• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • Tagged with
  • 25
  • 25
  • 25
  • 21
  • 21
  • 21
  • 14
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation of the Welch Allen Microtympanometer compared to conventional examination methods : the effect of general anaesthesia on microtympanograms and middle ear effusions : the use of tympanometry in pre-school audiological screening programme

Black, John Henry 30 March 2017 (has links)
1) Test the accuracy of the Welch Allyn Microtympanometer against standard tympanometry. 2) Correlate preoperative clinical findings with: • Microtympanometry • Standard tympanometry 3) Assess influence of induction by gas anaesthesia on: • Post-induction microtympanometry • Intraoperative myringotomy findings 4) Assess the practicality of using the Welch Allyn Microtympanometer as a screening tool in Pre-School audiological testing.
2

Padrão de análise da timpanometria com sonda de 226 Hz na criança considerando a pressão do pico de máxima compliância e a compliância estática / Tympanometry analysis standard with 226 Hz of age six months to three years considering the pressure of the peak of maximum compliance and the static compliance

Melo, Alana Ribeiro de 08 May 2017 (has links)
A análise precisa dos resultados da timpanometria é essencial para determinar a condição da orelha média, principalmente em crianças nos primeiros anos de vida. Assim, o objetivo deste estudo foi apresentar um padrão de análise da timpanometria com sonda de 226 Hz para a faixa etária de seis meses a três anos, considerando a pressão do pico de máxima compliância e a compliância estática. Foram analisados prontuários de crianças de seis meses a três anos de idade atendidas no período de outubro de 2012 a fevereiro de 2016 no Centro de Pesquisas Audiológicas - Seção de Implante Coclear do Hospital de Reabilitação de Anomalias Craniofaciais e na Clínica de Audiologia Infantil da Clínica de Fonoaudiologia da Faculdade de Odontologia de Bauru, ambos da Universidade de São Paulo. A casuística foi dividida em dois grupos: grupo sem alteração de orelha média, composto por 224 orelhas, e o grupo com alteração de orelha média, composto por 59 orelhas. Foram considerados para análise os valores de pressão do pico de máxima compliância (daPa) e de compliância estática (ml) obtidos na timpanometria com sonda de 226Hz. No grupo sem alteração, o Teste Correlação Mann Whitney revelou que não houve diferença significante entre os sexos para pressão do pico de máxima compliância (p=0,782) e para a compliância estática (p=0,085). Também não houve correlação dos valores de pressão (p=0,678) e compliância (p=0,079) com a idade, de acordo com o Teste Correlação de Spearman. Considerando o intervalo entre os percentis 2,5 e 97,5 obtidos para a pressão e compliância nos grupos sem e com alteração, observou-se uma faixa de valores comum aos dois grupos, ou seja, os valores contidos nesta faixa não conseguiram classificar a orelha média como normal ou alterada. De acordo com os percentis 2,5 e 97,5, foi possível estabelecer uma faixa de normalidade para a pressão do pico de máxima compliância, de +52 daPa a -100 daPa, e para compliância estática, de 0,20 ml a 0,68 ml. Enquanto que na faixa de alteração, os valores variaram de -259 a 17,52 daPa para pressão e de 0,04 a 0,41 ml para a compliância. Assim, uma faixa de intersecção foi identificada, correspondente ao intervalo de -100 a 17,52 daPa para pressão do pico de máxima compliância e de 0,2 a 0,41 ml para a compliância estática. A análise dos dados demonstrou que a timpanometria com sonda de 226 Hz apresentou alta sensibilidade e baixa especificidade na faixa etária de seis meses a três anos. / Accurate analysis of tympanometry results is essential to determine the condition of the middle ear, especially in children in their first years of life. Thus, this study aimed at presenting a standard analysis of tympanometry with a 226 Hz probe for the age range six months to three years, taking into account the pressure of the peak of maximum compliance and static compliance. The records of 6-month to three-year old children assisted from October 2012 to February 2016 at the Audiology Research Center - Cochlear Implant Section of the Craniofacial Anomalies Rehabilitation Hospital and at the Children\'s Audiology Clinic of the Audiology and Speech-Language Pathology Clinic of the Bauru Dentistry School, both of the University of São Paulo, were analyzed. The sample was divided into two groups: a group with no middle ear alteration comprising 224 ears and the group with middle ear alteration composed of 59 ears. For analysis, the pressure values of the maximum compliance peak (daPa) and static compliance (ml) obtained in the tympanometry with a 226Hz probe were considered. In the group with no alteration, the Mann Whitney Correlation Test showed no significant difference between the genders for the maximum compliance peak pressure (p = 0.782) and for static compliance (p = 0.085). No difference was seen, either, for pressure (p = 0.678) and compliance (p = 0.079) values, according to age, by using the Spearman Correlation Test. Considering the interval between percentiles 2,5 and 97,5 obtained for pressure and compliance in the groups without and with alteration, a range of values common for the two groups was observed, that is, the values contained in this range could not classify the Middle ear as normal or altered. According to percentiles 2,5 and 97,5, it was possible to establish a range of normality for the pressure of the maximum compliance peak, from +52 daPa to -100 daPa, and for static compliance, from 0.20 ml to 0.68 ml, while in the alteration range, values ranged from -259 to 17,52 daPa for pressure and from 0,04 to 0,41 ml for compliance. Thus, an intersection range was identified, corresponding to the interval of -100 to 17,52 daPa for the pressure of the maximum compliance peak and 0,2 to 0,41 ml for the static compliance. Data analysis showed that tympanometry with a 226 Hz probe presented high sensitivity and low specificity in the 6-month to 3-year age range.
3

