• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 51
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 211
  • 211
  • 146
  • 104
  • 64
  • 63
  • 57
  • 42
  • 41
  • 26
  • 25
  • 25
  • 25
  • 24
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável

Gonçalves, Andréa [UNESP] 04 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-04Bitstream added on 2014-06-13T20:06:12Z : No. of bitstreams: 1 goncalves_ar_dr_arafo.pdf: 1974874 bytes, checksum: cb90cfb07e456ba101c0f7c18597c3d6 (MD5) / Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros... / This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below)
132

Caracterização de resinas para base de prótese e reembasamento: propriedades físico-químicas e mecânicas

Lombardo, Carlos Eduardo Leão [UNESP] 18 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-18Bitstream added on 2014-06-13T18:45:59Z : No. of bitstreams: 1 000734874.pdf: 3245721 bytes, checksum: 5e29c8eb8d0c16d8749e92a8b44a94d0 (MD5) / Este estudo avaliou propriedades físico-químicas e mecânicas de resinas para base de prótese, uma fotoativada (Eclipse - E) à base de UDMA e outra termicamente ativada por micro-ondas (Nature Cryl MC - NC) à base de PMMA, e um reembasador quimicamente ativado (Tokuyama Rebase Fast II - TR II) à base de PEMA. Propriedades viscoelásticas (E’, tan δ e Tg), contração linear de polimerização (CLP), sorção (Sor) e solubilidade (Sol) em água e em saliva artificial, grau de conversão (GC) e coeficiente de inchamento (CI) foram avaliados para a caracterização dos polímeros. A resistência à flexão dos materiais intactos (E, NC, TR II) e reembasados (E-E, E-TRII, NC-NC- NC-TR II) também foi avaliada. As propriedades viscoelásticas foram avaliadas em corpos-de-prova retangulares (64 x 10 x 3,3 mm), submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em dois ciclos de varredura após confecção (controle) e armazenagem em saliva. O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37 ºC e a temperatura de transição vítrea (Tg) foram registrados durante o 1º ciclo da DMTA. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). O coeficiente de inchamento foi realizado (n=5) de acordo com a teoria de Flory-Rhener. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Os dados foram avaliados por ANOVA, seguida por Tukey HSD (α=0,05) ou Dunnett (α=0,05). As resinas E e NC apresentaram similar E’, superior a TR II... / This study evaluated the physical-chemical and mechanical properties of denture base resins, one UDMA light-activated (Eclipse-E) and one PMMA heat-polymerized (Nature Cryl MC - NC). The PEMA autopolymerizing reliner (Tokuyama Rebase Fast II - TR II) was also evaluated. Viscoelastic properties (E’, tan δ e Tg), linear shrinkage polymerization (LPS), sorption (Sor) and solubility (Sol) in water and in artificial saliva, degree of conversion (DC) and coefficient of swelling (CS) were employed for polymer characterization. The flexural strength of intact (E, NC, TR II) and relined samples (E-E, E-TRII, NC-NC- NC-TR II) was also made. The viscoelastic properties were evaluated by two cycles of dynamic mechanical thermal analysis (DMTA) on each rectangular (64 x 10 x 3.3 mm) samples (n=2). The storage modulus (E’) and loss tangent (tan δ) at 37 ºC and the glass transition temperature (Tg) were recorded from the 1st DMTA cycle. LPS (%) was evaluated (n=10) by a Nikon 6C optical comparator, on circular samples (50 x 0.5 mm). Sor and Sol (μg/mm3) were measured (n=6) according to ISO 1567. DC (%) was evaluated (n=5) by FTIR spectroscopy (32 scans; resolution 4.0 cm-1). CS was evaluated (n=5) by Flory-Rhener theory. A three-point flexural tests (0.5 mm/min) was applied (n=10) on rectangular intact and relined samples. The ultimate flexural strength (FSU) and the flexural strength at the proportional limit (FSPl) were recorded in MPa. Data were analyzed with ANOVA, followed by Tukey HSD (α=0.05) ou Dunnett (α=0.05). E and NC had similar E’, higher than TR II. Tan δ was arranged as TR II > NC > E. The Tg was not affected after saliva storage. The higher Tg values were obtained for E and NC. Tan δ peaks were shifted after 2 DMTA cycles. Regardless the medium immersion, Sor (μg/mm3) was arranged as NC > E > TR II. Saliva storage reduced Sol (μg/mm3) of the materials. E showed the lowest values of LPS, CS and...
133

