• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 200
  • 119
  • 68
  • 62
  • 56
  • 47
  • 45
  • 44
  • 39
  • 35
  • 30
  • 29
  • 25
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da rugosidade superficial e da alteração de cor do esmalte humano submetido ao clareamento dental e/ou refrigerante a base de cola, em função de escovação simulada

Cunha, Lia Alves da [UNESP] 14 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-14Bitstream added on 2014-06-13T20:22:08Z : No. of bitstreams: 1 cunha_la_dr_sjc.pdf: 684863 bytes, checksum: 8e211a6d2f18322f88b6df2f1dbde3dc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo in vitro avaliou o efeito da abrasão do esmalte humano na rugosidade superficial e na alteração de cor de dentes previamente submetidos à erosão. Quarenta e oito pré-molares humanos hígidos foram divididos em face vestibular e lingual, totalizando 96 fragmentos. Os espécimes foram divididos em quatro grupos (n=24): C - controle; O - clareamento com peróxido de hidrogênio a 38% (Opalescence Xtra Boost); OR - clareamento e imersão em refrigerante a base de cola (Coca-cola); R - imersão em refrigerante. Cada grupo foi dividido em dois subgrupos, para escovação com dentifrício de abrasividade regular (DR) e dentifrício branqueador (DB), em máquina simuladora de escovação. Antes e após o tratamento preconizado para cada grupo, a rugosidade foi mensurada em um rugosímetro (SJ-400, Mitutoyo) e a aferição da cor por meio de um espectofotômetro (Easyshade, Vita). Os dados foram submetidos à ANOVA e testes de Dunnett e Tukey. O grupo OR apresentou o maior aumento de rugosidade (0,092), que foi estatisticamente semelhante ao grupo O (0,046) e diferente da diminuição causada por R (-0,007). Quanto à alteração de cor, OR apresentou valores intermediários (7,95), sendo estatisticamente semelhante tanto ao grupo O (9,96) quanto ao R (6,37), que diferiram entre eles. Concluiu-se que a exposição do esmalte tanto ao gel clareador como à coca-cola não aumentou a rugosidade e que a exposição à coca-cola durante o tratamento clareador não ocasionou descoloração dental. Os dentifrícios regular e branqueador apresentaram desempenho de rugosidade e de alteração de cor estatisticamente semelhantes em todos os grupos avaliados. / This in vitro study aimed to evaluate the effect of human enamel abrasion on the surface roughness and color change of teeth previously submitted to erosion. Forty eight intact human pre-molars were divided in buccal and lingual faces, adding up to 96 fragments. The specimens were divided into four groups (n=24): C – control; O – bleaching with 38% hydrogen peroxide (Opalescence Xtra Boost); OB – bleaching and immersion in cola beverage; B – immersion in cola beverage. Each group was further divided into two subgroups, for brushing with regular abrasiveness dentifrice (RD) and whitening dentifrice (WT), in a toothbrushing machine. Before and after the treatment proposed for each group, roughness was measured in a profilometer (SJ-400, Mitutoyo) and colour evaluation was performed with a spectrophotometer (Easyshade, Vita). Data was submitted to ANOVA and Dunnett and Tukey tests. Group OB presented the highest roughness increase (0.092), which was statistically similar to group O (0.046) and different from the decrease caused by B (-0.007). Regarding colour change, OB presented intermediary values (7.95), which were statistically similar to group O (9.96) and B (6.37), which were different between them. It was concluded that exposure of enamel to bleaching gel or cola beverage did not increase roughness and exposure to cola soft drink during bleaching treatment did not cause dental discolouration. Regular and whitening dentifrices presented similar performance regarding surface roughness and colour change in all evaluated groups.
12

