• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 51
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 211
  • 211
  • 146
  • 104
  • 64
  • 63
  • 57
  • 42
  • 41
  • 26
  • 25
  • 25
  • 25
  • 24
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares /

Andreotti, Agda Marobo. January 2014 (has links)
Orientador: Daniela Micheline dos Santos / Banca: Marcelo Coelho Goiato / Banca: Simone Cecílio Hallak Regalo / Resumo: Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / Abstract: A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control - without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / Mestre
82

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores /

Shibayama, Ricardo. January 2002 (has links)
Orientador: Humberto Gennari Filho / Banca: Wirley Gonçalves Assunção / Banca: Marcelo Ferraz Mesquita / Resumo: Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / Abstract: This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four. / Mestre
83

Efeito da irradiação por microondas sobre a resistência à flexão e dureza de resinas acrílicas para reembasamento imediato /

Ribeiro, Daniela Garcia. January 2004 (has links)
Orientador: Ana Cláudia Pavarina / Banca: Eunice Teresinha Giampaolo / Banca: Ricardo Faria Ribeiro / Resumo: O uso do microondas tem sido indicado como um método efetivo na desinfecção de resinas acrílicas. Entretanto, há pouca informação sobre o efeito da irradiação do microondas nas propriedades mecânicas desses materiais. Considerando esses aspectos, o objetivo deste estudo foi avaliar o efeito da irradiação por microondas sobre as propriedades mecânicas de resistência à flexão e dureza de resinas acrílicas. Os corpos-de-prova para a realização dos testes mecânicos foram confeccionados com os seguintes materiais: Kooliner (K), Tokuso Rebase Fast (TR), Ufi Gel Hard C (UGH) e New Truliner (NT), todas resinas indicadas para reembasamento imediato, e Lucitone 550 (L), que é uma resina para base de prótese. Para cada material foram confeccionados 48 corpos-de-prova que foram divididos igualmente em seis grupos. As resinas autopolimerizáveis (K, TR, UGH e NT) foram submetidas à irradiação logo após a confecção, enquanto que os corpos-de-prova da resina termopolimerizável (L) permaneciam 50 l 2 horas em água a 37ºC l 1ºC antes da irradiação. Para o procedimento de irradiação, cada corpo-de-prova foi individualmente imerso em 200 mL de água destilada e submetido a dois ciclos de irradiação pelas microondas, para simular o envio da prótese ao laboratório e o retorno dela ao consultório odontológico. Cada corpo-de-prova foi irradiado a uma potência constante de 650 W, variando-se o tempo de exposição: 1 minuto (T1), 2 minutos (T2), 3 minutos (T3), 4 minutos (T4) ou 5 minutos (T5). O grupo controle (T0) foi submetido aos testes mecânicos sem ser irradiado pelas microondas. Os ensaios de resistência à flexão para todos os corpos-de-prova foram realizados em máquina MTS-810 Material Test System sob velocidade de 5 mm/minuto, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do ...(Resumo completo, clicar acesso eletônico abaixo) / Abstract: Microwave irradiation was previous suggested as an effective method for the disinfection of acrylic resins. However, little information is available concerning the effect of microwave irradiation on the mechanical properties of acrylic resins. The purpose of this study was to evaluate the effect of two cycles of a microwave disinfection procedure on the flexural strength and Vickers hardness of acrylic resins. Four autopolymerized resins (Kooliner- K, Tokuso Rebase Fast- TR, Ufi Gel Hard- UGH and New Truliner- NT) and one heat-cured resin (Lucitone 550- L) were used for preparing specimens. For each material, 48 specimens were made and equally divided into six groups. The relined specimens were submitted to disinfection procedures after polymerization and the denture base polymer specimens were stored in water for 50 l 2 hours at 37ºC l 1ºC prior to disinfection. The specimens were individually immersed in 200 mL of destilated water and microwaved twice, simulating when dentures come from the patient and before being returned to the patient. Each cycle of microwave disinfection was performed at 650 W for one of the following irradiation times: 1 minute (T1), 2 minutes (T2), 3 minutes (T3), 4 minutes (T4) or 5 minutes (T5). Control group (T0) specimens were subjected to mechanical tests without being disinfected. The flexural strength values of the materials were determined using a testing machine MTS-810 at a crosshead speed of 5 mm/minute using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load, after 30 seconds contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. The flexural and hardness values were submitted to ANOVA and ...(Complete abstract, click electronic access below) / Mestre
84

