• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Efeito da ciclagem mecânica na resistência de união à dentina humana de uma resina composta associada a dois sistemas adesivos / Effect of mechanical cycling on the human dentin bond strength, of a composite associated to two adhesive systems

Bodi, Lucia Helena Vieira Diniz 24 March 2010 (has links)
Diante da grande preocupação atual por sorrisos que também embelezem um rosto, a escolha por materiais estéticos impulsiona pesquisas, que tem como objetivo não só melhorar a qualidade, mas, facilitar o uso desses materiais pelos profissionais. Assim, a proposta desse trabalho foi avaliar a influência da ciclagem mecânica na resistência de união de uma resina composta associada a um sistema adesivo convencional e um autocondicionante à dentina humana hígida por meio de teste de microtração. Para o estudo, foram utilizados 40 terceiros molares humanos hígidos, nos quais as faces oclusais foram lixadas até a obtenção de uma superfície plana com exposição do tecido dentinário. Os dentes foram divididos, aleatoriamente, em quatro grupos (n=10) de acordo com o sistema adesivo utilizado e a realização ou não da ciclagem mecânica: G1 Sistema adesivo Adper Single Bond 2 sem ciclagem mecânica (SB); G2 Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CF); G3 - Sistema adesivo Adper Single Bond 2 com ciclagem mecânica (SBC); G4 - Sistema adesivo Clearfil SE Bond sem ciclagem mecânica (CFC). Blocos de resina composta foram confeccionados nas superfícies dentinárias após aplicação do sistema adesivo correspondente. Após esse passo, os espécimes dos grupos 3 e 4 passaram por ciclagem mecânica enquanto o restante ficou armazenado em água destilada, mantidos em estufa à 37ºC até o momento do recorte dos espécimes para o teste de microtração. Os corpos de prova foram seccionados em planos perpendiculares à área de união para obtenção de espécimes com área de secção transversal aproximada de 1,0 mm², que foram tracionados, em máquina de ensaios universal, a velocidade de 0,5mm/min. Os resultados de resistência de união foram analisados usando o teste estatístico análise de variância e os modos de fratura foram avaliados em lupa estereoscópica (25X). Não foram encontradas diferenças estatísticas entre os grupos (p<0,05). Pôde-se concluir que não houve influência da ciclagem mecânica nos valores de resistência de união da resina composta associada a ambos os sistemas adesivos utilizados. / In face of an increasing concern about a smile profile that also enhances the overall facial appearance (esthetics), the choosing for more esthetic restorative materials, set in motion researches that have as objective not only the improvement of the quality, but also the easiness of use of these materials by clinicians. The purpose of this in vitro study was to evaluate, by means of a micro tensile test, the influence of the mechanical cycling, on the bond strength of a resin composite, associated to a total etch and a self etching adhesive systems, on the surfaces of sound human dentin. For this study, forty freshly extracted third molars had their oclusal surfaces grounded parallel-flat, until the dentin surfaces were completely exposed. The teeth were randomly divided in four groups (n=10) in accordance with the type of adhesive system and the mechanical cycling treatment, being: G1 Adper Single Bond 2 without mechanical cycling (SB); G2 Clearfill SE Bond without mechanical cycling (CF); G3 - Adper Single Bond 2 with mechanical cycling (SBC); G4 - Clearfill SE Bond without mechanical cycling (CFC).Following the application of the adhesive systems, regarding to each experimental condition, blocks of Z-250 composite were built, on the dentinal surfaces. After this step, the G3 and G4 specimens were submitted to the mechanical cycling test, while the G1 and G2 specimens were kept stored in distilled water at 37°C, until the moment of sectioning for the microtensile test. The specimens were seccionated perpendicularly to their adhesive area to obtain beam shaped specimens with approximate cross-section area of 0.8mm2, which were readily submitted to the microtensile test in a universal test machine with a crosshead speed of 0.5mm/min. The fracture modes were evaluated by means of a stereoscopic microscope (25x). There were no significant statistical differences founded in the bond strength values among the tested groups.
362

Adesão à superfície de esmalte clareado: avaliação in vitro por microtração / Adhesion to the bleached enamel surface: in vitro assessment through microtensile

