Evaluation de la contamination des atmosphères intérieures et extérieures induite par les usages non agricoles de pesticides

Raeppel, Caroline 16 November 2012 (has links) (PDF)
Dans le but d'évaluer la contamination des atmosphères intérieures et extérieures induite par les usages non agricoles de pesticides, deux approches complémentaires ont été mises en oeuvre : l'utilisation de capteurs passifs de type Tenax TA pour réaliser des prélèvements d'air, et l'utilisation de cheveux employés comme biomarqueurs d'exposition. Des campagnes de mesures ont été menées sur plusieurs sites à la suite de traitements de désherbage ou de désinsectisation ainsi quedans des logements. Les échantillons d'air et de cheveux ont été extraits respectivement par thermodésorption et par extraction solide-liquide, avant d'être analysés en chromatographie gazeuse couplée à la spectrométrie de masse (GC-MS). Une augmentation du niveau de contamination de l'air extérieur et intérieur et l'existence de transferts entre ces deux milieux ont pu être observées après l'application de pesticides. Dans les logements, des pesticides actuellement employés mais aussi des pesticides interdits et persistants ont été détectés. Plusieurs pesticides ont également été détectés dans les cheveux, mais l'exposition humaine à ces derniers n'a pas pu toujours être corrélée à une contamination de l'air.
22

Transfert d'un composé organo-chloré depuis une zone source localisée en zone non saturée d'un aquifère poreux vers l'interface sol-air : expérimentations et modélisations associées

Marzougui, Salsabil 29 January 2013 (has links) (PDF)
Deux expériences ont été menées sur la plate-forme expérimentale "SCERES" afin d'évaluer les concentrations et les flux de vapeurs de TCE dans SCERES en présence de deux dalles de béton fissurées installées, l'une après l'autre, à la surface de SCERES. Cet aquifère poreux est un milieu hétérogène de grande échelle (25 x 12 x 3 m3). Les résultats ont montré que le panache de vapeur de TCE couvre la plupart du bassin au bout de 3 semaines depuis la création de la zone source de TCE dans le sous sol. L'hétérogénéité du site SCERES a engendrée une distribution verticale non uniforme de la concentration de vapeurs de TCE. La simulation du panache de vapeur dans SCERES a été effectuée au moyen du code de calcul multiphasique "SIMUSCOPP". La présence sur SCERES de la dalle de béton, un milieu peu perméable et peu diffusif, a constitué une "barrière" en vue du transfert de vapeurs de TCE vers l'interface dalle/atmosphère. Afin de mieux quantifier le flux de vapeurs à travers la dalle de béton, une étude de coefficient de diffusion et de perméabilité des deux dalles a été réalisée. Un mouvement vertical ascendant du toit de la nappe a généré un fort gradient de pression motrice de l'air du sol. Ceci a engendré une forte augmentation des flux de vapeurs à l'interface sol/atmosphère. La quantification de ces flux de vapeurs a été effectuée à l'aide d'une solution semi analytique basée sur la loi de Fick et la loi de Darcy en tenant compte à la fois de l'effet de gradient de pression motrice et l'effet de densité de vapeurs sur le transfert de vapeurs vers la surface du sol. L'intrusion de vapeurs de TCE dans le bâtiment modèle, installé sur la dalle de béton, a été générée par une mise en dépression dans ce dernier. Ce qui a fait augmenter la concentration de vapeurs de TCE sous la dalle ainsi dans le bâtiment. La simulation de l'intrusion de vapeurs dans l'air intérieur de bâtiment a été réalisée par l'intermédiaire du code de calcul multiphysics "COMSOL", avec lequel nous avons démontré l'évolution de la concentration de vapeurs obtenues expérimentalement dans le bâtiment et qui dépend directement de la variation spatio-temporelle du flux massique à travers la dalle.
23

Transfert d'un composé organo-chloré depuis une zone source localisée en zone non saturée d'un aquifère poreux vers l'interface sol-air : expérimentations et modélisations associées / Transfer of an organo-chlorinated compound from a source area located in the unsaturated zone of a porous aquifer to the soil-air interface : experiments and modelling related