"Audiometria de altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido" / High frequency audiometry in individuals with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint

Guedes, Ana Paula de Souza 31 August 2005 (has links)
Indivíduos com audição normal entre 250 e 8.000 Hz podem apresentar zumbido. Além da avaliação audiológica convencional, a audiometria de altas freqüências tem sido aplicada nestes casos. O objetivo desta pesquisa foi avaliar os limiares de audibilidade nas altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido. A pesquisa foi realizada em 33 indivíduos com zumbido e 33 sem zumbido. Houve piora estatisticamente significante entre os limiares de audibilidade dos indivíduos com zumbido em relação aos indivíduos sem zumbido para as seguintes freqüências: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 e 20.000 Hz / Subjects with normal hearing between 250 and 8.000 Hz may show tinnitus. Beyond the conventional audiological evaluation, the high frequency audiometry has been applied in these cases. The research's goal was to evaluate the audibility thresholds in high frequencies in subjects with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint. The research was carried through in 33 individuals with tinnitus and 33 with no tinnitus. A significant statistical worsening occurred between hearing thresholds of subjects with tinnitus with relation to subjects with no tinnitus for the following frequencies: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 and 20.000 Hz
4

Medidas de imitância acústica de banda larga em indivíduos com otosclerose / Wideband acoustic immittance measurements in subjects with otosclerosis

Chaves, Juliana Nogueira 29 March 2017 (has links)
Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular. / In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.
5

Padrão de análise da timpanometria com sonda de 226 Hz na criança considerando a pressão do pico de máxima compliância e a compliância estática / Tympanometry analysis standard with 226 Hz of age six months to three years considering the pressure of the peak of maximum compliance and the static compliance

