• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 24
  • 24
  • 9
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Perfil de resistência aos antimicrobianos em coliformes isolados do Sistema Municipal de Abastecimento de Água de São José do Rio Preto-SP /

Pereira, Luciângela de Oliveira. January 2013 (has links)
Orientador: Mara Corrêa Lelles Nogueira / Banca: Miyoko Jakabi / Banca: Márcia Cristina Bisinoti / Resumo: Bactérias resistentes aos antimicrobianos são um importante problema de saúde pública, pois causam infecções de difícil tratamento que resultam em maiores períodos de internação, aumento das taxas de mortalidade e dos custos da assistência à saúde. Entre as estratégias para a prevenção e controle deste problema, a detecção de bactérias resistentes no ambiente tem ganhado importância, e neste contexto, o ambiente aquático tem recebido atenção por ser um importante reservatório de genes de resistência, destacando-se os genes que codificam as -lactamases de espectro estendido (ESBLs) e de resistência às quinolonas. A produção de ESBLs é uma ameaça à terapia antimicrobiana, pois estas enzimas inativam as cefalosporinas de terceira geração, que constituem a principal opção para o tratamento de infecções graves por bactérias Gramnegativas. A resistência às quinolonas também é um problema porque estes antimicrobianos são alternativas para o tratamento de infecções por bactérias Gram-negativas produtoras de ESBLs. Este estudo teve como objetivos investigar no Sistema Municipal de Abastecimento de São José do Rio Preto-SP, a presença de coliformes resistentes às cefalosporinas de terceira geração e às quinolonas, e investigar nos isolados a presença de genes determinantes da produção de ESBLs do tipo TEM, SHV e CTX-M, e de resistência às quinolonas (qnrA, qnrB e qnrS). O total de 7899 amostras de água foi coletado entre julho a novembro de 2011. Estas foram submetidas à filtração em membrana utilizando o Ágar Endo para o isolamento bacteriano. Os testes de suscetibilidade aos antimicrobianos foram realizados de acordo com o CLSI e em adição foi realizado teste fenotípico para produção de ESBL. PCR com primers... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Bacteria resistant to antimicrobial cause infections which require longer periods of hospitalization, increase the mortality rates and also the expenses with health care. Among the strategies for the prevention and control of this problem, the detection of resistant bacteria in the environment has been more important and, in this context, the aquatic environment has been paid attention for being an important reservoir of resistance gene, especially the genes encoding the extended-spectrum β-lactamases (ESBLs) and quinolone resistance. The production of ESBLs is a threat to antimicrobial therapy because these enzymes inactivate third generation cephalosporins, which are the primary choice for treatment of severe infections caused by Gram-negative bacteria. The quinolone resistance is also a problem because they are alternatives for antimicrobial treatment of infections caused by Gram-negative bacteria producing ESBLs. This study aimed to investigate in Municipal System of Supply in São José do Rio Preto-SP, the presence of coliform bacteria resistant to third generation cephalosporins and to quinolones and also investigate in isolated bacteria the presence of determinant genes for ESBLs production (TEM, SHV and CTX-M) and of quinolones resistance (qnrA, qnrB and qnrS). All the 7899 water samples were collected from July to November 2011. They were subjected to membrane filtration using Endo Agar for bacterial isolation. The antimicrobial susceptibility testings were carried out according to CLSI and in addition was performed phenotypic test for ESBL production. PCR with specific primers were performed in order to detect genes blaSHV, blaTEM, blaCTX-M, qnrA, qnrB e qnrS. None of the 72 isolated coliforms presented this phenotypic test positive for ESBL production, but 22 isolated coliforms presented resistance to... (Complete abstract click electronic access below) / Mestre
22

Validação do algoritmo do programa netuno para avaliação do potencial de economia de água potável e dimensionamento de reservatórios de sistemas de aproveitamento de água pluvial em edificações