Movimentação dos dentes artificiais em próteses totais com diferentes profundidades de palato

Vedovatto, Eduardo [UNESP] 25 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-25Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 vedovatto_e_dr_araca.pdf: 365938 bytes, checksum: bd1dd616abe7c6a4bce474ab109acd1f (MD5) / Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato... / Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey's and Fisher's post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical... (Complete abstract click electronic access below)
134

Efeito do tratamento térmico em microondas e do tempo de armazenamento em água sobre a citotoxicidade de resinas acrílicas para base e reembasamento de próteses

Jorge, Janaina Habib [UNESP] 15 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-15Bitstream added on 2014-06-13T19:45:08Z : No. of bitstreams: 1 jorge_jh_dr_arafo.pdf: 867417 bytes, checksum: c6b45e8ab940eca12be6f09afd58b08f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / A proposta do presente estudo foi avaliar, por meio do teste quantitativo de incorporação de 3H-timidina, o efeito do tratamento térmico em microondas sobre a citotoxicidade de três resinas termopolimerizáveis indicadas para confecção de bases de próteses, em função do tempo de armazenamento em água, e de três resinas autopolimerizáveis indicadas para reembasamento. A hipótese de que o tratamento térmico em microondas poderia diminuir a citotoxicidade de resinas acrílicas foi avaliada. Os materiais testados foram Lucitone 550 (a mufla foi imersa em água à temperatura de 730C permanecendo por 90 minutos, em seguida, à temperatura foi elevada para 1000C e a mufla mantida por mais 30 minutos), QC 20 (a mufla foi imersa em água em ebulição, o aquecimento foi mantido e a mufla permaneceu no recipiente por um período de 20 minutos contados a partir do momento em que a água atingiu novamente à temperatura de ebulição e Acron MC (a mufla foi levada ao forno de microondas durante 3 minutos à potência de 500 W) e os reembasadores Tokuyama Rebase II, Kooliner e New Truliner. Foram confeccionados, em condições assépticas, corpos-de-prova de cada resina em forma de discos medindo 10 mm de diâmetro e 1 mm de espessura. As amostras das resinas termopolimerizáveis foram armazenadas em água destilada por 0, 24 ou 48 horas a 37ºC. Para avaliar o efeito do tratamento térmico em microondas, os corpos-de-prova de todas as resinas foram divididos em dois grupos: 1) sem tratamento térmico e 2) com tratamento térmico em microondas, com as amostras imersas em água, irradiadas durante 3 minutos à 500 W. Os extratos das resinas foram preparados colocando-se três corpos-de-prova de cada grupo experimental, após terem recebido o tratamento térmico, em tubos de ensaio com 9 ml de meio de cultura Eagle e incubados a 37ºC por 24 horas. Um tubo de ensaio, contendo apenas 9 ml de meio... / The aim of the current study was to evaluate the effect of microwave post-polymerization heat-treatments and water storage time on the cytotoxicity of denture base and reline acrylic resins. The hypothesis that post-polymerization treatment could decrease the cytotoxicity of acrylic base resins was tested in this study. The materials tested were Lucitone 550 (water-bath at a temperature of 73ºC for 90 minutes, followed by 30 minutes of heating at 100ºC), QC 20 (boil water, insert flask, return to boil, boil for 20 minutes) and Acron MC (microwave-polymerized, irradiated for 3 minutes at 500 W) and the hard chair-side reline resin Tokuyama Rebase II, Kooliner and New Truliner. Sample disks of the denture base resins were fabricated under aseptic conditions in mold 10 mm in diameter by 1 mm thick. The samples of the denture base acrylic resins were stored in distilled water for 0, 24 and 48 hours at 37ºC. To assess the biologic effect of the heat-treatment on the denture resins, samples fabricated were further divided into two groups: 1) samples without heat-treatment; and 2) sample were treated in microwave, immersed in water, irradiated for 3 minutes at 500 W. Eluates of the materials were prepared by placing three disks into a sterile glass vial with 9 ml of Eagle's medium supplemented with antibiotics and fetal bovine serum. These were incubated for 24 hours at 37ºC. Medium without disks was also incubated and diluted as above to serve as the control. L929 mouse fibroblasts (1 x 104 cell/ml) were cultivated in Eagle's medium supplemented with antibiotics and fetal bovine serum in 96 well culture plates and incubated for 24 hours at 37ºC in an air atmosphere containing 5% CO2. After 24 hours of incubation, the culture medium was replaced by 50 ml of eluate and 50 ml of fresh medium were added to each well of the 96-well culture plate and incubated for more... (Complete abstract, click electronic address below)
135

