• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 6
  • 1
  • 1
  • 1
  • Tagged with
  • 32
  • 32
  • 32
  • 19
  • 16
  • 15
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Integração de filtro ativo de potência monofásico e bifásico ao sistema de propulsão de um veículo elétrico

Rodrigues, Márcio do Carmo Barbosa Poncilio 20 November 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-07-21T14:26:57Z No. of bitstreams: 1 marciodocarmobarbosaponciliorodrigues.pdf: 24085481 bytes, checksum: a2ce2552f002816f01354d228d257f85 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-09T13:18:07Z (GMT) No. of bitstreams: 1 marciodocarmobarbosaponciliorodrigues.pdf: 24085481 bytes, checksum: a2ce2552f002816f01354d228d257f85 (MD5) / Made available in DSpace on 2017-08-09T13:18:07Z (GMT). No. of bitstreams: 1 marciodocarmobarbosaponciliorodrigues.pdf: 24085481 bytes, checksum: a2ce2552f002816f01354d228d257f85 (MD5) Previous issue date: 2014-11-20 / A gradativa substituição da atual frota de veículos de motor de combustão interna por veículos elétricos (VEs) pode ser vista como um importante fator para a melhoria das condições ambientais nos centros urbanos, uma vez que possibilita a redução das emissões de poluentes atmosféricos nocivos à saúde humana. Os conversores estáticos existentes no sistema de propulsão de veículos puramente elétricos e híbridos "plug-in" podem ser utilizados para funções adicionais, diferentes da tração elétrica. Com poucas adaptações nos circuitos eletrônicos do VE é possível integrar funções como recarga de baterias, geração distribuída de energia elétrica e compensação de reativos. Este tipo de aplicação é particularmente interessante no contexto de redes inteligentes de energia elétrica (smart grids). Esta integração de funcionalidades ao VE, além de permitir a redução de custos e economia de recursos naturais, poderá resultar em retorno financeiro aos proprietários destes veículos pela prestação de serviços auxiliares ao sistema elétrico. Neste trabalho é proposta a utilização de veículos elétricos na compensação de harmônicos de corrente e de potência reativa em instalações elétricas residenciais e comerciais, utilizando o próprio sistema de propulsão do VE para operar como filtro ativo de potência, o que pode ser realizado de forma simultânea à recarga do banco de baterias do VE ou durante seu uso como unidade de geração distribuída de ener-gia elétrica (operação no modo V2G, vehicle-to-grid). Sendo o padrão de conexão de VEs à rede de energia elétrica atualmente adotado pela maior parte dos fabricantes de automóveis elétricos baseado em alimentação monofásica (com possibilidade de alimen-tação bifásica), é explorada, neste trabalho, a utilização de um VE na compensação de cargas monofásicas e bifásicas, em condições típicas de instalações elétricas residenciais e comerciais, de forma compatível a tal padrão. A inclusão desta funcionalidade aos VEs pode contribuir para a redução do impacto da eletrificação veicular no sistema elétrico, pois com a diminuição do fluxo de potência reativa e harmônica na rede elé-trica, torna-se maior a sua capacidade disponível para transporte de potência ativa, facilitando o suprimento de energia a novas cargas (que podem ser os próprios VEs). / The gradual replacement of the current internal combustion engine vehicles by elec-tric vehicles (EVs) comes up as being an important factor to the improvement of urban centers environmental conditions, since it enables reduction on the emissions of atmo-spheric pollutants harmful to human health. Additional tasks, apart from traction, can be performed by battery and plug-in hybrid electric vehicle powertrain on-board power electronic converters. It is possible to integrate functions such as battery charge, electric distributed power generation and reactive power compensation with few modifications on the EV electronics circuitry. This kind of application is especially interesting under the context of smart grids. The integration of these additional functions to an electric vehicle is a very desirable feature, since it can result on cost reduction (in comparison to the separated implementation of the integrated functions) and revenue to the owner of the vehicle by providing ancillary services to the electric power system. This work proposes the application of electric vehicles on the compensation of cur-rent harmonic components and reactive power in residential and commercial electricity networks by means of the integration of a shunt active power filter (APF) into their powertrain electronics circuitry, which can simultaneously operate with the EV bat-tery pack charging or during its use as an electric distributed power generator unit (vehicle-to-grid, V2G, operation mode). Since the EV grid connection standard cur-rently adopted by electric automobiles manufacturers is based on a single-phase power supply system (with a possible two-phase power supply connection), this work focuses on the application of an electric vehicle in the compensation of single-phase and two-phase loads under residential and commercial electricity networks typical conditions, in order to meet the compliance to the requirements of such standard. The inclusion of this functionality to EVs can contribute on the reduction of vehicular electrification impact on the electric power system, since the decrease of reactive and harmonic power flow into the grid results in higher available capacity of active power flow in the power conductors, which allows to supply electricity to new electric loads (that can be the EVs themselves).
22

