• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Avaliação da dentina de dentes decíduos submetidos à técnica de remoção parcial de tecido cariado

Dalpian, Débora Martini January 2009 (has links)
O objetivo deste estudo foi avaliar a microdureza Knoop da dentina cariada remanescente de dentes decíduos submetidos ao capeamento pulpar indireto (CPI) e restaurados com sistema adesivo autocondicionante e resina composta, associado ou não a uma base forradora de cimento de hidróxido de cálcio. Para tal, molares decíduos submetidos ao CPI e restaurados com Clearfil SE Bond – Kuraray, Japão (CSE) e resina composta Filtek Z250 – 3M Espe, EUA foram acompanhados clínica e radiograficamente até a esfoliação. Foram coletados 7 dentes do grupo onde foi aplicado o Dycal – Dentsply, EUA (DY) e 10 com CSE sobre o remanescente cariado e comparados com 10 molares decíduos hígidos com preparo cavitário in vitro de 3 a 4 mm de profundidade, e 10 molares decíduos cariados, submetidos a RPTC in vitro. As mensurações de microdureza foram realizadas, após secção e polimento, a partir da porção mais profunda da cavidade em direção à câmara pulpar nas profundidades de 10, 35, 60, 85, 110, 200μm e, a partir desta, pontos equidistantes 100μm até atingir o teto da câmara pulpar. Entre os grupos CSE e DY não houve diferença nos valores de microdureza em todas as profundidades, porém quando comparados aos Cariados, o CSE apresentou valores significativamente maiores a partir da profundidade 35μm, enquanto esse aumento só foi detectado em 200μm no DY. A partir de 700μm não ocorreu diferença nos valores de microdureza entre todos os grupos. Com base nos resultados, conclui-se que os dentes decíduos submetidos ao CPI apresentaram aumento da microdureza, independentemente do uso de base forradora de Dycal ou CSE. / The aim of this study was to evaluate remaining carious dentin microhardness from deciduous teeth submitted to Indirect Pulp Treatment (IPT) and restored with self etching primer and composite, associated or not with calcium hydroxide capping. Deciduous molars treated with IPT and restored with Clearfil SE Bond – Kuraray, Japan (CSE) and composite Filtek-Z250 – 3M ESPE, EUA were clinically and radiographically evaluated until exfoliation. Seven teeth capped with calcium hydroxide (Dycal – Dentsply, EUA – DY) and 10 with CSE were collected and compared with 10 sound deciduous molars where 3- to 4-mm deep cavities were prepared, and also with 10 carious molars were partial caries removal was conducted in vitro. Microhardness analysis was performed after sample sectioning and polishing, at 10-, 35-, 60-, 85-, 110- and 200-μm depths and later each 100μm until reaching the pulpar chamber roof. No difference was observed in microhardness values between CSE and DY groups in all depths analyzed, otherwise when compared with carious group, CSE presented significantly higher values from 35μm depth, while this increase was observed only with 200μm in the DY group. From 700μm depth no difference was observed in the microhardness values between all groups in study. It can be concluded that deciduous teeth submitted to IPT presented a hardness increase, independently of the capping material type, Dycal or CSE.
312

Pentóxido de nióbio como carga para materiais de base polimérica para uso odontológico

Leitune, Vicente Castelo Branco January 2012 (has links)
O objetivo desta tese foi caracterizar o pentóxido de nióbio (Nb2O5), produzir materiais compósitos de matriz polimérica de uso odontológico e avalia-los. As partículas de Nb2O5 foram caracterizadas com difração de raios-X, microscopia eletrônica de varredura, granulometria a laser, método de Brunauer–Emmett–Teller e espectroscopia micro-Raman. Um adesivo experimental foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 5, 10 e 20 %, em peso). Este adesivo foi avaliado quanto à radiopacidade, grau e cinética de conversão, microdureza e a sua interface com a dentina. Um cimento endodôntico experimental de cura dual também foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 80, 100 e 120 %, em peso). Este cimento foi avaliado quanto à radiopacidade, escoamento, espessura de película, microdureza e grau de conversão (imediatamente, 7 dias e 14 dias após a fotoativação). A avaliação do Nb2O5 mostrou que as partículas utilizadas apresentavam estrutura monoclínica, com formato irregular, com tamanho médio de 38,16 μm, área de superfície de 3,86 m2/g e estrutura química compatível com pentóxido de nióbio. A radiopacidade e dureza do adesivo aumentaram com a incorporação do Nb2O5 e ele pode ser detectado no interior da interface dentina/adesivo. No cimento endodôntico a incorporação do Nb2O5 também aumentou a radiopacidade e a dureza e reduziu o escoamento apenas no grupo com 120 %. O grau de conversão aumentou até 14 dias após a fotoativação, com exceção do grupo com 80%. Após a caracterização do Nb2O5 e da produção dos materiais experimentais, foi feito o depósito de pedido de patente de invenção. Conclui-se que o pentóxido de nióbio é uma nova e promissora partícula para uso em Odontologia como agente de carga. / The aim of this thesis was to characterize the niobium pentoxide (Nb2O5), to produce resin-based composite for dental applications and evaluate them. Niobium pentoxide was characterised by X-ray diffraction, surface area, particle size, micro-Raman and scanning electron microscopy. An experimental adhesive resin was formulated with 0, 5, 10 and 20 wt% Nb2O5. The formulated adhesive resins were evaluated based on microhardness, degree of conversion, radiopacity and interface (resin/dentin) characterisation by micro-Raman. An experimental dual-cured root canal sealer was produced with a methacrylate-based comonomer blend. Nb2O5 was added at four different concentrations: 0, 80, 100 and 120wt%. Radio-opacity, flow, film thickness, microhardness and degree of conversion (after 1, 7 and 14 days) were evaluated. The particles used in this study presented a monoclinic crystalline phase with typical chemical groups, mean size of 38.16 μm and 3.86 m2/g of surface area. Microhardness and radiopacity increased with higher amounts of Nb2O5, and the particles were able to penetrate into the hybrid layers. Microhardness and radiopacity increased with higher amounts of Nb2O5 in the adhesive resin, and the particles were able to penetrate into the hybrid layers. For the endodontic cement, the radiopacity and microhardness increased with the Nb2O5 addition. The flow was significantly smaller for the 120% group. All groups except those with 80wt% had higher values for degree of conversion after 14 days than immediately after photocuring. After the Nb2O5 characterization and the production of experimental materials, an application for patent was done. Niobium pentoxide is a new and promising filler for dental materials production.
313