Lago, Andréa Dias Neves 03 June 2009 (has links)
O clareamento e os procedimentos adesivos são soluções muito utilizadas na Odontologia atual. Assim, o objetivo deste trabalho foi avaliar, in vitro, a resistência adesiva ao esmalte clareado através do ensaio mecânico de microtração. Dois sistemas adesivos autocondicionantes (Clearfil SE Bond - Kuraray e Adper Prompt LPop - 3M Espe) e um adesivo convencional (Adper Single Bond 2 - 3M Espe) foram aplicados imediatamente, 7 e 14 dias após o clareamento com peróxido de hidrogênio a 35% (Whiteness HP - FGM) ao esmalte. Foram utilizados 60 dentes bovinos que tiveram a superfície de esmalte planificada e em seguida divididos em 12 grupos (9 experimentais e 3 controles) de acordo com o adesivo empregado e o intervalo entre o clareamento e os procedimentos adesivos. O ensaio de microtração foi realizado 24 h após a confecção das restaurações e a área de fratura foi avaliada através da microscopia eletrônica de varredura. Houve redução significativa da resistência adesiva nos dentes restaurados imediatamente após o clareamento com todos os adesivos utilizados. Após 7 e 14 dias do término do clareamento, os valores de resistência adesiva se igualaram e foram semelhantes aos valores dos grupos controles dos respectivos sistemas adesivos empregados. O adesivo Adper Single Bond 2 apresentou os maiores valores de resistência adesiva e o Adper Prompt L Pop os mais baixos. Houve predominância de fraturas adesivas e mistas em todos os grupos. / Bleaching and adhesive proceedings are solutions much used in current Dentistry. Thus, this work aimed at assessing, in vitro, the adhesive resistance to bleached enamel through the microtensile mechanical trial. Two self-etch adhesive systems (Clearfil SE Bond - Kuraray and Adper Prompt L-Pop - 3M Espe) and a conventional adhesive (Adper Single Bond 2 - 3M Espe) were immediately employed, 7 and 14 days after bleaching with hydrogen peroxide at 35% (Whiteness HP - FGM) in the enamel. 60 bovine teeth were used, which had the enamel surface planned and following randomly divided into 12 groups (9 experimental and 3 controls) according to the employed adhesive and to the interval between the bleaching ending and the adhesive proceedings. The microtensile trial was accomplished 24 hours after the confection of the tooth fillings and the fracture area was assessed through scanning electronic microscopy. There was significant reduction of the adhesive resistance in the filled teeth immediately after bleaching with all employed adhesives. After 7 and 14 days of the bleaching ending, the adhesive resistance values were equated and were similar to the values of the control groups and to the respective adhesive systems employed. The Adper Single Bond 2 adhesive presented the highest adhesive resistance values and the Adper Prompt L-Pop presented the lowest ones. There was predominance of adhesive and mixed factures in all groups.
363

Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva / In vitro evaluation of systems on microtensile bond strength to orrogated dentin with endodontic solutions. Adhesive interface degradation influence

Galafassi, Daniel 27 January 2009 (has links)
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado. / The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.
364

Estudo in vitro da influência da contaminação com Streptococcus mutans e da descontaminação com digluconato de clorexidina 2% na resistência de união de sistemas adesivos à dentina humana / In vitro study of the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on bond strength of adhesive systems to human dentin