Adaptive and Nonlinear Control of a Voltage Source Converter

Milasi, Rasoul M. Unknown Date
No description available.
23

Algumas Contribuições para Algoritmos de Controle de Filtros Ativos e Híbridos Conectados em Paralelo com Redes Elétricas Trifásicas a 3 ou a 4 Fios. / Some Contributions for control algorithms of shunt active and hybrid power filters in 3 or 4-wire power grids.

Cleiton Magalhães Freitas 16 July 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta contribuições para algoritmos de controle utilizados em filtros ativos e híbridos conectados em redes elétricas trifásicas a 3 ou a 4 fios. Em relação aos algoritmos de controle para filtros ativos, a contribuição consiste em estender o conceito da filtragem harmônica seletiva para compensação de correntes harmônicas e desequilibradas em uma rede trifásica a 4 fios. Esses algoritmos derivam dos conceitos utilizados na teoria da potência instantânea (teoria pq), em conjunto com um circuito de sincronismo PLL. É importante ressaltar que estes algoritmos não utilizam as correntes consumidas pelas cargas, ou seja, apenas as tensões no ponto da rede onde o filtro está conectado são utilizadas para determinação das correntes harmônicas de referência. Apenas as correntes na saída do conversor são utilizadas como realimentação do controle PWM. Estes algoritmos também foram utilizados no filtro híbrido para compensação de correntes harmônicas em uma rede trifásica a 3 fios. Por fim foi feito uma alteração nesses algoritmos de controle que permite eliminar as correntes utilizadas na realimentação do controle PWM. Resultados de simulação são apresentados com objetivo de observar o comportamento desses algoritmos tanto no filtro ativo quanto no híbrido nas condições mencionadas. / This work presents some contributions involving control algorithms for active and hybrid filters connected in 3 or 4-wire three-phase electrical grids. In relation to the control algorithms for active filters, the contribution results from the extension involving the concepts of selective harmonic filtering to compensate unbalanced and harmonic currents in a 4-wire three-phase electrical grid. These algorithms derive from the instantaneous power theory (pq theory) together with a synchronizing PLL-circuit. It is important to mention that these algorithm do not use the currents consumed by the loads, i.e, only the voltages at the point common coupling (PCC) are used to determine the reference harmonic currents. Only the output converter currents were used as a feedback to the PWM control. These algorithms were also employed in a hybrid filter to compensate harmonic currents in a 3-wire three-phase electrical grid. Finally, some improvements on these control algorithms were done, such that the output converter currents used as a feedback of the PWM control were eliminated. Simulations results were provided in order to analyze the behavior of the active and hybrid filters in the aforementioned conditions.
24

Modelagem e controle de gerador de indução duplamente alimentado para estudo de sistema de geração eólica / Modeling and control of doubly-fed induction generator for the study of wind generation system