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental

Crastechini, Érica [UNESP] 14 January 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-14Bitstream added on 2014-08-13T17:59:38Z : No. of bitstreams: 1 000776317.pdf: 1195102 bytes, checksum: 85fc35fb403e655b035d4a9783d36061 (MD5) / O objetivo deste estudo foi avaliar a eficácia do laser Nd:YAG associado a diferentes sistemas adesivos autocondicionantes, na prevenção do desgaste erosivo e abrasivo do esmalte dental. Foram preparados 160 espécimes de esmalte bovino, polidos e submetidos a uma erosão inicial em ácido cítrico a 0,3 % por 5 min. Os perfis iniciais da superfície de esmalte foram medidos utilizando um perfilômetro, cuja unidade de medida é em micrométros (μm). Os espécimes foram distribuídos aleatóriamente em oito grupos (n=20): SB - Aplicação do adesivo Single Bond Universal (3M/Espe) e fotopolimerização; SB+L - Aplicação do adesivo Single Bond Universal, irradiação do laser de Nd:YAG (80 mJ,10 Hz) e fotopolimerização; FB - Aplicação do adesivo Futura Bond U (Voco) e fotopolimerização; FB+ L - Aplicação do adesivo Futura Bond U, irradiação do laser de Nd:YAG e fotopolimerização; GEN - Aplicação do adesivo G-aenial Bond (GC) e fotopolimerização; GEN +L - Aplicação do adesivo G-aenial Bond, irradiação do laser de Nd:YAG e fotopolimerização; L - Apenas irradiação do laser Nd:YAG; C - nenhum tratamento (Controle). Em seguida foram realizados diariamente os desafios erosivo, utilizando ácido cítrico a 0,3% (pH 2,6) por 2 min, e abrasivo realizado em uma máquina de escovação (40 ciclos, carga 200 g) com dentifrício diluído em saliva artificial (1:3 peso/peso). Foram realizados quatro ciclos por dia, durante 5 dias. Os perfis das superfícies do esmalte foram novamente avaliados utilizando um perfilômetro. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. O nível de significância foi de 5 %. Para a ANOVA foram observadas diferenças estatisticamente significantes (p= 0,0000) de desgaste. Os valores de média (±dp) e os resultados do teste Tukey foram: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN .... / The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles, load of 200 g) with toothpaste diluted in artificial saliva (1:3 wt/wt), were performed. Four cycles a day were performed during 5 days. The profiles of the enamel surfaces were again measured using the profilometer. Data were analyzed using analysis of variance (ANOVA) and Tukey statistical tests. The level of significance was 5%. When ANOVA (one factor) test was applied, it was observed statistical difference (p=0,0000) of surface wear. Mean values (± SD) and results of the Tukey test were: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN + L – 5,46 (±1,27) abc; SB + L – 5,78 (±1,12) abc; FB + L – 6,23 (±1,25) bc; SB - 6,35 (±1,11) c; C .....
13

Avaliação de resistência ao desgaste abrasivo de vários tipos de materiais instalados na lateral de esteira transportadora / Evaluation of resistance to abrasive wear of various types of materials installed on the side of conveyor belt