Alana Ribeiro de Melo 08 May 2017 (has links)
A análise precisa dos resultados da timpanometria é essencial para determinar a condição da orelha média, principalmente em crianças nos primeiros anos de vida. Assim, o objetivo deste estudo foi apresentar um padrão de análise da timpanometria com sonda de 226 Hz para a faixa etária de seis meses a três anos, considerando a pressão do pico de máxima compliância e a compliância estática. Foram analisados prontuários de crianças de seis meses a três anos de idade atendidas no período de outubro de 2012 a fevereiro de 2016 no Centro de Pesquisas Audiológicas - Seção de Implante Coclear do Hospital de Reabilitação de Anomalias Craniofaciais e na Clínica de Audiologia Infantil da Clínica de Fonoaudiologia da Faculdade de Odontologia de Bauru, ambos da Universidade de São Paulo. A casuística foi dividida em dois grupos: grupo sem alteração de orelha média, composto por 224 orelhas, e o grupo com alteração de orelha média, composto por 59 orelhas. Foram considerados para análise os valores de pressão do pico de máxima compliância (daPa) e de compliância estática (ml) obtidos na timpanometria com sonda de 226Hz. No grupo sem alteração, o Teste Correlação Mann Whitney revelou que não houve diferença significante entre os sexos para pressão do pico de máxima compliância (p=0,782) e para a compliância estática (p=0,085). Também não houve correlação dos valores de pressão (p=0,678) e compliância (p=0,079) com a idade, de acordo com o Teste Correlação de Spearman. Considerando o intervalo entre os percentis 2,5 e 97,5 obtidos para a pressão e compliância nos grupos sem e com alteração, observou-se uma faixa de valores comum aos dois grupos, ou seja, os valores contidos nesta faixa não conseguiram classificar a orelha média como normal ou alterada. De acordo com os percentis 2,5 e 97,5, foi possível estabelecer uma faixa de normalidade para a pressão do pico de máxima compliância, de +52 daPa a -100 daPa, e para compliância estática, de 0,20 ml a 0,68 ml. Enquanto que na faixa de alteração, os valores variaram de -259 a 17,52 daPa para pressão e de 0,04 a 0,41 ml para a compliância. Assim, uma faixa de intersecção foi identificada, correspondente ao intervalo de -100 a 17,52 daPa para pressão do pico de máxima compliância e de 0,2 a 0,41 ml para a compliância estática. A análise dos dados demonstrou que a timpanometria com sonda de 226 Hz apresentou alta sensibilidade e baixa especificidade na faixa etária de seis meses a três anos. / Accurate analysis of tympanometry results is essential to determine the condition of the middle ear, especially in children in their first years of life. Thus, this study aimed at presenting a standard analysis of tympanometry with a 226 Hz probe for the age range six months to three years, taking into account the pressure of the peak of maximum compliance and static compliance. The records of 6-month to three-year old children assisted from October 2012 to February 2016 at the Audiology Research Center - Cochlear Implant Section of the Craniofacial Anomalies Rehabilitation Hospital and at the Children\'s Audiology Clinic of the Audiology and Speech-Language Pathology Clinic of the Bauru Dentistry School, both of the University of São Paulo, were analyzed. The sample was divided into two groups: a group with no middle ear alteration comprising 224 ears and the group with middle ear alteration composed of 59 ears. For analysis, the pressure values of the maximum compliance peak (daPa) and static compliance (ml) obtained in the tympanometry with a 226Hz probe were considered. In the group with no alteration, the Mann Whitney Correlation Test showed no significant difference between the genders for the maximum compliance peak pressure (p = 0.782) and for static compliance (p = 0.085). No difference was seen, either, for pressure (p = 0.678) and compliance (p = 0.079) values, according to age, by using the Spearman Correlation Test. Considering the interval between percentiles 2,5 and 97,5 obtained for pressure and compliance in the groups without and with alteration, a range of values common for the two groups was observed, that is, the values contained in this range could not classify the Middle ear as normal or altered. According to percentiles 2,5 and 97,5, it was possible to establish a range of normality for the pressure of the maximum compliance peak, from +52 daPa to -100 daPa, and for static compliance, from 0.20 ml to 0.68 ml, while in the alteration range, values ranged from -259 to 17,52 daPa for pressure and from 0,04 to 0,41 ml for compliance. Thus, an intersection range was identified, corresponding to the interval of -100 to 17,52 daPa for the pressure of the maximum compliance peak and 0,2 to 0,41 ml for the static compliance. Data analysis showed that tympanometry with a 226 Hz probe presented high sensitivity and low specificity in the 6-month to 3-year age range.
6

Medidas de imitância acústica de banda larga em indivíduos com otosclerose / Wideband acoustic immittance measurements in subjects with otosclerosis

Juliana Nogueira Chaves 29 March 2017 (has links)
Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular. / In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.
7

"Audiometria de altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido" / High frequency audiometry in individuals with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint

Ana Paula de Souza Guedes 31 August 2005 (has links)
Indivíduos com audição normal entre 250 e 8.000 Hz podem apresentar zumbido. Além da avaliação audiológica convencional, a audiometria de altas freqüências tem sido aplicada nestes casos. O objetivo desta pesquisa foi avaliar os limiares de audibilidade nas altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido. A pesquisa foi realizada em 33 indivíduos com zumbido e 33 sem zumbido. Houve piora estatisticamente significante entre os limiares de audibilidade dos indivíduos com zumbido em relação aos indivíduos sem zumbido para as seguintes freqüências: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 e 20.000 Hz / Subjects with normal hearing between 250 and 8.000 Hz may show tinnitus. Beyond the conventional audiological evaluation, the high frequency audiometry has been applied in these cases. The research's goal was to evaluate the audibility thresholds in high frequencies in subjects with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint. The research was carried through in 33 individuals with tinnitus and 33 with no tinnitus. A significant statistical worsening occurred between hearing thresholds of subjects with tinnitus with relation to subjects with no tinnitus for the following frequencies: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 and 20.000 Hz
8

Timpanometria de banda larga e emissões otoacústicas em crianças com indicadores de risco para a deficiência auditiva / Wideband tympanometry and otoacoustic emissions in children with risk indicators for hearing impairment

Raignieri, Jéssica 14 March 2018 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2018-06-15T12:32:33Z No. of bitstreams: 1 Jéssica Raignieri.pdf: 1240538 bytes, checksum: 94c6dfb67614061048d3c5cfdd8ce0c9 (MD5) / Made available in DSpace on 2018-06-15T12:32:34Z (GMT). No. of bitstreams: 1 Jéssica Raignieri.pdf: 1240538 bytes, checksum: 94c6dfb67614061048d3c5cfdd8ce0c9 (MD5) Previous issue date: 2018-03-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Introduction: Audiological monitoring is aimed at monitoring children from six months to three years old, due to the risk of late or progressive hearing loss. Objective: To study the results of the Wideband Tympanometry in acoustic absorbance measurements and the Transient Evoked Otoacoustic Emissions and Distortion Product record in children with risk indicators for hearing loss during audiological monitoring. Method: Fifty-eight children with risk indicators for hearing loss were evaluated in the audiological monitoring process, with a mean age of 16.7 months. In order to contact the families of the children, phone calls were made, with information obtained from a database of four public maternity hospitals in São Paulo. Subjects were characterized in normal auditory status and conductive altered auditory status, in the groups with and without risk indicators for auditory deficiency, and according to the audiological results of auditory monitoring. Transient Otoacoustic Emissions and Distortion Product tests were performed, in addition to the Wideband Tympanometry. For the analysis of the absorbance in the Wideband Tympanometry, seven frequency bands were selected from 1 kHz to 8 kHz, similar to the Otoacoustic Emission Frequency bands. Results: In this study, the absorbance curves presented similar results for the right and left ears, both for children with normal hearing, and for those with conductive hearing loss, as well as for females and males. It was observed that in the frequencies between 1500 Hz and 6000 Hz, the subjects with normal hearing status, the absorbance was between 0.92 and 0.98, and the best results obtained for this age group being in this frequency range. Absorbance is higher in the group of children without risk indicators for hearing loss (RIHL) when compared to the group of children with (RIHL). The recording of Transient Otoacoustic Emissions (TOAE) and Distortion Product Otoacoustic Emissions (DPOAE) showed a strong agreement with the measured absorbance in all frequency bands in both ears. Conclusion: Absorbance values are higher in males, and for children with normal hearing status. 13 There was an agreement for the results of Evoked Otoacoustic Emissions level and absorbance measurements, and the higher the absorbance, the higher the TOAE and DPOAE levels / Introdução: o monitoramento audiológico visa ao acompanhamento de crianças de seis meses até três anos de idade, devido ao risco de perdas auditivas de início tardio ou progressivo. Objetivo: estudar os resultados da Timpanometria de Banda Larga nas medidas de absorvância acústica e do registro das Emissões Otoacústicas Evocadas Transiente e Produto de Distorção, em crianças com indicadores de risco para a deficiência auditiva durante o monitoramento audiológico. Método: foram avaliadas 58 crianças com indicadores de risco para a deficiência auditiva no processo de monitoramento audiológico, com idade média de 16,7 meses de vida. Para contato com as famílias das crianças, ligações telefônicas foram realizadas, com informações obtidas de um banco de dados de quatro maternidades públicas de São Paulo. Os sujeitos foram caracterizados em status auditivo normal e status auditivo alterado condutivo nos grupos com e sem indicadores de risco para a deficiência auditiva e de acordo com os resultados audiológicos do monitoramento auditivo. Foram realizados testes de Emissões Otoacústicas Transientes e Produto de Distorção, além da Timpanometria de Banda Larga. Para análise da absorvância na Timpanometria de Banda Larga, foram selecionadas sete bandas de frequências que variam de 1 kHz a 8 kHz similares às bandas de frequências. Resultados: neste estudo, as curvas de absorvância apresentaram-se de forma similar para as orelhas direita e esquerda, tanto para as crianças com audição dentro da normalidade, como para aquelas com perdas auditivas condutivas e, também, no sexo feminino e masculino. Observou-se que, na frequência de 1500 Hz a 6000 Hz, nos sujeitos com status auditivos normal, a absorvância estava entre 0,92 a 0,98, podendo estar, nessa faixa de frequência, os melhores resultados obtidos para essa faixa etária estudada. A absorvância foi maior no grupo de crianças sem 11 indicadores de risco para a deficiência auditiva (IRDA) quando comparado com o grupo de crianças com IRDA. O registro das Emissões Otoacústicas Transientes (EOAT) e Emissões Otoacústicas Produto de Distorção (EOAPD) apresentou uma forte concordância com a medida de absorvância registrada, em todas as bandas de frequências, em ambas as orelhas. Conclusão: os valores de absorvância são maiores no sexo masculino e em crianças com status auditivo normal. Houve concordância para os resultados de nível de Emissões Otoacústicas Evocadas e medidas de absorvância, sendo que, quanto maior a absorvância, maior o nível de EOAT e EOPD
9