Rocha, Marco Aurélio 27 March 2018 (has links)
Submitted by Marco Aurelio Rocha (rochamarco.eng@gmail.com) on 2018-04-19T12:44:32Z No. of bitstreams: 1 Dissertação_Marco_Rocha_FINAL.pdf: 4334808 bytes, checksum: bcc84d54c373bafcb2362766219becac (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-04-19T18:51:03Z (GMT) No. of bitstreams: 1 rocha_ma_me_bauru.pdf: 4334226 bytes, checksum: d2b0086eaa88031ec113f8e0a415c74c (MD5) / Made available in DSpace on 2018-04-19T18:51:03Z (GMT). No. of bitstreams: 1 rocha_ma_me_bauru.pdf: 4334226 bytes, checksum: d2b0086eaa88031ec113f8e0a415c74c (MD5) Previous issue date: 2018-03-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Esta dissertação apresenta a análise, modelagem e controle vetorial de um sistema de geração eólica tendo um gerador de indução duplamente alimentado como máquina primária e equipado com um conversor back-to-back para gerenciamento da potência entregue ou absorvida da rede elétrica, independentemente do tipo de carga instalada, por meio de compensação de reativos e filtragem ativa das correntes da rede. Para atingir este objetivo, a modelagem do sistema, bem como o projeto dos controladores foram desenvolvidos no ambiente de simulação Matlab®/Simulink®, em que o controle do conversor do lado do rotor realiza a regulação do torque e o controle de potência ativa e reativa, enquanto que o controle do conversor do lado da rede tem a função de manter a tensão do link-CC constante e produzir fator de potência unitário, compensando reativos oriundos do sistema de geração eólica e da carga instalada e atuando como um filtro ativo de potência, melhorando o índice de distorção harmônica da corrente da rede. Além disso, controladores proporcionais-ressonantes foram utilizados a fim de mitigar harmônicos gerados pelo conversor atuando no modo retificador. Também foi realizado o controle do ângulo de passo das pás da turbina, com a finalidade de obter a máxima potência para qualquer velocidade do vento. Os resultados obtidos permitiram avaliar o desempenho dos controladores, de modo que o fator de potência foi mantido unitário para variações abruptas de carga. Tem-se compensação harmônica para cargas não-lineares sendo extraída e gerada a máxima potência oriunda do vento. / This dissertation presents the analysis, modeling and vector control of a wind power system with a doubly-fed induction generator as a primary machine and equipped whit a back-to-back converter to manage power delivered to or absorbed from the grid, independently of the installed load type, through reactive compensation and active filtering of grid currents. To achieve this goal, the system modelling and the controller design was developed in the Matlab®/Simulink® software, where the rotor-side converter control regulates torque and control active and reactive power. The grid-side converter control has the function of maintaining the DC link voltage constant and produce unit power factor, compensating reactive power from the wind generation system and the installed load and acting as an active power filter, which improves the total harmonic distortion of the grid current. In addition, proportional-resonant controller was used to mitigate harmonics generated by the converter acting in the rectifier mode. The pitch angle controller also was made in order to obtain the maximum power for any wind speed. The results obtained allowed to evaluate the performance of the controllers, so that the power factor was unit for abrupt loads variation, there was harmonic compensation for nonlinear loads and the maximum power from the wind was extracted and generated. / CNPq: 13.2999/2016-1
25

Algumas Contribuições para Algoritmos de Controle de Filtros Ativos e Híbridos Conectados em Paralelo com Redes Elétricas Trifásicas a 3 ou a 4 Fios. / Some Contributions for control algorithms of shunt active and hybrid power filters in 3 or 4-wire power grids.