Cardines, André Luis Freitas [UNESP] 04 April 2017 (has links)
Submitted by ANDRÉ LUIS FREITAS CARDINES null (andre.cardines@raizen.com) on 2017-05-18T14:53:32Z No. of bitstreams: 1 Dissertação André V34.pdf: 12595798 bytes, checksum: d93808e1050b4d94b5543e19441d2f37 (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: No campo “Versão a ser disponibilizada online imediatamente” foi informado que seria disponibilizado o texto completo porém no campo “Data para a disponibilização do texto completo” foi informado que o texto completo deverá ser disponibilizado apenas 6 meses após a defesa. Caso opte pela disponibilização do texto completo apenas 6 meses após a defesa selecione no campo “Versão a ser disponibilizada online imediatamente” a opção “Texto parcial”. Esta opção é utilizada caso você tenha planos de publicar seu trabalho em periódicos científicos ou em formato de livro, por exemplo e fará com que apenas as páginas pré-textuais, introdução, considerações e referências sejam disponibilizadas. Se optar por disponibilizar o texto completo de seu trabalho imediatamente selecione no campo “Data para a disponibilização do texto completo” a opção “Não se aplica (texto completo)”. Isso fará com que seu trabalho seja disponibilizado na íntegra no Repositório Institucional UNESP. Por favor, corrija esta informação realizando uma nova submissão. Agradecemos a compreensão. on 2017-05-19T13:21:13Z (GMT) / Submitted by ANDRÉ LUIS FREITAS CARDINES null (andre.cardines@raizen.com) on 2017-05-19T16:42:04Z No. of bitstreams: 1 Dissertação André V34.pdf: 12595798 bytes, checksum: d93808e1050b4d94b5543e19441d2f37 (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: No campo “Versão a ser disponibilizada online imediatamente” foi informado que seria disponibilizado o texto completo porém no campo “Data para a disponibilização do texto completo” foi informado que o texto completo deverá ser disponibilizado apenas 6 meses após a defesa. Caso opte pela disponibilização do texto completo apenas 6 meses após a defesa selecione no campo “Versão a ser disponibilizada online imediatamente” a opção “Texto parcial”. Esta opção é utilizada caso você tenha planos de publicar seu trabalho em periódicos científicos ou em formato de livro, por exemplo e fará com que apenas as páginas pré-textuais, introdução, considerações e referências sejam disponibilizadas. Se optar por disponibilizar o texto completo de seu trabalho imediatamente selecione no campo “Data para a disponibilização do texto completo” a opção “Não se aplica (texto completo)”. Isso fará com que seu trabalho seja disponibilizado na íntegra no Repositório Institucional UNESP. Por favor, corrija esta informação realizando uma nova submissão. Agradecemos a compreensão. on 2017-05-19T17:09:26Z (GMT) / Submitted by ANDRÉ LUIS FREITAS CARDINES null (andre.cardines@raizen.com) on 2017-05-19T17:53:51Z No. of bitstreams: 1 Dissertação André V34.pdf: 12595798 bytes, checksum: d93808e1050b4d94b5543e19441d2f37 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-19T18:01:22Z (GMT) No. of bitstreams: 1 cardines_alf_me_ilha.pdf: 12595798 bytes, checksum: d93808e1050b4d94b5543e19441d2f37 (MD5) / Made available in DSpace on 2017-05-19T18:01:22Z (GMT). No. of bitstreams: 1 cardines_alf_me_ilha.pdf: 12595798 bytes, checksum: d93808e1050b4d94b5543e19441d2f37 (MD5) Previous issue date: 2017-04-04 / Com intuito de aumentar a disponibilidade dos equipamentos e reduzir custo de manutenção além de possibilitar a realização de entressafras em períodos reduzidos, as indústrias do setor sucroenergético têm buscado materiais de maior resistência para aplicações específicas. Diante desta condição este trabalho avaliou o desgaste em corpos de prova instalados em pontos distintos de uma esteira transportadora de toletes de cana colhidos mecanicamente. A comparação foi realizada entre cinco tipos de chapas metálicas, sendo a liga metálica ASTM A36 a mais utilizada para este fim. Os demais materiais pertencem à família dos aços inoxidáveis e dos aços ligas, sendo denominados: AISI 304, AISI 439, AISI 410D e HARDOX 450. Todos os materiais foram submetidos a análises químicas, micrografia, macrografia e dureza, com intuito de comprovar a diferença desses materiais, além disso, realizou-se a constatação do melhor material por meio de teste físico em local de alta abrasão e das análises realizadas. Todos os ensaios ocorreram durante o período de safra de cana-de-açúcar, entre os meses de março a novembro de 2016. Esses ensaios demonstraram os desgastes no decorrer dos meses de estudo, apresentando um desgaste médio final ao término da safra, no qual o HARDOX 450 demonstrou ser o material de menor desgaste. Para cada caso estudado foi apresentada uma análise econômica de modo a direcionar o melhor material a ser aplicado. / In order to increase the availability of equipment and reduce maintenance costs in addition to enabling off-season in a reduced period of time, the industries of the sugarcane industry's sector have sought higher resistance materials for specific applications. Given this condition, this work evaluated the wear on test specimens installed at different points on a conveyor belt of mechanically harvested cane. The comparison was made between five types of sheet metal, the metal alloy ASTM A36 being the most used for this purpose. The other materials belong to the family of stainless steels and alloys, being named: AISI 304, AISI 439, AISI 410D and HARDOX 450. All the materials were submitted to chemical analysis, micrography, macrography and hardness, in order to prove the difference of these materials, in addition, the best material was verified by means of physical test in place of high abrasion and the analyzes performed.. All the tests took place during the sugarcane harvest period, between March and November of 2016. These tests showed wear during the study months, showing a final average wear at the end of the harvest, in which HARDOX 450 was the least wear resistant material. For each case an economic analysis was presented in order to direct the best material to be applied.
14

