• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influence des transferts hygro-aérauliques sur les transferts thermiques dans les super-isolants nanostructurés sous vide

Bouquerel, Mathias 13 December 2012 (has links) (PDF)
Les panneaux d'isolation sous vide (PIV) sont constitués d'un matériau de coeur nanoporeux en dépression, et d'une enveloppe barrière aux gaz atmosphériques. Leur conductivité thermique initiale est de l'ordre de 5 mW/(m.K), cinq à huit fois inférieure à celle des isolants conventionnels. Au regard des isolants classiques, le questionnement le plus important concerne le couple performance / durabilité. La réponse passe par la compréhension et la modélisation des transferts thermiques et massiques dans les PIV. De nombreuses études expérimentales et numériques ont conduit à un modèle semi-empirique pour la conductivité thermique apparente d'un PIV, prenant en compte les différents modes de transfert dans le panneau. Ce modèle met en lumière le principal mécanisme de vieillissement : du fait de la perméation gazeuse à travers l'enveloppe, pression et humidité dans le panneau remontent au cours du temps, ce qui engendre une augmentation de la conductivité thermique. L'étude des transferts massiques à travers l'enveloppe est particulièrement délicate. Premièrement, la modélisation de la perméabilité des enveloppes utilisées (membranes multicouches de films polymères métallisés) repose sur la prise en compte des micro-défauts dans les couches métallisées, qui gouvernent le débit total de perméation. Deuxièmement, les valeurs des perméabilités à mesurer sont trop basses pour beaucoup de techniques conventionnelles. Troisièmement, une analyse de la littérature montre une lacune de taille en ce qui concerne la prise en compte de l'influence conjointe de la température et de l'humidité relative dans le modèle classique de perméation gazeuse. En se basant sur des données expérimentales existantes, le rôle de l'humidité relative sur les propriétés barrières des enveloppes des PIV est mis en lumière. L'existence d'un couplage entre les flux des différents gaz est posé comme hypothèse de départ à la mise en place d'un nouveau modèle de perméation gazeuse, prenant en compte pression partielle et pression totale, et donc la concentration molaire de chaque gaz dans le mélange. Les prédictions de ce modèle sont comparées à celles issues du modèle classique de perméation gazeuse, et les différences de comportement entre les deux modèles sont mises en avant. Deux séries de mesure de perméance sont ensuite mises en place, par vieillissement de PIV en enceintes climatiques et par mesure directe de perméance sur échantillons de membrane (méthode manométrique). Ces mesures sont menées à température et humidité relative fixées (T = 48 °C, φ = 65 % HR), mais avec une pression totale variant de 80 mbar à 1 bar. Cette campagne de mesure exploratoire ne montre pas d'influence notable de la pression totale sur la perméabilité à la vapeur d'eau. Ces résultats permettent de dresser les premières conclusions sur le rôle respectif de la pression partielle et de la pression totale, et de proposer une suite à la démarche expérimentale initiée dans cette étude.
2

Simulation thermo-aéraulique de la ventilation et du transport de polluants dans des cavités : application à la qualité de l'air intérieur et au confort thermique / Thermal and airflow simulation of ventilation and transport of pollutants in cavities : Application to indoor air quality and thermal comfort