Bengtson, Camilla Regina Galvao 21 June 2007 (has links)
O objetivo desse trabalho foi avaliar, in vitro, a influência da contaminação com Streptococcus mutans e da desinfecção com solução de digluconato de clorexidina 2% na adesão de dois sistemas adesivos (um sistema adesivo com condicionamento ácido prévio e um sistema adesivo autocondicionante) à dentina de molares humanos. Para o estudo, foram utilizados 80 terceiros molares humanos hígidos, com a face oclusal lixada até a exposição de uma superfície plana de dentina. Os dentes foram divididos aleatoriamente em 8 grupos (n=10) de acordo com o sistema adesivo utilizado e tratamento superficial realizado: G1 ? Controle Single Bond 2 (SB); G2 ? Controle Clearfil SE Bond (SE); G3 ? Desinfecção com clorexidina SB; G4 ? Desinfecção com clorexidina SE; G5 ? Contaminação com Streptococcus mutans SB; G6 ? Contaminação com Streptococcus mutans SE; G7 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SB e G8 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SE. Corpos de prova em resina composta foram confeccionados nas superfícies tratadas e os dentes foram armazenados em água destilada à 37ºC por 24 horas. As amostras foram seccionadas verticalmente obtendo-se espécimes com área de secção transversal de aproximadamente 0,8mm2, que foram tracionados a velocidade de 0,5mm/min em máquina de ensaios universal. Cinco espécimes de cada grupo tiveram a interface adesiva analisada em microscopia eletrônica de varredura (MEV). Os resultados de resistência de união foram analisados usando os testes estatísticos ANOVA e Tukey (p<0,05). Os modos de fraturas foram avaliados por meio de lupa esteroscópica (25X). Discos de dentina foram obtidos de 6 dentes adicionais, para observação em MEV das superfícies submetidos aos mesmos tratamentos realizados para o teste de microtração. Não foram encontradas diferenças estatísticas entre os grupos controles (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), o tratados com clorexidina (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) e os grupos que foram submetidos à contaminação com Streptococcus mutans e descontaminação com clorexidina (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). Os grupos submetidos à contaminação com Streptococcus mutans que não foram descontaminados antes da aplicação dos sistemas adesivos tiveram resultados significantemente menores que os grupos estéreis e descontaminados (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). O sistema adesivo Clearfil SE Bond apresentou valores de resistência de união significantemente maiores que o sistema adesivo Single Bond 2, independente do tratamento da superficial dentina. Pôde-se concluir que a contaminação in vitro com Streptococcus mutans comprometeu a adesão dos dois sistemas adesivos e a solução de digluconato de clorexidina 2% foi capaz de eliminar a contaminação, restabelecendo os valores de resistência de união obtidos com o substrato estéril. / The purpose of this study was to evaluate, in vitro, the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on the bond strength of two adhesive systems (an etch-and-rinse system and a self-etch system) to human dentin molars. Flat dentinal surfaces were prepared in 80 extracted human third molars. Teeth were randomly divided into 8 groups (n=10) according to the adhesive system and the dentin superficial treatment: G1 ? Single Bond 2 (SB) control; G2 ? Clearfil SE Bond (SE) control; G3 ? Desinfection with chlorhexidine SB; G4 ? Desinfection with chlorhexidine SE; G5 ? Contamination with Streptococcus mutans SB; G6 ? Contamination with Streptococcus mutans SE; G7 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SB e G8 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SE. Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37 degrees C for 24 h. Samples were vertically sectioned, obtaining specimens with 0.8mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Five specimens of which group were observed under SEM. Bond strength results were evaluated using ANOVA and Tukey tests(p<0.05). The modes of failures were verified using optical microscope (25X). Dentin disks were obtained from 6 additional teeth treated in the same manner for observation under SEM. No statistically significant differences of bond strength values were found between controls groups (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), groups treated with chlorhexidine (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) and groups contaminated with Streptococcus mutans (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). The groups contaminated with Stretococcus mutans that were not desinfected before the adhesive systems application presented significantly lesser results than sterile or desinfected groups (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). Clearfil SE Bond presented significant high bond strenght values than Single Bond 2, independent of dentin superficial treatment. It was concluded that the contamination in vitro with Streptococcus mutans reduced bond strength of the two adhesives systems and 2% chlorhexidine digluconate solution eliminated the contamination, reestablishing the bond strength values gotten with sterile substrates.
365

Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear test

Shimaoka, Angela Mayumi 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
366

Estratégias para adição de rodamina B em sistemas adesivos / Strategies for adding rhodamine B to bonding agents