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental /

Crastechini, Érica. January 2014 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Eduardo Moreira da Silva / Banca: Alessandra Buhler Borges / Resumo: O objetivo deste estudo foi avaliar a eficácia do laser Nd:YAG associado a diferentes sistemas adesivos autocondicionantes, na prevenção do desgaste erosivo e abrasivo do esmalte dental. Foram preparados 160 espécimes de esmalte bovino, polidos e submetidos a uma erosão inicial em ácido cítrico a 0,3 % por 5 min. Os perfis iniciais da superfície de esmalte foram medidos utilizando um perfilômetro, cuja unidade de medida é em micrométros (μm). Os espécimes foram distribuídos aleatóriamente em oito grupos (n=20): SB - Aplicação do adesivo Single Bond Universal (3M/Espe) e fotopolimerização; SB+L - Aplicação do adesivo Single Bond Universal, irradiação do laser de Nd:YAG (80 mJ,10 Hz) e fotopolimerização; FB - Aplicação do adesivo Futura Bond U (Voco) e fotopolimerização; FB+ L - Aplicação do adesivo Futura Bond U, irradiação do laser de Nd:YAG e fotopolimerização; GEN - Aplicação do adesivo G-aenial Bond (GC) e fotopolimerização; GEN +L - Aplicação do adesivo G-aenial Bond, irradiação do laser de Nd:YAG e fotopolimerização; L - Apenas irradiação do laser Nd:YAG; C - nenhum tratamento (Controle). Em seguida foram realizados diariamente os desafios erosivo, utilizando ácido cítrico a 0,3% (pH 2,6) por 2 min, e abrasivo realizado em uma máquina de escovação (40 ciclos, carga 200 g) com dentifrício diluído em saliva artificial (1:3 peso/peso). Foram realizados quatro ciclos por dia, durante 5 dias. Os perfis das superfícies do esmalte foram novamente avaliados utilizando um perfilômetro. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. O nível de significância foi de 5 %. Para a ANOVA foram observadas diferenças estatisticamente significantes (p= 0,0000) de desgaste. Os valores de média (±dp) e os resultados do teste Tukey foram: GEN - 4,88 (±1,09) a; L - 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN.... / Abstract: The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles, load of 200 g) with toothpaste diluted in artificial saliva (1:3 wt/wt), were performed. Four cycles a day were performed during 5 days. The profiles of the enamel surfaces were again measured using the profilometer. Data were analyzed using analysis of variance (ANOVA) and Tukey statistical tests. The level of significance was 5%. When ANOVA (one factor) test was applied, it was observed statistical difference (p=0,0000) of surface wear. Mean values (± SD) and results of the Tukey test were: GEN - 4,88 (±1,09) a; L - 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN + L - 5,46 (±1,27) abc; SB + L - 5,78 (±1,12) abc; FB + L - 6,23 (±1,25) bc; SB - 6,35 (±1,11) c; C ..... / Mestre
15

Avaliação do valamento marginal em restaurações de resina composta submetidas ao ensaio de abrasão por escovação

Braun, Ana Paula January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:22Z (GMT). No. of bitstreams: 2 000409048-0.pdf: 15543106 bytes, checksum: 5a31b56713c6a1640f963b2da4cb91a1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to evaluate the marginal breakdown in resin composite restorations after toothbrush-dentifrice abrasion. Twelve specimens were prepared with bovine incisors and four restorations had been done in the facial enamel surface of each bovine tooth. Two nanocomposites (Filtek Supreme XT and Filtek Z350, 3M/ESPE) and two hybrid composites (without nanotechnology) (4Seasons and Tetric Ceram HB, Ivoclar Vivadent) were used. Each specimen was subjected to toothbrush-dentifrice abrasion using toothbrush (Colgate Professional, Colgate-Palmolive) and dentifrice (Colgate Tripla Ação, Colgate-Palmolive) in a wear test machine (Idea-PUCRS). At baseline and each cycle interval (1; 2; 4 and 6 years) a surface profilometer (XP-2, Ambios Technology) was used to determine the marginal breakdown. Five profilometric tracings were performed in each one of the 4 restorations of the 12 samples after each period of time. The average of these 5 tracings was calculated using software Origin 7. 0 (OriginLab Corporation) and graphics were obtained where was possible to measure the marginal breakdown in the two sides of the restoration. The average of the two sides was taken as being the value of marginal breakdown (μm) of the composite resin in that period. Data were analyzed using the Analysis of Variance for Mixing Models for Repeated Measures with Subdivided Parcel and Tukey’s test adjustment. The results indicate that all composites had presented a marginal breakdown’s increased throughout the evaluated periods. Both hybrid’s composites (4Seasons and Tetric Ceram HB) exhibited a statistical significantly increase in the marginal breakdown after 4 and 6 years of toothbrushing when compared with the nanocomposites (Filtek Supreme XT and Z350), without presenting differences between itself in each period. The Filtek Supreme XT showed no significant increase over the periods and Filtek Z350 exhibited statistical significantly increase in the marginal breakdown after 6 years, without statistically significant differences in periods of 1, 2 and 4 years. The SEM images illustrate the behavior of composites throughout the time. In conclusion, the results suggest that the interfaces tooth/composite of the nanocomposites restorations (Filtek Supreme XT and Filtek Z350) are less subject to the marginal breakdown after toothbrushing. / O objetivo deste estudo foi avaliar o valamento marginal em restaurações de resina composta após ensaio de abrasão por escovação. Para isto, foram realizadas quatro restaurações na face vestibular de 12 incisivos bovinos, devidamente planificados e incluídos em resina acrílica. Os compósitos avaliados foram: Filtek Supreme XT, Filtek Z350 (3M/ESPE), ambos com nanopartículas, 4Seasons e Tetric Ceram HB (Ivoclar Vivadent), classificados como híbridos. Cada uma das 12 amostras foi submetida ao ensaio de abrasão em máquina de escovação (Idéia-PUCRS), com escova (Colgate Professional, Colgate-Palmolive) e dentifrício (Colgate Tripla Ação, Colgate-Palmolive), nos períodos correspondentes a 1, 2, 4 e 6 anos de escovação simulada. Para a análise do valamento marginal, antes e após cada período, foi utilizado um Perfilômetro XP-2 (Ambios Technology), sendo realizadas 5 varreduras em cada uma das restaurações das 12 amostras, após cada período. A média destas 5 varreduras foi calculada utilizando o software Origin 7. 0 (OriginLab Corporation) gerando um gráfico (n=240) onde foi possível medir a discrepância entre a margem em esmalte e a resina composta, nos dois lados da restauração. A média dos dois lados foi tomada como sendo o valor de valamento marginal, em μm, da resina no período avaliado. Os resultados foram submetidos à Análise de Variância por Modelos Mistos para Medidas Repetidas com Parcela Subdividida e para a análise pós-teste foi utilizado o ajuste de Tukey com nível de significância de 5%. Todas as resinas apresentaram um aumento no valamento marginal ao longo dos períodos avaliados. Tanto a resina 4Seasons como a Tetric Ceram HB apresentaram um aumento significativo no valamento marginal após 4 e 6 anos de escovação simulada e não apresentaram diferenças estatisticamente significativas entre si em cada período.A resina Filtek Supreme XT não apresentou aumento significativo ao longo dos períodos avaliados. A Filtek Z350 apresentou aumento significativo do valamento marginal no período de 6 anos, sem apresentar diferenças estatisticamente significantes nos períodos de 1, 2 e 4 anos. Os aspectos morfológicos, de amostras de cada resina observadas em MEV, após cada período avaliado, ilustram o comportamento dos compósitos ao longo do tempo frente ao ensaio de abrasão por escovação. As interfaces dente/restauração das restaurações realizadas com os compósitos Filtek Supreme XT e Filtek Z350 apresentaram menor formação de valamento marginal após a abrasão por escovação ao longo do tempo.
16

