• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 256
  • 136
  • 18
  • 11
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 499
  • 211
  • 163
  • 117
  • 104
  • 83
  • 74
  • 71
  • 65
  • 51
  • 51
  • 49
  • 44
  • 43
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibers

Colán Guzmán, Paola del Rosario 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.
172

Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brands

Nishida, Cintia Lumi 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
173

Avaliação in vitro da ação do hipoclorito de sódio e de pastilhas efervescentes quanto à alteração de cor em resinas acrílicas termopolimerizáveis e de microondas / In vitro evaluation of sodium hypochlorite and effervescent tablets actionregarding color alteration of heat and microwave-polymerized acrylic resins

Peracini, Amanda 10 July 2008 (has links)
O objetivo deste estudo foi avaliar a alteração de cor de resinas acrílicas termopolimerizáveis (convencional e de microondas) após imersões em soluções químicas higienizadoras de próteses totais em diferentes períodos de tempo. Foram obtidos padrões em cera (15mm de diâmetro e 4mm de espessura), a partir de uma matriz de teflon, que foram incluídos em muflas convencionais e para microondas. Após a eliminação da cera, as resinas foram manipuladas, prensadas e polimerizadas segundo as instruções dos fabricantes. Foram confeccionados 200 corpos-de-prova, 100 de cada marca comercial das resinas Lucitone 550 (L) e Onda Cryl (OC), os quais foram imersos nas soluções: A)Água destilada-3 min.; B)Bony Plus -3 min.; C)Água destilada-5 min.; D)Corega Tabs-5 min.; E)Água destilada-20 min.; F)Hipoclorito de sódio a 0,5%-20 min.; G)Hipoclorito de sódio a 1%-20 min.; H)Água destilada-8 horas; I)Hipoclorito de sódio a 0,5%-8 horas; J)Hipoclorito de sódio a 1%-8 horas. A alteração de cor foi avaliada empregando-se um espectrocolorímetro (Color Guide 45/0 BYK-Gardner) antes e após a simulação de 180 dias de imersão. Os resultados foram comparados por meio da análise de variância (ANOVA) para dois fatores, seguida pelo teste de Student-Newman Keuls, com nível de significância de 0,05. Para correlacionar as diferenças de cor para o ambiente clínico, os dados foram calculados de acordo com as unidades da National Bureau of Standards (NBS). Os resultados mostraram que a resina Lucitone 550 (&Delta;E = 0,47±0,18) apresentou-se mais estável que a Onda-Cryl (&Delta;E = 0,53±0,31). Para ambas as resinas, as pastilhas, os hipocloritos por 20 minutos (0,5% e 1%) e por 08 horas (0,5%) não provocaram alterações maiores que seus respectivos controles (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). As soluções de hipoclorito a 1% (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) causaram maiores alterações que seus respectivos controles. As soluções empregadas por 08 horas (água e Hipocloritos a 0,5% e 1%) provocaram alterações classificadas como leves, segundo o sistema NBS. Os achados deste estudo revelaram que as pastilhas efervescentes, quando usadas de acordo com as instruções dos fabricantes, e o hipoclorito de sódio (0,5% e 1%) por 20 minutos apresentaram menores valores de alteração de cor nas resinas acrílicas após um período de uso simulado de 180 dias. Médias mais elevadas foram obtidas quando um regime de 8 horas foi simulado. / The aim of this study was to evaluate color alteration of heat-polymerized acrylic resins (conventional and microwave-polymerized), after immersion in chemicals solutions of denture cleansers for different periods of time. Wax patterns were obtained (15 mm in diameter and 4 mm thickness) from a teflon matrix and were invested in metallic or microwavable flasks. The wax had been eliminated and the resins were mixed, packed and polymerized according to the manufacturers instructions. Two hundred specimens were made, 100 specimens of each commercial resin Lucitone 550 (L) e Onda Cryl (OC), which were immersed in the solutions: A)Distilled water-3 min.; B)Bony Plus-3 min.; C)Distilled water-5 min.; D)Corega Tabs-5 min.; E) Distilled water -20 min.; F) 0,5% Sodium Hypochlorite-20 min.; G) 1% Sodium Hypochlorite-20 min.; H)Distilled water-8 hours; I)0,5% Sodium Hypochlorite-8 hours; J)1% Sodium Hypochlorite -8 hours. Color alteration was assessed by a spectrocolorimeter (Color Guide 45/0 (BYKGardner) before and after 180 days simulation. The results were analyzed statistically by a two-way analysis of variance (ANOVA), and Student Newman-Keuls test, with significance level of 0.05. To relate the color differences to a clinical environment, the data were quantified by National Bureau of Standards (NBS) units. The results showed that the resin Lucitone 550 (&Delta;E=0,47±0,18) was more stable than the resin Onda-Cryl (&Delta;E=0,53±0,31). For both resins, the tablets, the hypochlorite by 20 minutes (0,5% e 1%) and by 8 hours (0,5%) did not produce higher alterations than the respective controls (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). The 1% hypochlorite solutions (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) produced higher alterations than the respective controls. The solutions employed by 8 hours (water and 0,5% and 1% hipochlorite) produced alterations classified as slight, according to the NBS system. The findings of this study showed that the effervescent tablets, used according to the manufacturer´s instructions, and the sodium hypochlorite (0,5% and 1%) used by 20 minutes presented lower values of color alterations in acrylic resins after a period of 180 days simulation. Higher mean averages were obtained when a period of 8 hours was simulated.
174

