• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude des mécanismes de vieillissement des batteries Li-ion en cyclage à basse température et en stockage à haute température : compréhension des origines et modélisation du vieillissement / Study of the aging mechanisms of Li-ion batteries in low-temperature cycling and high-temperature storage : understanding of the origins and aging modeling

Pilipili Matadi, Bramy 21 December 2017 (has links)
Afin d'approfondir la compréhension des mécanismes de vieillissement des batteries Li-ion, des analyses post-mortem ont été effectuées sur des cellules commerciales Li-ion C/NMC. Ces autopsies ont révélé des dégradations inattendues qui remettent en question les connaissances actuelles sur les mécanismes de vieillissement de ces cellules. Ainsi, il semble que la réaction parasite des dépôts de Li métallique sur l'électrode en graphite, actuellement associée dans la littérature à des charges à basses températures et / ou à courants élevés, aurait diverses origines selon la chimie et les conditions d'utilisation de la batterie. Dans ce travail de thèse, des dépôts locaux de Li métallique ont été observés sur des cellules vieillies en calendaire à haute température. Paradoxalement, dans des conditions de cyclage à basse température, ce dépôt de Li métallique a résulté de la perte de porosité au niveau de l’électrode négative. Par ailleurs, un modèle de vieillissement semi-empirique, prenant compte les pertes en cyclage ainsi que celles causées par la croissance de la SEI et la polymérisation du biphényl, est proposé. Pour finir, une méthode d'identification des modes de dégradation grâce à des mesures de capacité incrémentale a été entreprise, sur la base du décalage des potentiels de chacune des électrodes. / In order to deepen the understanding of the aging mechanisms of Li-ion batteries, post-mortem investigations were performed on C/NMC Li-ion commercial cells. These autopsies revealed unexpected degradations that question current knowledge about the aging mechanisms of these cells. Thus, it appears that the parasitic reaction of Li metal depositions on the graphite electrode, nowadays associated in the literature with charging at low temperature and / or high C-rates, would have various origins depending on the chemistry and conditions of use of the battery. In this thesis work, local Li deposits were observed on cells aged in calendar at high temperatures, due to the apparition of dry areas. Paradoxically, under low temperature cycling conditions, this Li resulted from anode porosity hindrance. Besides, a semi-empirical aging model, taking into account cycling losses as well as those caused by the SEI growth and the biphenyl polymerization, is proposed. Finally, a method of identifying degradation modes using incremental capacity measurements has been undertaken, based on the potential shifts of each of the electrodes.
2

Influence des transferts hygro-aérauliques sur les transferts thermiques dans les super-isolants nanostructurés sous vide / Influence of gas transfer on heat transfer in evacuated nanoporous super insulation materials

Bouquerel, Mathias 13 December 2012 (has links)
Les panneaux d'isolation sous vide (PIV) sont constitués d'un matériau de coeur nanoporeux en dépression, et d'une enveloppe barrière aux gaz atmosphériques. Leur conductivité thermique initiale est de l'ordre de 5 mW/(m.K), cinq à huit fois inférieure à celle des isolants conventionnels. Au regard des isolants classiques, le questionnement le plus important concerne le couple performance / durabilité. La réponse passe par la compréhension et la modélisation des transferts thermiques et massiques dans les PIV. De nombreuses études expérimentales et numériques ont conduit à un modèle semi-empirique pour la conductivité thermique apparente d'un PIV, prenant en compte les différents modes de transfert dans le panneau. Ce modèle met en lumière le principal mécanisme de vieillissement : du fait de la perméation gazeuse à travers l'enveloppe, pression et humidité dans le panneau remontent au cours du temps, ce qui engendre une augmentation de la conductivité thermique. L'étude des transferts massiques à travers l'enveloppe est particulièrement délicate. Premièrement, la modélisation de la perméabilité des enveloppes utilisées (membranes multicouches de films polymères métallisés) repose sur la prise en compte des micro-défauts dans les couches métallisées, qui gouvernent le débit total de perméation. Deuxièmement, les valeurs des perméabilités à mesurer sont trop basses pour beaucoup de techniques conventionnelles. Troisièmement, une analyse de la littérature montre une lacune de taille en ce qui concerne la prise en compte de l'influence conjointe de la température et de l'humidité relative dans le modèle classique de perméation gazeuse. En se basant sur des données expérimentales existantes, le rôle de l'humidité relative sur les propriétés barrières des enveloppes des PIV est mis en lumière. L'existence d'un couplage entre les flux des différents gaz est posé comme hypothèse de départ à la mise en place d'un nouveau modèle de perméation gazeuse, prenant en compte pression partielle et pression totale, et donc la concentration molaire de chaque gaz dans le mélange. Les prédictions de ce modèle sont comparées à celles issues du modèle classique de perméation gazeuse, et les différences de comportement entre les deux modèles sont mises en avant. Deux séries de mesure de perméance sont ensuite mises en place, par vieillissement de PIV en enceintes climatiques et par mesure directe de perméance sur échantillons de membrane (méthode manométrique). Ces mesures sont menées à température et humidité relative fixées (T = 48 °C, φ = 65 % HR), mais avec une pression totale variant de 80 mbar à 1 bar. Cette campagne de mesure exploratoire ne montre pas d'influence notable de la pression totale sur la perméabilité à la vapeur d'eau. Ces résultats permettent de dresser les premières conclusions sur le rôle respectif de la pression partielle et de la pression totale, et de proposer une suite à la démarche expérimentale initiée dans cette étude. / Vacuum insulation panels (VIPs) are composed of an evacuated nanoporous core material, and a barrier envelope to atmospheric gases. Their apparent thermal conductivity after manufacturing is approximately 5 mW/(m.K), five to eight times lower than that of conventional insulation materials. Compared to conventional insulation materials, the most important issue remains in the duality performance / durability. The answer lies in the understanding and modeling of heat and mass transfer in VIPs. Many experimental and numerical studies about heat transfer led to a semi-empirical model for the apparent thermal conductivity of a VIP, taking into account the different transfer modes in the panel. This model highlights the main mechanism of VIPs aging: due to gas permeation through the envelope, pressure and humidity in the panel increase gradually over time, which causes an increase of the apparent thermal conductivity. The study of mass transfer through the gas barrier envelope is particularly difficult for three main reasons. First, the permeation modeling of VIPs envelopes (multilayer membranes with metalized polymer films) has to take into account micro-defects in the metallic layers, which play a key role in the total permeation rate. Second, the permeances to be measured are too low for many conventional methods, especially for dry air. Third, a literature analysis shows that the classical model for mass transfer through barrier envelopes does not take into account the combined influence of temperature and relative humidity, which is a great lacuna. From experimental data available in the literature, the role of relative humidity on the barrier properties of the VIPs envelopes is highlighted. The existence of a coupling phenomenon between the mass flows of the various gases is hypothesized to start the establishment of a new gas permeation model, which takes into account partial pressure and total pressure, and thus the molar concentration of each gas in the mixture. The predictions of this model are compared with predictions based on the classical model for gas permeation, and the differences between the two models are analyzed. Two experimental campaign are then implemented to measure envelope permeance, through whole VIPs aging in climatic boxes and through direct measurement of the permeance on membrane samples (manometric method). These measurements are carried out at fixed temperature and relative humidity (T = 48 °C, φ = 65 % HR), but with a total pressure ranging from 80 mbar to 1 bar. This exploratory measurement campaign shows no significant influence of the total pressure on the apparent permeability to water vapor. These results are used to draw first conclusions on the respective roles of the partial pressure and the total pressure, and suggest some outlooks to the experimental approach initiated in this study.
3