Rocha, Vinicius Luis 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T14:39:40Z (GMT). No. of bitstreams: 1 269220.pdf: 2196133 bytes, checksum: 93925260e165a3bb74448b2bcc1fa405 (MD5) / O aproveitamento de água pluvial para fins não potáveis em edificações é uma medida que proporciona a redução da demanda de água potável e a minimização de problemas relacionados à disponibilidade dos recursos hídricos. A eficiência dos sistemas de aproveitamento de água pluvial é afetada sobretudo pelo dimensionamento do reservatório de armazenamento. O dimensionamento adequado é essencial para evitar a operação do reservatório de forma ociosa quando superdimensionado ou insuficiente, quando subdimensionado. O objetivo principal deste trabalho é validar o algoritmo do programa computacional Netuno, utilizado para avaliar o potencial de economia de água potável e o dimensionamento de reservatórios para aproveitamento de água pluvial em edificações. Dados reais de consumo de água potável e pluvial, precipitação pluviométrica e da variação do nível de água no reservatório, foram obtidos junto a uma residência experimental localizada em Florianópolis. O monitoramento do sistema de aproveitamento de água pluvial da edificação ocorreu em quatro períodos distintos, totalizando 196 dias. Devido à ocupação variável da residência e, também, ao baixo consumo de água verificado em testes preliminares, foi necessário intervir na demanda de água pluvial, simulando a permanência constante de quatro moradores. Como referência para o cálculo da demanda diária de água pluvial, considerou-se uma demanda de água potável de 150 litros per capita por dia, e um percentual variando de 40 a 150% desta demanda conforme o período monitorado. Diariamente, descartou-se o volume correspondente à demanda de água pluvial através de um ponto de consumo dessa água. Uma versão modificada do algoritmo do programa Netuno foi proposta, onde a principal diferença em relação à versão original é a consideração do consumo de água pluvial antes da chuva. O estudo foi baseado em simulações computacionais para estimar o potencial de economia de água potável com os dados levantados em campo, considerando diferentes intervalos de tempo e as características físicas do sistema. Os resultados das simulações foram comparados à economia de água potável obtida através da utilização de água pluvial, para fins não potáveis, na residência estudada. As demandas médias de água pluvial efetivamente descartadas foram de 279, 293, 607 e 624 litros/dia, respectivamente, do primeiro ao quarto período monitorado. Os resultados do trabalho mostram potenciais de economia de água potável estimados pelo Netuno idênticos às economias obtidas na residência quando se dispõe de água em quantidade suficiente nos reservatórios, para atendimento integral da demanda de água pluvial. Por outro lado, quando não há água pluvial em quantidade suficiente para suprir a demanda, observam-se diferenças absolutas entre os potenciais estimados e as economias efetivas variando de 0,2 a 6,7%, para economias de água potável de 48,7 a 76,2%. A principal conclusão do trabalho é que o algoritmo do programa Netuno prediz adequadamente o potencial de economia de água potável obtido através do aproveitamento de água pluvial em edificações. / Rainwater use for non-potable purposes in buildings is a measure that provides the reduction of potable water demand and the minimization of problems related to availability of water resources. The efficiency of rainwater harvesting systems is affected mostly by the sizing of the storage cistern. The appropriate sizing is essential to avoid the superfluous room in the cistern when it is oversized; or insufficient room when it is undersized. The main objective of this research is to validate the algorithm of the Neptune computer programme, used to evaluate the potential for potable water savings and the sizing of cisterns for rainwater storage in buildings. Actual potable water and rainwater consumption, rainfall and variation of the water level in the cistern were obtained from an experimental house in Florianópolis. The monitoring of the rainwater harvesting system occurred in four different periods, totalling 196 days. Due to the variation of the house occupation, and also to the low water consumption verified in preliminary tests, it was necessary to increase the demand of rainwater, simulating the constant occupation of four residents. The daily demand of rainwater was taken as a percentage of the potable water demand, which was 150 litres per capita a day. Such a percentage was varied from 40 to 150% of the potable water demand, according to the monitored period. The volume corresponding to the rainwater demand was discarded daily. A modified version of the algorithm of Neptune was proposed, where the main difference in relation to the original version is the consideration of rainwater consumption before the rainfall. The study was based on computer simulations to evaluate the potential for potable water savings considering all data collected on site, considering different time intervals and the physical characteristics of the system. The results of the simulations were compared to the potable water savings obtained by using rainwater for non-potable purposes in the studied house. The average rainwater demands that were discarded were 279, 293, 607 and 624 litres a day, respectively, from the first to the fourth monitored period. The results of the study showed that the potential for potable water savings estimated by Neptune were identical to savings obtained in the house when there was enough rainwater in the cistern to fulfil the demand for rainwater. On the other hand, when there was not enough rainwater to supply the rainwater demand, absolute differences between Neptune results and the effective savings varied from 0.2 to 6.7%, for potable water savings ranging from 48.7 to 76.2%. The main conclusion obtained from the research is that the algorithm of the Neptune computer programme correctly predicts the potential for potable water savings by using rainwater in buildings.
23

