• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 256
  • 136
  • 18
  • 11
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 499
  • 211
  • 163
  • 117
  • 104
  • 83
  • 74
  • 71
  • 65
  • 51
  • 51
  • 49
  • 44
  • 43
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Biocompatibilidade de resinas acrílicas para base e reembasamento de próteses após períodos de imersão em soluções desinfetantes : análise do metabolismo celular /

Masetti, Paula. January 2016 (has links)
Orientador: Janaina Habib Jorge / Banca: Ana Carolina Pero Vizoto / Banca: Claudia Helena Lovato da Silva / Resumo: O objetivo deste estudo foi avaliar o efeito cumulativo das soluções desinfetantes na citotoxicidade de resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase II) de próteses. Corpos de prova com 14 mm de diâmetro e 1,2 mm de espessura foram distribuídos em grupos (n=3) de acordo com o tipo de solução: água destilada, digluconato de clorexidina a 2%, perborato de sódio a 3,8%, hipoclorito de sódio a 0,5% e vinagre de maçã, e de acordo com o tempo de imersão: 0, 1, 3 e 6 meses. Os corpos de prova, tanto de base quanto de reembasamento, ficaram 8 horas imersos nas soluções e 16 horas em água destilada, simulando desinfecção noturna das próteses. As soluções foram trocadas diariamente. Após os diferentes períodos de imersão, as amostras foram colocadas em meio de cultura por 24 horas para obtenção de extratos para análise da citotoxicidade sobre queratinócitos humanos (HaCaT: 0341). O metabolismo celular foi avaliado pelo teste Alamar Blue ®. Empregou-se análise de variância (ANOVA) e teste de Tukey, com significância de 5%. Os resultados demonstraram que o tipo de resina não teve influência sobre o metabolismo celular. Além disso, a imersão das amostras de resina acrílica para base e reembasamento de próteses em água destilada, perborato de sódio a 3,8% e hipoclorito de sódio a 0,5% não influenciou o metabolismo celular dos queratinócitos, independentemente do tempo de imersão. Os extratos obtidos a partir da imersão das amostras em digluconato de clorexidina ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the cumulative effect of disinfectant solutions in cytotoxicity base acrylic resins (Vipi Wave) and reline (Tokuyama Rebase II) of dentures. Samples of 14 mm diameter and 1.2 mm thick were distributed in groups (n = 3) according to the type of disinfectant solution: distilled water, 2% chlorhexidine digluconate, 3.8 % sodium perborate, 0.5% sodium hypochlorite and apple vinegar and in accordance with the immersion time: 0, 1, 3 and 6 months. The samples of both base and of reline, eight hours were immersed in solutions and 16 hours in distilled water, simulating night disinfection of prostheses. The solutions were changed daily. After different periods of immersion, the samples were placed in culture medium for 24 hours to obtain extracts for analysis of cytotoxicity on human keratinocyte (HaCaT: 0341). The cellular metabolism was assessed by Alamar Blue ® test. It used analysis of variance (ANOVA) and Tukey test, with 5% significance. The results demonstrated that the resin type had no influence on cellular metabolism. Furthermore, the immersion of the samples in acrylic resin base and reline dentures in distilled water, 3.8% sodium perborate and 0.5% sodium hypochlorite did not influence the cellular metabolism of keratinocytes, regardless of the time of immersion. The extracts obtained from immersing the samples 2% chlorhexidine digluconate or apple vinegar for 3 and 6 months were considered strongly cytotoxic. It was concluded t... (Complete abstract click electronic access below) / Mestre
132

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial /

Haddad, Marcela Filié. January 2013 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Adriana Cristina Zavanelli / Banca: Cláudia Helena Lovato da Silva / Banca: Marcelo Ferraz Mesquita / Resumo: Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Abstract: Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / Doutor
133

The influence of powder liquid ratio on the flexural strength of fibre reinforced acrylic resin material

Du Rand, Marlene January 2007 (has links)
Thesis (MTech (Dental Technology Discipline))--Cape Peninsula University of Technology, 2007 / Practitioners often modify the powder:liquid ratio of polymethyl methacrylate resins (PMMA) to improve the handling properties of the material for certain procedures or because of personal preferences. While it is known that this influences the mechanical properties of unreinforced resin materials, little is known about its effect on glass fibre reinforced PMMA resin.
134