Influência da utilização dos endurecedores superficiais cimentícios na resistência à abrasão de pisos industriais de concreto

Viecili, Fabio Andre January 2004 (has links)
Os projetos de pisos industriais de concreto no seu dimensionamento avaliam, na sua maioria, somente a sua resistência às cargas de utilização, não contemplando muitas vezes o desempenho da superfície do piso devido ao desgaste por abrasão. A resistência à abrasão é de grande importância quando o tráfego consiste na utilização de equipamentos com rodas rígidas, particularmente as metálicas para o transporte de cargas em centros de armazenagens e fábricas. Sabe-se que a resistência à abrasão do concreto varia com a relação água/aglomerante e a qualidade do agregado utilizado. Como alternativa ao aumento da resistência característica do concreto para um melhor desempenho à abrasão, surgem os tratamentos superficiais baseados em argamassas com cimento, aditivos especiais e agregados selecionados, podendo estes ser de origem mineral ou metálica. O emprego dos endurecedores superficiais possibilita tratar somente a superfície que está exposta ao desgaste superficial não sendo necessário o aumento da resistência característica em toda a espessura da placa de concreto. Neste trabalho, foram avaliados o desempenho dos endurecedores cimentícios compostos com agregados minerais e metálicos em três diferentes dosagens (4 kg/m2, 8 kg/m2, 12 kg/m2) no tratamento superficial, do concreto com relação água/aglomerante 0,60 e o desempenho de concretos com diferentes relações água/aglomerante (0,45, 0,60 e 0,75) sem tratamento através de dois métodos de ensaio à abrasão. A análise dos resultados indica uma tendência que o uso dos endurecedores superficial cimentícios reduz o desgaste à abrasão, principalmente os compostos com agregados metálicos, e o seu emprego é viável economicamente.
17

Avaliação 'in situ' da ação do bochecho com solução de sulfato ferroso na superfície dentária, após a ação de um refrigerante, para reduzir o efeito sinérgico entre erosão e abrasão / In situ evaluation of the effect of a ferrous sulfate solution mouthrinse on the dental surface to reduce the synergistic effect between erosion and abrasion, after the action of a soft drink.