Marzougui Jaafar, Salsabil 29 January 2013 (has links)
Deux expériences ont été menées sur la plate-forme expérimentale "SCERES" afin d'évaluer les concentrations et les flux de vapeurs de TCE dans SCERES en présence de deux dalles de béton fissurées installées, l'une après l'autre, à la surface de SCERES. Cet aquifère poreux est un milieu hétérogène de grande échelle (25 x 12 x 3 m3). Les résultats ont montré que le panache de vapeur de TCE couvre la plupart du bassin au bout de 3 semaines depuis la création de la zone source de TCE dans le sous sol. L'hétérogénéité du site SCERES a engendrée une distribution verticale non uniforme de la concentration de vapeurs de TCE. La simulation du panache de vapeur dans SCERES a été effectuée au moyen du code de calcul multiphasique "SIMUSCOPP". La présence sur SCERES de la dalle de béton, un milieu peu perméable et peu diffusif, a constitué une "barrière" en vue du transfert de vapeurs de TCE vers l'interface dalle/atmosphère. Afin de mieux quantifier le flux de vapeurs à travers la dalle de béton, une étude de coefficient de diffusion et de perméabilité des deux dalles a été réalisée. Un mouvement vertical ascendant du toit de la nappe a généré un fort gradient de pression motrice de l'air du sol. Ceci a engendré une forte augmentation des flux de vapeurs à l'interface sol/atmosphère. La quantification de ces flux de vapeurs a été effectuée à l'aide d'une solution semi analytique basée sur la loi de Fick et la loi de Darcy en tenant compte à la fois de l'effet de gradient de pression motrice et l'effet de densité de vapeurs sur le transfert de vapeurs vers la surface du sol. L'intrusion de vapeurs de TCE dans le bâtiment modèle, installé sur la dalle de béton, a été générée par une mise en dépression dans ce dernier. Ce qui a fait augmenter la concentration de vapeurs de TCE sous la dalle ainsi dans le bâtiment. La simulation de l'intrusion de vapeurs dans l'air intérieur de bâtiment a été réalisée par l'intermédiaire du code de calcul multiphysics "COMSOL", avec lequel nous avons démontré l'évolution de la concentration de vapeurs obtenues expérimentalement dans le bâtiment et qui dépend directement de la variation spatio-temporelle du flux massique à travers la dalle. / Two experiments were conducted on the experimental platform "SCERES" to assess the TCE vapour concentrations and fluxes in SCERES with two concrete slabs installed, one after the other, on the ground surface. This artificial aquifer is a large scale (25 x 12 x 3 m3) heterogeneous porous medium. The results showed that the TCE vapour plume covers most of the basin 3 weeks after the creation of the TCE source area in unsaturated zone. The heterogeneity of SCERES has generated a non uniform vertical distribution of the TCE vapour concentration. Simulation of vapour plume in SCERES was carried out by the multiphase code "SIMUSCOPP".The presence in SCERES of a low permeability and low diffusive medium compared to the sand in the basin,as a concrete slab, constituted a "barrier" for the transfer of TCE vapour to the interface concrete slab / atmosphere. To better quantify the TOE fluxes through the concrete slab, a study of diffusion coefficient and permeability of both concrete slabs was done. An upward vertical movement of the water table has generated a strong soil air pressure driving gradient, which led to a strong increase in the TCE vapour concentrations near the surface which has increased the vapour fluxes at the interface soil / atmosphere. Quantification of vapour fluxes at the interfaces soil / atmosphere and concrete slab / atmosphere was performed using a semi analytical approach based onFick's and Darcy's laws by taking into account both the effect of the driving pressure gradient and the effect of density vapour on the vapour transfer towards the soil surface.The intrusion of TCE vapours into the model building installed on the concrete slab was generated by creating a vacuum. The results showed that, during the TCE vapour suction from the model building, the concentration of TCE vapours under the concrete slab and in the building increases. Simulation of vapour intrusion into indoor air was done by the computational Multiphysics code "COMSOL", allowing simulation of the evolution of the vapour concentration obtained experimentally in the building. Il was shown that they depend directly on the spatial-temporal variation of the mass flux through the slab.
24