Cleiton Magalhães Freitas 16 July 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta contribuições para algoritmos de controle utilizados em filtros ativos e híbridos conectados em redes elétricas trifásicas a 3 ou a 4 fios. Em relação aos algoritmos de controle para filtros ativos, a contribuição consiste em estender o conceito da filtragem harmônica seletiva para compensação de correntes harmônicas e desequilibradas em uma rede trifásica a 4 fios. Esses algoritmos derivam dos conceitos utilizados na teoria da potência instantânea (teoria pq), em conjunto com um circuito de sincronismo PLL. É importante ressaltar que estes algoritmos não utilizam as correntes consumidas pelas cargas, ou seja, apenas as tensões no ponto da rede onde o filtro está conectado são utilizadas para determinação das correntes harmônicas de referência. Apenas as correntes na saída do conversor são utilizadas como realimentação do controle PWM. Estes algoritmos também foram utilizados no filtro híbrido para compensação de correntes harmônicas em uma rede trifásica a 3 fios. Por fim foi feito uma alteração nesses algoritmos de controle que permite eliminar as correntes utilizadas na realimentação do controle PWM. Resultados de simulação são apresentados com objetivo de observar o comportamento desses algoritmos tanto no filtro ativo quanto no híbrido nas condições mencionadas. / This work presents some contributions involving control algorithms for active and hybrid filters connected in 3 or 4-wire three-phase electrical grids. In relation to the control algorithms for active filters, the contribution results from the extension involving the concepts of selective harmonic filtering to compensate unbalanced and harmonic currents in a 4-wire three-phase electrical grid. These algorithms derive from the instantaneous power theory (pq theory) together with a synchronizing PLL-circuit. It is important to mention that these algorithm do not use the currents consumed by the loads, i.e, only the voltages at the point common coupling (PCC) are used to determine the reference harmonic currents. Only the output converter currents were used as a feedback to the PWM control. These algorithms were also employed in a hybrid filter to compensate harmonic currents in a 3-wire three-phase electrical grid. Finally, some improvements on these control algorithms were done, such that the output converter currents used as a feedback of the PWM control were eliminated. Simulations results were provided in order to analyze the behavior of the active and hybrid filters in the aforementioned conditions.
26

T?cnica de controle adaptativo robusto aplicada a filtros ativos de pot?ncia e paralelo

Braz, ?rico Cadineli 26 March 2010 (has links)
Made available in DSpace on 2014-12-17T14:55:43Z (GMT). No. of bitstreams: 1 EricoCB_DISSERT.pdf: 1960043 bytes, checksum: 7c0ebefa8d09683721a890c3c7d00bbb (MD5) Previous issue date: 2010-03-26 / The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA / Os m?todos para compensa??o de correntes e tens?es harm?nicas v?m sendo bastante utilizados, visto que esses m?todos permitem reduzir a n?veis aceit?veis as distor??es harm?nicas nas tens?es ou correntes em um sistema el?trico de pot?ncia, e ainda, compensar reativos. A redu??o de harm?nicas e reativos contribuem para: a diminui??o das perdas nas linhas de transmiss?o e nas m?quinas el?tricas, o aumento do fator de pot?ncia e a redu??o de ocorr?ncias de sobretens?es e sobrecorrentes. O filtro ativo de pot?ncia ? o m?todo mais eficiente para compensa??o de correntes e tens?es harm?nicas. No filtro ativo de pot?ncia ? necess?ria a utiliza??o de controladores para as malhas de corrente e tens?o. Convencionalmente, o controle dessas malhas tem sido feito por controladores proporcionais integrativos. Neste trabalho, ? investigado o uso de uma t?cnica de controle adaptativo robusto nas malha de corrente e tens?o, do filtro ativo de pot?ncia em paralelo trif?sico, para aumentar a robustez e melhorar o desempenho desse filtro ativo na compensa??o de harm?nicos. A t?cnica de controle proposta ? baseada na combina??o das t?cnicas de controle adaptativo por posicionamento de p?los e de estrutura vari?vel. As vantagens do m?todo proposto sobre os convencionais s?o: menor taxa de distor??o harm?nica, maior flexibilidade, capacidade de adapta??o e robustez para o sistema. Al?m disso, a t?cnica de controle proposta aumenta o desempenho e melhora o transit?rio do filtro ativo. A valida??o da t?cnica proposta foi verificada inicialmente atrav?s de um programa de simula??o implementado em linguagem C ++ e em seguida foram obtidos resultados experimentais usando um prot?tipo de um filtro ativo trif?sico de 1 kVA
27

Integração de um grupo motor gerador diesel em uma rede secundária de distribuição através de um conversor estático fonte de tensão