Efetividade de vernizes fotopolimerizáveis experimentais na redução da hidrofobicidade e adesão de Candida albicans em uma resina para base de prótese /

Lazarin, Andréa Azevedo. January 2009 (has links)
Resumo: Foi proposto avaliar diferentes vernizes experimentais, que apresentam em sua formulação monômeros hidrofílicos ou zwiteriônicos, como método para modificar a superfície de resina acrílica para base de prótese, com o objetivo de prevenir a adesão de C. albicans. Foram confeccionados corpos-de-prova com características superficiais que simulavam a parte polida das próteses (superfície lisa) e com características superficiais que simulavam a parte interna das próteses (superfície rugosa) utilizando-se uma resina para base de prótese específica para micro-ondas (Vipi Wave). Matrizes metálicas com 10 cavidades (13,8 mm de diâmetro e 2 mm de altura) foram incluídas em mufla, entre 2 placas de vidro, para simular a superfície lisa, ou em contato com gesso para obter amostras que simulassem a superfície rugosa da prótese. Todos os corpos-de-prova foram submetidos à mensuração da rugosidade utilizando-se um rugosímetro (Mitutoyo SJ 400) com cutoff de 2,5 mm. A rugosidade superficial foi determinada (Ra-µm) pela média de três mensurações realizadas em cada amostra. Após a leitura da rugosidade, os corpos-de-prova foram divididos em grupo controle (n=72; 36 lisos e 36 rugosos), não recebendo nenhum tratamento superficial, e 12 grupos experimentais (n=72; 36 lisos e 36 rugosos) que receberam uma camada do verniz experimental sendo polimerizado em forno EDG. Os vernizes experimentais apresentaram em sua composição o monômero metil metacrilato (MMA), dois agentes de ligação cruzada (TEGDMA e Bis-GMA) e o foto iniciador MBP (4- metil benzofenona). Além desses componentes, os vernizes identificados pelos códigos P, E e T apresentaram monômeros hidrofílicos em 3 concentrações (25, 30 e 35%). O verniz identificado pelo código M apresentou um monômero zwiteriônico (MZ), nas mesmas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the use of different experimental varnishes containing zwitterion or hydrophilic monomers as a manner to modify the surface characteristics of a denture base resin and prevent the adhesion of C. albicans. For such purpose, specimens with surface characteristics that simulated the polished side of the dentures and the inner side of the dentures were fabricated using a microwave-polymerized denture base acrylic resin (Vipi Wave). Hollow metallic matrices with 10 cavities (13.8 mm diameter x 2 mm high) were flasked either between two glass plates, in order to produce specimens with smooth surfaces that simulated the polished side of the dentures, or in direct contact with the stone, in order to obtain specimens with rough surfaces that simulated the inner side of the dentures. All specimens were subjected to surface roughness readings in a roughness meter (Mitutoyo SJ 400) with cutoff length of 2.5 mm. Surface roughness (Ra, µm) was determined as the average of three random measurements made on each specimen. After the roughness readings, the specimens were randomly assigned to one control group (n=72; 36 smooth and 36 rough specimens), in which the specimens received no surface treatment, and 12 experimental groups (n=72; 36 smooth and 36 rough specimens) in which the specimens were coated with one of the experimental varnishes followed by polymerization in an EDG oven. The 12 experimental varnishes presented in their composition the monomer methyl methacrylate (MMA), two crosslinking agents (TEGDMA and Bis-GMA) and a photoinitiator agent (4-methyl benzophenone . MPB). In addition to these components, the experimental varnishes labeled as P, E and T presented hydrophilic monomers at three concentrations (25, 30 and 35%). The experimental varnish labeled as M presented a zwitterion... (Complete abstract click electronic access below) / Orientador: Ana Lucia Machado / Coorientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Marco Antonio Compagnoni / Banca: Dalva Cruz Laganá / Banca: Cláudia Helena Lovato da Silva / Doutor
85