Influência da Formulação das tintas de base acrílica como barreira contra a penetração de agentes agressivos nos concretos. / Sem título em inglês.

Uemoto, Kai Loh 18 August 1998 (has links)
Uma forma de reduzir a difusão de agentes agressivos para o interior do concreto é através da aplicação de sistemas de pintura, que funcionam como uma barreira ao ingresso destes agentes. A difusão dos agentes através de películas de pintura está relacionada com a sua porosidade, que, por sua vez, depende principalmente do teor e estrutura química da resina e do teor e morfologia dos pigmentos. Esta tese teve por objetivo principal demonstrar que, com uma formulação adequada, as tintas à base de resina acrílica podem ser utilizadas como barreira de proteção eficiente contra a penetração de água e vapor de água, anidrido carbônico (C\'O IND.2\') e íons cloreto, em estruturas de concreto ou em outros tipos de substratos. As formulações das tintas foram definidas em função do tipo de acabamento final e obtidas pela variação da relação pigmento/resina. Foram realizados ensaios de caracterização nas tintas líquidas e nas resinas utilizadas na preparação das tintas estudadas, bem como ensaios de desempenho nas películas livres e em concretos pintados, que apresentavam resistência à compressão de 20 e 40 Mpa. Para a medida da resistência à penetração dos agentes agressivos no concreto, foram desenvolvidos ensaios acelerados, com base em metodologias de avaliação de argamassas e concretos, adaptados a substratos pintados. A microestrutura das películas de tinta foi correlacionada com as propriedades físicas das películas e dos concretos pintados. Os resultados obtidos mostram a importância da formulação das tintas nos fenômenos de transporte e, além disso, mostram que tintas acrílicas e as estirenoacrílicas com diferentes temperaturas vítreas (Tg) apresentam comportamento físico distinto. Tintas de acabamento semi-brilho conferem boa proteção contra a penetração de agentes agressivos no concreto, enquanto que as de acabamento fosco apresentam função mais decorativa do que de proteção. / The diffusion of aggressive agents into concrete can be reduced by the application of painting systems which work as barriers to these agents. The capacity of these agents to pass through the paint is related to its porosity, which in turn is mainly dependent on the structure and content of the resin and on the morphology and content of the pigments. The main objective of this thesis is to demonstrate that with adequate formulation, paints based on acrylic resin polymers can be used as efficient barriers against the penetration of water and water vapour, carbon dioxide and chloride in concrete structures or any other porous substrate. Paint formulations were defined based on the final appearance (gloss) and obtained by varying the pigmentbinder ratio. Characterization tests on the liquid paints and polymers prepared for this study were done, as were performance tests on free dry films and painted concrete substrates, with compressive strength of 20 MPa and 40 MPa. In order to determine the effectiveness of paint in inhibiting the diffusion of aggressive agents into concrete, accelerated tests based on methodologies for the evaluation of mortars and concrete were developed. The films microstructures were correlated with their physical properties and with painted concrete. The results showed that the formulation of the paints has a important effect on the transport mechanism and also that acrylic and styrene-acrylic paints with different transition temperatures (Tg) do not present the same physical behavior. Glossy paints presented a high level of protection against the penetration of aggressive agents whereas matte finishes offered a more aesthetic function rather than protection.
175