Sílvia Helena de Carvalho Sales Peres 29 August 2005 (has links)
O objetivo deste trabalho foi avaliar in situ a ação do bochecho com solução de sulfato ferroso para reduzir a ação erosiva e o efeito sinérgico entre erosão e abrasão, em espécimes de esmalte e de dentina humanos, quando expostos a um refrigerante (Coca-cola®). O estudo foi realizado em duas fases cruzadas, de 5 dias cada (SB- sem e CB- com bochecho), na qual 10 voluntários utilizaram placas palatinas com 6 blocos de esmalte e 6 de dentina, distribuídos em três fileiras horizontais contendo 4 blocos, correspondendo aos grupos: erosão (Eros); erosão + abrasão (1 Min) e após 30 minutos (30 Min). Os dispositivos foram imersos 4 x/dia, por 5 minutos na bebida. O dispositivo foi colocado na boca por 1 minuto com ou sem o bochecho, dependendo da etapa. Em seguida os voluntários escovaram com dentifrício fluoretado 4 espécimes de uma das fileiras indicada como 1 Min, e recolocaram o aparelho. Depois de 30 minutos escovaram mais 4 espécimes de outra fileira indicada como 30 Min e nada realizaram na fileira restante (Eros). A análise foi realizada por meio de teste de microdureza (%PDS), rugosidade superficial (µm) e perfilometria (µm). Foram aplicados os testes ANOVA e Tukey (p<0,05). A %PDS, a rugosidade e o desgaste em esmalte foram: SB Eros (-80,80%, -0,077µm, 9,30µm); SB 1Min (-76,05%, 0,024µm, 10,70µm); SB 30Min (-70,79%, -0,160µm, 10,82µm); CB Eros (-68,37%, -0,190µm, 8,56µm); CB 1 Min (-69,90%, 0,053µm, 7,13µm); CB 30 Min (-68,31%, -0,136µm, 6,81µm), respectivamente. Para dentina: SB Eros (-46,09%, -0,050µm, 8,03µm); SB 1Min (-35,07%, 0,011µm, 6,75µm); SB 30Min (-40,30%, -0,298µm, 6,13µm); CB Eros (-41,66%, -0,042µm, 5,12µm); CB 1 Min (-41,18%, 0,043µm, 5,68µm); CB 30 Min (-40,06%, -0,030µm, 3,41µm), respectivamente. O uso do bochecho propiciou redução significativa na %PDS para o esmalte quando comparado à condição sem bochecho, além de desgaste significativamente menor em dentina, independente da situação de erosão. O esmalte apresentou maior desgaste que a dentina, independente das condições experimentais. Concluiu-se que o bochecho com a solução de FeSO4 foi capaz de minimizar a erosão dentária após o uso do refrigerante e reduzir o efeito sinérgico entre erosão e abrasão tanto em esmalte quanto em dentina humanos . / The aim of this study was to evaluate in situ evaluation the effect of ferrous sulfate solution-containing mouthrinse on the reduction of the erosive action and synergistic effect between erosion and abrasion, in human enamel and dentin specimens, when exposed to a soft drink (Coca-cola®). The study was performed in two crossover stages, with 5 days each (SB- without and CB- with mouthrinse). Ten volunteers used palatal appliances with 6 enamel and 6 dentin blocks, arranged in three horizontal rows containing 4 blocks, corresponding to the groups: erosion (Eros); erosion + abrasion (1 Min) and after 30 minutes (30 Min). The appliances were immersed 4 times a day in the drink for 5 minutes. The appliance was placed in the mouth for 1 minute with or without the mouthrinse, depending on the stage. The volunteers then brushed 4 specimens of the row designed as 1 Min with fluoridated dentifrice and placed the appliance into the mouth. After 30 minutes, they brushed 4 specimens of the row designed as 30 Min, and no procedure was performed for the other row (Eros). Analysis was performed by microhardness (%PDS), surface roughness (µm) and profilometer (µm) tests. ANOVA and Tukey’s tests were applied (p<0.05). The % PDS, roughness and wear in enamel were: SB Eros (-80.80%, -0.077µm, 9.30µm); SB 1Min (-76.05%, 0.024µm, 10.70µm); SB 30Min (-70.79%, -0.160µm, 10.82µm); CB Eros (-68.37%, -0.190µm, 8.56µm); CB 1 Min (-69.90%, 0.053µm, 7.13µm); CB 30 Min (-68.31%, -0.136µm, 6.81µm), respectively. Concerning the dentin: SB Eros (-46.09%, - 0.050µm, 8.03µm); SB 1Min (- 35.07%, 0.011µm, 6.75µm); SB 30Min (-40.30%, -0.298µm, 6.13µm); CB Eros (-41.66%, -0.042µm, 5.12µm); CB 1 Min (-41.18%, 0.043µm, 5.68µm); CB 30 Min (-40.06%, -0.030µm, 3.41µm), respectively. The use of the mouthrinse provided a significant reduction in % PDS for the enamel compared to the condition without mouthrinse, besides significantly smaller wear in dentin, regardless of the situation of erosion. The enamel exhibited more wear than dentin, regardless of the study conditions. It was concluded that mouthrinse with ferrous sulfate solution was able to reduce the dental erosion after the use of soft drink and reduce the synergistic effect between erosion and abrasion, both in human enamel and dentin.
18