Efeitos da terapia fotodinÃmica mediada por um novo dispositivo de luz comparada a compostos quÃmicos indicados para descontaminaÃÃo da resina acrÃlica / Effects of photodynamic therapy mediated by a new light device compared to chemical compounds indicated for descontamination of acrylic resins

Janaina CÃncio de Holanda Prado 08 July 2015 (has links)
A desinfecÃÃo ou esterilizaÃÃo de dispositivos de resina acrÃlica, como prÃteses imediatas, guias e goteiras cirÃrgicas, à importante na prevenÃÃo da contaminaÃÃo do paciente por micro-organismos potencialmente patogÃnicos. As resinas acrÃlicas sÃo materiais termossensÃveis, podendo somente ser descontaminadas por meios quÃmicos ou frios. Esta dissertaÃÃo teve como objetivos fazer uma revisÃo de literatura sistemÃtica sobre a aÃÃo antimicrobiana de agentes quÃmicos em resinas acrÃlicas, alÃm de realizar um estudo experimental avaliando o efeito da terapia fotodinÃmica, mediada pelo fotossensibilizador azul de metileno a 22 &#956;M, sobre o nÃvel de contaminaÃÃo por micro-organismos presentes em prÃteses totais advindas de diferentes laboratÃrios protÃticos, bem como um novo equipamento composto por diodos emissores de luz (LEDs) de 630 nm e 1W. Para a revisÃo de literatura foram utilizados os descritores ÂÂmicroorganismsÂÂ, ÂÂdental prosthesisÂÂ, e/ou ÂÂdisinfection nas bases de dados Pubmed/ Bireme, com busca no perÃodo de 2004 a 2014, incluindo artigos em inglÃs referentes a pesquisas experimentais, comparando-se agentes quÃmicos sobre mais de uma espÃcie de micro-organismo, na superfÃcie de resinas acrÃlicas. Foi verificado que os mÃtodos apresentaram variaÃÃes nos efeitos antimicrobianos, dependendo do tempo de imersÃo, concentraÃÃo do produto e a espÃcie de micro-organismo presente. O hipoclorito de sÃdio 1%, o digluconato de clorexidina 2% e o Ãcido acÃtico apresentaram maior eficÃcia, em ordem decrescente. No estudo experimental, foram selecionadas 25 prÃteses totais superiores precedendo a instalaÃÃo nos pacientes. Em seguida, as mesmas foram aleatoriamente distribuÃdas por sorteio em quatro grupos: sem tratamento; imersÃo em digluconato de clorexidina 2% por 10 minutos; apenas irradiaÃÃo com LEDs; terapia fotodinÃmica (TFD). O circuito de controle e acionamento do equipamento composto por 8 LEDs de 1W foi desenvolvido em parceria com o LaboratÃrio de Engenharia de Sistema de ComputaÃÃo, na Faculdade de Engenharia de TeleinformÃtica da Universidade Federal do CearÃ. No grupo TFD, a irradiaÃÃo por 1 minuto ocorreu depois de 5 minutos da aplicaÃÃo do fotossensibilizador. ApÃs os tratamentos realizados, as prÃteses foram imersas em 100 ml de BHI caldo e levadas à cuba ultrasÃnica por 15 minutos. Foram coletados 5 ml deste meio de cultura para incubaÃÃo por 48 horas a 37ÂC. Em seguida, 1000 microlitros do caldo foram diluÃdos em 1:10, 1:100, 1:1000 e plaqueados em triplicada, em Ãgar Sangue, Ãgar Sabouraud Dextrose, e Hicrome UTI ÃgarÂ. As placas foram incubadas a 37ÂC por 48 horas, para posterior contagem de unidades formadoras de colÃnia (UFC/ml) e classificaÃÃo dos dados em escala ordinal. Testes de Kruskall-Wallis, Dunn, ANOVA (2 critÃrios) e Bonferroni (&#945;=0,05) foram aplicados. A TFD mostrou reduÃÃo significativa na contagem de bactÃrias totais viÃveis (p=0,0002), quando comparada ao grupo somente irradiado, e reduÃÃo significativa de fungos totais viÃveis, quando comparada aos grupos sem tratamento e somente irradiado (p=0,0002). A TFD teve efeito antimicrobiano semelhante à imersÃo em digluconato de clorexidina 2% por 10 minutos (p>0,05). As espÃcies bacterianas identificadas mais prevalentes nas prÃteses foram P. aeruginosa, K. pneumoniae e E. coli e a TFD promoveu diminuiÃÃo significativa