation of the Green pigment n° 7. For dyes has still been necessity of studying other microbial culture, reagents and conditions that they propitiate resulted adequate in compliance with the specifications for the validation.

Page generated in 0.4542 seconds