Bim Junior, Odair 01 April 2013 (has links)
A rodamina B e outros marcadores fluorescentes vêm sendo empregados na avaliação morfológica da interface de adesão com o auxílio de microscopia confocal de varredura a laser. Acrescentando-se rodamina B a sistemas adesivos, é possível observar as características de espessura da camada de adesivo, micromorfologia da camada híbrida, extensão e quantidade de tags, bem como diagnosticar defeitos ou alterações na interface de adesão. A literatura revela, entretanto, uma falta de precedentes sobre as quantidades de marcadores nos componentes resinosos. Além disso, ainda não se avaliou o efeito da concentração de rodamina B sobre a qualidade da análise da interface de adesão, bem como sobre o comportamento fotofísico dos marcadores nos sistemas adesivos. Este estudo foi realizado com o propósito de sistematizar um método de adição de rodamina B a sistemas adesivos, incluindo-se estratégias para a determinação de concentrações mínimas de rodamina nos componentes resinosos, porém, ainda viáveis para a realização da análise morfológica da interface de adesão através de microscopia confocal de varredura a laser. Para tal, os sistemas adesivos não simplificados e considerados padrão-ouro em suas categorias Adper&#x2122; Scotchbond&#x2122; Multi-Purpose (convencional de três passos) e Clearfil&#x2122; SE Bond (auto-condicionante de dois passos) foram modificados com rodamina B em cinco diferentes concentrações: C1 (0,5 mg/mL), C2 (0,10 mg/mL), C3 (0,02 mg/mL), C4 (0,004 mg/mL) e C5 (0,0008mg/mL) e o comportamento fluorescente da rodamina nos adesivos foi avaliado tanto no âmbito espectroscópico (espectroscopia de fotoluminescência), como no âmbito microscópico (microscopia confocal de varredura a laser). Para a modificação dos adesivos, utilizou-se uma técnica precisa de proporcionamento na qual o marcador fluorescente foi incorporado às resinas fluidas a partir de soluções de rodamina B em etanol. Os espectros de fluorescência mostraram diferenças nos máximos das bandas de emissão e de excitação, de acordo com as concentrações de rodamina B em cada material dispersante. A análise microscópica dos espécimes em dentina confirmou que é possível utilizar sistemas adesivos contendo rodamina B em concentrações muitas vezes menores do que as mencionadas na literatura. Ambos os sistemas avaliados puderam ser visualizados, microscopicamente, quando marcados com rodamina B nas três concentrações pré-selecionadas para a avaliação da interface de adesão: C2 (0,10 mg/mL), C3 (0,02 mg/mL) e C4 (0,004 mg/mL), sendo que C3 forneceu os melhores resultados em relação ao contraste e à saturação nas fotomicrografias. Concluiu-se que o comportamento fotofísico da rodamina B é influenciado tanto pela concentração, como pelo sistema adesivo no qual o marcador está dissolvido. A concentração de rodamina B também interfere na qualidade da análise morfológica da interface de adesão, sendo que o excesso do marcador pode dificultar a distinção de detalhes micromorfológicos. / Rhodamine B and other fluorescent markers have been used for the assessment of the bonding interface via confocal laser scanning microscopy. By adding rhodamine into adhesive systems, it is possible to study morphological characteristics of the hybrid layer, the extent and amount of resin tags and the adhesive layer thickness, as well as detecting potential defects or alterations at bonding interface. Meantime the literature reveals lack of standards among the quantities of fluorescent markers in resin-based polymers. The effects of rhodamine B concentration on the quality of the microscopic analysis, as well as on the photophysics of labeled adhesive systems were not assessed up to now. This study aimed to systematize methodologies for adding rhodamine B into adhesive systems, including suitable strategies for determining the minimum serviceable rhodamine concentrations to perform the morphological analysis of the bonding interface. Two non-simplified adhesive system considered gold standard categories Adper&#x2122; Scotchbond&#x2122; Multi-Purpose (3 steps conventional) and Clearfil&#x2122; SE Bond (2 steps self-etching) were modified with rhodamine B at five concentrations: C1 (0.5 mg/ml), C2 (0.10 mg/ml), C3 (0.02 mg/ml), C4 (0.004 mg/ml) and C5 (0.0008 mg/ml ) and the fluorescent behavior of the labeled resins was assessed both by photoluminescence spectroscopy and by confocal laser microscopy The preparation of the labeled resins was proceed by means of a precise proportioning technique in which the fluorescent marker was incorporated into the bonding agents from solutions of rhodamine B in ethanol. The fluorescence spectra showed differences in the intensity and wavelength fluorescence according to the rhodamine B concentration. Microscopic analysis of the dentin specimens confirmed adhesive systems can be modified with rhodamine B at far lower concentrations than those mentioned in the literature. Both evaluated systems were microscopically visualized while labeled with Rhodamine B at three pre-selected concentrations: C2 (0.10 mg/mL), C3 (0.02 mg/ml) and C4 (0.004 mg/ml), and C3 offered the best outcome with respect to contrast and saturation in photomicrographs. It was concluded that the photophysical behavior of rhodamine B depends on both the concentration and labeled adhesive system. The rhodamine B concentration also interferes with the quality of morphological analysis of the bonding interface, and the excess of the fluorescent marker may jeopardize the discrimination of morphological details.
367