Influência da desproteinização dentinária radicular na cimentação de pinos estéticos

Guimarães, Renata Pedrosa 17 December 2012 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-14T13:58:42Z No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-14T13:58:42Z (GMT). No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-12-17 / CAPES / Objetivo: Avaliar o desempenho de cimentos resinosos frente à desproteinização dentinária através de ensaio de cisalhamento por extrusão de pinos de fibra de vidro. Método: Raízes de 83 pré-molares inferiores humanos foram divididas em 2 grupos conforme o tratamento da dentina (Convencional – recomendações do fabricante e Desproteinização – NaOCl 5,0%/1min). Cada grupo foi dividido em 4 subgrupos segundo o cimento utilizado na cimentação dos pinos de fibra de vidro (Relyx ARC/3M-ESPE; SET/SDI; RelyxU100/3M-ESPE; Cement Post/Angelus). Após 1 semana foi realizado o ensaio push-out. O padrão de falha pós-ensaio foi obtido, de cada corpo de prova, por microscopia óptica. Os dados foram analisados pelo teste F (ANOVA) com comparações de Tukey ou de Tamhane e t-Student (α=5%). Para 3 espécimes foi realizada análise em MEV quanto à morfologia da dentina segundo o tipo de condicionamento. Resultados: A desproteinização influenciou positivamente o desempenho do Cement Post (Terço médio) e Relyx U100 (Terço apical), negativamente para o RelyxARC (Terços cervical e apical) e indiferentemente para o SET. O RelyX U100 e ARC apresentaram os maiores valores de adesão comparados ao SET e Cement Post. O terço cervical apresentou os melhores resultados, com exceção do RelyX U100, no qual o terço apical foi superior. Falhas adesivas foram mais prevalentes no terço cervical (> 50%) e as mistas nos terços médio e apical (>50%). Conclusões: 1. A desproteinização influenciou positivamente a adesão quando empregados o Cement Post (terço médio) e RelyX U100 (terço apical); 2. O Relyx U100 e Relyx ARC obtiveram os melhores resultados
314

Influência da clorexidina gel, etanol e hipoclorito de sódio na resistência de união à dentina radicular e durabilidade adesiva de pinos de fibra de vidro reembasados com resina composta / Influence of gel chlorexidine, ethanol and sodium hypoclorite on the bond strenght to root dentin and adhesive durability of the fiber post relined with resin composite