Vulnerabilidade e perigo de contaminação dos aquíferos nas sub-bacias do Alto Aguapeí e Alto Peixe - SP

Montero, Rafael Carrion [UNESP] 14 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-14Bitstream added on 2014-06-13T19:13:18Z : No. of bitstreams: 1 montero_rc_me_bauru.pdf: 2401420 bytes, checksum: edf8873c33a227bcb3f0d5bb72554719 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A crescente demanda por recursos subterrâneos nas Bacias Hidrográficas dos Rios Aguapaí e Peixe, localizadas no oeste do Estado de São Paulo e a presença cada vez maior de substâncias em condições de acesso e contaminação das águas em subsuperfície têm pressionado de forma negativa a disponibilidade hídrica nessas bacias. Neste contexto de degradação, esta Dissertação objetiva a caracterização e avaliação da vulnerabilidade natural e dos perigos de contanimação das unidades aquíferas aflorantes nas subunidades de gestão de recursos hídricos denominados Alto Aguapeí e Alto Peixe. A caracterização da Vulnerabilidade foi realizada com aplicação do método GOD (Foster & Hirata, 1988). O perigo de contaminação dos aquíferos foi avaliado mediante a interpolação da vulnerabilidade natural com as fontes potencias de contaminação, identificadas e classificadas quanto o seu potencial de gerar carga contaminante, a partir da aplicação do método POSH (FOSTER et al, 2006). Os procedimentos de geoprocessamento foram realizados com auxílio do SIG ArcMap TM 9.3. Os resultados demonstraram que vulnerabilidades de classificação Extrema estão restritas as planícies fluviais dos rios Aguapeí e Tibiriça, ocupando cerca de 2% da área de estudos, as classes de vulnerabilidade Alta e Alta Baixa ocupam 41,5% e 23,7% respectivamente, enquanto 28,4% da área correspondem à vulnerabilidade Média. Para o restante da área obteve-se a classificação Média e Média Baixa Vulnerabilidade. A correlação das vulnerabilidades com as fontes potenciais de contaminação demonstraram que independente da localização, os postos de combustível e os locais de disposição de resíduos sólidos apresentam Alto perigo de contaminação. As atividades da indústria, por sua vez, apresentam Alto perigo de contaminação para os distritos... / The increasing demand for groundwater resources in the Watersheds of Aguapeí and Peixe Rivers, located in the western part of São Paulo province, and also the increasing presence of substances in access condition and water contamination in the subsurface have been pressuring negatively the water availability in both basins. In this degradation context, this dissertation aims to characterize and evaluate the natural vulnerability and contamination risks of aquifers outcropping units in the sub water resources management units called. Alto Aguapeí and Alto Peixe. The vulnerability characterization was made applying the GOD method (Foster & Hirata, 1988). The aquifers contamination risk was estimated by interpolation of the natural vulnerability and the potential contamination sources that was identified and classified by their potential to generate contaminant load, using the POSH method (Foster et al, 2006). The geoprocessing producers were performed with assisting of some tools from the GLS ArcMap TM 9.3. The results evidenced that extreme classification vulnerability are restricted just for river plaints of Aguapeí and Tibiriça rivers, occupying around 2% of the studied area. The High and High Low vulnerability classes occupy 41.5% and 23.7% respectively and average vulnerability 28.4%. For the rest of the area was obtained medium and low vulnerability classification. The correlation of vulnerabilities and potential sources of contamination demonstrated that regardless of location, gas stations and solid waste disposal spots have high risks of contamination. The industrial activities have a high risk of contamination due the industrial district of Garça and Marilia and moderate for units in the food sector, located outside these districts. Furthermore, it is evident the importance of introducing the territory management policies... (Complete abstract click electronic access below)
24