Koufi, Lounes 15 December 2015 (has links)
La présente thèse porte sur la prédiction numérique de l’impact des transferts thermique et massique sur la qualité de l’air et sur le confort thermique à l’intérieur des cavités ventilées ou non et remplies de polluant. En effet, les cavités ventilées sont généralement considérées comme étant une approximation pour la modélisation des locaux ventilés.Pour mener à bien cette étude, nous avons choisi un modèle numérique basé sur la résolution des équations régissant les transferts de quantité de mouvement, de chaleur et de masse. La première partie du mémoire est consacrée à quelques généralités sur la ventilation, la qualité de l’air et le confort thermique ainsi qu’à la revue bibliographique des travaux réalisés. La démarche suivie est décrite dans le chapitre 2. Celle-ci est basée sur l’approximation de Boussinesq. Le modèle RNG k-ε est utilisé pour traiter la turbulence. La discrétisation des équations est réalisée à l’aide de la méthode des volumes finis associée à l’algorithme SIMPLEC pour traiter le couplage pression-vitesse. Dans la seconde partie, nous considérons d’abord la convection thermique et la convection thermosolutale dans des cavités fermées. Le principal but visé est: a) de valider le modèle considéré en confrontant nos résultats avec ceux de la littérature et b) d’étudier l’influence du nombre de Rayleigh thermique et du rapport de flottabilité. Les résultats obtenus révèlent que le modèle adopté prédit correctement les transferts thermique et massique.Ensuite, nous appliquons cette approche au cas des cavités bidimensionnelles ventilées soumises à des gradients de température et de concentration. Les indices de qualité de l’air et d’efficacité de la ventilation sont calculés et discutés. Nous achevons ce travail en analysant l’influence de la ventilation sur la qualité de l’air intérieur dans une pièce tridimensionnelle en régime transitoire. Cette analyse concerne différents scénarios de ventilation mécanique simple flux en vue de trouver la meilleure configuration en termes d’efficacité et de qualité de l’air intérieur. / This thesis deals with the numerical prediction of heat and mass transfer impact on the air quality and thermal comfort within either ventilated or not cavities filled with pollutants. Indeed, ventilated areas are first modeled to be as ventilated cavities in a first approximation.To carry out this study, we adopt a numerical model based on solving equations governing momentum, heat and mass transfer. The first part of this thesis is dedicated to some generalities on ventilation, air quality and thermal comfort and the bibliographic review of previous works. The adopted approach is described in Chapter 2. It is based on the Boussinesq approximation. The RNG k-ε model is used to handle turbulence. The finite-volume method (FVM) is used to discretize of the set of equations, and the pressure-velocity coupling is achieved via the SIMPLEC algorithm. In the second part, we consider the thermal convection and thermosolutal convection in closed cavities. The main aim is a) to validate the considered model by comparing our results with those of literature, and b) to investigate influence of the thermal Rayleigh number and the buoyancy ratio. Our findings indicate that the model accurately predicts heat and mass transfer.Then, we apply this approach to the case of two-dimensional ventilated cavities subjected to temperature and concentration gradients. The indices of air quality and ventilation efficiency are calculated and discussed. We end this work by analyzing the influence of ventilation on the quality of indoor air in a three-dimensional room in transient regime. This investigation covers different scenarios from the simple flow mechanical ventilation which aims to find the best configuration in terms of efficiency and quality of indoor air.
3

Influence des transferts hygro-aérauliques sur les transferts thermiques dans les super-isolants nanostructurés sous vide / Influence of gas transfer on heat transfer in evacuated nanoporous super insulation materials