Déterminants et prévision des fluctuations de la concentration en polluants dans un environnement intérieur / Sources of fluctuations and forecast of pollutant concentrations in an indoor environment

Ouaret, Rachid 19 July 2016 (has links)
Les caractéristiques des fluctuations des concentrations de polluants dans un environnement intérieur normalement occupé dépendent fortement de plusieurs paramètres, en particulier des occupants et de leurs activités et comportement, qui altèrent de manière considérable la nature statistique de leur variabilité temporelle. Ces fluctuations sont rarement disponibles et décrites dans la littérature. La mise à disposition de mesures en continu de la concentration en formaldéhyde et en particules (de 0,35 à 20 µm de diamètre) dans l’air d’un environnement de bureau et d’une maison expérimentale sur plusieurs mois avec un pas de temps fin (entre 1 min et 1 heure) a permis d’engager une réflexion sur la nature de ces fluctuations et leur prévisibilité. L’objectif de la thèse se décline en trois axes de recherche : (i) la caractérisation des fluctuations des concentrations des polluants cible ; (ii) la mise en évidence des sources de variabilité de ces fluctuations et (iii) la prévision des concentrations de ces polluants. Le premier axe concerne la détermination des caractéristiques communes partagées par les différents polluants. Le deuxième axe porte, à l'aide des approches par séparation aveugle des sources, sur l'estimation des déterminants des sources de variabilité. Le troisième axe est consacré à la prévision des fluctuations de concentration des polluants. L'analyse des séries temporelles pour ce type de données (hautes fréquences) doit prendre en compte l’échelle de temps sur laquelle évoluent plusieurs microstructures. Plusieurs outils ont été employés : l'analyse spectrale (dépendance à long terme par la mesure fractale et la statistique R/S), la mesure de l’oméga-prédictibilité, ainsi que la décomposition des séries en composantes latentes par STL (seasonal trend decomposition using Loess), SSA (singular spectrum analysis) et SBD (spectral band decomposition).L'identification des sources de variabilité de particules a été abordée par les méthodes de séparation aveugle des sources basées sur une factorisation matricielle en profils et contributions, sous contrainte statistique d'indépendance (ACI) ou de non-négativité (NNMF ou PMF). Les factorisations ont été appliquées à la matrice constituée des séries temporelles de différentes gammes de taille des particules. Certains profils ou contributions des sources ont pu été interprétés grâce aux variables exogènes "traceurs" de certaines sources (comme le CO2 indicateur de la présence de la source occupants).Concernant la prévision des concentrations de polluants, le choix des modèles a été basé sur la structure de la série temporelle, mise en évidence lors de l’étape de caractérisation. On constate de meilleures performances de prévisions sur la série ayant subi un prétraitement statistique de décomposition STL, SSA ou SBD. Plusieurs types de modèles stochastiques (linéaires ou non linéaires) ont été appliqués ensuite à ces composantes et le résultat final de la prévision est donné par leur combinaison. La caractéristique de non-linéarité qui apparaît sous forme de changements abrupts de concentration causée en grande partie par la manipulation des ouvrants et qui se greffe sur l'évolution régulière du système dynamique mérite un traitement spécial. Un nouveau type de modèles de prévision a été développé pour répondre aux exigences de la nature des données hautes fréquences présentant ce type de non linéarité. Ce modèle associe une étape de décomposition des séries en bandes spectrales (SBD) couplée avec une étape de modélisation par des modèles autorégressifs à seuil (TAR) ou par la dynamique du chaos : FFT-(TAR/Chaos).Les résultats montrent que le prétraitement par décomposition en bandes spectrales ou STL améliore sensiblement la prévision des concentrations de formaldéhyde et des particules fines jusqu’à un horizon de 10 heures pour le formaldéhyde (pas de temps 1 minute) et de 1 à 4 jours pour les particules selon leur taille (pas de temps horaire) / The time fluctuation features of particulate concentrations in a real occupied indoor environment are strongly dependent of several parameters and in particular the occupation and occupants’ activities and behaviors. These parameters considerably alter the statistical variability of the time series dynamics. These fluctuations are rarely available and described in the literature. These types of fluctuations are rarely available and described in the literature. The availability of continuous measurements of concentrations of formaldehyde and particulate matter (from 0.35 to 20 µm of diameter) in an indoor environment (office and a test house) during several months with a fine time resolution (from 1 min to 1 hour) permitted to initiate a process of reflection on the nature of these fluctuations and their predictability. The aim of the thesis follows three main axis of research: (i) characterizing indoor environment pollutant concentrations variability; (ii) revealing the sources of variability of these fluctuations and (iii) forecasting the pollutant concentrations in a real indoor environment. The first axis concerns the determination of the common features shared by the different pollutants. The second axis focuses on the sources variability estimating using a Blind Source Separation (BSS) approach. Lastly, the third axis focuses on the forecasting of pollutant concentrations. The time series analysis for this type of data (high frequency) should take into account the time scale on which microstructures evolve. Several tools were employed, such as the spectral analysis (long-range dependency by fractal dimension measures and R/S statistic), the omega-predictability, as well as the time series decomposition into latent components by STL (Seasonal Trend Decomposition using Loess), SSA (Singular Spectrum Analysis) and SBD (Spectral Band Decomposition).The identification of the sources of particles concentrations is developed using BSS based methods which are based on a matrix factorization as profiles and contributions under a statistical independence constraint (ICA) or a non-negativity constraint (NNMF or PMF). The factorizations were applied to the matrix of the time series of different particle size bins. Some profiles or source contributions could be interpreted using exogenous variables as fingerprints of some sources (such as CO2 concentrations used as indicator of the “occupation”).Concerning the pollutant concentrations forecasting, the model selection was made in agreement with the time series structures, highlighted in the characterization stage. One can notice better performances forecasts when using the series having been preprocessed by decomposition: STL, SSA or decomposition in spectral bands (based Transform Fourier), SBD. Several types of stochastic models (linear or nonlinear) were then applied to these components and the final forecast result is given by their combination. A special type of nonlinearities involving a special treatment is the abrupt concentration changes in time series concentrations due mainly to windows manipulation and graft on the regular evolution of the dynamic system. A new type of forecast models has been developed in adequacy with the requirements of the nature of high-frequency data. This model combine spectral band decomposition step (SBD) coupled with a modeling stage based on autoregressive switching threshold model (TAR) or chaos dynamic: FFT- (TAR / Chaos).The results show that the pretreatment by spectral band decomposition or STL improves significantly formaldehyde and fine particles concentrations forecast on 10-hour horizon for formaldehyde (sampled every minute) and on a horizon of 1 to 4 days for the particles (sampled every hour), depending on their size bins
25