Fogli, Gabriel Azevedo 19 March 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-26T12:14:24Z No. of bitstreams: 1 gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-26T12:26:45Z (GMT) No. of bitstreams: 1 gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5) / Made available in DSpace on 2017-04-26T12:26:45Z (GMT). No. of bitstreams: 1 gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5) Previous issue date: 2014-03-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta dissertação apresenta um estudo de conexão de um grupo gerador-diesel (GMG) trifásico em uma rede secundária de distribuição de energia elétrica. A integração do GMG é feita por uma unidade de processamento de energia (PPU) composta por um retificador trifásico não controlado conectado em série com um conversor fonte de tensão (VSC) modulado com uma estratégia de modulação por largura de pulso. O GMG pode operar de duas maneiras distintas: (i) modo standby (interligado) ou (ii) modo isolado. O conversor de saída da PPU pode ser controlado para injetar potência ativa na rede CA, ou como um filtro ativo de potência (FAP) compensando potência reativa e correntes harmônicas nos terminais das cargas. O VSC de interface é controlado no modo de corrente (CMC), sendo seus controladores projetados a partir de funções de transferência obtidas com o modelo matemático do sistema elétrico nas coordenadas dq0. Esses controladores são projetados com múltiplos integradores para garantir a qualidade da forma de onda da corrente injetada na rede CA. Dependendo do modo de operação é utilizada uma malha adicional para regular a tensão do barramento CC do conversor de interface. Para validar o modelo matemático e o algoritmo de controle são realizadas simulações digitais no programa PSIM. Resultados experimentais, obtidos com um protótipo de laboratório, cujos controladores foram implementados em um processador digital de sinais TMS320F28335 da Texas Instruments, são usados para validar as estratégias de controle propostas. / This dissertation presents a study about the connection of a three-phase Diesel Genset (DG) to a secondary distribution network. The integration of DG is done by a Power Processing Unit (PPU) composed of a three-phase rectifier connected in series with a Pulse Width Modulated Voltage Source Converter (VSC). The DG can operate in two distinct modes: (i) standby (interconnected) or (ii) islanding. The PPU’s output converter can be controlled to inject active power into AC electric grid, or as an Active Power Filter (APF), compensating the reactive power and harmonics currents at the load terminals. The VSC is controlled employing the current mode control (CMC), and its compensators are designed based on the electrical system transfer function in dq0 coordinates. Multiple rotating synchronous reference frame integrators (PI-MRI) are used to ensure the quality of the generated power. Depending on the operating mode, an additional loop is used to regulate the DC bus voltage. In order to validate the mathematical model and the control algorithm, digital simulations using PSIM are performed. Experimental results obtained with the prototype, which controllers were implemented in a TMS320F28335 of Texas Instruments are used to validate the proposed control strategies.
28

Projeto e simulação de um filtro híbrido monofásico para correção do fator de potência e compensação harmônica em uma rede industrial

Braga, Mateus Freitas 20 March 2017 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-07-03T11:17:42Z No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T21:17:21Z (GMT) No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) / Made available in DSpace on 2017-08-07T21:17:21Z (GMT). No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) Previous issue date: 2017-03-20 / Cresce a cada dia o n úmero de cargas não lineares conectadas aos diversos sistemas el étricos, seja em ní vel de transmissão ou distribui ção. Como consequência desse crescimento, e possí vel encontrar casos de consumidores enfrentando problemas relacionados a desarmes de disjuntores e sobreaquecimento de condutores, entre outros efeitos indesejados. Tomando um desses casos como base para este estudo, esta disserta ção tem o objetivo de avaliar e propor uma solu ção para uma rede monof asica real, que possivelmente e comum a outros consumidores. A carga monof ásica composta por lumin árias a LED (t picas cargas não lineares) e cargas indutivas se apresenta aos terminais da fonte com um comportamento de elevado conte udo harmônico (THD) de corrente e baixo fator de potência. Essa condi ção adversa pode ser mitigada de diversas maneiras, como por exemplo pela a ção de um fi ltro passivo,fi ltro ativo ou ainda fi ltro h brido (o qual e composto por uma combina ção dos dois primeiros). Ser a proposto nesta disserta ção uma metodologia de projeto relacionada a aplica ção de um fi ltro hi brido monof ásico visando corrigir o fator de potência e reduzir o conte udo harmônico de corrente presente na fonte, tomando como base as caracterí sticas do sistema avaliado em uma ind ústria gr áfi ca t ípica. Serão investigadas algumas con gura ções de filtros com o objetivo de mitigar problemas de Qualidade de Energia El étrica. Como consequência, ser a desenvolvida a an álise matem atica da topologia adotada e o projeto do controlador, baseado em um controlador proporcional-ressonante e na Teoria p-q Monof asica. A veri ca ção da solu ção proposta e sustentada pelos resultados de simula ção obtidos via software PSIM. / The amount of non-linear loads connected to the various electrical systems grows on a daily basis, regardless those loads are tied to a transmission or distribution bar. As a consequence of this growth, it is possible to nd cases of consumers facing problems such as tripping of breakers and cables overheating, among other undesired e ects. Taking one of these cases as the focus of this study, this dissertation aims to evaluate and propose a solution to a real single-phase system, which could be considered similar to other consumers. The single-phase load composed of LED luminaires (typical non-linear load) and inductive loads presents high THD and low power factor behavior at source terminals. This condition can be mitigated by using some well-known techniques, such as passive lters, active lters or hybrid lters, (which are composed by the combination of the former two). This Master document Thesis proposes a design methodology of a single-phase hybrid lter aiming power factor correction and reduction of the harmonic content of the current delivered by the AC power supply when feeding a typical printing factory. It will be reviewed and discussed some possible lter con gurations aimed to solve the case under evaluation. It is also included the mathematical analysis of the proposed topology, along with the design of the control system of the inverter. The Single-Phase p-q Theory is reviewed in order to design the control. The closed-loop control is desinged by a proportional-resonant compensator. Simulation results, by employing the PSIM software, are provided aiming to validate the solution proposed.
29