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares /

Andreotti, Agda Marobo. January 2014 (has links)
Orientador: Daniela Micheline dos Santos / Banca: Marcelo Coelho Goiato / Banca: Simone Cecílio Hallak Regalo / Resumo: Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / Abstract: A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control - without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / Mestre
135

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores /

Shibayama, Ricardo. January 2002 (has links)
Orientador: Humberto Gennari Filho / Banca: Wirley Gonçalves Assunção / Banca: Marcelo Ferraz Mesquita / Resumo: Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / Abstract: This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four. / Mestre
136

Efeito da irradiação por microondas sobre a resistência à flexão e dureza de resinas acrílicas para reembasamento imediato /

Ribeiro, Daniela Garcia. January 2004 (has links)
Orientador: Ana Cláudia Pavarina / Banca: Eunice Teresinha Giampaolo / Banca: Ricardo Faria Ribeiro / Resumo: O uso do microondas tem sido indicado como um método efetivo na desinfecção de resinas acrílicas. Entretanto, há pouca informação sobre o efeito da irradiação do microondas nas propriedades mecânicas desses materiais. Considerando esses aspectos, o objetivo deste estudo foi avaliar o efeito da irradiação por microondas sobre as propriedades mecânicas de resistência à flexão e dureza de resinas acrílicas. Os corpos-de-prova para a realização dos testes mecânicos foram confeccionados com os seguintes materiais: Kooliner (K), Tokuso Rebase Fast (TR), Ufi Gel Hard C (UGH) e New Truliner (NT), todas resinas indicadas para reembasamento imediato, e Lucitone 550 (L), que é uma resina para base de prótese. Para cada material foram confeccionados 48 corpos-de-prova que foram divididos igualmente em seis grupos. As resinas autopolimerizáveis (K, TR, UGH e NT) foram submetidas à irradiação logo após a confecção, enquanto que os corpos-de-prova da resina termopolimerizável (L) permaneciam 50 l 2 horas em água a 37ºC l 1ºC antes da irradiação. Para o procedimento de irradiação, cada corpo-de-prova foi individualmente imerso em 200 mL de água destilada e submetido a dois ciclos de irradiação pelas microondas, para simular o envio da prótese ao laboratório e o retorno dela ao consultório odontológico. Cada corpo-de-prova foi irradiado a uma potência constante de 650 W, variando-se o tempo de exposição: 1 minuto (T1), 2 minutos (T2), 3 minutos (T3), 4 minutos (T4) ou 5 minutos (T5). O grupo controle (T0) foi submetido aos testes mecânicos sem ser irradiado pelas microondas. Os ensaios de resistência à flexão para todos os corpos-de-prova foram realizados em máquina MTS-810 Material Test System sob velocidade de 5 mm/minuto, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do ...(Resumo completo, clicar acesso eletônico abaixo) / Abstract: Microwave irradiation was previous suggested as an effective method for the disinfection of acrylic resins. However, little information is available concerning the effect of microwave irradiation on the mechanical properties of acrylic resins. The purpose of this study was to evaluate the effect of two cycles of a microwave disinfection procedure on the flexural strength and Vickers hardness of acrylic resins. Four autopolymerized resins (Kooliner- K, Tokuso Rebase Fast- TR, Ufi Gel Hard- UGH and New Truliner- NT) and one heat-cured resin (Lucitone 550- L) were used for preparing specimens. For each material, 48 specimens were made and equally divided into six groups. The relined specimens were submitted to disinfection procedures after polymerization and the denture base polymer specimens were stored in water for 50 l 2 hours at 37ºC l 1ºC prior to disinfection. The specimens were individually immersed in 200 mL of destilated water and microwaved twice, simulating when dentures come from the patient and before being returned to the patient. Each cycle of microwave disinfection was performed at 650 W for one of the following irradiation times: 1 minute (T1), 2 minutes (T2), 3 minutes (T3), 4 minutes (T4) or 5 minutes (T5). Control group (T0) specimens were subjected to mechanical tests without being disinfected. The flexural strength values of the materials were determined using a testing machine MTS-810 at a crosshead speed of 5 mm/minute using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load, after 30 seconds contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. The flexural and hardness values were submitted to ANOVA and ...(Complete abstract, click electronic access below) / Mestre
137