Medidas de imitância acústica de banda larga em crianças com perda auditiva sensorial severa e profunda e diferentes achados timpanométricos / Wideband acoustic immittance measurements in children with severe and profound sensorineural hearing loss, and different tympanometric findings

Araujo, Eliene Silva 27 February 2015 (has links)
A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics\' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas para a absorvância e magnitude da impedância, com maior reflexo da variação dos valores de compliância e pressão nos resultados obtidos com estímulo chirp. Conclui-se que as características das medidas de imitância acústica de banda larga estão relacionadas à condição de orelha média e a frequência do estímulo teste. Para o delay da reflectância observou-se uma ampla variabilidade entre frequências ao analisar os grupos subdivididos pela pressão e também na frequência de 258 Hz ao analisar os grupos subdivididos pela compliância. / The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics\' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance and pressure values in the results obtained with the chirp stimulus. It is concluded that the characteristics of broadband acoustic immittance measures are related to the condition of middle ear condition and the frequency of the test stimulus. For Reflectance delay, a wide variability between frequencies was observed when analyzing the groups subdivided by pressure and also in the frequency of 258 Hz, when analyzing the groups subdivided by compliance.
10

Efeito da apneia obstrutiva do sono na audição de adultos / Effects of obstructive sleep apnea in adult hearing