"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono mer

Paes Junior, Tarcisio José de Arruda 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 – grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições – à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 – control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
176

Confecção de lentes acrílicas para o ensino de ótica / Development of acrylic for optics education

Cruz, Renato Antonio 23 July 1997 (has links)
A grande carência de material experimental adequado para o ensino de Ótica no Brasil motivou o desenvolvimento de um processo de moldagem de lentes acrílicas, pelo Centro de Divulgação Científica e Cultural. Aproveitando tecnologia já existente na Universidade, o CDCC desenvolveu um processo de moldagem por compressão, relativamente barato, utilizando a placa acrílica comercial como material moldável. O presente trabalho consiste em caracterizar e avaliar esse processo de moldagem de lentes acrílicas. Para tanto, são levantadas as principais características físicas do material moldável. A qualidade ótica da lente moldada é analisada com base em alguns ensaios, tais como medidas de aberrações geométricas e de birrefringência induzida. Os resultados obtidos permitem a determinação dos parâmetros ideais do processo, e demonstram a possibilidade de obtenção de lentes acrílicas de excelente qualidade ótica para o ensino básico, a um custo acessível. / The necessity of experimental optical materials in Brasil for basic learning was the principal motivation for the development of the process to produce acrylic lens in the Centro de Divulgação Científico e Cultural (CDCC). All the process developed use low cost commercial acrylic and a moulding procedure to produce the lens. In this work we characterize the moulding process and the physical properties for the material. The optical quality for the moulding lens was determine measuring: aberrations and the induce birefringence. These results allow us to determine the optimal parameters for the process, and the possibility to production of high quality lens for the basic schools.
177

Preparação de placas rígidas de polpa celulósica e de nanofibras de celulose com polímeros acrílicos / Preparation and characterization of rigid panels of wood cellulose pulp and nanocellulose with acrilic polymers