Efetividade de vernizes fotopolimerizáveis experimentais na redução da hidrofobicidade e adesão de Candida albicans em uma resina para base de prótese /

Lazarin, Andréa Azevedo. January 2009 (has links)
Resumo: Foi proposto avaliar diferentes vernizes experimentais, que apresentam em sua formulação monômeros hidrofílicos ou zwiteriônicos, como método para modificar a superfície de resina acrílica para base de prótese, com o objetivo de prevenir a adesão de C. albicans. Foram confeccionados corpos-de-prova com características superficiais que simulavam a parte polida das próteses (superfície lisa) e com características superficiais que simulavam a parte interna das próteses (superfície rugosa) utilizando-se uma resina para base de prótese específica para micro-ondas (Vipi Wave). Matrizes metálicas com 10 cavidades (13,8 mm de diâmetro e 2 mm de altura) foram incluídas em mufla, entre 2 placas de vidro, para simular a superfície lisa, ou em contato com gesso para obter amostras que simulassem a superfície rugosa da prótese. Todos os corpos-de-prova foram submetidos à mensuração da rugosidade utilizando-se um rugosímetro (Mitutoyo SJ 400) com cutoff de 2,5 mm. A rugosidade superficial foi determinada (Ra-µm) pela média de três mensurações realizadas em cada amostra. Após a leitura da rugosidade, os corpos-de-prova foram divididos em grupo controle (n=72; 36 lisos e 36 rugosos), não recebendo nenhum tratamento superficial, e 12 grupos experimentais (n=72; 36 lisos e 36 rugosos) que receberam uma camada do verniz experimental sendo polimerizado em forno EDG. Os vernizes experimentais apresentaram em sua composição o monômero metil metacrilato (MMA), dois agentes de ligação cruzada (TEGDMA e Bis-GMA) e o foto iniciador MBP (4- metil benzofenona). Além desses componentes, os vernizes identificados pelos códigos P, E e T apresentaram monômeros hidrofílicos em 3 concentrações (25, 30 e 35%). O verniz identificado pelo código M apresentou um monômero zwiteriônico (MZ), nas mesmas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the use of different experimental varnishes containing zwitterion or hydrophilic monomers as a manner to modify the surface characteristics of a denture base resin and prevent the adhesion of C. albicans. For such purpose, specimens with surface characteristics that simulated the polished side of the dentures and the inner side of the dentures were fabricated using a microwave-polymerized denture base acrylic resin (Vipi Wave). Hollow metallic matrices with 10 cavities (13.8 mm diameter x 2 mm high) were flasked either between two glass plates, in order to produce specimens with smooth surfaces that simulated the polished side of the dentures, or in direct contact with the stone, in order to obtain specimens with rough surfaces that simulated the inner side of the dentures. All specimens were subjected to surface roughness readings in a roughness meter (Mitutoyo SJ 400) with cutoff length of 2.5 mm. Surface roughness (Ra, µm) was determined as the average of three random measurements made on each specimen. After the roughness readings, the specimens were randomly assigned to one control group (n=72; 36 smooth and 36 rough specimens), in which the specimens received no surface treatment, and 12 experimental groups (n=72; 36 smooth and 36 rough specimens) in which the specimens were coated with one of the experimental varnishes followed by polymerization in an EDG oven. The 12 experimental varnishes presented in their composition the monomer methyl methacrylate (MMA), two crosslinking agents (TEGDMA and Bis-GMA) and a photoinitiator agent (4-methyl benzophenone . MPB). In addition to these components, the experimental varnishes labeled as P, E and T presented hydrophilic monomers at three concentrations (25, 30 and 35%). The experimental varnish labeled as M presented a zwitterion... (Complete abstract click electronic access below) / Orientador: Ana Lucia Machado / Coorientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Marco Antonio Compagnoni / Banca: Dalva Cruz Laganá / Banca: Cláudia Helena Lovato da Silva / Doutor
138