Cecchin, Doglas 12 September 2010 (has links)
Orientador: Caio Cezar Randi Ferraz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T09:00:03Z (GMT). No. of bitstreams: 1 Cecchin_Doglas_D.pdf: 5848627 bytes, checksum: c2fd006628320385f2b73dadf55f0781 (MD5) Previous issue date: 2010 / Resumo: A resistência de união de pinos à dentina radicular pode ser comprometida ao longo do tempo pela degradação da interface adesiva. Por isso, o objetivo deste estudo foi avaliar o efeito do pré-tratamento da dentina radicular com clorexidina 2% (CHX), etanol 100% (EtOH) e hipoclorito de sódio 5,25% (NaOCl) e a associação dessas substâncias, na resistência de união e durabilidade adesiva de pinos de fibra de vidro reembasados com resina composta à dentina radicular. Também foram avaliadas a técnica úmida (TU) e seca (TS) (secagem com jatos de ar por 5 segundos). No capítulo 1 que compõe este trabalho, os prétratamentos foram: G1(controle)- irrigação com soro fisiológico; G2- TS; G3- CHX por 5 minutos; G4- EtOH por 1 minuto; e G5- CHX por 5 minutos seguido de EtOH por 1 minuto. Logo após, os canais foram secos com cones de papel absorvente (TU) e a dentina hibridizada com Scotch Bond. No G2, após a TU foi realizada TS. Pinos fibra de vidro reembasados com resina composta foram cimentados com Rely X ARC. Cada grupo foi dividido em 3 subgrupos: 24 horas de armazenamento em água; 12 meses em água; 12 meses em óleo. Todos as raízes foram seccionadas, o teste de push-out realizado e os valores de resistência de união analisados estatisticamente pelos testes ANOVA/Tukey's (a=0,05). Os grupos imediatos apresentaram valores similares (P>0,05), com exceção da TS que resultou em menores valores de resistência de união (P<0,05). A CHX preservou os valores nos grupos estocados por 12 meses (P>0,05), e os demais grupos estocados apresentaram redução nos valores de resistência de união (P<0,05). Pode-se concluir que apenas a CHX foi capaz de preservar os valores de resistência por 12 meses. No capítulo 2, foi realizado o pré-tratamento da dentina radicular com NaOCl isolado e em associação com CHX e/ou EtOH, além da realização da TU e TS. O sistema adesivo, os demais procedimentos e análise estatística foram similares ao capítulo 1. Os resultados mostraram maiores valores de resistência de união nos grupos onde apenas o NaOCl foi utilizado ou associado à CHX, com a TU ou TS, nos grupos imediatos e armazenados por 12 meses (P>0.05). Nos grupos onde EtOH foi utilizado, os valores de resistência de união foram menores (P<0,05). Foi possível concluir que o NaOCl isolado ou associdado com CHX foi capaz de preservar os valores de resistência de união por 12 meses. No capítulo 3, os grupos foram iguais aos do capítulo 1, no entanto a TS não foi estudada e o adesivo utilizado foi o Clearfil SE Bond. O preparo das amostras e análise estatística foram similares ao capítulo 1. Os grupos imediatos apresentaram valores similares de resistência de união (P>0,05). Houve diminuição significante nos grupos controles após 12 meses de armazenamento (P<0,05). O uso de CHX e/ou EtOH preservou os valores de resistência de união por 12 meses (P>0,05). Pode-se concluir que o pré-tratamento da dentina com CHX e/ou EtOH foi capaz de preservar a resistência de união por 12 meses. / Abstract: The bond strength of posts to root dentin can be compromised over time by adhesive interface degradation. Therefore, the aim of this study was to investigate the effects of pre-treatment of root dentin with 2% chlorhexidine (CHX), 100% ethanol (EtOH) and 5.25% sodium hypochlorite (NaOCl), as well as the association of these substances, on the bond strength and adhesive durability of fiber posts relined with resin composite to root dentin. The wet (WT) and dry (ST) (air-drying for five seconds) techniques were also evaluated. The first chapter of this work, the pre-treatments were: G1-control, irrigation with physiologic solution; G2, ST; G3, 5 minutes with CHX; G4, 1 minute with EtOH; and G5, 5 minutes with CHX followed by 1 minute EtOH. Afterwards, the root canals were dried with absorbent paper cones (WT) and the dentin hybridized with Scotch Bond. In G2, after WT was realized ST. Fiber post relining with resin composite was cemented with RelyX ARC. Each group was randomly divided into three subgroups: 24 h of water storage, 12 months of water storage, and 12 months of oil storage. All roots were sectioned transversely, the push-out test was performed and bond strength values were analyzed by ANOVA/Tukey's test (a=0.05). Immediate groups showed similars bond strengths (P>0.05), except that the ST significantly decreased bond strength (P<0.05). The use of CHX preserved bond strength in the groups stored in water and oil for 12 months (P>0.05). The other groups stored for 12 months showed a significant decrease in bond strength (P<0.05). It may be concluded that CHX preserved the bond strength for 12 months. In the second chapter, pretreatment of root dentin was performed with NaOCl alone, and associated with CHX and/or EtOH. In addition ST and WT were performed. The adhesive system, the sample preparation and statistical analysis were similar to those used in the first chapter. The results showed that the groups in which NaOCl was used alone or associated with CHX showed the highest bond strength values with ST or WT in the immediate and groups stored for 12 months (P>0.05). The groups that used EtOH showed lower bond strength and there was a statistical similarity between them (P<0.05). It may be concluded that the use of NaOCl or NaOCl associated with CHX preserved the bond strength to root dentin for 12 months. In the third chapter, the treatments were the same as those in the first chapter. However, the ST was not studied and the adhesive used was Clearil SE Bond. The sample preparation and statistical analysis were similar to those used in the first chapter. Immediate groups showed similar bond strength values with or without CHX and/or EtOH pre-treatment (P>0.05). A significant decrease in the bond strength was observed in the control groups after 12 months of storage in water and oil (P<0.05). It may be concluded that the use of CHX and/or EtOH preserved bond strength in the groups stored in water and oil for 12 months (P<0.05). / Doutorado / Endodontia / Doutor em Clínica Odontológica
315