na contagem destas espÃcies, assim como a clorexidina (p<0,001). A contaminaÃÃo de prÃteses dentÃrias advindas de laboratÃrios protÃticos foi expressiva. A terapia fotodinÃmica empregada no protocolo proposto para dispositivos de resina acrÃlica mostrou efeito antimicrobiano promissor mediante esta contaminaÃÃo. / Disinfection or sterilization of acrylic resin devices, such as immediate prostheses, surgical guides and gutters, is important in preventing the patient from contamination by potentially pathogenic microorganisms. Acrylic resins are heat-sensitive materials, which can only be decontaminated by chemicals or cold means. This study aimed at making a systematic review of literature on the antimicrobial action of chemical agents on acrylic resins. In addition, it was carried out an experimental study evaluating the effect of photodynamic therapy, mediated by methylene blue photosensitizer to 22 &#956;M, on the level of contamination by microorganisms present in dentures coming from different laboratories, and a new device consisting of light emitting diodes (LEDs) 630 nm and 1W. For the literature review, we used the descriptors microorganisms, dental prosthesis, and/or disinfection in Pubmed/ Bireme databases with search from 2004 to 2014, including articles in English on experimental studies comparing chemical agents on more than one species of microorganism in the surface of acrylic resin. It was found that methods show differences in antimicrobial effects depending on the immersion time, product concentration and type of present microorganism. Sodium hypochlorite 1%, chlorhexidine digluconate 2% and acetic acid showed greater efficacy, in decreasing order. In the experimental study, a number of 25 upper dentures were selected and installed in patients. Then, the dentures were randomly distributed into four groups: untreated; immersion in 2% chlorhexidine digluconate for 10 minutes; only irradiation with LEDs; photodynamic therapy (PDT). The control circuit and activation of equipment consisting of 8 LEDs 1W was developed in partnership with the Computer System Engineering Laboratory at the Faculty of Computer Engineering at the Federal University of CearÃ. On the PDT group, irradiation for 1 minute took place 5 minutes after application of the photosensitizer. After the treatment, the prostheses were immersed in 100 ml of BHI broth and then brought to ultrasonic tank for 15 minutes. It was collected 5 ml of this culture for incubation for 48 hours at 37  C. After that, 1000 microliter of the broth were diluted 1:10, 1: 100, 1: 1000 and plated in triplicate, on Blood Agar, Sabouraud Dextrose Agar and HiCrome UTI ÃgarÂ. The plates were incubated at 37ÂC for 48 h and then counting colony forming units (CFU / ml) and classification of data on an ordinal scale. Kruskal-Wallis test, Dunn, ANOVA (2 criteria) and Bonferroni (&#945; = 0.05) were applied. PDT showed significant reduction in count of total viable bacteria (p = 0.0002) compared to only irradiated group, and a significant reduction of total viable fungi, when compared to the only irradiated groups and untreated (p = 0.0002). PDT showed antimicrobial effect similar to immersion in 2% chlorhexidine digluconate for 10 minutes (p> 0.05). The most prevalent bacterial species identified in the prostheses were P. aeruginosa, K. pneumoniae and E. coli and PDT caused a significant decrease in counting of these species as well as chlorhexidine did (p <0.001). The contamination of dental prostheses coming from prosthetic laboratories was significant. Photodynamic therapy used in the proposed protocol for acrylic resin devices showed promising antimicrobial effect by this contamination.
86