SITUACE VZTAHU MATKY S DCEROU A JEHO VÝTVARNÉ ZTVÁRNĚNÍ / THE ARTISTIC RENDERING OF MOTHER AND DAUGHTER RELATIONSHIP

HEJDOVÁ, Petra January 2009 (has links)
The presented diploma thesis focuses on artistic rendering of my relationship with mother, mainly in terms of colour expression, which I see as crucial. The work is divided into two parts, the practical part and the theoretical one. The theoretical part deals with psychology of colours and their impact on a human being. The practical part consists of six large-scale acrylic paintings painted on canvas, description of my individual artistic development and sources of inspiration.
139

Influência de imersões em vinagre sobre a rugosidade e a dureza de uma resina acrílica de termoativação / Influence of vinegar immersions at surface roughness and microhardness of one thermo cured acrylic resin

Jiménez Pereira, Cláudia January 2014 (has links)
Diversas substâncias químicas têm sido utilizadas no processo de desinfecção e higiene de dispositivos de resina acrílica, no entanto, muitas destas substâncias são utilizadas de forma empírica. Sendo assim, o objetivo do presente estudo foi avaliar a influência da imersão em vinagre, hipoclorito de sódio e peróxido de hidrogênio na rugosidade e na dureza de uma resina acrílica de termoativação Meliodent® Heat Cure (Heraeus Kultzer, Alemanha). Foram confeccionados 130 corpos de prova de resina acrílica e estes foram aleatoriamente divididos em 13 grupos (n=10). O grupo controle permaneceu a seco, sem imersão. Os grupos teste foram submetidos à imersão em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada por diferentes tempos (30h, 150h ou 300h). As soluções foram protegidas da luz e trocadas a cada período de 24 horas. Após o período de imersão foram avaliadas a microdureza Knoop e a rugosidade Ra da resina acrílica. A microdureza Knoop dos corpos foi obtida com o microdurômetro automático HMV-2 (Shimadzu, Japão) sendo utilizada a medida de cinco mensurações em cada corpo de prova com uma carga de 25g por 10 segundos. A rugosidade Ra foi determinada pela media de cinco leituras realizadas em cada corpo de prova, utilizando-se um Rugosímetro SJ-201 (Mitutoyo, Japão). Os resultados mostraram que houve diferença estatisticamente significativa na microdureza da resina acrílica de termopolimerização após a imersão durante 30h, 150h e 300 h em vinagre, hipoclorito de sódio 1%, peróxido de hidrogênio 10V e água destilada, quando comparado com o grupo controle, que permaneceu a seco. Os resultados da rugosidade não mostraram diferença estatisticamente significativa após a imersão durante 30h, 150h e 300h em vinagre e água destilada quando comparados com o grupo controle, sem imersão. Com base no desenho experimental e nos resultados do presente estudo é possível concluir que o vinagre pode se tornar uma opção para desinfecção caseira de dispositivos de resina acrílica. / Several substances have been used for the disinfection and hygiene of acrylic resin devices, however, many of these substances are used empirically. Thus, the aim of this study was to evaluate the influence of immersion in vinegar, sodium hypochlorite and hydrogen peroxide on the surface roughness and hardness of thermo-cured acrylic resin Meliodent® Heat Cure (Heraeus Kultzer, Germany). 130 specimens of acrylic resin were produced and randomly divided into 13 groups (n = 10). The control group remained dry without immersion. The test groups were immersed in vinegar, 1% sodium hypochlorite, hydrogen peroxide 10V and distilled water during different times (30h, 150h and 300h). The solutions were protected from light and changed every 24 hours. After the immersion period, Knoop hardness and surface roughness of the acrylic resin were evaluated. The Knoop hardness of the specimens were obtained through an automatic microhardness tester HMV-2 (Shimadzu, Japan) with five measurements on each specimen with a load of 25g for 10 seconds. The roughness was determined by five readings on each specimen using a Surface Roughness Tester SJ-201 (Mitutoyo, Japan). The results showed a statistically significant difference in microhardness after immersion for 30h, 150h and 300h in vinegar, 1% sodium hypochlorite, hydrogen peroxide and distilled water 10V, compared with the control group. The results of roughness showed no statistically significant difference after immersion for 30h, 150h and 300h in vinegar and distilled water when compared with the control group. Based on the experimental design and results of this study it can be concluded that vinegar can eventually become an option for homemade disinfecting apparatus of acrylic resin.
140