Textile lumineux en fibres optiques pour une application photocatalytique en phase gazeuse / Lighted textile with optical fibres for a photocatalytic application in gas phase

Bourgeois, Pierre-Alexandre 25 March 2011 (has links)
La pollution de l'air intérieur est un enjeu majeur pour la santé humaine. Pour réduire les concentrations de polluants des milieux confinés, notre étude s'est basée sur la conception et les tests d'un nouveau média photocatalytique innovant composé de textile rendu lumineux grâce à la présence de fibres optiques microstructurées. Le textile est rendu photocatalytique après ajout de TiO2 en suivant différentes méthodes de dépôt. Les fibres optiques ont alors deux rôles fondamentaux : premièrement d'être le support du catalyseur et deuxièmement d'être le moyen d'amener le rayonnement UVA au coeur du lit photocatalytique. La rencontre des trois constituants de la photocatalyse, les photons UV, le catalyseur et le polluant, est alors favorisée par l'utilisation de ce type d'échantillon. Les propriétés structurales et optiques de ce nouveau matériau ont été caractérisées par des analyses de surface (microscopie otique et microscopie électronique à balayage environnementale (MEBE)), des mesures d'irradiance UV et des analyses permettant de localiser le TiO2 à la surface de l'échantillon (Raman et MEB‐EDX). L'influence de différents paramètres tels que la structure textile, la méthode de dépôt, les caractéristiques d'irradiation, les débits molaires sur la dégradation de deux composés organiques volatiles, le formaldéhyde et le toluène, a été étudiée et corrélée aux propriétés physicochimiques du matériau / The indoor air pollution is a major challenge for human health. To reduce the concentrations of pollutants in confined area, our study is based on the design and testing of a new innovative photocatalytic media composed of textile which is lighted with microstructured optical fibres. The textile becomes photocatalytic after the coating of TiO2 with different methods. The optical fibers have then two fundamental roles: first to be the catalyst support and secondly to be the light transmission support from the source into the photocatalytic bed. The meeting of the three constituents of photocatalysis (UV photons, catalyst and pollutants) is then enhanced by the use of this type of sample. The structural and optical properties of this new material were characterized by surface analysis (optical microscopy and electronic secondary electron microscopy (ESEM)), with measurements of UV irradiance and methods to determinate the location of the TiO2 on the sample surface (Raman spectroscopy and EDX‐SEM). The influence of different parameters such as textile structure, coating method, irradiation characteristics, molar flow on the degradation of two volatile organic compounds, formaldehyde and toluene, was studied and correlated to the physical‐chemical properties of the material
26