Avaliação da resistência de união de cimentos resinosos, em função de diferentes protocolos, para cimentação de restauração cerâmica em dentina / Evaluation of resin cement bond strength in light of different protocols for the cementation of ceramic restorations in dentin

Oliveira, Damaris Amazonas de 23 May 2013 (has links)
Este estudo avalia a resistência de união à microtração de dois cimentos resinosos (RelyXTM U200 - 3M/ESPE e RelyXTM ARC - 3M/ESPE), na fixação de restauração cerâmica, em função do tipo de tratamento ao substrato dentinário: G1, sem tratamento (cimento autoadesivo RelyX U200); G2, sistema adesivo autocondicionante de dois passos (ClearfilTM SE Bond, Kuraray /RelyXTM ARC); e G3, sistema adesivo convencional de três passos (AdperTM ScotchbondTM Multi- Purpose, 3M/ESPE /RelyXTM ARC). Trinta dentes bovinos foram selecionados, limpos e armazenados em solução neutra de timol a 0,1% a 37oC, sendo divididos aleatoriamente em três grupos experimentais (n=10). O esmalte da face vestibular foi desgastado para expor a superfície dentinária com área de 8 mm x 8 mm e submetido, em seguida, a planificação com lixas de carbeto de silício no 180, 320 e 600. Trinta blocos cerâmicos de dissilicato de lítio, IPS e-max - Ivoclar Vivadent, medindo 8 mm x 8 mm x 2 mm, foram confeccionados e suas superfícies de cimentação jateadas com partículas de óxido de alumínio (50&#x3BC;m). Previamente à cimentação, todos os blocos cerâmicos tiveram suas superfícies internas condicionadas com ácido fluorídrico e foram aplicados agentes silano. Os tratamentos em dentina e os procedimentos de cimentação seguiram as normas dos fabricantes correspondentes para cada grupo. Decorridas 24 horas da cimentação, os conjuntos dente/cimento/cerâmica foram seccionados em forma de vigas, com área aproximada de 1 mm2, adaptados à máquina universal de ensaios (INSTRON) para realização do teste de microtração, utilizando-se a célula de carga de 500N com velocidade de 0,5 mm/minuto. Os valores médios de resistência à microtração (MPa) encontrados foram: G1 (16,16 ± 7,16), G2 (27,92 ± 6,17) e G3 (25,06 ± 6,09). Os dados foram submetidos à análise de variância e ao teste de Tukey em nível de significância de 5%. O cimento resinoso autoadesivo RelyXTM U200 apresentou menor potencial de resistência de união com diferença estatística significante, quando comparado ao cimento resinoso convencional RelyXTM ARC e tratamento prévio com os adesivos convencional de três passos e autocondicionante de dois passos. Entretanto, a associação do cimento RelyXTM ARC tanto ao sistema adesivo convencional quanto ao acondicionante apresentou valores médios similares de resistência de união aos substratos dentinário e cerâmico. Dentre os tipos de fratura, após o teste de microtração, o cimento RelyXTM U200 demonstrou maior ocorrência de falhas do tipo adesiva em dentina (AD), com menor interação adesiva junto à dentina. A associação do sistema adesivo convencional ao cimento resinoso convencional evidenciou menor ocorrência de fraturas AD e maior ocorrência junto à cerâmica, quando comparada à associação do sistema adesivo autocondicionante ao cimento resinoso convencional, apesar de os resultados de resistência de união demonstrarem similaridade de valores e estatística. / This study evaluates the microtensile bond strength of two resin cements (RelyXTM U200 - 3M/ESPE and RelyXTM ARC - 3M/ESPE), in the retention of ceramic restorations according to the treatment type of the dentin substrate; G1: no treatment (RelyX U200 self-adhesive cement); G2: two-step self-etch adhesives (ClearfilTM SE Bond, Kuraray /RelyXTM ARC); and G3: three-step etch and rinse adhesives (AdperTM ScotchbondTM Multi-Purpose, 3M/ESPE /RelyXTM ARC). Thirty bovine teeth were selected, cleaned and stored in a neutral 0,1% thymol solution at 37oC, divided randomly into three experimental groups (n=10). The facial surface enamel was scaled in order to expose an area of 8mm x 8mm of the dentin surface, and subsequently planed with no 180, 320 and 600 silico n carbide sandpaper. Thirty lithium disilicate ceramic blocks, IPS e-max Ivoclar Vivadent, measuring 8mm x 8mm x 2mm were made and their surfaces sandblasted with aluminum oxide particles (50&#x3BC;m). Before cementation, the internal surfaces of all the ceramic blocks were conditioned with hydrofluoric acid and silanized. The dentin treatments and the cementation procedures followed the manufacturers norms for each group. Twentyfour hours after cementation, the tooth/cement/ceramic blocks were sectioned into beam-like structures, each with an approximate area of 1mm2, adapted to the universal testing machine (INSTRON) in order to test microtensile strength, with the load cell set at 500N, at a speed of 0.5mm/min. The mean values found for microtensile strength (MPa) were: G1 (16,16 ± 7,16), G2 (27,92 ± 6,17) and G3 (25,06 ± 6,09). The data were submitted to analysis of variance and to Tukeys test, with a 5% significance level. The self-adhesive resin cement RelyXTM U200 presented the lowest potential bond strength, with a statistically significant difference when compared to the conventional resin cement RelyXTM ARC and prior treatment with three-step etch and rinse adhesives and two-step self-etch adhesives. However the association of the RelyXTM ARC cement, both with the conventional adhesive system and with the self-etch adhesives produced similar mean values for bond strength in the dentin and ceramic substrates. Among the types of fracture, following the test for microtensile strength, the RelyXTM U200 cement presented the highest incidence of faults of the dentin adhesive (DA) type, and the lowest adhesive interaction with the dentin. The association of the conventional adhesive system with conventional resin cement presented a lower incidence of DA fractures and a higher incidence along the ceramics, when compared to the association of the self-etch adhesive system and conventional resin cement, despite the similarity in the numbers and statistics of the bond strength results.
368