Matsumura, Erika 07 June 2016 (has links)
Introdução: A apneia obstrutiva do sono (AOS) provoca modificações na arquitetura normal do sono, fragmentando-o de forma crônica com hipóxias intermitentes levando, a longo prazo, a sérias consequências na saúde. Acredita-se que a ocorrência de eventos respiratórios durante o sono como apneia e hipopneia pode prejudicar o mecanismo de transdução da orelha interna e a transmissão de impulsos nervosos ao longo da via auditiva que são altamente dependentes do fornecimento do oxigênio. Contudo, essa associação não se encontra bem estabelecida na literatura. Adicionalmente, sujeitos com AOS poderiam apresentar alterações na função de transferência acústica da orelha média devido ao desequilíbrio pressórico existente nas vias aéreas superiores durante o sono, característico da fisiopatologia da doença. Objetivo: Comparar os achados da avaliação auditiva entre os indivíduos portadores e não portadores de AOS. Método: A casuística foi composta por 38 adultos do sexo masculino, média de idade de 35,8 (±7,2) e foram divididos em quatro grupos experimentais pareados por idade e índice da massa corpórea. Os grupos foram classificados com base na polissonografia em: controle (n=10), AOS leve (n=11), AOS moderada (n=8) e AOS grave (n=9). Todos os sujeitos do estudo negaram história pregressa de risco para perda auditiva. Todos os sujeitos foram submetidos à audiometria convencional, timpanometria, pesquisa de reflexos acústicos ipsi e contralaterais, imitância acústica de banda larga com estímulo clique de 226 a 8000 Hz para obtenção da energia de absorvância (EA), emissões otoacústicas por produto de distorção e potenciais evocados auditivos de tronco encefálico. Os resultados foram submetidos às análises estatísticas e o nível de significância adotado foi de 5% para todos os testes. Resultados: As medidas da EA não mostraram diferença significante entre os grupos quando considerados somente o fator grupo (sem AOS, AOS leve, moderada e grave). Para o efeito de interação entre os fatores grupo e frequência, o valor da média da EA do grupo com AOS de grau moderado foi significativamente maior do que do grupo com AOS de grau leve (p=0,003) em 8000 Hz. O grupo com AOS de grau grave apresentou menores valores das médias das amplitudes das EOAPD quando comparados aos dos grupos controle, AOS de grau leve e AOS de grau moderado (p=0,02, p=0,03 e p=0,01, respectivamente). Não houve diferença significante nos valores das latências absolutas das ondas I, III e V, e interpicos I-III, III-V e I-V entre os grupos. Observou-se associação entre a presença da AOS e alteração da latência absoluta da onda V (p=0,03). Foi observada associação entre AOS de grau moderado e alteração da latência da onda V (p=0,01). Conclusão: A presença da AOS está associada à presença de alteração na condução nervosa do estímulo acústico na via auditiva em tronco encefálico. A presença de AOS de grau grave prejudicou a função coclear. De maneira geral, a função de transferência acústica da orelha média é similar entre os adultos com e sem AOS / Introduction: The obstructive sleep apnea (OSA) can change the normal sleep architecture, fragmenting it chronically with intermittent hypoxias and, to the long time, inducing to serious consequences to health. It is believed that the occurrence of respiratory events during sleep with the presence of apnea and hipopneia can damage the transduction mechanism of the inner ear and nerve impulses transmission along the auditory pathways, which are highly dependent on the oxygen supply. However, this association is not well established. Moreover, the acoustic transference function of middle ear could show alterations, due to the pressure changes that occur in upper airway during the sleep, typical of OSA pathophysiology. Objective: To compare the findings of the hearing evaluations between subjects with OSA and without OSA. Method: A total of 38 subjects of the male sex, mean age 35.8 (±7.2), were divided into four groups, which were matched for age and body mass index. The groups were classified by the means of polissomnography in without OSA (n=10), mild OSA (n=11), moderate OSA (n=8) and severe OSA (n=9). All the subjects denied a history of risk for hearing loss. These subjects were submitted to: conventional audiometry, tympanometry, ipsilateral, contralateral acoustic reflex, wideband acoustic immittance for measurements of energy of absorbance (EA) with click stimulus of 226 to 8000 Hz, distortion product of otoacoustic emissions (DPOAE) and click evoked auditory brainstem responses (ABR). The recorded data of each analysis were conducted to an appropriate statistical test and was adopted the significant level of 5% for all the tests. Results: The EA data did not showed statistical differences among the groups when considering only the OSA severity factor (without, mild, moderate or severe). For the interaction between OSA severity and frequency factors, the mean value of EA of moderate OSA group was significant higher than the mild OSA group (p=0.003) in 8000 Hz. The severe OSA group presented lower mean values of amplitudes of DPOAE when compared to the control group, mild and moderate OSA groups (respectively, p=0.02, p=0.03 and p=0.01). For ABR, no differences was observed in latencies waves I, III and V, and interpeaks I-III, III-V and I-V values among the groups. Conclusion: The presence of OSA is associated with the presence of alterations in the nerve conduction of acoustic stimuli in the auditory pathway in the brainstem. The presence of severe OSA impaired the DPOAE responses. In general, the acoustic transference function of middle ear is similar between the adults with and without OSA

Page generated in 0.1205 seconds