Exposition aux composés organiques semi-volatils reprotoxiques et neurotoxiques dans l'habitat / Exposure to semi-volatile organic compounds in French dwellings

Blanchard, Olivier 18 December 2014 (has links)
Les composés organiques semi-volatils (COSVs) regroupent un grand nombre de composés chimiques utilisés notamment comme substances actives ou additifs dans les matériaux de construction, de décoration et dans de nombreux produits de consommation. Les COSVs sont omniprésents dans les environnements intérieurs et fréquemment détectés dans les poussières sédimentées et dans le compartiment aérien. Cette thèse a permis de documenter les concentrations de 57 composés dans 30 logements français et d'utiliser ces mesures pour tester un modèle d'équilibre visant à prédire leur répartition dans les différents compartiments de l'environnement intérieur. De ce travail, il ressort une forte ubiquité des COSVs dans les logements étudiés. Les concentrations les plus élevées ont été observées pour les phtalates et dans une moindre mesure pour le bisphénol A, les muscs synthétiques et certains pesticides et HAPs. Ces résultats confirment l'intérêt de mieux caractériser l'exposition de la population générale aux COSVs dans l'habitat français. Les travaux portant sur le modèle d'équilibre ont montré que le coefficient de partage entre l'air et l'octanol (Koa) peut être un bon prédicteur pour estimer la concentration d'un composé donné dans un ensemble de logements. Cependant, certaines limites ont été identifiées et une meilleure caractérisation des paramètres utilisés est recommandée. / Semivolatile organic compounds (SVOCs) include a large number of chemicals compounds used as active substances or additives in building materials and in many consumer products. SVOCs are ubiquitous in indoor environments and frequently detected in settled dust and indoor air. This work has investigated indoor concentrations of 57 target compounds in 30 French dwellings and measurements were used to test an equilibrium model to predict their partitioning in indoor compartments. The results showed a strong ubiquity of SVOCs in French dwellings. The highest concentrations were measured for phthalates and to a lesser extent for bisphenol A, synthetic musks, some pesticides and PAHs. These results confirm the interest to assess human exposure to SVOCs in the French dwellings. The work on the predictive model showed that octanol/air partitioning coefficient (Koa) is a good predictor to estimate SVOC concentrations in a large number of buildings. However, some limits were identified and a better estimation of the parameters used in these models is required.
27

Elaboration d’un microsystème d’analyse de l’air destiné à la détection rapide d’un développement fongique dans les espaces clos / Elaboration of a rapid and continuous air analyzing macrosystem for fungal contamination detection in enclosed spaces

