• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • Tagged with
  • 25
  • 25
  • 25
  • 22
  • 22
  • 13
  • 10
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas /

Reis, José Mauricio dos Santos Nunes. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Renata Cunha Matheus Rodrigues Garcia / Banca: Karin Hermana Neppelenbroek / Banca: João Neudenir Ariolli Filho / Banca: Eunice Teresinha Giampaolo / Resumo: Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below) / Doutor
22

Avaliação in vitro da citotoxicidade de resinas acrílicas para reembasamento baseadas em uma nova formulação /

Costa, Cristiane Campos. January 2009 (has links)
Resumo: O objetivo deste estudo foi determinar a citotoxicidade in vitro de duas resinas reembasadoras experimentais autopolimerizáveis contendo alta concentração de agentes de ligação cruzada, etilenoglicol dimetacrilato (EGDMA) e 1,4-butanodiol dimetacrilato (BDMA) comparadas com uma resina reembasadora comercial (Tokuyama Rebase Fast II). Foram confeccionados corpos-de-prova em forma de discos das três resinas acrílicas reembasadoras rígidas sob condições assépticas. Os fibroblastos (L929) foram cultivados em placas com 96 compartimentos e incubadas por 24 h em meio de cultura Eagle. Os extratos foram preparados, colocando-se três amostras de cada resina em frascos de vidro estéreis com 9 mL de meio de Eagle e incubadas a 37º C por 24 h. O efeito citotóxico dos extratos foram avaliados utilizando os testes de incorporação do 3H-timidina e MTT, que refletem os níveis de síntese de DNA e metabolismo celular, respectivamente. Os dados foram analisados estatisticamente, utilizando análise de variância (P<0.05). Para o teste de incorporação do 3H-timidina, não foram observadas diferenças significativas (P>0.05) entre os materiais. A média da quantidade do isótopo incorporado no DNA celular para todas as resinas acrílicas foi estatisticamente menor do que para o controle. Todas as resinas acrílicas foram classificadas pelo teste de incorporação do 3Htimidina como moderadamente citotóxicas. Da mesma forma, para o teste do MTT, não foi encontrada diferença significativa para a citotoxicidade entre os materiais (P>0.05). Quando a citotoxidade foi comparado com o grupo controle, todas as resinas foram classificadas entre não citotóxicas e discretamente citotóxicas pelo teste do MTT. Assim, conclui-se que a incorporação dos agentes de ligação cruzada, EGDMA e BDMA não influenciaram significativamente sobre a citotoxicidade observada. Não houve diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the cytotoxicity in vitro of two trials autopolymerizing reline systems made with higher concentration of cross-linking agents, EGDMA and BDMA compared to a commercial reline resin. Sample disks of the three hard reline acrylic resins were fabricated under aseptic conditions. The Fibroblast L929 cells were cultured in 96-well plates and incubated for 24 h in Eagle's medium. Eluates were prepared by placing three samples into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37ºC for 24 h. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. The data were statistically analyzed by using the one-way analysis of variance (P<.05). With the 3H-thymidine incorporation assay, no significant differences (P > .05) were found between the materials. The mean quantity of isotope incorporated into cellular DNA for all acrylic resins was statistically smaller than for the control. All acrylic resins were graded by the 3Hthymidine incorporation assay as moderate cytotoxic. Similarly, with the MTT assay, no significant difference in cytotoxicity was found between the materials (P > .05). When the cytotoxicity was compared with control group, all resins assay were between non cytotoxic and slight cytotoxic by the MTT. The incorporation of cross-linking agents, EGDMA and BDMA had no significant influence on the cytotoxicity observed. There was no cell viability difference between all materials in both assays. / Orientador: Eunice Teresinha Giampaolo / Coorientador: Iracilda Zeppone Carlos / Banca: Renata Cristina Silveira Rodrigues Ferracioli / Banca: Iracilda Zeppone Carlos / Mestre
23

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese /

Seó, Rosangela Seiko. January 2006 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Banca: Rodrigues Nunes Rached / Resumo: O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / Abstract: This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection. / Doutor
24