Bouquerel, Mathias 13 December 2012 (has links)
Les panneaux d'isolation sous vide (PIV) sont constitués d'un matériau de coeur nanoporeux en dépression, et d'une enveloppe barrière aux gaz atmosphériques. Leur conductivité thermique initiale est de l'ordre de 5 mW/(m.K), cinq à huit fois inférieure à celle des isolants conventionnels. Au regard des isolants classiques, le questionnement le plus important concerne le couple performance / durabilité. La réponse passe par la compréhension et la modélisation des transferts thermiques et massiques dans les PIV. De nombreuses études expérimentales et numériques ont conduit à un modèle semi-empirique pour la conductivité thermique apparente d'un PIV, prenant en compte les différents modes de transfert dans le panneau. Ce modèle met en lumière le principal mécanisme de vieillissement : du fait de la perméation gazeuse à travers l'enveloppe, pression et humidité dans le panneau remontent au cours du temps, ce qui engendre une augmentation de la conductivité thermique. L'étude des transferts massiques à travers l'enveloppe est particulièrement délicate. Premièrement, la modélisation de la perméabilité des enveloppes utilisées (membranes multicouches de films polymères métallisés) repose sur la prise en compte des micro-défauts dans les couches métallisées, qui gouvernent le débit total de perméation. Deuxièmement, les valeurs des perméabilités à mesurer sont trop basses pour beaucoup de techniques conventionnelles. Troisièmement, une analyse de la littérature montre une lacune de taille en ce qui concerne la prise en compte de l'influence conjointe de la température et de l'humidité relative dans le modèle classique de perméation gazeuse. En se basant sur des données expérimentales existantes, le rôle de l'humidité relative sur les propriétés barrières des enveloppes des PIV est mis en lumière. L'existence d'un couplage entre les flux des différents gaz est posé comme hypothèse de départ à la mise en place d'un nouveau modèle de perméation gazeuse, prenant en compte pression partielle et pression totale, et donc la concentration molaire de chaque gaz dans le mélange. Les prédictions de ce modèle sont comparées à celles issues du modèle classique de perméation gazeuse, et les différences de comportement entre les deux modèles sont mises en avant. Deux séries de mesure de perméance sont ensuite mises en place, par vieillissement de PIV en enceintes climatiques et par mesure directe de perméance sur échantillons de membrane (méthode manométrique). Ces mesures sont menées à température et humidité relative fixées (T = 48 °C, φ = 65 % HR), mais avec une pression totale variant de 80 mbar à 1 bar. Cette campagne de mesure exploratoire ne montre pas d'influence notable de la pression totale sur la perméabilité à la vapeur d'eau. Ces résultats permettent de dresser les premières conclusions sur le rôle respectif de la pression partielle et de la pression totale, et de proposer une suite à la démarche expérimentale initiée dans cette étude. / Vacuum insulation panels (VIPs) are composed of an evacuated nanoporous core material, and a barrier envelope to atmospheric gases. Their apparent thermal conductivity after manufacturing is approximately 5 mW/(m.K), five to eight times lower than that of conventional insulation materials. Compared to conventional insulation materials, the most important issue remains in the duality performance / durability. The answer lies in the understanding and modeling of heat and mass transfer in VIPs. Many experimental and numerical studies about heat transfer led to a semi-empirical model for the apparent thermal conductivity of a VIP, taking into account the different transfer modes in the panel. This model highlights the main mechanism of VIPs aging: due to gas permeation through the envelope, pressure and humidity in the panel increase gradually over time, which causes an increase of the apparent thermal conductivity. The study of mass transfer through the gas barrier envelope is particularly difficult for three main reasons. First, the permeation modeling of VIPs envelopes (multilayer membranes with metalized polymer films) has to take into account micro-defects in the metallic layers, which play a key role in the total permeation rate. Second, the permeances to be measured are too low for many conventional methods, especially for dry air. Third, a literature analysis shows that the classical model for mass transfer through barrier envelopes does not take into account the combined influence of temperature and relative humidity, which is a great lacuna. From experimental data available in the literature, the role of relative humidity on the barrier properties of the VIPs envelopes is highlighted. The existence of a coupling phenomenon between the mass flows of the various gases is hypothesized to start the establishment of a new gas permeation model, which takes into account partial pressure and total pressure, and thus the molar concentration of each gas in the mixture. The predictions of this model are compared with predictions based on the classical model for gas permeation, and the differences between the two models are analyzed. Two experimental campaign are then implemented to measure envelope permeance, through whole VIPs aging in climatic boxes and through direct measurement of the permeance on membrane samples (manometric method). These measurements are carried out at fixed temperature and relative humidity (T = 48 °C, φ = 65 % HR), but with a total pressure ranging from 80 mbar to 1 bar. This exploratory measurement campaign shows no significant influence of the total pressure on the apparent permeability to water vapor. These results are used to draw first conclusions on the respective roles of the partial pressure and the total pressure, and suggest some outlooks to the experimental approach initiated in this study.

Page generated in 0.0669 seconds