Joblin, Yaël 12 May 2011 (has links)
Les champignons sont des biocontaminants courants des environnements intérieurs. De nombreuses études ont démontré leur rôle dans la dégradation des supports que ces microorganismes colonisent tels que les matériaux de construction, les ouvrages ou les œuvres d'art. De plus, ces biocontaminants sont susceptibles d'induire des allergies, des infections, des toxi-infections ou encore des irritations. Depuis 2005, une technique de détection de la croissance fongique, basée sur la recherche de traceurs chimiques spécifiques dans l'air, et un indice de contamination fongique (ICF), ont été développés et validés au cours de différentes campagnes de mesures dans l'habitat, les bureaux, les écoles, les crèches… L'objectivation d'une croissance fongique dans un environnement s'appuie sur des prélèvements par adsorption, une analyse chromatographique au laboratoire (GC/MS) et le calcul de l'ICF. Dans le cadre de la surveillance de la qualité microbiologique de l'air des environnements intérieurs, cette thèse a pour ambition de prolonger ces travaux en développant notamment un système de microcapteurs chimiques adapté à la mesure in situ. Cette recherche repose à la fois sur la méthode de détection fongique développée au CSTB et sur l'expertise scientifique et technique de l'ESIEE en matière de miniaturisation d'instruments de mesure, grâce à l'apport des microtechnologies. Le premier axe de cette étude a consisté à identifier expérimentalement les COV du métabolisme fongique spécifiques d'un développement sur des matériaux du patrimoine. Ces molécules ont permis de consolider l'ICF et de définir deux indices spécifiques à la problématique des sites patrimoniaux, validés dans des châteaux, musées, bibliothèques, grottes ornées… Le second axe porte, d'une part, sur la conception la réalisation et la caractérisation des briques élémentaires du microsystème d'analyse, à savoir un module de préconcentration (adsorption TENAX), un module de séparation (microGC) et un module de détection (capteurs polymères) et d'autre part sur les intégrations et pilotage de ces briques / Fungi are common microbial contaminants of indoor environments. Many studies have demonstrated their role in the partial or total degradation of materials they colonize such as building materials, or works of art. Moreover, those microbial contaminants are likely to lead to allergies, infections, poisoning or irritation. Since 2005, a new technique based on researching specific chemical tracers in the air, was developed and validated during different measurement campaigns. This approach is now applied to various indoor environments (houses, offices, schools, child care centers…) and allows the detection of recent and/or hidden contamination. The purpose of this work is to study and characterize a rapid and continuous air analysing microsystem for detection of fungal contamination in closed spaces. This study falls within the field of monitoring air microbiological quality in indoor environments. In addition to the time saved by the absence of any laboratory analysis, this system must provide a permanent monitoring of environments frequented by people, such as museums, schools, hospitals... This research is based both on the fungal detection method developed by CSTB and on scientific and technical expertise of ESIEE : specialised in design and manufacturing of miniaturized analysis systems obtained using microtechnology. The first step of this study was to define the compounds' nature to be detected for different cases of contamination along with the sampling strategy for the system. The second step focuses on the microstructures design and fabrication to be used in microanalytical system based on gas chromatography and the development of a miniaturised analysis system. So the first part of the study consisted in defining specific fungal contamination tracers for heritage conservation sites. This list allowed to reinforce a fungal contamination index for indoor environments and to define two specific indexes designed for heritage conservation sites. The validation of these different indexes allowed checking their compliance with those types of environments (castles, museums, libraries, decorated caves...) by detecting all cases of contamination, along with the control remediation of former contaminated environments. The second part of the study enabled the design and validation of three main modules constitutive of the microanalytical system based on gas chromatography. A miniaturised analysis system based on three modules has been developed
28

Impact des systèmes de gestion des lisiers sur la contamination en microorganismes des porcheries et des producteurs de porcs