Approches neuromimétiques pour l'identification et la commande des systèmes électriques : application au filtrage actif et aux actionneurs synchrones / Neural networks approaches for identification and control of electrical systems : application to actif power filters and permanent-magnet synchronous motors

Nguyen, Ngac Ky 02 December 2010 (has links)
Cette thèse propose des approches neuromimétiques d'identification et de commande avec des applications directes au Filtre Actif Parallèle (FAP) et au Moteur Synchrone à Aiment Permanent (MSAP). Une structure neuronale complète a été développée pour réaliser toutes les fonctionnalités d'un FAP pour compenser des harmoniques de courant. La phase instantanée et les composantes symétriques d'un système triphasé de tensions ou de courants ont été estimées avec une boucle à verrouillage de phase neuronale. L'identification des harmoniques de courant a été réalisée avec des réseaux de neurones de type Adaline opérant dans les différents repères. Plusieurs schémas de commande ont été développés pour réinjecter les courants de compensation à l'aide d'un onduleur. Ils sont basés sur des techniques neuromimétiques, sur la logique floue, ou sur leur association. Une approche neuronale a été développée pour commander une MSAP à distribution quelconque avec des contraintes prédéterminées réduisant les ondulations du couple. Elle consiste en des schémas de commande directe en couple ou en vitesse pour obtenir les courants statoriques optimaux qui donnent exactement le couple électromagnétique (ou la vitesse) désiré et qui réduisent au maximum les pertes par effet Joule. Ces commandes intègrent deux blocs neuronaux, l'un dédié au calcul des courants optimaux et l'autre pour assurer leur génération à travers un onduleur de tension. Toutes les approches neuromimétiques ont été validées par des tests de simulation et des essais expérimentaux. Des comparaisons avec les méthodes de commande classique démontrent des caractéristiques supérieures en termes de performance et de robustesse. / This thesis proposes Artificial Neural Networks (ANN) approaches for the identification and the control of an Active Power Filter (APF) and a Permanent-Magnet Synchronous Motor (PMSM). A completed neural architecture was developed for an APF for harmonic currents compensation. The instantaneous phase and the symmetrical components of a three-phase voltage or current were estimated with a neural phase Jock loop. The harmonic terms were identified by Adaline neural networks that estimate the instantaneous powers within different reference frames. Several intelligent techniques, based on neural networks, fuzzy logic or their association, were developed to control the inverter used to inject the harmonic currents phase-opposite. An original neural approach was also carried out for reducing the torque ripple of a non-sinusoidal PMSM. It consists in a direct torque or in a speed control schemes that elaborate the optimal stator currents which exactly give a desired electromagnetic torque or speed and which minimize the ohmic losses. The control schemes integrate two neural networks, one to calculate the optimal currents and one to ensure their generation through an inverter. The neural network approaches were all evaluated by simulated and experimental tests. The results confirm their excellent characteristics in terms of both performance and robustness. Comparisons with conventional methods prove their superiority.
30