Ciência do material bambu e tecnologia de sua aplicação em vigas laminadas coladas de seção transversal composta / Science of bamboo material and technology application in glued laminated cross beams composite section

Nogueira, Cláudia de Lima 15 February 2013 (has links)
No presente trabalho avaliou-se a resistência mecânica do bambu nos estágios pré e pós processamento mecânico para servir de referências básicas do estudo das propriedades mecânicas de vigas laminadas coladas simples, de seção composta e de seção composta na forma de I, industrializadas em laboratório. Iniciou-se com a caracterização do material bruto na forma de ripa que representa toda a parede do colmo, passando-se pelo material processado na forma de lâmina que representam a parte industrialmente útil da parede do colmo e culminando na manufatura e qualificação das vigas laminadas coladas. Na produção dos corpos de prova do material bruto manteve-se a espessura original da ripa, exceto para alguns produzidos para se avaliar a resistência ao cisalhamento radial das camadas interna e externa da parede do colmo. As ripas foram usinadas em diversas máquinas para serem transformadas em lâminas que são as unidades de composição das seções compostas pela técnica de aglutinação e adesão a frio. Foi estudada também a influência do nó na resistência ao cisalhamento radial e tangencial tanto do material sólido quanto do plano de cola e nas propriedades da flexão. A geometria e as dimensões dos corpos de prova de cisalhamento foram adaptadas da norma ASTM D 905 e os de flexão da norma NBR 7190. As resistências ao cisalhamento no plano de cola e as propriedade da flexão foram determinadas segundo três combinações de faces de contato no processo de colagem com o adesivo à base de resorcinolformaldeído (RF). Estudou-se também a pressão adequada para colagem dos corpos de prova e eleita a mais adequada à colagem de vigas laminadas coladas. Os corpos de prova intactos e rompidos nos ensaios foram observados em microscópio eletrônico de varredura, em microscópio óptico, em microscópio óptico de fluorescência e microscópio estereoscópico. Observou-se ampla variabilidade das propriedades mecânicas tanto do material sólido quanto do material composto, mas em qualquer dos casos de resistência houve ampla variabilidade dos dados e, no geral o material sem nó foi mais resistente do que o com nó. As rupturas ocorreram na maioria das vezes no tecido parenquimático desviando-se dos feixes de fibras e tendendo a seguir a grã do material observando que o plano de ruptura só coincide com o plano planejado para a ruptura quando o corpo de prova é feito com a consideração precisa da orientação da grã. Os corpos de prova montados com a cola à base de PVA e com lâminas nodais responderam de forma satisfatória à colagem a baixa pressão, enquanto que os fabricados com lâminas internodais apresentaram melhor desempenho a alta pressão. Para os corpos de prova manufaturados com o adesivo à base de RF, a melhor combinação de colagem se deu no contato entre faces externas de lâminas. Foi possível observar a penetração do adesivo nos elementos anatômicos das lâminas com o uso da microscopia óptica e de fluorescência. As vigas laminadas coladas de seção transversal composta foram ensaiadas à flexão, mas não romperam por tensão normal, pois apresentaram instabilidade lateral durante o carregamento à flexão. As vigas também apresentaram baixo módulo de elasticidade porque o esmagamento da mesa inferior, nos apoios, foi cofundida e somada pelo sistema de medida, ao valor da flecha. Numa análise geral, a qualidade mecânica da Viga \"I\" pode ser considerada muito boa dentro do correto cálculo do momento de inércia se seções transversais compostas. As camadas perpendiculares ao eixo da via, tanto na alma quanto na mesa, foram tão eficientes na absorção do esforço cortante que não houve nenhuma limitação de capacidade de carga pela ligação alma-mesa