Efeito da clorexidina na resistência de união entre adesivo autocondicionante e dentina / Effect of chlorhexidine on bond strength between self-etching adhesive and dentin

Pomacóndor Hernández, César Alberto, 1982- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:53:20Z (GMT). No. of bitstreams: 1 PomacondorHernandez_CesarAlberto_M.pdf: 1946502 bytes, checksum: 842f8e2e23f8ff6c74e3ea3a3c2f7637 (MD5) Previous issue date: 2011 / Resumo: Na tentativa de prolongar a durabilidade da união resina-dentina, a clorexidina aparece como uma alternativa para preservar a integridade do componente colágeno não envolvido pela camada híbrida. O presente estudo teve como objetivo avaliar o efeito da clorexidina na interação entre o adesivo autocondicionante de dois frascos Adper SE Plus (3M ESPE) e a dentina nas variáveis: a) resistência de união (RU) após 1 dia, 3 meses e 6 meses de armazenamento em água, e b) padrão de fratura. Foram obtidos oito terceiros molares humanos recém extraídos e livres de cárie. O esmalte oclusal e a raiz foram removidos para obter um bloco de dentina de 4mm de espessura com uma superfície plana em dentina média. Cada bloco foi cortado longitudinalmente em duas metades resultando em oito hemiblocos para cada um dos Grupos Controle (C) e Experimental (CHX). Para o Grupo Controle, o Adper SE Plus foi aplicado seguindo as instruções do fabricante: 1 - aplicação do Líquido A, 2 - aplicação ativa do Líquido B por 20s, 3 - leve jato de ar comprimido durante 10s, 4 - aplicação de uma segunda camada de Líquido B, 5 - leve jato de ar comprimido. O adesivo foi fotoativado durante 10s usando a unidade de luz visível Elipar Freelight 2 (3M ESPE) com intensidade de 900 mW/cm2. Para o Grupo Experimental, foi realizado o mesmo procedimento substituindo o Líquido A por uma solução aquosa de digluconato de clorexidina a 2% em peso. Foram construídos blocos de resina composta Filtek Z250 (3M ESPE) sobre a dentina em seis incrementos de 1mm sendo fotoativados durante 20s cada. Depois de 24 horas de armazenamento em água destilada a 37°C, os hemiblocos restaurados foram seccionados perpendiculares à região adesiva nos sentidos mesiodistal e bucolingual e obtidos de 8 a 10 palitos de 0,9mm2 (±0,2mm2), os quais foram divididos aleatoriamente em três grupos de 2 a 4 palitos cada e avaliados após 1 dia, 3 meses e 6 meses de armazenamento em água destilada a 37°C. Para o teste de microtração cada palito foi submetido à tração sob velocidade de 0,5mm/min em uma máquina de ensaios universais. Os valores de RU foram submetidos à Análise de Variância de dois fatores para medidas repetidas (?=0,05), e os padrões de fratura classificados em Microscópio Eletrônico de Varredura. O Grupo Controle apresentou valores de RU estatisticamente não diferentes entre si após 1 dia, 3 meses e 6 meses de armazenamento (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectivamente). Os valores de RU do Grupo Experimental também resultaram estatisticamente não diferentes entre si nos mesmos tempos de armazenamento (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectivamente). Não houve diferença estatística nos valores de RU entre os Grupos Controle e Experimental. Houve predominância de padrões de fraturas coesiva no adesivo, e mista coesiva no adesivo e na resina composta em ambos os grupos e em todos os tempos de armazenamento. Dentro das condições deste estudo, conclui-se que a RU à dentina do Adper SE Plus não diminuiu com o tempo, e não foi negativamente afetada pela clorexidina a 2% / Abstract: In the search for durability of resin-dentin bond, chlorhexidine appears as an alternative to preserve integrity of collagen component not involved by the hybrid layer. This study aimed to evaluate the effect of chlorhexidine in the interaction between two-bottle self-etching adhesive Adper SE Plus (3M ESPE) and dentin, in terms of bond strength (BS) after 1 day, 3 months and 6 months of water storage, and fracture mode analysis. Eight fresh caries-free human third molars were obtained. The occlusal enamel and roots were removed to obtain a 4mm-thick dentin block with a flat surface in middle dentin. Each dentin block was cut longitudinally into halves resulting in eight hemi-blocks for each of the Control (C) and Experimental (CHX) Groups. For the Control Group, Adper SE Plus was applied following the manufacturer's instructions: 1 - application of Liquid A, 2 - active application of Liquid B for 20s, 3 - gentle compressed air stream for 10s, 4 - application of a second layer of Liquid B, 5 - gentle compressed air stream. The adhesive was light cured for 10s using light unit Elipar Freelight 2 (3M ESPE) with a minimum intensity of 900 mW/cm2. For the Experimental Group, it was performed the same procedure replacing the Liquid A with a solution of 2 wt% chlorhexidine digluconate. Resin composite build-ups were constructed with Filtek Z250 resin composite (3M ESPE) in six increments of 1mm and were light cured for 20s each. After 24 hours storage in distilled water at 37°C, restored hemi-blocks were sectioned perpendicular to the adhesive region in mesiodistal and buccolingual directions and were obtained 8 to 10 beams of 0.9mm2 (±0.2mm2), which were randomly divided into three groups of 2 to 4 beams and evaluated after 1 day, 3 months and 6 months of storage in distilled water at 37°C. For the microtensile test, each beam was tested on tensile until failure at a crosshead speed of 0.5mm/min in a universal testing machine. The BS values were subjected to two-way repeated measures ANOVA (?=0.05), and fracture mode classified in Scanning Electron Microscope. The Control Group had BS values not statistically different from each other after 1 day, 3 months and 6 months of storage (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectively). The BS in the Experimental Group also resulted not statistically different from each other at the same times of storage (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectively). There was no statistical difference in BS values between Control and Experimental Groups. There was a predominance of cohesive failure within adhesive resin, and mixed cohesive failure within adhesive resin and resin composite in both groups at all storage times. Under the conditions of this study, it can be concluded that BS of Adper SE Plus to dentin did not diminish with time, and was not adversely affected by 2% chlorhexidine / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
316