Optimization of rectifiers for aviation regarding power density and reliability / Optimierung von Gleichrichtern für die Luftfahrt unter Berücksichtigung von Leistungsdichte und Zuverlässigkeit

Liebig, Sebastian 01 June 2015 (has links) (PDF)
The intentions of the so-called "More Electrical Aircraft" (MEA) are higher efficiency and lower weight. A main topic here is the application of electrical instead of hydraulical, pneumatical and mechanical systems. The necessary power electronic devices have intermediate DC-links, which are typically supplied by a three-phase system with active B6 and passive B12 rectifiers. A possible alternative is the B6 diode bridge in combination with an active power filter (APF). Due to the parallel arrangement, the APF offers a higher power density and is able to compensate for harmonics from several devices. The use of the diode bridge rectifier alone is not permitted due to the highly distorted phase current. The following investigations are dealing with the development of an active power filter for a three-phase supply with variable frequency from 360 to 800 Hz. All relevant components such as inductors, EMC-filters, power modules and DC-link capacitor are designed. A particular focus is put on the customized power module with SiC-MOSFETs and SiC-diodes, which is characterized electrically and thermally. The maximum supply frequency slope has a value of 50 Hz/ms, which requires a high dynamic and robustness on the control algorithm. Furthermore, the content of 5th and 7th harmonics must be reduced to less than 2 %, which demands a high accuracy. To cope with both requirements, a two-stage filter algorithm is developed and implemented in two independent signal processors. Simulations and laboratory experiments confirm the performance and robustness of the control algorithm. This work comprehensively presents the design of aerospace rectifiers. The results were published in conferences and patents. / Hauptziele des sogenannten "More Electrical Aircraft" (MEA) sind Effizienzerhöhung und Gewichtseinsparung. Ein Schwerpunkt hierbei ist die Nutzung von elektrischen statt hydraulischen, pneumatischen und mechanischen Systemen. Die notwendigen Leistungselektroniken haben DC-Zwischenkreise, welche mittels aktiven B6 und passiven B12 Gleichrichtern aus dem Dreiphasennetz gespeist werden. Eine mögliche Alternative ist die B6 Diodenbrücke in Kombination mit einem aktiven Netzfilter, welcher aufgrund der parallelen Anordnung eine höhere Leistungsdichte aufweist und darüber hinaus mehrere Geräte gleichzeitig entstören kann. Die alleinige Nutzung einer Diodenbrücke ist aufgrund des hohen Anteils von Stromharmonischen nicht zulässig. Diese Arbeit beschäftigt sich mit der Entwicklung eines aktiven Filters für ein Dreiphasensystem mit variabler Frequenz von 360 bis 800 Hz. Es werden alle relevanten Bauteile wie Induktivitäten, EMV-Filter, Leistungsmodule und Zwischenkreiskondensator ausgelegt. Besonderes Augenmerk liegt auf dem kundenspezifischen Modul mit SiC-Dioden und SiCMOSFETs, welches vollständig elektrisch und thermisch charakterisiert wird. Die Änderung der Netzfrequenz beträgt bis zu 50 Hz/ms, was eine hohe Dynamik und Robustheit von der Filterregelung verlangt. Weiterhin ist im statischen Fall eine hohe Genauigkeit gefordert, da die 5. und 7. Harmonische auf unter 2% geregelt werden müssen. Um beiden Anforderungen gerecht zu werden, wird ein zweistufiger Regelungsalgorithmus entwickelt der auf zwei digitalen Signalprozessoren implementiert wird. Simulationen und Labormessungen bestätigen die Robustheit des Regelungskonzeptes. Diese Arbeit stellt umfassend die Entwicklung von Luftfahrtgleichrichtern dar. Die Ergebnisse wurden in Konferenzen und Patenten veröffentlicht.

Page generated in 0.1028 seconds