mesmo com a viga trabalhando numa faixa de alta influência de tensões cisalhantes. / In this study it was evaluated the bamboo strength in the stages before and after mechanical processing in order to obtain basic references to study the mechanical properties of simple glued laminated beams of composite section and composed section as I joist, manufactured in laboratory scale. It started with the characterization of raw material as strip representing the crude bamboo culm wall, moved to the processed material as in the shape of laminas which were representing the majority of bamboo culm wall industrially useful and culminating to the manufacture and qualification of glued laminated beams. In the production of specimens of raw material it was maintained the original thickness for the strip except for a few ones which were produced to evaluate the radial shear strength in the inner and outer layers of the culm wall. The strips were machined on some machines to be turned into laminas that were the units for assembling composite sections by agglutination and adhesion under pressure in environmental conditions. It was also studied the node influence in the radial and tangential shear strength in both solid material and in the adhesive plan and in properties got from the bending tests. The geometry and dimensions of the shear specimens were adapted from ASTM D 905 and the bending from NBR 7190. Shear strength in the adhesive plane and bending property were determined following three combinations of contact faces on the gluing process using resorcinol-formaldehyde based adhesive. It was studied also the proper pressure for gluing the specimens and elect the most suitable for glued laminated beams. The intact specimens and failed on mechanical tests were observed under a Scanning Electron Microscope, Optical Microscope, Optical fluorescence microscope and stereomicroscope. It was observed huge variation of mechanical properties in both solid and composite materials, but in all cases there was considerable variability of strength data and in general the material without node was more resistant than with node. The ruptures mechanisms occurred most often in the parenchyma tissue by passing the fiber bundles and tend to follow the grain of the material by observing the rupture plane that only coincides with the plan designed to rupture when the specimen is done with precise consideration of grain orientation. The specimens manufactured with PVA adhesive and components with nodes responded satisfactorily to the low pressure bonding, while the specimens produced with internodes components performed better at high pressure. For specimens manufactured with resorcinol-formaldehyde adhesive the best gluing combination was given by the contact of outer laminas surfaces to each other. It was possible to observe the anchorage of the adhesive into the anatomical tissues by using optical microscopy and fluorescence optical microscopy. Glued laminated beams with composite cross section were tested in bending, but not failed by normal stresses, once there occurred only lateral instability during loading time. The I beams also showed low modulus of elasticity because the crush in the inferior flange was added by the measurement system to the bending deflection. In general the mechanical quality of the \"I\" joist can be considered very high with correct calculation of the moment of inertia of composite cross sections. The layers perpendicular to the beam axis both in web and in the flanges, were so efficient in absorbing the shear that there was no limitation of carrying load web-frange connection even with the beam working in a critical influence of high shear stresses.
369

Avaliação do grau de sorção, solubilidade e taxa de conversão de sistemas adesivos irradiados com laser de diodo / Evaluation of water sorption/solubility and conversion degree of the adhesive systems irradiated with diode laser