Resistencia ao impacto e morfologia de fratura de resinas acrilicas processadas por energia de microondas e banho de agua quente / Impact strenght and fracture morphology of heat and microwaves polymerized acrylic resins

Costa, Marcelo de Almeida 30 August 2005 (has links)
Orientador: Renata Cunha Matheus Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T11:29:35Z (GMT). No. of bitstreams: 1 Costa_MarcelodeAlmeida_M.pdf: 3239895 bytes, checksum: cf5932b7fd5f5024e8d16d48a3f2b663 (MD5) Previous issue date: 2005 / Resumo: Foi objetivo deste trabalho avaliar a resistência ao impacto e morfologia de fratura de resinas acrílicas processadas por microondas e banho de água quente. Foram confeccionados 20 corpos-de-prova por grupo medindo 65x10x2,5mm para as resinas: Lucitone 550 (74oC/9 horas); Onda Cryl (3 minutos/360W, 4 minutos/pausa, 3 minutos/810W); Acron MC (3 minutos/500W) e Vipi Wave (20 minutos/180W, 5 minutos/540W). A resistência ao impacto foi avaliada em máquina Otto Wolpert Werke pelo método Charpy, com energia de carga de 40 Kp.cm (3,9466J), e as fraturas classificadas em frágeis ou intermediárias. A fractografia foi realizada por análise dos ângulos de propagação das fendas, e a caracterização morfológica microestrutural por observação em microscopia eletrônica de varredura (MEV). Os resultados de resistência ao impacto foram submetidos ao teste de Tukey e para comparação dos ângulos A e B dos fragmentos fraturados, foi aplicado o teste de Kruskal-Wallis e Coeficiente de Pearson. Foram observadas diferenças (p<0,01) para a resistência ao impacto, sendo que a resina Vipi Wave apresentou o menor valor. A maioria das fraturas foi classificada como frágil (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). A análise angular das fraturas frágeis não evidenciou diferenças, entretanto para fraturas intermediárias a resina Onda Cryl diferiu (p<0,01) das demais. A MEV evidenciou que fraturas frágeis apresentam planos cristalográficos definidos e organizados, enquanto que as intermediárias apresentam grau de desorganização. Conclui-se que resinas de microondas apresentam resistência ao impacto semelhante às de banho de água quente, e independente do processamento, as resinas apresentaram maior número de fraturas frágeis / Abstract: The aim of this study was to evaluate to the impact to resistance and morphology of processed acrylic resin breaking for microwaves and hot water bath. 65x10x2,5mm for resins had been confectioned 20 samples measuring: Lucitone 550 (74ºC/9 hours); Cryl wave (3 minutes/360W, 4 minutes/brake, 3 minutes/810W); Acron MC (3 minutes/500W) and Vipi Wave (20 minutes/180W, 5 minutes/540W). The impact to resistance was evaluated in machine Otto Wolpert Werke for the Charpy method, with load of 40 Kp.cm (3,9466J), and breakings classified in the fragile or intermediate. The fractography was carried through by analysis of the angles of propagation of the cracks, and the microstructural morphologic characterization for comment in electronic microscopy of sweepings (MEV). The results of impact to resistance had been submitted to the test of Tukey and for comparison of the angles the test of Kruskal-Wallis and coefficient of Pearson was applied. Differences (p<0,01) had been observed for the impact to, being that the resin Vipi Wave presented the lesser value. The majority of the breakings were classified as fragile (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). The angular analysis of the fragile breakings did not evidence differences, however for intermediate breakings the resin Onda Cryl differed (p<0,05) of excessively. The MEV evidenced that fragile breakings present definite and organized cristalgraphic plans, while that the intermediate present disorganization degree. One concludes that resins of microwaves present resistance to the similar impact to the ones of hot water bath, and independent of the processing, the resins had presented greater number of fragile breakings / Mestrado / Protese Dental / Mestre em Clínica Odontológica
87

Resistencia ao impacto da união dente-resina acrilica sob efeito da desinfecção simulada por energia de microondas / Effect of simulated microwave disinfection on bond strength of acry teeth and denture base resins