Influência da utilização dos endurecedores superficiais cimentícios na resistência à abrasão de pisos industriais de concreto

Viecili, Fabio Andre January 2004 (has links)
Os projetos de pisos industriais de concreto no seu dimensionamento avaliam, na sua maioria, somente a sua resistência às cargas de utilização, não contemplando muitas vezes o desempenho da superfície do piso devido ao desgaste por abrasão. A resistência à abrasão é de grande importância quando o tráfego consiste na utilização de equipamentos com rodas rígidas, particularmente as metálicas para o transporte de cargas em centros de armazenagens e fábricas. Sabe-se que a resistência à abrasão do concreto varia com a relação água/aglomerante e a qualidade do agregado utilizado. Como alternativa ao aumento da resistência característica do concreto para um melhor desempenho à abrasão, surgem os tratamentos superficiais baseados em argamassas com cimento, aditivos especiais e agregados selecionados, podendo estes ser de origem mineral ou metálica. O emprego dos endurecedores superficiais possibilita tratar somente a superfície que está exposta ao desgaste superficial não sendo necessário o aumento da resistência característica em toda a espessura da placa de concreto. Neste trabalho, foram avaliados o desempenho dos endurecedores cimentícios compostos com agregados minerais e metálicos em três diferentes dosagens (4 kg/m2, 8 kg/m2, 12 kg/m2) no tratamento superficial, do concreto com relação água/aglomerante 0,60 e o desempenho de concretos com diferentes relações água/aglomerante (0,45, 0,60 e 0,75) sem tratamento através de dois métodos de ensaio à abrasão. A análise dos resultados indica uma tendência que o uso dos endurecedores superficial cimentícios reduz o desgaste à abrasão, principalmente os compostos com agregados metálicos, e o seu emprego é viável economicamente.
19

Avaliação in vitro da abrasão produzida por dentifricios comerciais na escovação mecanica da região cervical de dentes humanos

Fortuna, Sergio 16 August 2001 (has links)
Orientador : Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T10:57:54Z (GMT). No. of bitstreams: 1 Fortuna_Sergio_M.pdf: 1973517 bytes, checksum: cf09d7d0d7be76d3db2c070c8f277af0 (MD5) Previous issue date: 2000 / Resumo: O propósito deste estudo foi avaliar a abrasividade de três dentifrícios comerciais sobre a região cervical (junção cemento-esmalte) de dentes pré-molares, provocada pela escovação mecânica. Foram utilizados 24 pré-molares superiores e inferiores, divididos em três grupos de oito. O terço apical da raiz foi seccionada com disco de diamante a fim de obter um corpo-de-prova com 15 mm de comprimento. Em seguida, os corpos-de-prova foram submetidos a 30.000 ciclos numa máquina de escovação Equilabor com os dentifrícios (Sorriso, Sensodyne e Colgate branqueador) e escova Oral-B 30. A rugosidade foi verificada com o aparelho (Suf-corder, SE 1700), antes e após os corpos-de-prova serem submetidos à escovação. Os resultados foram submetidos à análise de variância e ao teste de Tukey (5%) e indicaram que a escovação promoveu nos corpos-de-prova maior rugosidade com diferença estatística em relação aos corpos-de-prova sem escovação, para os três d_ntifrícios; os dentifrícios apresentaram diferentes. índices médios de abrasão, quando associados à escovação mecânica dos dentes; e, os dentifrícios Colgate branqueador e Sorriso foram significantemente mais abrasivos do que o dentifrício Sensodyne (p<0,05) / Abstract: The purpose of this study was to investigate the abrasivity of three dentifriees on the eervieal surfaee Ounetion eement-enamel) of the premolar teeth, by meehanie bruehing. Twenty four premolar were using in this study. The root was eut to got samples with 15 mm long. Afterwards the samples were submitted to 30,000 eycling in a brushing meehanie Equilabor with dentifriees (Sorriso, Sensodyne and Colgate branqueador) and toothbrushe Oral - B. Roughness was verified using (Surf-eorder, SE 1700) before and after toothbrushing. The results were submitted to varianee analyses and Tukey's test (p<0.05). The data indieated that the meehanie brushing showed more roughness with differenee statistieally in relation speeimens without brushing for the three dentifriees; the dentifriees showed differents abrasion when assoeiated to meehaniebrushing to the teeth; and, the dentifriees Colgate branqueador and Sorriso were signifieantly more abrasive than Sensodyne (p<0.05) / Mestrado / Mestre em Materiais Dentários
20