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental

Almeida, Carolina Souza [UNESP] 09 February 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-09. Added 1 bitstream(s) on 2015-09-17T15:49:21Z : No. of bitstreams: 1 000843397.pdf: 1823033 bytes, checksum: c39021817bdac57624d83d1107f2cb19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh
136

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial

Haddad, Marcela Filié [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:07Z : No. of bitstreams: 1 000764939.pdf: 4285251 bytes, checksum: 9da5ef190038848837a8d33e81f903b8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / FAPESP: 10/02937-1
137

Caracterização de resinas para base de prótese e reembasamento : propriedades físico-químicas e mecânicas /

Lombardo, Carlos Eduardo Leão. January 2013 (has links)
Orientador: Carlos Eduardo Vergani / Co-orientador: José Maurício dos Santos Nunes Reis / Banca: João Neudenir Arioli Filho / Banca: Janaína Habib Jorge / Banca: Rafael Leonardo Xediek Consani / Banca: Cláudia Helena Lovato da Silva / Resumo: Este estudo avaliou propriedades físico-químicas e mecânicas de resinas para base de prótese, uma fotoativada (Eclipse - E) à base de UDMA e outra termicamente ativada por micro-ondas (Nature Cryl MC - NC) à base de PMMA, e um reembasador quimicamente ativado (Tokuyama Rebase Fast II - TR II) à base de PEMA. Propriedades viscoelásticas (E', tan δ e Tg), contração linear de polimerização (CLP), sorção (Sor) e solubilidade (Sol) em água e em saliva artificial, grau de conversão (GC) e coeficiente de inchamento (CI) foram avaliados para a caracterização dos polímeros. A resistência à flexão dos materiais intactos (E, NC, TR II) e reembasados (E-E, E-TRII, NC-NC- NC-TR II) também foi avaliada. As propriedades viscoelásticas foram avaliadas em corpos-de-prova retangulares (64 x 10 x 3,3 mm), submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em dois ciclos de varredura após confecção (controle) e armazenagem em saliva. O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37 ºC e a temperatura de transição vítrea (Tg) foram registrados durante o 1º ciclo da DMTA. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). O coeficiente de inchamento foi realizado (n=5) de acordo com a teoria de Flory-Rhener. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Os dados foram avaliados por ANOVA, seguida por Tukey HSD (α=0,05) ou Dunnett (α=0,05). As resinas E e NC apresentaram similar E', superior a TR II... / Abstract: This study evaluated the physical-chemical and mechanical properties of denture base resins, one UDMA light-activated (Eclipse-E) and one PMMA heat-polymerized (Nature Cryl MC - NC). The PEMA autopolymerizing reliner (Tokuyama Rebase Fast II - TR II) was also evaluated. Viscoelastic properties (E', tan δ e Tg), linear shrinkage polymerization (LPS), sorption (Sor) and solubility (Sol) in water and in artificial saliva, degree of conversion (DC) and coefficient of swelling (CS) were employed for polymer characterization. The flexural strength of intact (E, NC, TR II) and relined samples (E-E, E-TRII, NC-NC- NC-TR II) was also made. The viscoelastic properties were evaluated by two cycles of dynamic mechanical thermal analysis (DMTA) on each rectangular (64 x 10 x 3.3 mm) samples (n=2). The storage modulus (E') and loss tangent (tan δ) at 37 ºC and the glass transition temperature (Tg) were recorded from the 1st DMTA cycle. LPS (%) was evaluated (n=10) by a Nikon 6C optical comparator, on circular samples (50 x 0.5 mm). Sor and Sol (μg/mm3) were measured (n=6) according to ISO 1567. DC (%) was evaluated (n=5) by FTIR spectroscopy (32 scans; resolution 4.0 cm-1). CS was evaluated (n=5) by Flory-Rhener theory. A three-point flexural tests (0.5 mm/min) was applied (n=10) on rectangular intact and relined samples. The ultimate flexural strength (FSU) and the flexural strength at the proportional limit (FSPl) were recorded in MPa. Data were analyzed with ANOVA, followed by Tukey HSD (α=0.05) ou Dunnett (α=0.05). E and NC had similar E', higher than TR II. Tan δ was arranged as TR II > NC > E. The Tg was not affected after saliva storage. The higher Tg values were obtained for E and NC. Tan δ peaks were shifted after 2 DMTA cycles. Regardless the medium immersion, Sor (μg/mm3) was arranged as NC > E > TR II. Saliva storage reduced Sol (μg/mm3) of the materials. E showed the lowest values of LPS, CS and... / Doutor
138