Cardoso, Leandro 13 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:07:44Z (GMT). No. of bitstreams: 1 Cardoso_Leandro_M.pdf: 718836 bytes, checksum: 03cc173acd1c7745a9df4dd35a8a70dc (MD5) Previous issue date: 2009 / Resumo: O objetivo deste trabalho foi verificar a resistência ao impacto da união denteresina acrílica, sob efeito da desinfecção simulada por energia de microondas. Cento e sessenta matrizes retangulares de cera utilidade (30x15x5mm) foram incluídas na parte inferior de muflas, com gesso pedra tipo III. Depois da cristalização do gesso, a cera foi removida e cada um dos 160 moldes de gesso resultante foi preenchido com silicone laboratorial. Sobre o silicone foi adaptado um dente molar de resina acrílica contendo um cilindro de cera (25mm de comprimento por 6mm de diâmetro) fixado na base. O conjunto foi revestido com silicone, a mufla preenchida com gesso pedra tipo III e levada à prensa de bancada por 1 hora. Em seguida, a mufla foi aberta e os conjuntos dente-cilindros removidos dos moldes. Os dentes foram escovados com solução de água quente e detergente líquido e adaptados nos moldes, com as bases submetidas previamente aos seguintes tratamentos: 1- sem tratamento, 2- desgaste com broca, 3- retenção com broca e 4- condicionamento com monômero. Oitenta cilindros de resina unidos à base dos dentes foram confeccionados com resina acrílica Clássico, em ciclo de água à temperatura de 74ºC por 9 horas, em termopolimerizadora automática (Termotron) e outros 80 com resina para microondas Onda-Cryl, em forno doméstico com 900W de potência: fase 1- três minutos com 40% da potência; fase 2- quatro minutos com 0% da potência; e fase 3- três minutos com 90% da potência. Os corpos-de-prova foram desincluídos após esfriamento das muflas em bancada. Metade dos corpos-de-prova de cada resina foi submetido à desinfecção simulada por microondas, em forno doméstico a 650W por 3 minutos, imersos individualmente em 150mL de água. Os demais corpos-de-prova não foram desinfectados (controle). Após armazenagem em água à temperatura de 37ºC por 24 horas, os corpos-de-prova foram submetidos ao teste de resistência ao impacto da união dente-resina, numa máquina Otto Wolpert Werke (sistema Charpy) com 40 kpcm de impacto. Os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey para comparação das médias, em nível de 5% de significância. Os diferentes tratamentos na base dos dentes promoveram diferentes efeitos sobre a resistência da união dente-resina, em ambas as condições de desinfeção por microondas / Abstract: The aim of this study was to evaluate the effect of microwave disinfection in bond strength of acrylic teeth and a denture base resin. A hundred sixty rectangular wax patterns (30x15x5mm) were embedded in flasks with type III dental stone. After cristalization, the resulting moulds were filled with laboratorial silicone (Zetalabor), in which a molar acrylic tooth was included (36 Biotone IPN Vita) using a cylindrical wax (6x25mm) to join to the tooth base. The set was invested using laboratorial silicone and type III dental stone. After 1 hour, the flask was opened, the cylindrical wax removed from the tooth. Teeth were adapted in the moulds with the ridge laps submitted previously to the following treatments: 1 - no treatment; 2 -bur abrasion; 3 - bur grooving, and 4 - etched by monomer. Eighty rods of the Clássico acrylic resin atached to the tooth ridge lap were polymerized in bath cycle at 74ºC for 9 hours and deflasked after flask cooling, and 80 of Onda-Cryl acrylic resin were polymerized in 900W-domestic microwave oven following manufacturer's instructions. Specimens were deflasked after bench cooling. Fourty specimens of each acrylic resin were submitted to microwave disinfection, in a domestic oven at 650W for 3 minutes, individually immersed in 150mL of water. Other specimens were not disinfected (control). Specimens were stored in water at 37oC for 24 hours before impact test. Charpy impact strength test was performed using an impact testing machine (Otto Wolpert Werke) calibrated to 40 kpcm. Data were submitted to analysis of variance and Tukey's test at 5% of significance level. Different treatments on tooth ridge lap promoted different effects in the tooth-resin bond strength, in both conditions of simulated disinfection by microwave energy / Mestrado / Protese Dental / Mestre em Clínica Odontológica
88

Influencia de diferentes tipos de muflas na movimentação de dentes de proteses totais superiores / Influence of different flask types on teeth displacement in complete upper dentures