Efeito do uso de dentifricios com alta e baixa concentração de fluoreto suplementado com trimetafosfato sobre a erosão e abrasão do esmalte dentário bovino: estudo in vitro

Moretto, Marcelo Juliano [UNESP] 20 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-20Bitstream added on 2014-06-13T20:17:09Z : No. of bitstreams: 1 moretto_mj_me_araca.pdf: 414954 bytes, checksum: 60caaf9816fb95bacf68715af56dc0f8 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente estudo teve como objetivo avaliar in vitro a ação de dentifrícios com alta e baixa concentração de fluoretos suplementado com trimetafosfato sobre a erosão associada ou não a abrasão. Foram utilizados 150 blocos de esmalte bovino (4x4mm) que após polimento foram selecionados através da microdureza de superfície (SMH inicial). Em seguida foram divididos em 5 grupos (n=30) de acordo com o dentifrício a ser utilizado: placebo (sem flúor), 1100 μg F/g - Crest™ , 1100 μg F/g , 500 μg F/g TMP 3%, 5000 μg F/g. Os blocos foram submetidos ao desafio ácido com Sprite Zero® por 5 minutos 4 vezes ao por um período de 7 dias. Na seqüência todos os blocos receberam tratamento com slurry dos dentifrícios (1:3) por 15 segundos. Metade dos blocos (n=15) foi submetido ao processo de abrasão através da escovação por 15 segundos utilizando escova elétrica Colgate Motion®. Todos os blocos permaneceram em saliva artificial antes e após os tratamentos(37°C). A análise estatística foi aplicada considerando como fatores de variação os dentifrícios experimentais (placebo, 1100 μg F/g Crest, 1100 μg F/g, 500 μg F/g TMP 3% e 5000 μg F/g) e o tipo de desafio erosivo (erosão e erosão/abrasão), e como variável os valores de dureza de superfície antes dos desafios, porcentagem de perda de dureza de superfície (%SMHC) e desgaste da superfície do esmalte (μm). As médias da porcentagem de perda dureza da superfície (% SMHC) e os valores médios do desgaste (μm) para os grupos submetidos a erosão foram de: placebo (sem flúor) 82,26 % e 3,36 μm, 1100 μg F/g - Crest™ 73,38% e 2.46 μm, 1100 μg F/g , 72,86% e 2,46 μm, 500 μg F/g TMP 3% 62,41% e 1,29 μm, 5000 μg F/g 64,06% e 1,46 μm. Já nos grupos submetidos à erosão associada à escovação, as médias da porcentagem de perda dureza da superfície (% SMHC) e os valores médios... / The aim of the present study was to evaluate the effectiveness of the application of high and lower fluorinated dentifrices supplementation with Trimetaphosphate on the erosion associated or not to the abrasion. It was used 150 bovine enamel blocks (4x4mm). These blocks were polished and after they were selected by the microhardness surface (initial SMH). After that, they were divided in 5 groups (n=30) in accordance with the dentifrice used: Placebo (without fluoride),1100 μg F/g Crest™, 1100 μg F/g, 500 μg F/g TMP 3%, 5000 μg F/g. The groups were submitted to the acid challenge with Sprite Zero® for 5 minutes, 4 times to the day, during 7 days. In the sequence all the blocks received treatment with slurry from dentifrices (1: 3) for 15 seconds. Half of each group (n=15) was submitted to the abrasion process by brushing for 15 seconds with electric brush Colgate Motion®. All the blocks remained in artificial saliva before and after the treatments (37oC). The analysis statistics was applied considering as variation factors the experimental dentifrices (placebo, 1100 μg F/g Crest™, 1100 μg F/g, 500 μg F/g TMP 3% and 5000 μg F/g) and the type of erosive challenge (erosion and erosion/abrasion), and as changeable the values of hardness of surface before the challenges, percentage of loss of surface hardness (%SMHC) and consuming of the surface of the enamel (μm). The averages of the percentage of loss hardness of the surface (% SMHC) and the average values of the consuming (μm) for the submitted groups the erosion were: placebo (without fluoride) 82,26 % and 3,36 μm, 1100 μg F/g - Crest™ 73,38% and 2.46 μm, 1100 μg F/g , 72,86% and 2,46 μm, 500 μg F/g TMP 3% 62,41% and 1,29 μm, 5000 μg F/g 64,06% and 1,46 μm. In the groups submitted to the erosion associated to the brushing, the averages of the percentage of loss hardness of the surface... (Complete abstract click electronic access below)

Page generated in 0.0489 seconds