Influência do processamento de próteses totais maxilares com diferentes espessuras da base : análise gráfica da movimentação dos dentes artificiais /

Mazaro, José Vitor Quinelli. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Milton Carlos Gonçalves Salvador / Banca: Humberto Gennari Filho / Banca: Eduardo Piza Pellizzer / Resumo: A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA – á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below). / Mestre
139

Síntese, caracterização e efeito microbiológico de nanopartículas de sílica revestidas por prata quando associadas a resina acrílica quimicamente ativada, reembasador macio e ao glaze / Synthesis, characterization and microbiological effect of silver-coated silica nanoparticles when associated with chemically activated acrylic resin, soft reliner and glaze

Lucatto, Bruna Corrêa 06 December 2017 (has links)
Submitted by Bruna Corrêa Lucatto null (brulucatto@hotmail.com) on 2018-01-25T00:26:13Z No. of bitstreams: 1 merged (2).pdf: 2609941 bytes, checksum: 81898d81b1fe7413008b3e7b4b083151 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-02-01T19:05:03Z (GMT) No. of bitstreams: 1 merged (2).pdf: 2609941 bytes, checksum: 81898d81b1fe7413008b3e7b4b083151 (MD5) / Made available in DSpace on 2018-02-01T19:05:03Z (GMT). No. of bitstreams: 1 merged (2).pdf: 2609941 bytes, checksum: 81898d81b1fe7413008b3e7b4b083151 (MD5) Previous issue date: 2017-12-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi sintetizar e caracterizar nanopartículas de sílica recobertas por prata, e avaliar a influência quando incorporadas à resina acrílica quimicamente ativada, ao reembasador macio, e a um glaze, em suas características microbiológicas, microestruturais e mecânicas. Foi confeccionada, pelo método de hidrólise e condensação controlada (método de Stober), uma solução contendo nanopartículas de sílica revestidas por nanopartículas de prata em duas proporções, 10 milimols e 30 milimols, onde as mesmas foram caracterizadas. As nanopartículas de sílica incorporadas com a prata foram analisadas por energia dispersiva de raios-X integrado (EDS), microscopia eletrônica de varredura (MEV), e espalhamento de luz dinâmico (DLS). Para análise microbiológica foram confeccionadas 10 amostras cilíndricas (2mmx10mm), em resina acrílica quimicamente ativada onde as partículas foram incorporadas em duas concentrações: 2.5% e 5% com as duas molaridades diferentes 10 mM e 30 mM. Em outra situação foram confeccionadas 10 amostras cilíndricas (2mmx10mm) de reembasador macio, com concentrações de 2,5% e 5% com as duas molaridades diferentes 10 mM e 30 mM, no terceiro caso as partículas foram acrescentadas a um glaze nas duas concentrações e molaridades e aplicada sob uma amostra de reembasador macio. Uma suspensão de Candida albicans e Estreptococos mutans foi utilizada para análise de concentração inibitória mínima. Amostras retangulares em resina acrílica (n=6) de 30x10x3mm, foram confeccionadas para realização do teste de resistência a flexão de três pontos de ensaios mecânicos EMIC (Modelo DL-1000, EMIC Equipamentos e Sistemas LTDA., São José dos Pinhais - PR – Brasil), com velocidade de 1mm/min. Amostras sem a presença de nanopartículas foram confeccionadas como grupo controle. A sílica inicialmente apresentava-se como um pó de coloração branca e fina, após a sua caracterização com as partículas de Nitrato de Prata, houve alteração da coloração para um tom amarelado, aumento da sua densidade e do tamanho de suas nanopartículas. Os resultados de ação antimicrobiana foram positivos para as amostras de reembasador macio e glaze com 5% e 30 mMol de nanopartículas, já no ensaio mecânico não houve diferença significante estatisticamente entre os grupos. / The aim of this work was to synthesize and characterize silver - coated silica nanoparticles, and to evaluate the influence when incorporated into chemically activated acrylic resin, soft reliner, and glaze, in their microbiological, microstructural and mechanical characteristics. A solution containing silica nanoparticles coated by silver nanoparticles in two proportions, 10 millimols and 30 millimols, where they were characterized, was prepared by the hydrolysis and controlled condensation method (Stober method). Silica nanoparticles incorporated with silver were analyzed by integrated X-ray dispersive energy (EDS), scanning electron microscopy (SEM), and dynamic light scattering (DLS).For the microbiological analysis, 10 cylindrical samples (2mmx10mm) were made in chemically activated acrylic resin where the particles were incorporated in two concentrations: 2.5% and 5% with two different molarities of 10 mM and 30 mM. In another situation, 10 cylindrical samples (2mmx10mm) of soft reliner were made, with concentrations of 2.5% and 5% with the two different molarities 10 mM and 30 mM, in the third case the particles were added to a glaze in the two concentrations and molarities and applied under a sample of soft reliner. A suspension of Candida albicans and Streptococcus mutans was used for analysis of minimal inhibitory concentration. The samples were made in acrylic resin (n = 6) of 30x10x3mm and were made to perform the three-point flexural strength test of EMIC (Model DL-1000, EMIC Equipamentos e Sistemas Ltda., São José dos Pinhais - PR - Brazil), with a speed of 1mm / min. Samples without the presence of nanoparticles were made as a control group. The silica initially presented as a fine white powder after its characterization with the Silver Nitrate particles, there was a change of coloration to a yellowish tone, increase of its density and the size of its nanoparticles. The results of antimicrobial action were positive for the soft reliner and glaze samples with 5% and 30 mMol of nanoparticles, whereas in the mechanical assay there was no statistically significant difference between the groups.
140