Santos, Mateus Bertolini Fernandes dos, 1985- 02 October 2010 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piraciaba / Made available in DSpace on 2018-08-15T04:23:57Z (GMT). No. of bitstreams: 1 Santos_MateusBertoliniFernandesdos_M.pdf: 2329758 bytes, checksum: 359af0abc873ef75f6b0cf7077d9a714 (MD5) Previous issue date: 2010 / Resumo: O objetivo neste estudo foi verificar a influência de diferentes tipos de muflas na movimentação de dentes ocorrida em próteses totais padronizadas após o processamento laboratorial em ciclo de polimerização longo (74±2°C por 9 horas), em banho de água. A partir de matrizes em silicone, foram obtidos 31 modelos em gesso pedra tipo III de uma arcada desdentada superior e 31 de uma inferior. Sobre um modelo superior foram confeccionada base de prova e plano de orientação em cera com dimensões de 20 mm de altura na região anterior e 10 mm na região posterior. Este plano foi montado em articulador semi-ajustável, e após isso foi confeccionada base de prova e plano de cera inferior seguido pela montagem do modelo inferior no articulador. Após a realização da montagem dos dentes artificiais nos planos de cera, foi confeccionada uma matriz em silicone laboratorial para possibilitar a reprodução da montagem dos dentes. Foram então encerados 30 pares de próteses totais, distribuídos aleatoriamente em três grupos (n=10): Mufla convencional, Mufla Dupla e Mufla HH com os dentes em oclusão. Antes da inclusão pinos referenciais foram colocados em locais padronizados e as distâncias entre incisivos (I-I), pré-molares (P-P), molares (M-M), incisivo a molar do lado esquerdo (IE-ME) e incisivo a molar do lado direito (ID-MD) aferidas em microscópio óptico linear com 0,0005 mm de precisão. Após a polimerização estas distâncias foram aferidas novamente, e os dados obtidos analisados estatisticamente através dos testes t-pareado, ANOVA e Holm-Sidak, todos com 95% de confiança. Foram encontradas diferenças estatisticamente significantes entre as distâncias P-P (p=0,003 para mufla dupla; e p<0,001 para mufla HH) e M-M (p=0,006 para mufla convencional; p=0,005 para mufla dupla; e p<0,001 para mufla HH). Quando comparadas entre si, foi encontrada diferença estatisticamente significante entre pré-molares (p=0,011) sendo que a mufla convencional apresentou menor diferença entre as distâncias pré/pós-polimerização que a mufla HH (p=0,003). Todas as muflas envolvidas neste estudo apresentaram diferenças estatisticamente significantes em ao menos uma das distâncias aferidas, sendo que a mufla convencional apresentou os melhores resultados / Abstract: The aim of this study was to verify the influence of different flask types in the teeth displacement after processing standardized complete dentures in long cycle of polymerization in water bath (9 hours at 74°C). Thirty-one superior and thirty-one inferior stone casts of an edentulous arch were poured with type III stone, from a silicone matrix. One superior cast was mounted in a semi-adjustable articulator with wax rim height of 20 mm in anterior region and 10 mm in the posterior, and then the inferior cast was mounted too. After teeth wax-up, silicone matrix were made with laboratory silicone to enable the reproduction of the same wax-up pattern. The dentures were assigned randomly in 3 groups (n=10): Traditional flask, Double Flask and HH flask with teeth in occlusion. Before flasking reference pins were placed in standardized places and the distances between incisive (I-I), pre-molars (P-P), molars (M-M), left incisor to left molar (LI-LM) and right incisor to right molar (RI-RM) were measured in an optical microscope with 0.0005 mm accuracy. After polymerization, these distances were re-measured and the data obtained was statistical analyzed trough paired t-test, ANOVA and Holm-Sidak, all with 95% of confidence level. It was found statistical differences among P-P (p=0.003 for double flask; and p<0.001 for HH flask) and M-M (p=0.006 for traditional flask; p=0.005 for double flask; and p<0.001 for HH flask). When compared, it was found statistical differences among pre-molars (p=0.011) where conventional flask showed minor differences than HH flask (p=0.003). All flask types used in this study presents statistical differences in at least one of the measured distances, being that traditional flask showed better results / Mestrado / Protese Dental / Mestre em Clínica Odontológica
89

Using eggshell for the development of a quality alternative material to pumice in reducing the surface roughness of heat-cured acrylic resins.