Fiabilité et robustesse des cartes d alimentations des nouvelles générations des modules RADAR. / Reliability and robustness of electronic power board of the new generations of RADAR modules

Lachkar, Chadia 19 December 2018 (has links)
Aujourd’hui, les exigences croissantes en termes de compétitivité requièrent la conception de systèmes électronique de puissance ayant un encombrement minimal tout en gardant une bonne fiabilité. La combinaison de ces deux caractéristiques est absolument requise au niveau d’un système aussi bien qu’au niveau d’un composant. On cite notamment le cas des condensateurs d’aluminium à électrolyte liquide, qui sont largement utilisés comme réservoir de stockage de l’énergie électrostatique. Cette fonction est nécessaire dans les systèmes électroniques de puissance pour fournir l’énergie aux différentes parties à chaque appel de courant. D’après la littérature, l’étude et l’évaluation de la fiabilité de ces systèmes reposent fortement sur celle des condensateurs d’aluminium à électrolyte liquide ainsi que sur d’autres composants identifiés comme critiques (Transistors MOS de découpage, isolants dans les transformateurs, …etc.). Le premier chapitre débute par une présentation de la technologie des condensateurs est détaillée en indiquant les différents paramètres qui les caractérisent et les différents travaux réalisés dans la littéraire sur l’étude et l’évaluation de la fiabilité de ces composants. Dans le deuxième chapitre, les essais de vieillissement sont élaborés en se basant sur le profil de mission du système. Ensuite, les évolutions des caractéristiques ayant une dégradation significative sont modélisées. Le troisième chapitre porte sur la caractérisation physico-chimique du condensateur afin de comprendre et expliquer les modes de défaillance enregistré pendant les essais de vieillissement. Le dernier chapitre est consacré à la réalisation des essais de vieillissement sur système simulant la dissipation de la chaleur des composants adjacents aux condensateurs. Des mesures électriques sont faites en temps réel afin de superviser la tension à leurs bornes. Enfin, un essai de stress mécanique est réalisé afin de permettre d’évaluer l’impact des vibrations sur la connectique des condensateurs neufs et vieillis. / Today, the increasing demands in terms of competitiveness require the design of electronic power systems having a minimal bulk while maintaining a good reliability. The combination of these two features is required at a system level as well as at a component level. It is particularly the case of liquid electrolyte aluminum capacitors, which are widely used as storage tanks forelectrostatic energy. This function is necessary in electronic power systems to provide energy to the different parts with each current draw. According to the literature, the study and the evaluation of the reliability of these systems rely heavily on that of liquid electrolyte aluminum capacitors as well as on other components identified as critical (MOS switching transistors, insulators in transformers, etc.). The first chapter begins with a detailed presentation of the technology of capacitors by indicating the various parameters that characterize them and the different work done in the literary on the study and evaluation of the reliability of these components. In the second chapter, aging tests are developed based on the mission profile of the system. Then, the evolutions of characteristics having a significant degradation are modeled. The third chapter deals with the physico-chemical characterization of the capacitor in order to understand and to explain the failure modes recorded during the aging tests. The last chapter is devoted to performing aging tests on a system which is simulating the heat dissipation of components adjacent to capacitors. Electrical measurements are realized in real time to monitor the voltage at their terminals. Finally, a mechanical stress test is carried out to evaluate the impact of vibrations on the connection of new and aged capacitors.
4

Aging Propagation Modeling and State-of-Health Assessment in Advanced Battery Systems

Cordoba Arenas, Andrea Carolina January 2013 (has links)
No description available.

Page generated in 0.0755 seconds