Desenvolvimento de tintas em pó ignífugas à base de resina acrílica com adição das argilas montmorilonita e mica moscovita

Catarina, Gilmar Antonio Santa 04 August 2015 (has links)
As tintas em pó estão ganhando espaço no mercado, por serem ecologicamente corretas, sem solventes e com componentes sólidos. A proteção é uma de suas principais funcionalidades para evitar a ação direta de agentes agressivos. Por serem compostas de polímeros elas correm o risco em situações adversas de entrarem em combustão. O presente estudo sobre retardadores de chama tem a finalidade de avaliar a utilização de uma resina acrílica com a adição de argilas Montmorilonita (MMT) na classificação 15A , 30B, e Mica moscovita. A adição das argilas foi na proporção de 2% e 4%(m/m) e a incorporação das argilas na tinta em pó ocorreu no estado fundido através da extrusão. A mistura da tinta em pó base acrílica(TA) com as argilas ,antes da cura, foram analisadas por diferentes técnicas de caracterização, tais como, análise termogravimétrica (TGA), microscopia eletrônica de varredura (MEV), difração de raios X (DRX) e espectroscopia de infravermelho por transformada de Fourier (FTIR). A aplicação das tintas em pó sobre painéis de aço carbono AISI 1006 ocorreu por pulverização eletrostática. O efeito da incorporação de diferentes teores de argila nas propriedades físicas, proteção à corrosão e à combustão das tintas foram avaliadas por ensaios de medida de brilho, flexibilidade, resistência ao impacto, aderência, exposição à névoa salina e a chama (norma DIN 4102 B2). As tintas em pó com MMT e Mica moscovita apresentaram um comportamento térmico semelhante a amostra de tinta acrílica pura, sendo a perda de massa das amostras acima de 300ºC relacionadas à degradação da matriz polimérica. Pelo MEV constatou-se que as argilas MMT-15A e MMT- 30B apresentaram aglomerados irregulares e a Mica moscovita apresentou uma morfologia constituída por conjunto de placas paralelas sobrepostas. Através do DRX, a resina acrílica com argilas MMT-15A ou MMT-30B demonstraram o aparecimento de picos, sugerindo uma estrutura intercalada. A difração de raios-X da tinta acrílica com Mica moscovita 2% e 4% demonstraram perfil característico da argila, com picos agudos. Quanto as propriedades de retardamento de chama nos tempos de combustão de 60s e principalmente de 40s nas tintas acrílicas com Mica moscovita 2% e 4% apresentaram maior estabilidade térmica perante as demais formulações. O ensaio de flexibilidade mostrou que as amostras sem argila e com a Mica moscovita em 2% e 4% não apresentaram desplacamento. O ensaio de resistência ao impacto mostrou uma excelente resposta da resina acrílica pura. No teste de aderência constatou-se a inexistência de áreas desplacadas. O teste de dureza a lápis o filme mais resistente para o sistema foi da tinta acrílica MMT-30B em 4%. Nos ensaios de névoa salina todas as amostras apresentaram produtos de corrosão próximo à incisão. A tinta acrílica com Mica moscovita demonstrou inúmeras qualidades, principalmente o retardamento de chama. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2015-12-08T13:16:26Z No. of bitstreams: 1 Dissertacao Gilmar Antonio Santa Catarina.pdf: 401910 bytes, checksum: d9ce54a7c1f445abe5dd7919193f11df (MD5) / Made available in DSpace on 2015-12-08T13:16:26Z (GMT). No. of bitstreams: 1 Dissertacao Gilmar Antonio Santa Catarina.pdf: 401910 bytes, checksum: d9ce54a7c1f445abe5dd7919193f11df (MD5) / The powder coatings are gaining market share because they are environmentally friendly, solvent-free and solid components. Protection is one of its main features to avoid direct action of aggressive agents. Because they are composed of polymers they risk in adverse situations come into combustion. This study of flame retardants is intended to evaluate the use of an acrylic resin with the addition of Montmorillonite clays (MMT) in rank 15A, 30B, and muscovite mica. The addition of clay has a proportion of 2% and 4% (m / m) and the incorporation of clays in powder paint was in the molten state by extrusion. The mixture ink in acrylic-based powder (TA) with the clay, prior to curing, analyzed by various characterization techniques such as Thermogravimetric Analysis (TGA), scanning electron microscopy (SEM), X-ray diffraction (XRD ) spectroscopy and Fourier transform infrared (FTIR). The application of powder coatings on carbon AISI 1006 steel panels by electrostatic spraying occurred. The effect of incorporating different clay in physical properties, corrosion protection and combustion of the inks were evaluated by brightness measurement tests, flexibility, impact resistance, adhesion, exposure to salt spray and flame (DIN 4102 B2 ). Powder paints with MMT and Mica Muscovite had a similar thermal behavior pure acrylic paint sample, and the mass loss of the samples above 300 °C related to the degradation of the polymeric matrix. By SEM it was found that the MMT-clay and MMT 15A-30B show irregular agglomerates and Muscovite mica showed a morphology constituted by overlapping set of parallel plates. By XRD, acrylic resin MMT-clay or MMT 15A-30B show the appearance of peaks, suggesting an interleaved structure. The X-ray diffraction of acrylic paint with Muscovite Mica 2% and 4% clay showed a characteristic profile with sharp peaks. As the flame retardant properties in combustion times of 60 s and 40 s mainly in acrylic inks Muscovite Mica 2% and 4% had greater thermal stability towards other formulations. The flexibility test showed that the samples without clay and with the Muscovite Mica 2% and 4% showed no peeling. The impact resistance test showed an excellent response of pure acrylic resin. In the adhesion test it was found that no desplacadas areas. The pencil hardness test the tougher the film to the acrylic paint system was MMT-30B in 4%. In the salt spray test all samples showed corrosion products close to the incision. Acrylic paint with Muscovite Mica demonstrated many qualities, especially flame retardancy.

Page generated in 0.0599 seconds