Brianezzi, Leticia Ferreira de Freitas 03 March 2015 (has links)
O LASER tem sido utilizado previamente a polimerização de sistemas adesivos em dentina como uma estratégia para melhorar as suas propriedades. O objetivo deste estudo foi investigar o efeito do LASER de diodo na sorção (SB), solubilidade e grau de conversão das principais categorias de sistemas adesivos. Quatro sistemas adesivos foram testados: convencional de 3 passos (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), convencional de 2 passos (Adper&#x2122; Single Bond 2-SB), autocondicionante de 2 passos (Clearfil&#x2122; SE Bond-SE) e o sistema universal (Adper&#x2122; Single Bond Universal-SU). O adesivo fluido foi dispensado numa matriz de teflon (6.0 x 6.0 x 1 m),irradiado com laser de diodo com 970 nm e polimerizado com luz LED. Para o teste de sorção e solubilidade foram preparados espécimes em uma matriz de teflon quadrada (n=10): MP, SB, SE e SU (sem irradiação) e MP-L, SB-L, SE-L e SU-L (grupos com irradiação). Essa mensuração foi monitorando a mudança de massa depois dos ciclos de armazenamento de desidratação/ água. Para o grau de conversão, espécimes similares eram preparados e divididos 8 grupos iguais (n=5), utilizando a espectroscopia infravermelho transformada de Fourrrier (FTIR) com reflectância total atenuada (ATR). Cada espécime era comprimido contra o cristal do ATR (diamante/ZnSe) com um pressão micrométrica. As amostras não polimerizadas (&#x2248;3.0&#x3BC;L, n=5) de cada adesivo era escaneada para calcular o grau de conversão. Para sorção (&#x3BC;g/mm3) houve diferença estatisticamente significante para ambos os fatores (p<0.05) sem interação entre eles SB> SU> MP> SE. Para a solubilidade (&#x3BC;g/mm3), somente o fator adesivo foi significante (p<0.05): SB>SU>MP=SE. A irradiação do LASER antes da polimerização aumentou o grau de conversão dos sistemas adesivos SBL> MP-L> SE-L> MP> SB> SE> SU-L> SU. A irradiação aumentou a sorção, mas não afetou a solubilidade dos sistemas adesivos. Além disso, a irradiação com LASER de diodo melhorou o grau de conversão de três sistemas adesivos testados. / Laser irradiation has been used over the dentin bonding systems (DBS) prior to polymerization as a strategy to improve their properties. The aim of this study was to investigate the effect of diode laser on water sorption (WS), solubility (WSB) and conversion degree (DC) of main categories of DBS. Four bonding agents were tested: 3-step total-etch (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), 2-step total-etch (Adper&#x2122; Single Bond 2-SB), 2-step self-etch Clearfil&#x2122; SE Bond-SE) and universal system (Adper&#x2122; Single Bond Universal-SU). The fluid DBSs were dispensed into Teflon molds (6.0 x 6.0 x 1mm), irradiated with a 970 nm diode laser and then polymerized with a LED curing unit. For WS/WSB tests, square-shaped DBS were prepared (n=10): MP, SB, SE and SU (control groups/ no laser irradiation) and MP-L, SB-L, SE-L and SU-L (laser irradiated groups). WS/WSB were measured by monitoring the mass changes after dehydration/water storage cycles. For DC tests, similar square-shaped specimens were prepared and assigned into eight similar groups (n=5), using Fourier transform infrared spectroscopy (FT-IR) with attenuated total reflectance (ATR). Each cured specimen was compressed against the ATR crystal (diamond/ZnSe) with a micrometric, low-pressure clamp. Uncured resin samples (&#x2248;3.0&#x3BC;L, n=5) of each adhesive were also scanned for DC calculation. For WS (&#x3BC;g/mm3), both factors were statistically significant (p<0.05), without interaction between them SB>SU>MP>SE. For WSB (&#x3BC;g/mm3), only DBS was a significant factor (p<0.05): SB>SU>MP=SE. Laser irradiation immediately before photopolymerization has increased the DC (%) of the tested adhesives: SB-L> MPL> SE-L> MP> SB> SE> SU-L> SU. Irradiation with diode laser improved the conversion degree of all tested dentin bonding systems. Furthermore the diode laser increased the sorption, but did not affect their water solubility.
370

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Serrano, Luisa Julieth Parra 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.

Page generated in 0.0361 seconds