Chiromito, Emanoele Maria Santos 28 July 2016 (has links)
No presente trabalho, foram preparados painéis rígidos compostos de polpa celulósica e nanofibras de celulose (NFC), utilizando como materiais aglomerantes o poli (metacrilato de metila) (PMMA) e uma resina acrílica comercial, empregados em suspensões aquosas do material celulósico e emulsões dos polímeros aglomerantes. Foi desenvolvido um novo método para a preparação dos materiais compósitos baseados em um processo de co-precipitação, onde o reforço de fibras de celulose e o polímero em emulsão são coagulados e isolados da fase aquosa. Foram investigadas misturas de resina/fibra contendo 25%, 50% e 75% de fibras em massa. O grande desafio encontrado foi a obtenção de dispersões homogêneas das fibras nas matrizes acrílicas, uma vez que a natureza hidrofílica da celulose em relação a natureza hidrofóbica das matrizes geralmente leva a separação entre os componentes e a formação de materiais heterogêneos. O processo estudado neste trabalho, conduziu à formação de placas espessas e homogêneas que foram moldadas por prensagem à quente. Os materiais foram caracterizados por meio de ensaios de espectroscopia no infravermelho com transformada de Fourier (FTIR), análise termogravimétrica (TGA), ensaio dinâmico mecânico (DMA), ensaio de tração, absorção de água e microscopia eletrônica de varredura (MEV). As micrografias obtidas por MEV mostraram uma boa dispersão e adesão interfacial das NFC com os materiais acrílicos. Os ensaios de DMA e ensaios de tração evidenciaram o efeito de reforço superior NFC em relação a polpa celulósica. O comportamento dos compósitos obtidos com as NFC foi muito superior do que comportamento dos painéis obtidos com a polpa de celulose. O método desenvolvido para a produção de placas de polímeros acrílicos com altos teores de fibras de celulose se mostrou eficaz, sendo demonstrado o potencial das NFC como material de reforço. / In this work, there were prepared rigid panels of poly (methyl methacrylate) (PMMA) and a commercial acrylic resin reinforced with wood pulp and cellulose nanofibers (NFC). Wood pulp and cellulose nanofibers were used from its aqueous suspensions and the thermoplastic polymers used as emulsions. A new method for the preparation of composite materials based on a co-precipitation in which the reinforcement fibers of cellulose and polymer emulsion were coagulated and isolated from the aqueous phase has been developed. Thus, mixtures of resin/fiber containing 25%, 50% and 75% by weight fibers have been investigated. The challenge found to obtain homogenous dispersion of fibers in an acrylic resin matrix, since the hydrophilic nature of the cellulose compared to hydrophobic nature of matrices usually leads to separation of the components and the formation of heterogeneous materials. The process studied in this work led to the formation of thick and homogeneous composites in which were molded by hot pressing. The materials was characterized by Fourier transform infrared spectroscopy (FTIR) thermogravimetric analysis (TGA), dynamical mechanical analysis (DMA), tensile testing, water absorption and scanning electron microscopy (SEM). The SEM micrographs showed good dispersion and interfacial adhesion of NFC with acrylic materials. DMA tests and tensile tests showed higher reinforcing effect NFC in relation to pulp. The method developed for the production of acrylic polymers panels with high cellulose fibers content is effective, being demonstrated the potential of NFC as reinforcing material. The behavior of the panels obtained with NFC was very behavior of the composites obtained from the wood pulp cellulose.
178

Resina acrílica implementada na tecnologia CAD-CAM: análise longitudinal e comparativa da rugosidade superficial e microdureza após sucessivos ciclos de termociclagem / The superiority of the CAD-CAM acrylic resins: myth or a reality?