Onwubu, Stanley Chibuzor January 2016 (has links)
Submitted in fulfillment of requirements of the degree of Master in Health Sciences: Dental Technology, Durban University of Technology, Durban, South Africa, 2016. / Pumice is used in the polishing of dental appliances to remove surface irregularities. It is usually used in a slurry form that is pumice powder mixed with water. In Nigeria, the increased cost of pumice as a result of its limited supply into the country has encouraged dental technicians to re-use pumice slurry for longer periods than advocated when polishing acrylic dentures, whether new or old dentures which have been worn in the mouth. Consequently, this is likely to increase cross-infection of communicable diseases in the dental technology laboratory. Although materials such as white sand, black sand and porcelnite can be used, literature documents that these materials are less effective in the polishing of acrylic dentures (Areeg 2011). The focus of this study was to use eggshells, a natural waste product, to develop and test the quality of an alternative material to reduce the surface roughness of heat-cured acrylic resins. A quantitative research paradigm and an experimental research strategy were adopted. The research design included two phases. In phase one of this study, different characterisation techniques such as Brunnae-Emmer Teller (BET); Fourier Transform Infrared Spectroscopy (FTIR); X-ray Diffraction (XRD); Energy Dispersive X-ray Spectroscopy (EDX) and Scanning Electron Microscope (SEM); Transmission Electron Microscopy (TEM); Laser Scattering Particle Size Distribution Analyser (PSA); Thermo-Gravimetric Analysis (TGA); and Induction-Coupling-Optical Emission Spectroscopy (ICP-OES) were used to assess the suitability of the new abrasive material (NAM). In addition, the level of microbial contamination of the NAM was assessed in line with the specified microbial limits for cosmetic products. In contrast, phase two investigated the product-based quality of the NAM as an abrasive material for removable dental appliances. There were two sample groups, that is, the NAM (test group) and Pumice (control), and each sample group had 50 PMMA acrylic specimens. The surface roughness (Ra) was measured using a Talysurf profilometer. An Independent Tukey test was used to analyse the Ra values (p=0.05). A Scanning Electron Microscope (SEM) and Optical Microscope (OEM) were further used to support the results of the profilometer in terms of the quality of surface finish and polish. Validity of the study was achieved following the ISO 20795-1 (2013) methods of preparation and fabrication of the acrylic specimens. The reliability was determined via reproducibility and repeatability of tests. The BET analysis showed that the NAM is predominantly a mesoporous powder. The FTIR and XRD analyses confirmed that the NAM is pure calcite with unique water absorbing characteristics, and is free of bacteria. The EDX and ICP-OES analyses revealed calcium, oxygen and carbon as the major elemental composition of the NAM. The SEM and TEM images revealed irregular shaped particles in the NAM. The PSA analysis of the particle distribution showed the NAM to be superfine (50nm to 0.3µm) and medium (44µm powder), respectively. The TGA analysis revealed a high-grade carbonate product in the NAM (>66.0 mass% of calcium carbonates). In addition, and in terms of in the qualities of the NAM in reducing the surface roughness of PMMA resins, the test group and the control group produced Ra values that were significant different (p<0.0001). The SEM and OEM analyses further confirmed the differences in the surfaces between the polished sample groups at different magnifications. Overall, the control showed the highest mean average (0.1056±0.03688µm), whereas the test group had the lowest Ra values (0.0476±0.01379). The lowest Ra values measured with the test group indicated that the NAM improves the surface smoothness of PMMA acrylic specimens. Notably, this study conclusively showed that the NAM effectively reduces the surface roughness to below the threshold limit value of 0.2µm. Significantly, and in associating the Ra values to the threshold limit value of 0.2µm, the NAM produced better results than pumice. Hence the use of the NAM as a polishing material for acrylic dentures is highly recommended. Finally and in line the NAM being a suitable alternative to pumice as it effectively reduces the surface roughness of PMMA specimens, future investigation into the use of eggshell nanoparticles to develop dental prophylaxes will be encouraged. / M
90

Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibers

Colán Guzmán, Paola del Rosario 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.

Page generated in 0.0699 seconds