Resistencia a fratura de pre-molares com preparos cavitarios extensos restaurados atraves de sistemas adesivos e não adesivos

Worschech, Claudia Cia 12 May 2000 (has links)
Orientador : Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T01:38:07Z (GMT). No. of bitstreams: 1 Worschech_ClaudiaCia_M.pdf: 487323 bytes, checksum: 63eea6a7fe297dfbe424400140e629bb (MD5) Previous issue date: 2000 / Resumo: O propósito deste estudo foi avaliar a resistência à fratura de pré-molares superiores com extensos preparos cavitários e restaurados com sistemas adesivos e não adesivos. Trinta pré-molares superiores extraídos e livres de cáries ou fendas foram aleatoriamente divididos em 6 grupos com 5 dentes cada. Os dentes do grupo 1 não receberam preparos cavitários mésio-oclusais (controle positivo). No grupo 2, os dentes receberam preparos cavitários, mas não receberam restaurações (controle negativo). Os grupos 3, 4, 5 e 6 receberam os preparos cavitários e foram restaurados de acordo com os respectivos grupos experimentais: G3: Single Bond + Solitaire; G4: Single Bond + Z250; G5: Amálgama (Dispersalloy); G6: Amálgama (Dispersalloy) + Panavia. Todos os grupos foram submetidos ao teste de resistência à fratura numa Máquina de Ensaio Universal (Instron). O carregamento foi aplicado verticalmente através de uma esfera metálica de 4,7 mm de diâmetro, posicionada sobre as vertentes das cúspides dos pré-molares, numa velocidade de 0,5 mm/ min. As médias de carregamento necessárias para fraturar as amostras em cada grupo foram (em kgf), G6 = 168,46 (A) ; G5 = 155,19 (A) ; G1 = 153,54 (A) ; G4 = 148,86 (A); G3 = 80,08 (B) ; G2 = 20,51 (C). Os resultados do teste de TUKEY revelaram diferenças entre os grupos mostrados acima com letras diferentes. Assim, pôde-se concluir que os pré-molares restaurados através dos materiais citados foram capazes de resistir à fratura tanto quanto um dente íntegro, exceto aqueles restaurados com resina composta Solitaire / Abstract: The aim of this study was to evaluate the fracture resistance of maxillary premolars with large cavities preparations. Thirty extracted maxillary premolars, sound and free from cracks were randomly assigned to six groups of five teeth each. The teeth from group 1 did not receive cavity preparations (positive control). In group 2, the teeth received preparations but did not receive restorations (negative control). From groups 3 to 6, the teeth received MO preparations and were restored according to the following techniques: G3: single Bond + Solitaire; G4: Single Bond + Z250; G5: Amalgam; G6: Amalgam + Panavia. All groups were submitted to fracture resistance test in a Universal Test Machine (Instron). The load was applied vertically through a metallic sphere of 4,7 mm diameter, touching only the cusps and never the restorations or cavity margins. The average load necessary to fracture the samples in each group was (in Kgf), G6= 168,46 (A); G5 = 155,19 (A) ; G1=153,54 (A) ; G4= 148,86 (A); G3= 80,08 (B) ; G2= 20,51 (C). The data were submitted to Tukey¿s test that revealed differences among some groups showed above with different letters. These results show that all materials tested can recover the fracture resistance of maxillary premolars as much as a sound tooth, except Solitaire resin / Mestrado / Dentística / Mestre em Clínica Odontológica
317

Efeito da remoção do colageno na infiltração marginal em restaurações de resina composta utilizando dois sistemas adesivos de frasco unico