Efetividade da escovação com diferentes agentes de limpeza de próteses na redução da viabilidade de biofilme in vitro da candida albicans /

Pellizzaro, Delise. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Eunice Teresinha Giampaolo / Banca: Cláudia Helena Lovato da Silva / Resumo: A Candida albicans tem sido considerada o principal agente etiológico da estomatite protética, uma das infecções mais comumente observadas em pacientes usuários de próteses removíveis. A adesão de C. albicans à superfície das próteses é o primeiro passo para o desenvolvimento da estomatite protética. Assim, uma adequada higienização das próteses é essencial para prevenir a formação de biofilme microbiano sobre a superfície protética e, conseqüentemente, o início e propagação desta infecção. O objetivo deste estudo foi avaliar a efetividade da escovação com diferentes soluções (água destilada, dentifrício, digluconato de clorexidina a 2%, hipoclorito de sódio a 1% e Polident fresh cleanse®) na redução da viabilidade de um biofilme maduro de C. albicans, desenvolvido sobre uma resina termopolimerizável para base de prótese. Para isso, 90 corpos-de-prova circulares foram confeccionados, esterilizados e inoculados com uma suspensão de 107 células/mL de C. albicans. Para a formação do biofilme, todos os corpos-de-prova foram incubados por 48 h a 37 °C sob agitação. A seguir, os corpos-de-prova foram aleatoriamente divididos (n=9) e individualmente submetidos à escovação ou exposição por 90 s nas diferentes soluções avaliadas. Os espécimes imersos em água destilada pelo mesmo período de tempo foram utilizados como controle positivo. Para verificar a efetividade da escovação e dos agentes de limpeza, os corpos-de-prova foram submetidos à avaliação da atividade metabólica das células não removidas de C. albicans por meio do teste do XTT. Os resultados obtidos foram analisados estatisticamente pelos testes de Mann-Whitney e Kruskal-Wallis (α=0.05). A escovação com todos os agentes de limpeza apresentou redução significativamente superior (p<0,0001) na viabilidade do biofilme quando comparada à exposição dos corpos-de-prova... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The adhesion of C. albicans to surfaces is the prerequisite for occurrence of denture stomatitis, a common disease diagnosed among denture wearers. Therefore, a strict routine of denture cleansing is essential to prevent biofilm formation on the acrylic denture surface and the onset of this infection. Thus, the aim of the current study was to investigate the effectiveness of combining toothbrushing and cleansing agents (dentifrice, 2% chlorhexidine gluconate, 1% sodium hypochlorite, and Polident fresh cleanse®) in inactivating C. albicans biofilm. Circular specimens (10 x 2 mm) of acrylic resin denture base material were made, sterilized, and individually inoculated with C. albicans (1x107 colony-forming units/mL). After incubation (37 °C/48 h), the specimens were divided into 10 experimental groups (n=9): 5 subjected to toothbrushing with different cleansing agents and 4 exposed to the cleansing agents without toothbrushing. Non-cleansed specimens were used as positive controls. The viability of cells was evaluated by XTT reduction method. Mann-Whitney and Kruskal-Wallis tests were used for comparative analysis between the two methods of cleansing and the cleansing agents, respectively (α=0.05). Toothbrushing with all agents was significantly more effective (p<0.0001) in reducing biofilm viability than exposure to the cleansing agents only. Exposure to all cleansing agents reduced significantly (p<0.0001) the biofilm viability, with 2% chlorhexidine gluconate being most effective (p<0.0001). Toothbrushing with 2% chlorhexidine gluconate and 1% sodium hypochlorite resulted in 100% inactivation of the biofilm. The use of cleansing agents as an adjunct to toothbrushing is an effective method to reduce C. albicans biofilm viability on denture base resins. / Mestre
25

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas /

Basso, Michael Frederico Manzolli. January 2009 (has links)
Resumo: A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Claudia Helena Lovato da Silva / Banca: Ana Claudia Pavarina / Banca: João Neudenir Arioli Filho / Doutor

Page generated in 0.08 seconds