Pesticidas mais empregados na cultura de soja no município de Dourados (MS) : determinação em água para consumo humano /

Lopes, Mara Nilza Teodoro. January 2006 (has links)
Orientador: Maria Lucia Ribeiro / Banca: Luciana Polese / Banca: Mary Rosa Rodrigues de Marchi / Banca: Maria Eugênia Queiroz Nassur / Banca: Eny Maria Vieira / Resumo: O uso intensivo de pesticidas em lavouras e pastagens, visando o aumento da produção agropecuária pode gerar resíduo. O destino final destes resíduos é sempre a água, seja por escoamento superficial, subsuperficial ou profundo. Este trabalho teve como objetivo avaliar a contaminação de água por pesticidas usados nas culturas de soja e milho na região da cidade de Dourados/MS. Para tanto, métodos de análise foram otimizados para a determinação de resíduos de ácido 2,4-diclorofenoxiacético (2,4-D) e do seu metabólito 2,4-diclorofenol (2,4-DCF) por cromatografia líquida de alta eficiência/detector espectrofotométrico (CLAE/UV); de atrazina e de seus metabólitos deisopropilatrazina (DIA), desetilatrazina (DEA) e de trifluralina e de parationa metílica por cromatografia gasosa/detector termiônico específico (CG/DTE) em amostras de água. Os critérios para a seleção destes pesticidas foram a freqüência elevada de uso e o risco potencial de contaminação do ambiente aquático. Os procedimentos experimentais envolveram préconcentração em cartucho de octadecilsilano (C18) e eluição com metanol para os analitos estudados por CLAE/UV e com a mistura acetato de etila:diclorometano (1:1, v/v) para os estudados por CG/DTE. A escolha dos sistemas de solventes foi avaliada com relação ao volume, velocidade de eluição e tempo de secagem do cartucho. O estudo de estabilidade dos pesticidas em cartucho C18 demonstrou ser viável sob temperatura de -20ºC por até 21 dias. A recuperação foi realizada em dois níveis de fortificação: para 2,4-D e 2,4-DCF (10 e 30 æg L-1), atrazina, DIA, DEA e parationa metílica (1 e 2 æg L-1) e trifluralina (10 e 20 æg L-1); Valores médios de recuperação acima de 76% foram obtidos para todos os pesticidas com valores de coeficientes de variação entre 2,1 e 8,2%, com exceção do metabólito DIA, cuja recuperação média foi de 46%. / Abstract: The region of the city of Dourados/MS is an area with a high agricultural production. As consequence of the conditions under which soybean and maize are grown, they are susceptible to pest attack. Therefore, pesticides are extensively used to control pests. However, after their application, pesticide residues may translocate to water bodies. This fact constitutes a health risk because of their toxicity. So, the objective of this work was study the pesticides more intensely used in the soybean and maize crops. For that, analytical methods were optimized to determine 2,4-dichlorophenoxyacetic acid (2,4-D) and its metabolite 2,4-dichlorophenol (2,4-DCF) by high-performance liquid chromatography/UV detector (HPLC/UV); atrazine and their metabolites deisopropylatrazine (DIA), deethylatrazine (DEA), trifluralin, and parathion methyl by gas chromatography/thermionic specific detector (GC/TSD) in water samples. These pesticides were selected because they are the most frequently used in this agricultural area and also due to the contamination potential with relation to the aquatic environment. The procedures involved solid-phase extraction using silica-based cartridge (C18) with methanol for elution of the pesticides studied by HPLC/UV and ethyl acetate:dichloromethane (1:1, v/v) for one studied by GC/TSD. The methods were validated with fortified samples at two concentration levels: for 2,4-D and 2,4-DCF at 30 and 10 æg L-1 for atrazine, DIA, DEA and parathion methyl at 1 and 2 æg L-1 and for trifluralin at 10 and 20 æg L-1. For most of the pesticides the average recoveries were >76% with relative standard deviation less than were bellow 2,1 and 8,2%. However, the recoveries observed for DIA in water were 4%. The stability study of these pesticides demonstrated recovery for all compounds after storage in disposable C18 cartridges at -20°C for 21 days. / Doutor

Page generated in 0.0511 seconds