Saboia, Vicente de Paulo Aragão 16 February 2001 (has links)
Orientador: Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:22:23Z (GMT). No. of bitstreams: 1 Saboia_VicentedePauloAragao_D.pdf: 2377804 bytes, checksum: b83955fe9c76b5de6e7f36a75db01b3f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o efeito da remoção do colágeno na infiltração marginal de corante na interface adesiva de restaurações de resina composta utilizando dois sistemas adesivos de frasco único, envelhecidas através de ciclagem térmica e estocagem em água durante 1 ano. Foram usadas 40 raízes de terceiros molares humanos recém-extraídos e armazenados em formol a 10%. A câmara pulpar e o ápice radicular foram vedados com resina composta. Cada raiz recebeu dois preparos cavitários cilíndricos com dimensões de 2 mm de diâmetro por 2 mm de profundidade. Após sorteio, foram criados dois conjuntos de 20 raízes cujas cavidades foram restauradas utilizando-se os adesivos Prime & Bond 2.1 (PB-Dentsply) ou Single Bond (SB-3M). Cada porção radicular recebeu uma restauração pela técnica da hibridização (controle) e outra após o tratamento da dentina com NaOCI (hipoclorito de sódio) a 10% por 60 s para remoção de colágeno (teste). Ficaram estabelecidos 4 grupos de 20 cavidades assim distribuídas: G1(PBSH)-PB sem NaOCI; G2(PBCH)-PB com NaOCI; G3(SBSH)- SB sem NaOCI e G4(SBCH)-SB com NaOCI. Todas as cavidades foram restauradas com resina composta Z 100 (3M) de acordo com as instruções do fabricante. Os espécimes foram submetidos a 5000 ciclos térmicos (5-55 °C) e armazenados em água à 37°C. Após 1 ano, os remanescentes radiculares foram vedados e imersos em solução de azul de metileno a 2% por 4 horas. As restaurações, foram seccionadas no sentido longitudinal da raiz e observadas em lupa estereoscópica com 45 vezes de aumento. De acordo com a penetração do corante nas margens da restauração foram atribuídos escores de 0 a 4, os quais foram tabulados e submetidos ao teste Exato de Fisher. A remoção do colágeno reduziu significativamente os índices de microinfiltração para o adesivo à base de acetona (Prime & Bond 2.1) enquanto que para o adesivo à base de água (Single Bond) este tratamento não influenciou os índices de microinfiltração / Abstract: The aim of this study was to evaluate the effect of collagen removaI on the microleakage of two single-bottle adhesive systems. Forty human third molars were selected and each of them received two preparations on its roots. The roots were randomly assigned to be restored using Prime & Bond 2.1(PB-Dentsply) or Single Bond (SB-3M). One of the cavities in each root was treated with 'H IND. 3¿¿PO IND. 4¿ and the other received an additional treatment with 10% sodium hypochlorite (NaOCI) for 60 s before adhesive application for removaI of collagen layer. Four groups were created: G1(PBSH)-PB without NaOCI; G2(PBCH)-PB with NaOCI; G3(SBSH)-SB without NaOCI and G4(SBCH)-SB with NaOCI. All the cavities were restored with Z 100 restorative resin (3M). The specimens were submitted to 5,000 thermal cycles (5-55 °C) and stored in 37°C water for 1 year. After this time the specimens were coated with a varnish except for 1 mm of tooth structure surrounding the restoration and immersed in 2% blue methylene for 4 hours. After rinsing, the restorations were sectioned and two independent observers, using a light microscopy at x45 magnification, scored (0 - 4) the microleakage at the interface between restorative material and tooth. The scores were submitted to Fisher's Exact Test and the results showed that collagen removal reduced significantly the microleakage for Prime & Bond 2.1 and had not effect on microleakage for Single Bond / Doutorado / Dentística / Doutor em Clínica Odontológica
318

Infiltração marginal em restaurações de amalgama de prata sob influencia de formas de condensação e uso de materiais intermediarios na interface marginal