Létourneau, Valérie. 17 April 2018 (has links)
Les porcheries de l'est du Canada gèrent les lisiers à l'aide de systèmes conventionnels, de systèmes de litières et de systèmes de séparation à la source. Nous avons évalué l'impact de ces différents systèmes de production sur la présence de bactéries, d'actinomycètes, de moisissures, de bactéries et de parasites pathogènes zoonotiques et de gènes de résistance à la tetracycline et à la vancomycine dans les lisiers et dans les bioaérosols. L'impact de l'exposition des producteurs de porcs aux bioaérosols des porcheries a de même été investiguée par la recherche de bactéries pathogènes zoonotiques et de gènes de résistance à la tetracycline et à la vancomycine dans la flore nasopharyngée. La présence de litières dans les porcheries n'influe pas sur les concentrations en bactéries et en parasites pathogènes zoonotiques des déjections. Le compostage des litières est incomplet. Les systèmes de séparation à la source concentrent les bactéries pathogènes zoonotiques cultivables dans les fractions solides des lisiers. Les bactéries pathogènes y survivront potentiellement plus longtemps dû à la présence d'une plus forte concentration en solides. Les bioaérosols des systèmes de litières sont les plus contaminés en microorganismes cultivables (bactéries mésophiles, E. coli, actinomycètes thermotolérantes, moisissures) et sont généralement constitués d'espèces d'Aspergillus. La nature des moisissures aérosolisées est par contre plus diversifiée dans les deux autres systèmes de production (Cladosporium, Pénicillium, Scopulariopsis). Des gènes de résistance à la tetracycline sont également présents dans les bioaérosols des porcheries canadiennes et, pour le gène tetG, en plus fortes concentrations dans les systèmes de litières. Les gènes de résistance à la tetracycline sont de même présents chez des isolats cultivables de bactéries pathogènes zoonotiques. Les bioaérosols des systèmes de séparation à la source sont parmi les moins chargés en microorganismes cultivables, en poussières et en endotoxines totales et semblent alors moins nocifs pour la santé respiratoire des travailleurs. La flore nasopharyngée des producteurs de porcs est contaminée par des bactéries pathogènes zoonotiques et par des bactéries résistantes à la tetracycline. Les bioaérosols pourraient donc être une voie de transmission possible d'infections et de bactéries résistantes aux antibiotiques des porcs aux humains et, par la suite, des travailleurs à la famille.
29

Primary school buildings renovation in cold climates : optimizing window size and opening for thermal comfort, indoor air quality and energy performance

Darvishi Alamdari, Pourya 30 November 2022 (has links)
Dans les bâtiments scolaires existants, la ventilation naturelle constitue souvent l'unique solution pour le contrôle de la qualité de l'air intérieur et le confort thermique. Cependant, de nombreuses études montrent que les salles de classe sont insuffisamment ventilées et entrainent des problèmes de qualité de l'environnement intérieur. Plusieurs études ont été menées sous différents climats, mais peu dans des climats très froids où l'usage de la ventilation naturelle peut entraîner une surconsommation énergétique. Cette recherche vise à étudier l'impact de la ventilation naturelle sur le confort thermique, la qualité de l'air intérieur et l'efficacité énergétique des bâtiments scolaires dans les climats froids. Divers paramètres architecturaux associés aux fenêtres ont été analysés pour une classe type du corpus Schola. Dans cette recherche, l'orientation des fenêtres, leur taille, leur position, la taille et la position de l'ouverture des fenêtres, le programme de ventilation naturelle et les méthodes de ventilation naturelle (unilatérale et transversale) ont été simulés numériquement avec le logiciel Ladybug Tools. Les résultats des simulations produisent données numériques annuelles de température, humidité, température radiante moyenne, concentration de CO₂, pour traiter les conditions thermiques et de Qualité de l'Air Intérieur QAI dans les bâtiments scolaires et de leur impact sur la performance énergétique. L'analyse des résultats utilise les modèles standards 55 ASHRAE, Predicted Mean Vote PMV et extended Adaptive Thermal Comfort ATC pour l'analyse du confort thermique, la Santé Canada et le Centre de collaboration nationale en santé environnementale, la Federation of European Heating, Ventilation and Air Conditioning Associations REHVA pour le contrôle de la COVID-19. Les résultats montrent que l'ouverture répétitive des fenêtres de courte durée pourrait être une solution optimale en termes de confort thermique, de qualité de l'air intérieur et d'efficacité énergétique. Étant donné que la plupart de ces bâtiments scolaires ne sont pas équipés de systèmes CVC et qu'ils ne disposent que de systèmes de chauffage classiques, le manque de qualité de l'air intérieur est un problème inévitable. La solution de la ventilation naturelle pourrait compenser le manque de qualité de l'air intérieur et le coût de la rénovation du système CVC ; cependant, elle devrait être appliquée avec précision pendant les périodes hivernales pour éviter un inconfort thermique et une surconsommation énergétique. / In existing school buildings in Quebec, natural ventilation is often the only solution for thermal comfort and indoor air quality control. However, many studies show insufficiently ventilated classrooms, leading to indoor environment quality problems. Where the arbitrary use of natural ventilation can lead to energy over consumption, several studies have been conducted on the role of natural ventilation on this issue, but few of them are addressed in very cold climates. This research investigates the impact of natural ventilation on thermal comfort, indoor air quality, and energy efficiency of school buildings in cold climates. Various architectural parameters associated with windows were analyzed for a typical classroom in the Schola.ca corpus. Since most of these school buildings are not equipped with HVAC systems and have only infrastructures for conventional heating systems, the lack of indoor air quality is an inevitable problem. In this research, the windows' orientation, position, opening size, and opening position, natural ventilation program, and window-opening modes (single-sided and cross-window openings) were numerically simulated with the Ladybug Tools software. The software outputs consist of annual numerical data (temperature, humidity, mean radiant temperature, CO₂ concentration, energy, and thermal) representing thermal comfort and IAQ performances in school buildings and their impacts on energy consumption efficiency. In analyzing the result, several standards and guidelines were used, including ASHRAE 55 standard models (Predicted Mean Vote PMV and Adaptive Thermal Comfort models ATC for thermal performance), the Health Canada and National Collaboration Centre for Environmental Health guideline, and the Federation of European Heating, Ventilation and Air Conditioning Associations REHVA to evaluate the building thermal and IAQ performances compared to there commended benchmark models. The results show that repetitive short-term opening of the windows could be an optimal solution in terms of thermal comfort, indoor air quality, and heating energy consumption efficiency. Natural ventilation solutions could retrieve the lack of indoor air quality and the cost of HVAC system renovation; however, they should be only applied during cold seasons to avoid thermal discomfort and energy over consumption.
30