Efeitos da terapia fotodinÃmica mediada por um novo dispositivo de luz comparada a compostos quÃmicos indicados para descontaminaÃÃo da resina acrÃlica / Effects of photodynamic therapy mediated by a new light device compared to chemical compounds indicated for descontamination of acrylic resins

Janaina CÃncio de Holanda Prado 08 July 2015 (has links)
A desinfecÃÃo ou esterilizaÃÃo de dispositivos de resina acrÃlica, como prÃteses imediatas, guias e goteiras cirÃrgicas, à importante na prevenÃÃo da contaminaÃÃo do paciente por micro-organismos potencialmente patogÃnicos. As resinas acrÃlicas sÃo materiais termossensÃveis, podendo somente ser descontaminadas por meios quÃmicos ou frios. Esta dissertaÃÃo teve como objetivos fazer uma revisÃo de literatura sistemÃtica sobre a aÃÃo antimicrobiana de agentes quÃmicos em resinas acrÃlicas, alÃm de realizar um estudo experimental avaliando o efeito da terapia fotodinÃmica, mediada pelo fotossensibilizador azul de metileno a 22 &#956;M, sobre o nÃvel de contaminaÃÃo por micro-organismos presentes em prÃteses totais advindas de diferentes laboratÃrios protÃticos, bem como um novo equipamento composto por diodos emissores de luz (LEDs) de 630 nm e 1W. Para a revisÃo de literatura foram utilizados os descritores ÂÂmicroorganismsÂÂ, ÂÂdental prosthesisÂÂ, e/ou ÂÂdisinfection nas bases de dados Pubmed/ Bireme, com busca no perÃodo de 2004 a 2014, incluindo artigos em inglÃs referentes a pesquisas experimentais, comparando-se agentes quÃmicos sobre mais de uma espÃcie de micro-organismo, na superfÃcie de resinas acrÃlicas. Foi verificado que os mÃtodos apresentaram variaÃÃes nos efeitos antimicrobianos, dependendo do tempo de imersÃo, concentraÃÃo do produto e a espÃcie de micro-organismo presente. O hipoclorito de sÃdio 1%, o digluconato de clorexidina 2% e o Ãcido acÃtico apresentaram maior eficÃcia, em ordem decrescente. No estudo experimental, foram selecionadas 25 prÃteses totais superiores precedendo a instalaÃÃo nos pacientes. Em seguida, as mesmas foram aleatoriamente distribuÃdas por sorteio em quatro grupos: sem tratamento; imersÃo em digluconato de clorexidina 2% por 10 minutos; apenas irradiaÃÃo com LEDs; terapia fotodinÃmica (TFD). O circuito de controle e acionamento do equipamento composto por 8 LEDs de 1W foi desenvolvido em parceria com o LaboratÃrio de Engenharia de Sistema de ComputaÃÃo, na Faculdade de Engenharia de TeleinformÃtica da Universidade Federal do CearÃ. No grupo TFD, a irradiaÃÃo por 1 minuto ocorreu depois de 5 minutos da aplicaÃÃo do fotossensibilizador. ApÃs os tratamentos realizados, as prÃteses foram imersas em 100 ml de BHI caldo e levadas à cuba ultrasÃnica por 15 minutos. Foram coletados 5 ml deste meio de cultura para incubaÃÃo por 48 horas a 37ÂC. Em seguida, 1000 microlitros do caldo foram diluÃdos em 1:10, 1:100, 1:1000 e plaqueados em triplicada, em Ãgar Sangue, Ãgar Sabouraud Dextrose, e Hicrome UTI ÃgarÂ. As placas foram incubadas a 37ÂC por 48 horas, para posterior contagem de unidades formadoras de colÃnia (UFC/ml) e classificaÃÃo dos dados em escala ordinal. Testes de Kruskall-Wallis, Dunn, ANOVA (2 critÃrios) e Bonferroni (&#945;=0,05) foram aplicados. A TFD mostrou reduÃÃo significativa na contagem de bactÃrias totais viÃveis (p=0,0002), quando comparada ao grupo somente irradiado, e reduÃÃo significativa de fungos totais viÃveis, quando comparada aos grupos sem tratamento e somente irradiado (p=0,0002). A TFD teve efeito antimicrobiano semelhante à imersÃo em digluconato de clorexidina 2% por 10 minutos (p>0,05). As espÃcies bacterianas identificadas mais prevalentes nas prÃteses foram P. aeruginosa, K. pneumoniae e E. coli e a TFD promoveu diminuiÃÃo significativa na contagem