Pinto, Marcia Bueno 15 December 2000 (has links)
Orientadores: Simonides Consani, Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:41:56Z (GMT). No. of bitstreams: 1 Pinto_MarciaBueno_D.pdf: 21339887 bytes, checksum: e010eea03df0ee50f3c87d24d25c9142 (MD5) Previous issue date: 2001 / Resumo: A proposta deste estudo "in vitro" foi avaliar a capacidade de selamento de restaurações de amálgama de prata submetidas à três técnicas de condensação (manual, mecânica e ultra-sônica) utilizando-se, como materiais intermediários, adesivo dentinário, cimento de ionômero de vidro modificado por resina, cimento resinoso, verniz copal e, como controle, somente amálgama. Foram preparadas cavidades tipo classe V na raiz de 210 dentes incisivos de bovinos, com 4 mm no maior tamanho no sentido cervico-oclusal e mésio-distal e 1,5 mm de profundidade com todas as margens localizadas em dentina. Os dentes foram divididos em 5 grupos com 42 dentes em cada um sendo que um dos grupos foi utilizado como controle, sem material intermediário (G1) e cada um dos outros quatro grupo recebeu um material intermediário diferente e as três formas de condensação. Antes da condensação do amálgama (Dispersalloy) as cavidades foram tratadas de acordo com as instruções dos fabricantes com Copalite (G2), Vitremer (G3), Enforce + Prime & Bond 2.1 (G4) e Prime & Bond 2.1(05). As amostras ficaram armazenadas em solução salina durante 30 dias e, a cada 15 dias, foi realizado uma termociclagem que constou de 500 ciclos cada, com tempo de 15 segoem cada banho e temperaturas de 5°C e 55° C. Depois da fadiga térmica as amostras foram mergulhadas em solução de fucsina básica 0,5% à temperatura ambiente durante 24h depois das quais foram lavadas e incluídas em resina acrílica para seccionamento em máquina específica (LABCUT). De cada restauração foram obtidos 3 ou 4 cortes e aquele que apresentou a maior penetração de corante, foi fotografado no Estereomicroscópio e avaliado em graus que variaram entre "0" (sem infiltração) até "3" (máxima infiltração). Os resultados foram submetidos à testes estatísticos de 'X POT. 2¿ e pode-se observar que as formas de condensação não afetaram significativamente a quantidade de infiltração observada. No entanto, quando consideramos apenas a presença ou não de infiltração, os testes estatísticos mostraram que a condensação manual foi superior as outras duas (mecânica e ultrassônica) mostrando uma microinfiltração significativamente menor. Também foi possível verificar que as amostras com Prime & Bond 2.1 e o grupo sem material intermediário mostraram significativamente menos infiltração do que o grupo com Enforce + Prime & Bond 2.1. O grupo com Copalite mostrou um pior resultado apenas quando comparado ao grupo controle sendo semelhante a todos os outros grupos testados. O grupo com Vitremer mostrou-se significantemente melhor do que grupo com Enforce + Prime & Bond 2.1 / Abstract: The purpose of this "in vitro" study was to determine the sealing ability of amalgam restorations submit to 3 condensation techniques underlined with adhesive systems, resin modified glass ionomer, copal varnish and amalgam only, wich was use as control. Class V cavities were made in 210 bovine incisor teeth. The cavities had 4mm in diameter and 1.5mm in depth and were prepared at the root in such way that the margins were established in dentin. Before packing the amalgam (Dispersalloy), the cavities were treated, according to the manufacturer's direction, with Copalite Varnish, Vitremer, Enforce + Prime & Bond 2.1 and Prime & Bond 2.1.The sample remained stored in saline solution for a months and in the meantime they were thennocycled. Each thennocycling comprised of 500 cycles between 5° and 55° C with a dwell time of 15 seconds. After the tennal stress the sample were immersed in 0.5% basic fucsin solution 24 h. and washed. The teeth were embedded in resin acrylic and sectioned in a cutting machine (LABCUT). Three to four buccal-lingual cuts, including the restoration were obtained and the microleakage scored from "0" (no leakage) to "3" (maximum leakage). The highest score for each tooth was considered. Chi-square test was applied to the results and the following observations could be drawn: the 3 different condensation techniques did not significantly affect microleakage. It was also possible to observe that the specimens with Prime & Bond 2.1 and control grup showed signficatly less leakage the Enforce + Prime & Bond 2.1. No significantly difference between Copalite and the other groups, except the was obsered G1(control). The Vitremer was only significantly better than G4 / Doutorado / Doutor em Materiais Dentários
319

Avaliação quantitativa da infiltração marginal em cavidades classe V restauradas com sistemas adesivos monocomponentes e autocondicionantes

Gomes, Fabiana Mantovani 16 February 2001 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T12:25:57Z (GMT). No. of bitstreams: 1 Gomes_FabianaMantovani_M.pdf: 3056554 bytes, checksum: c57f84e6ed491583412ec20944275378 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar quantitativamente a microinfiltração em cavidades classe V restauradas com sistemas adesivos monocomponentes e sistemas adesivos autocondicionantes utilizados com e sem condicionamento ácido. Foram avaliados três sistemas adesivos: Clearfil Megabond; autocondicionante; Single Bond; monocomponente contendo água e álcool como solvente; Prime & Bond 2.1; monocomponente contendo acetona como sol vente. Utilizou-se 132 dentes humanos unirradiculares, divididos em 7 grupos, com 20 restaurações classe V e margens em dentina, para cada sistema adesivo; sendo seis grupos testes onde o mesmo sistema adesivo foi utilizado com e sem condicionamento ácido, e um grupo controle negativo em que os dentes foram restaurados em amálgama. Os corpos de prova foram preparados, termociclados, corados com azul de metileno a 2%, seccionados, triturados e avaliados quantitativamente por leitura em aparelho de espectrofotometria. Verificou-se, através do teste ANOV A, que o não condicionamento da dentina não gerou diferença estatística significativa na microinfiltração dos sistemas adesivos; no entanto, quando ocorreu a utilização do condicionamento ácido o sistema adesivo Single Bond demonstrou menor microinfiltração marginal com diferença estatística significativa dos sistemas Clearfil Megabond e Prime & Bond 2.1 que não diferiram entre si. Quando utilizados de acordo com a recomendação do fabricante, os sistemas adesivos Single Bond (utilizado com condicionamento ácido) e Clearfil Megabond (utilizado sem condicionamento ácido) não diferiram entre si, em relação à microinfiltração / Abstract: The aim of this in vitro study was to evaluate the microleakage with espectrofotometric test, in class V restorations restored with one-bottle adhesive systems and self etching systems used with and without etching the dentin. Three kinds of adhesives systems were used: Clearfil Megabond (Kuraray Co.) self etching system; Single Bond (3M Dental Products) one-bottle adesive system, alcohol and water solvent; Prime & Bond 2.1 (Dentsply De Trey) one-bottle adesive system, acetone solvent. One hundred thirty two human teeth (premo lar) were divided in 7 groups, 20 class V restorations were prepared in dentin for each bonding system. The same adhesive were used with and without the etching agent. A group of amalgam restorations were used as a negative controI. The specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with espectrofotometric testo The results were submitted to ANOV A. It was founded that there was no significantly differences in microleakage between the adhesive systems when no etching agent was used; however the Single Bond adhesive system showed statistically significant less microleakage than Clearfil Megabond e Prime & Bond 2.1 when 37% fosforic acid was used to conditioned dentin. The systems Single Bond and Clearfil Megabond had the same behavior when the manufacture instructions were used, the first one used with etching and the last used no etching / Mestrado / Dentística / Mestre em Odontologia
320