Caractérisation des bioaerosols dentaires : un regard sur l'eau des unités dentaires

Dutil, Steve 13 April 2018 (has links)
La tubulure des unités dentaires (UD) démontre la présence d'un biofilm, lequel assure la croissance et le maintien d'une abondante population microbienne planctonique incluant plusieurs pathogènes et pathogènes opportunistes, tels que des légionelles et des mycobactéries non-tuberculeuses (NTM). Les instruments dynamiques connectés aux UD génèrent des bioaérosols. Ainsi, outre la bouche des patients, l'eau de l'UD peut être une source considérable de bioaérosols. De plus, l'analyse par culture sous-estime grandement la biomasse microbienne. Les principaux objectifs de cette thèse sont de : (i) mesurer la génération et la persistance des bioaérosols lors de traitements dentaires; (ii) mesurer l'exposition du personnel et des patients à ces bioaérosols; (iii) adapter et utiliser des méthodes d'analyse des microorganismes non reliées à la culture afin de mieux caractériser l'environnement de travail qu'est le cabinet dentaire et d'augmenter ainsi de manière importante les connaissances reliées aux risques d'infection ou de sensibilisation du personnel et des patients aux bioaérosols. Dans nos conditions expérimentales, il a été établi que les traitements de nettoyage dentaire génèrent des milliers de bioaérosols cultivables provenant de la bouche des patients et possiblement de l'eau des UD. De plus, il a été démontré que le personnel et les patients sont exposés à des concentrations de bioaérosols pouvant atteindre 1,9 E+05 bactéries/m3 . Par ailleurs, le faible diamètre (0,73 um) des aérosols générés, suggère un risque d'exposition. Toutefois, bien que l'eau des UD soit contaminée par des légionelles et des NTM, l'aérosolisation non-significative de ces bactéries propose un faible risque d'exposition pour ces pathogènes. L'utilisation de méthodes d'analyse non reliées à la culture a permis de mieux caractériser l'environnement dentaire : l'hybridation in situ en fluorescence avec un enrichissement préalable par culture a permis de détecter rapidement la présence du pathogène respiratoire Legionella spp. dans l'eau des UD; la microscopie à fluorescence a permis de déterminer la charge bactérienne totale des échantillons environnementaux (bioaérosols et l'eau des UD). Toutefois, la cytométrie en flux ne semble pas une approche adéquate pour la quantification bactérienne. En conclusion, l'utilisation de méthodes d'analyse non reliées à la culture a démontré que le personnel dentaire et les patients sont exposés à des bioaérosols générés lors de traitements dentaires.