Costa, Rodrigo Moreira Bringel da 16 October 2018 (has links)
As propriedades de rugosidade superficial e microdureza são reconhecidas como propriedades muito relevantes no que concerne ao tratamento com prótese total removível, estando associadas ao desgaste da prótese e à sua predisposição à colonização por microrganismos. A proposição deste estudo foi realizar uma análise longitudinal e comparativa, destas duas propriedades, entre uma nova resina acrílica (Vipi Block Gum) para bases de próteses totais removíveis, implementada na tecnologia CAD-CAM, e duas resinas acrílicas termopolimerizáveis, sendo uma convencional (Vipi Cril Plus) e outra polimerizada por ação de micro-ondas (Vipi Wave), antes e após a aplicação de sucessivos ciclos de envelhecimento térmico por temociclagem, de modo a investigar a existência de uma correlação entre o processo de polimerização e o desempenho do material. Para isto, foram confeccionados um total de 60 corpos de prova com formato quadrangular com dimensões de 12x12x3mm, sendo destinados 20 corpos de prova para cada material. Para cada resina, 10 corpos de prova foram destinados ao teste de microdureza Knoop (KHN) e os outros 10 corpos de prova foram submetidos ao teste de rugosidade superficial (Ra-m). As análises dos corpos de prova, para ambos os experimentos, foram realizadas em quatro estágios distintos. As primeiras leituras foram realizadas após imersão dos materiais em água deionizada a 37ºC durante 24 horas (T1), com subsequentes análises após a aplicação de 500 ciclos (T2), 1000 ciclos (T3) e 3000 ciclos (T4) de termociclagem, com temperaturas de 5ºC a 55ºC com duração de 60 segundos para cada banho. Na avaliação estatística, a comparação das médias entre os grupos de resinas foi realizada com o teste de análise de variância (ANOVA) de um critério sendo, seguido do teste de Tukey. Para a comparação interna de cada grupo, em relação ao estágio de termociclagem, foi utilizado um ANOVA de medidas repetidas. O nível de significância adotado foi de 5%. Não houve diferença estatisticamente significante, na comparação intragrupos e intergrupos, em relação à rugosidade superficial (p>0.05). Na análise comparativa da microdureza entre os grupos, foi observada diferença estatisticamente significante nas análises em T1 e T2, com a resina Vipi Block obtendo valores superiores às outras resinas (p=0.00). Em T3, observou-se uma redução significativa da microdureza de todas as resinas, sendo mais pronunciada na resina Vipi Block Gum, tendo esta sido estatisticamente superior apenas em relação à Vipi Wave (p=0.01). Em T4 foi observado um aumento significativo na resina Vipi Cril Plus, com diferença estatisticamente significante (p>0.05) em relação às outras resinas. Na análise interna de cada grupo, foram observadas interações estatisticamente significantes em todas as resinas (p<0.05). A resina Vipi Block Gum teve sua microdureza drasticamente reduzida em T3, mantendo-se similar em T4, sendo significativamente inferiores (p<0.05) aos valores obtidos em T1 e T2. A resina Vipi Cril Plus sofreu uma acentuada redução na comparação em T1 em relação a T3 (p=0.021). Em T4, tornou-se estatisticamente superior a todos os outros períodos (p<0.05). A resina Vipi Wave sofreu redução significativa de T2 para T3 (p=0.01). Semelhantemente, obteve um aumento em T4, tornando-se estatisticamente superior a T3 (p=0.01). / Superficial roughness and microhardness are considered as extremely relevant properties which directly affects treatments with complete removable dentures, being them related to wear, and to the vulnerability of these prostheses to be colonized by microorganisms. The objective of this study was to perform a longitudinal analysis of these properties, making a comparison between a new CAD-CAM denture base acrylic resin (Vipi Block Gum), a conventional heat-polymerized and a microwave-polymerized resins, before and after the application of successive thermocycling cicles, in order to investigate a possible higher performance presented by the Vipi Block Gum resin. Sixty quadrangular shaped specimens with dimensions of 12x12x3mm were made and were equally divided between the three resins. For each material, 10 specimens were destined to the surface roughness analysis (Ra-m) and the other 10, for the Knoop microhardness (KHN) evaluation. The firsts analyses were performed after a 24-hour period of immersion in distilled water at 37ºC (T1), with subsequent analyses after 500 cicles (T2), 1000 cicles (T3) and 3000 cicles (T4) of thermocycling, with temperatures ranging from 5ºC to 55ºC and with 60 seconds of immersion, for each temperature. The statistical analysis, for the intergroup comparison, was done by applying a one-way analysis of variance (ANOVA) test, seconded by Tukeys posthoc test. For the intragroup analysis, a repeated measures ANOVA was applied. A significance level of 5% was adopted for both analyses. There were no significant differences for both intragroup and intergroup comparisons concerning the superficial roughness (p>0.05). The intergroup microhardness analyses showed significant differences at T1 and T2 (p=0.00), with higher values presented by the Vipi Block Gum resin when compared to the other groups. At T3, it was noticed a significant reduction for all materials, although it was more pronounced in the Vipi Block Gum resin, with this group having higher values than the Vipi Wave group (p=0.01). The comparison at T4 showed significant higher values presented by the Vipi Cril Plus in relation to the other groups (p<0.05). The intragroup analyses exhibited statistical significant differences for all materials (p<0.05). Vipi Block Gum resin suffered a significant decrease on its microhardness at T3, which remained similar at T4. However, these values were significant below (p<0.05) the ones obtained at T1 and T2. Vipi Cril Plus group showed a significant decrease at T3 in comparison with T1 (p=0.021). However, it increased significantly at T4 having statistical higher values than all other periods (p<0.05). Vipi Wave group suffered an expressive decrease at T3 in comparison with T2 (p=0.01). It also had an increase on its microhardness at T4, with statistical higher values than the ones observed at T3 (p=0.01).
179