destas espÃcies, assim como a clorexidina (p<0,001). A contaminaÃÃo de prÃteses dentÃrias advindas de laboratÃrios protÃticos foi expressiva. A terapia fotodinÃmica empregada no protocolo proposto para dispositivos de resina acrÃlica mostrou efeito antimicrobiano promissor mediante esta contaminaÃÃo. / Disinfection or sterilization of acrylic resin devices, such as immediate prostheses, surgical guides and gutters, is important in preventing the patient from contamination by potentially pathogenic microorganisms. Acrylic resins are heat-sensitive materials, which can only be decontaminated by chemicals or cold means. This study aimed at making a systematic review of literature on the antimicrobial action of chemical agents on acrylic resins. In addition, it was carried out an experimental study evaluating the effect of photodynamic therapy, mediated by methylene blue photosensitizer to 22 &#956;M, on the level of contamination by microorganisms present in dentures coming from different laboratories, and a new device consisting of light emitting diodes (LEDs) 630 nm and 1W. For the literature review, we used the descriptors microorganisms, dental prosthesis, and/or disinfection in Pubmed/ Bireme databases with search from 2004 to 2014, including articles in English on experimental studies comparing chemical agents on more than one species of microorganism in the surface of acrylic resin. It was found that methods show differences in antimicrobial effects depending on the immersion time, product concentration and type of present microorganism. Sodium hypochlorite 1%, chlorhexidine digluconate 2% and acetic acid showed greater efficacy, in decreasing order. In the experimental study, a number of 25 upper dentures were selected and installed in patients. Then, the dentures were randomly distributed into four groups: untreated; immersion in 2% chlorhexidine digluconate for 10 minutes; only irradiation with LEDs; photodynamic therapy (PDT). The control circuit and activation of equipment consisting of 8 LEDs 1W was developed in partnership with the Computer System Engineering Laboratory at the Faculty of Computer Engineering at the Federal University of CearÃ. On the PDT group, irradiation for 1 minute took place 5 minutes after application of the photosensitizer. After the treatment, the prostheses were immersed in 100 ml of BHI broth and then brought to ultrasonic tank for 15 minutes. It was collected 5 ml of this culture for incubation for 48 hours at 37  C. After that, 1000 microliter of the broth were diluted 1:10, 1: 100, 1: 1000 and plated in triplicate, on Blood Agar, Sabouraud Dextrose Agar and HiCrome UTI ÃgarÂ. The plates were incubated at 37ÂC for 48 h and then counting colony forming units (CFU / ml) and classification of data on an ordinal scale. Kruskal-Wallis test, Dunn, ANOVA (2 criteria) and Bonferroni (&#945; = 0.05) were applied. PDT showed significant reduction in count of total viable bacteria (p = 0.0002) compared to only irradiated group, and a significant reduction of total viable fungi, when compared to the only irradiated groups and untreated (p = 0.0002). PDT showed antimicrobial effect similar to immersion in 2% chlorhexidine digluconate for 10 minutes (p> 0.05). The most prevalent bacterial species identified in the prostheses were P. aeruginosa, K. pneumoniae and E. coli and PDT caused a significant decrease in counting of these species as well as chlorhexidine did (p <0.001). The contamination of dental prostheses coming from prosthetic laboratories was significant. Photodynamic therapy used in the proposed protocol for acrylic resin devices showed promising antimicrobial effect by this contamination.

Page generated in 0.0529 seconds