Resistencia a fratura de dentes desvitalizados restaurados atraves de resina composta com ou sem pino intra-radicular

Carlini Junior, Bruno 28 June 1999 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:49:09Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_M.pdf: 4610426 bytes, checksum: 538cfee8d0c314f1cf2b2aad936f610d (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar a influência de pinos intra-radiculares préfabricados sobre a resistência de dentes anteriores tratados endodonticamente, debilitados e restaurados com resina composta, bem como estudar o padrão de fratura. Para isto, oitenta incisivos centrais superiores foram divididos em oito grupos experimentais - dentes com duas cristas marginais removidas: restaurados com compósito odontológico (G1), pino pré-fabricado metálico e compósito (G2) e pino de carbono e compósito (G3); dentes com uma das cristas marginais removidas: restaurados com compósito odontológico (G4), pino metálico mais compósito (G5) e pino de carbono mais compósito (G6); dentes somente com acesso endodôntico restaurados com compósito odontológico (G7); e dentes íntegros como controle (G8). Após a inclusão, dez espécimes de cada grupo foram submetidos ao carregamento tangencial de compressão numa Máquina Universal de Ensaios na velocidade de 0,5mm/min, sob o ângulo de 135°. As médias dos valores de resistência à fratura expressos ~m Kgfforam: G8 = 101,80 (:1: 27,81); G1 = 99,09 (:1: 18,57); G7 = 96,33 (:1: 27,03); G5 = 93,76 (:1: 6,19); G3 = 91,88 (:1: 15,98); G4 = 83,50 (:1: 26,76); G2 = 80,45 (:1: 15,89). A análise estatística não demonstrou diferença significativa entre os grupos (ANO V AlDuncan; a = 0,05). Deste modo, conclui-se que: pinos intra-radiculares não reforçaram dentes anteriores tratados endodonticamente; o fator crista marginal não influenciou na resistência à fratura de dentes anteriores restaurados com resina composta. A avaliação do padrão de fratura demonstrou forte correlação entre presença de pinos intra-radiculares - de carbono ou metálicos - e fraturas radiculares longitudinais (X2 / ~ = 0,66; p < 0,01) / Abstract: The aim of this study was to evaluate the influence of intra-radicular prefabricated posts on the resistance of endodontically treated weakened teeth, restored with composite resin, as well as to study the fracture pattem. Eighty upper central incisors were divided into eight experimental groups - teeth with two marginal bridges removed: restored by composite resin (G 1), metallic prefabricated post plus resin (G2) and carbon fiber post plus resin (G3); teeth with one of the marginal bridges removed: restored by composite resin (G4), metallic post plus resin (G5) and carbon fiber post plus resin (G6); teeth only with endodontic access and restored by composite resin (G7); and sound teeth as control (G8). After the inclusion, ten . specimens of each group were submitted to the compressive force in an Universal Te.sting Machine under 0,5mm/min of velocity and an angle of 135 degrees. The averages ofthe resistance values expressed in Kgfwere: G8 = 101,80 (::I:: 27,81); G1 = 99,09 (::I:: 1.8,57); G7 = 96,33 (::I:: 27,03); G5 = 93,76 (::I:: 6,19); G3 = 91,88 (::I:: 15,98); G4 = 83,50 (::I:: 26,76); G2 = 80,45 (::I:: 15,89). The statistical analysis didn't demonstrate significant difference among the groups (ANO V A/Duncan; a = 0,05). This! results permitted the following conclusions: intra-radicular posts were not able to reinforce endodontically treated teeth; the variable marginal bridge didn't show influence in the fracture resistance of teeth restored with composed resin. The evaluation of the fracture pattem demonstrated strong correlation among presence of intra-radicular posts - metallic or carbon fiber - and radicular longitudinal fractures (X2 / ~ = 0,66; p < 0,01) / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.0471 seconds