The Incorporation of Vinyl Modified Regenerated Starch Nanoparticles in Emulsion Polymerizations

Cummings, Shidan January 2017 (has links)
The replacement of synthetic polymers with renewable content in emulsion polymerization latexes has been a focus of research over the past several decades. Emulsion polymerization is a more sustainable way to produce polymers for films and resins. Starch is a sustainably sourced material that has proven to be extremely useful as a filler, comonomer, and property modifier for polymer latexes. In this thesis, we attempt to incorporate high levels of starch materials into emulsion latex using waxy and dent sourced (cheaper) vinyl-functionalized regenerated starch nanoparticles (RSNPs). When fed as a batch charge, incorporation (by reaction as opposed to blending) of a grade of waxy RSNPs with 3 wt.% polymerizable sugar-based monomer (PSBM) and medium hydrophobicity (S-3-M) into the polymer matrix was 0-10 wt.% for a 15 wt.% RSNP loaded, 40 wt.% solids latex. Semi-batch feeding of the S-3-M RSNPs resulted in stable latex with the highest loadings of 40 and 50 wt.% (40 wt.% solids) with 0-10 wt.% RSNP incorporation into the synthetic particles, while 40 wt.% loading (20 wt.% incorporation) was achieved with a grade of waxy RSNPs with 6 wt.% PSBM and medium hydrophobicity (S-6-M). Strategies were developed to prepare synthetic latexes with high RSNP loadings and moderate incorporation. Dent sourced RSNPs proved difficult to use in emulsion formulations due in part to the higher percentage of water-soluble linear amylose in the nanoparticles. To reduce the chances of coagulation and minimize the viscosity of the final latex it was important to ensure monomer starved conditions, that the only initiator feed occurred at the seed stage of the reaction (to degrade the soluble starch and prevent later stage coagulation), and that a hydrophobic tie-layer was used to assist in removal of soluble starch from the water phase. Although a successful procedure was devised for creating a dent sourced RSNP loaded latex with a viscosity of 250 cp, it was significantly longer than the procedures used with waxy RSNPs (6 h polymerization + 1 h RSNP dispersion). An additional treatment of the RSNP dispersion prior to the polymerization can lower the final latex viscosity to 100 cp. Higher incorporation of vinyl-functionalized RSNPs may be achievable if the covalently bonded PSBM functional groups are resistant to hydrolysis, the amylose and other small MW starches are completely removed from the water phase, and monomers with more appropriate reactivity and hydrophobicity are employed. To this end, maleic and methacrylic anhydride modified RSNPs were prepared and tested in emulsion polymerizations. The maleic anhydride modified RSNPs were successfully loaded into an emulsion latex at 15 wt.% (40 wt.% solids content) resulting in 20-30 wt.% incorporation when utilizing 2-ethylhexyl acrylate as the tie-layer monomer with 2-ethylhexyl acrylate or butyl acrylate/methyl methacrylate/acrylic acid as the shell layer. This work presents the only comprehensive attempt to incorporate RSNPs into synthetic latexes at high loadings and solids with persulfate initiation without the need to severely reduce the RSNP molecular weight. The learning generated provides a framework for continuing research into increasing the incorporation of RSNPs into polymer particles.
180

Avaliação do comportamento mecânico de próteses fixas provisórias durante e após ensaio de fadiga - efeito de três tipos de reforços (fibra de vidro, fibra de aramida e fio de aço) e duas extensões de pôntico (12,5 e 22,75mm)

Bastos, Luiz Gustavo Cavalcanti 27 June 2006 (has links)
A importância das próteses provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a execução destas restaurações, entretanto, são críticos com relação à resistência e à longevidade, principalmente quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. A proposta deste trabalho foi determinar através de um ensaio de fadiga e de um teste de resistência à fratura, o efeito do tipo de reforço: fio de aço Ø 0,7 mm, fibra de poli(aramida) (Kevlar®, DuPont - USA) e fibra de vidro (Fibrante®, Ângelus -Brasil) e de duas extensões do pôntico (12,5 e 22,75 mm) sobre o comportamento mecânico de espécimes simulando próteses provisórias. Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo CONTROLE, sem reforço. Os espécimes simulando próteses parciais fixas provisórias foram confeccionados em resina auto-polimerizável com auxílio de uma matriz de aço simulando preparos totais protéticos. As amostras foram submetidas a 10.000 ciclos de fadiga, com carga máxima de 100 N, imersas em água a 37ºC. Através da análise estatística dos resultados observou-se que durante o ensaio de fadiga: 1) quando a extensão do pôntico foi de 22,75 mm, o grupo CONTROLE exibiu uma maior deformação a partir de 500 ciclos. Não foram observadas diferenças quando a extensão do pôntico foi de 12,5 mm. Houve um aumento da deformação em função do número de ciclos para todos os grupos, principalmente para o grupo CONTROLE, de ambas as extensões de pôntico; 2) Somente espécimes do grupo CONTROLE com extensão do pôntico de 22,75 mm demonstraram fraturas à fadiga. E após o ensaio de fadiga, através de um teste de resistência à fratura: 1) Quando a extensão do pôntico foi de 12,5 mm todos os grupos reforçados apresentaram valores médios do limite de elasticidade, em N, significantemente maiores que os demonstrados pelo grupo CONTROLE. Para a extensão do pôntico de 22,75 mm os valores desse parâmetro apresentaram semelhança entre todos os grupos; 2) Em relação à carga máxima (resistência à fratura), quando a extensão do pôntico foi de 12,5 mm o grupo FIBRANTE exibiu o maior valor médio. Quando a extensão do pôntico foi de 22,75 mm, observou-se que o grupo KEVLAR apresentou valores semelhantes neste parâmetro ao grupo FIBRANTE. O grupo CONTROLE sempre apresentou os menores valores médios em ambas as extensões de pôntico. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo parcial (coesiva da resina sem fratura ou separação do reforço). / Provisional restorations are essential components of oral rehabilitation treatment. The strength and durability features are, however, critical when long-term treatment is needed. This study investigates the mechanical alterations under and after cyclic fatigue in provisional partial fixed denture specimens. Two pontic distances (12.5 mm and 22.75 mm) and three types of reinforcements constituted the experimental groups with ten specimens each: a 0.7 mm of diameter wire; a roving poliaramid fiber Kevlar® and a roving fiberglass Fibrante® (Angelus®). The control group, also with ten samples, included not reinforced specimens. Specimens were fabricated and testing on metal dies. The samples were subjected to 10,000 fatigue cycles with a 100 N maximum load in a MTS 810 Universal Machine and before they were subjected to fracture resistance test in the same machine. Statistical analysis showed that, during the fatigue cycles: 1) All the samples exhibited an increased deflection, in mm, following the fatigue cycles, mainly the CONTROL group; 2) Only specimens of the CONTROL group exhibited fracture due to fatigue cycle. After the fatigue cycle, through the fracture resistance test: 1) All reinforced samples with the pontic distance of 12.5 mm exhibited higher figures in elastic limits than the CONTROL group, and increased the pontic distance to 22.75 mm the results of the elastic limits decreased statistically; 3) the FIBRANTE group with pontic distance of 12.5 mm exhibited the higher results for the resistance fracture. The CONTROL group specimens, with both pontic distances, exhibited the lowest values of this property; 4) It was observed that the reinforced FIBRANTE anda KEVLAR groups specimens fractures were more favorable, occurring, predominantly, in the Partial type.

Page generated in 0.0349 seconds